47 (Cost/s) (kJ/h)
57 E-104 C2 80.00 T 140.0 HP Steam 250.0 249.0 7.362e+005 * 7.7 OK 110.0 169.0
60 E-106 Cooling Water 20.00 23.44 H2 150.0 T 30.00 T 4.320e+005 14.1 OK 126.6 10.00
61 E-105 Cooling Water 23.44 25.00 H1 98.77 T 80.61 T 1.962e+005 4.4 OK 73.77 57.17
62
63 Aspen Technology Inc. Page 1 of 4
Licensed to: Company Name Not Available Specified by user.
1
Case Name: Devi Ramadani_1807110584_tugas3pptk.hch
2 Company Name Not Available
3 Bedford, MA Unit Set: SI
4 USA
Date/Time: Sat May 08 18:22:49 2021
5
6
7
HI Design Datasheet
8 HIP1
9 Scenario 1
10
11
A_Design1
12
13 Heat Exchangers
14
15
Summary
16
17
ALL HEAT EXCHANGERS
18
19 Heat Exchanger Load Cost Area Shells LMTD HTC F Factor Fouling
28 Heat Exchanger Hot Stream Hot T in Hot T out Cold Stream Cold T in Cold T out dT Min Hot dT Min Cold
36
HEAT EXCHANGERS FOR STREAM: HP Steam
37
38 Heat Exchanger Load Cost Index Area Shells LMTD HTC T in T out Matched With
41
DRIVING FORCE PLOT
42
43
44
Driving Force Plot
250.0
45
46
47
200.0
48
Hot Temperature (C)
49
50
150.0
51
52
53 100.0
54
55
56 50.00
57
58
59 0.0000
0.0000 50.00 100.0 150.0 200.0 250.0
60
61 Cold Temperature (C)
62
63 Aspen Technology Inc. Page 2 of 4
Licensed to: Company Name Not Available Specified by user.
1
Case Name: Devi Ramadani_1807110584_tugas3pptk.hch
2 Company Name Not Available
3 Bedford, MA Unit Set: SI
4 USA
Date/Time: Sat May 08 18:22:49 2021
5
6
7
HI Design Datasheet
8 HIP1
9 Scenario 1
10
11
A_Design1
12
13 Targets
14
15 Heating 2.880e+005 kJ/h * Operating Cost Index 2.106e-004 Cost/s *
16 Cooling 1.800e+005 kJ/h * Capital Cost Index 1.914e+005 Cost *
17 Number of Units 5 * Total Cost Index 1.812e-003 Cost/s *
18 Total Area 243.1 m2 *
19
20 Topology Data
21
22
Sub-Networks
23
24 Number of Sub-Networks 2 *
25 Network Number Streams in Network
26 1 * H2
27 H1
28 2 * C1
29 C2
30
Loops
31
32 Independant Loops: 1 * Dependant Loops: 1 *
33 Loop Number Exchangers in Loop
34 E-102
1 *
35 E-107
36
Paths
37
38 Path Number Hot Utility Heat Exchangers in Path Cold Utility
39 E-104
41 E-105
42
Utilities
43
44 Utilities in Design Utility Included in Searches for Sub-Nets, Loops and Paths
45 HP Steam Not Included
47
48 Notes
49
50
Design Notes
51
52
53
54
Modification Log
55
56
Added splitter-mixer TEE-100-MIX-100 by automatic design module;Cooler E-100 is added by automatic design module;Added splitter-mixer TEE-101-MIX-101 by automatic design module;Heater E-101 is added by automatic design module;Heat exchanger E-102 is added by automatic design modu
57
58
59 Grid Design
60
61 Infeasible HX: 0, HX Not Calculated: 0Unsatisfied Streams: 0
62
63 Aspen Technology Inc. Page 3 of 4
Licensed to: Company Name Not Available Specified by user.
1
Case Name: Devi Ramadani_1807110584_tugas3pptk.hch
2 Company Name Not Available
3 Bedford, MA Unit Set: SI
4 USA
Date/Time: Sat May 08 18:22:49 2021
5
6
7
HI Design Datasheet
8 HIP1
9 Scenario 1
10
11
A_Design1
12
13 Grid Design
14
15
Cross Pinch
16
17 Pinch 90.00 C / 80.00 C
29
30
31
32
33
34
35
Stream Load Status
36
37 Streams Type Unsatisfied % of Total Total
38
39
Network Heating
40
41 Utility Type Cost Index Load % of Target
42 (Cost/s) (kJ/h)
48 (Cost/s) (kJ/h)