You are on page 1of 2

Powerware® 9315-80

Features Model 50 50kVA/40kW


Model 65 65kVA/52kW
 DC Expert™ battery management Model 80 80kVA/64kW
system featuring:
- +/- 3% battery run time
- Battery health indication
 Powerware Hot Sync™ Redundant
Environmental Specifications
capability
Ambient temp: 0°C to +40°C
 Large display panel provides
Storage: –20°C to +70°C
metering, statistics, alarm history and Relative humidity: 5-95% non-condensing
an active mimic screen Altitude: 1500 meters (5000ft.) at 40°C
 Prioritized cooling of components ambient emperature without
 Flexible communication capability load derating
Local Communications Audible noise: Less than 65 dBA at 1 meter;

- Monitor panel in accordance with ISO 7779


Electrostatic Withstands 25kV without
- Illuminated indicators
discharge: damage or disturbance to
- Control panel
the load; exceeds
Remote communications requirements of IEC 801-2
- Relay interface contacts EMC: Meets FCC Class A and EN
- Building alarm contacts 50091-2 (CISPR 22, Class A)
(programmable)
- Summary alarm contacts
Input Specifications Battery Specifications
- RS232 port (standard)
Voltage range: (See chart on other side) Matching cabinets Line-up or remote
- EPO kit Frequency range: (60 Hz) 57-63 Hz;
Battery type Sealed, valve regulated lead acid
- Remote monitor panel (50 Hz) 47-53 Hz
Recharge time 10-12 times the discharge time
 Communications options Surge protection: Meets ANSI C62.41, Category A &
to 95%
B, EN 50091-2 and EN 50082-2
Embedded communications slot to Other battery Wet cell and nickel-cadmium
Power factor: 0.95 typical at full load with input
accept the following cards: options batteries; open racks available
filter. Input current distortion
- ConnectUPS-X SNMP/Web card less than 7% with input filter For battery runtimes and
- Multi-server card (S-RS232 serial configurations, refer to Bulletin
Output Specifications BAT01FXA.
port output)
Voltage THD: Less than 5% (100% non-linear Safety
- Single port serial card
load with 3:1 crest factor); less
Expansion chassis available for increased UL1778 Listed cUL CAN/CSA C22.2
than 3% (100% linear load)
communications capabilities NO.107.1-M91 Listed EN 50091-1
Voltage regulation: Better than ±1%
All cabinets provide seismic
 Intelligent input filter option Transient response: Less than 5% for 100% load step;
full recovery within 1 cycle mounting features
Frequency: (free run) ±0.005 Hz Selectable DC ground fault
Frequency sync range: ±0.5 Hz detection capability
Frequency slew rate: 1 Hz/second maximum
Note: Dual feed input not available for 208V or 220V input.
Voltage adjustment
Specifications subject to change without notice.
range (operator): ±5%

Powerware Recommends
Software Connectivity Service System Solutions
> PowerVision® > ConnectUPS-X > ProActive > PF2 Flywheel
> LanSafeTM SNMP/WEB Service Plan > PDM
card > Preventive > RPP
> FORESEER®
> Multi-server card Maintenance > Powerware Hot Sync
> CELLWATCH® > External Maintenance
Bypass
Please contact your sales representative for a solution tailored to your specific needs.