You are on page 1of 5

5017272800

ESAA150ACTA0101
DC Power System

ESAA150-CTA Series is the power system playing the leader Key Features
role in wire and wireless network application.  Perfect Integration with
Delta Outdoor Enclosure
To maintain all aspects of the power performance at high  Compact Design 2U System
level, Delta ESAA150-CTA Series is featured with the high  Leading Efficiency 96.4%
cost-performance ratio and gorgeous efficiency all rolled into
one, that is, your one of a kind energy core. Applications
 3G / 4G / 5G
Relying on the advanced controller, flexible PDUs and
 Fixed Line
outstanding rectifiers providing 150A of the power for 48V
 Datacom
system can reach each full potential in a compact 2U shelf.

1/5
ESAA150ACTA0101
INPUT GOAEAS-00-ZL

Voltage (nominal) 1Φ3W; 220VAC


Voltage (range) VL-N: 220/230/240 (±20%)
Frequency 45 - 65Hz
Connections Terminal(L/N/FG) with AC Breaker 70A-2P

OUTPUT
Voltage (nominal) -48VDC
Voltage (default) -54VDC
Voltage (adjustable range) -42 to -58VDC
Maximum Power @ nominal Input 8.7kW
Load: 50A x6
Power Distributions
Battery: 100A x2
LVDS LVBD: 200A

CONTROL AND MONITORING


Operating Voltage 35 – 59.5VDC
Input Power Typical 5W, Maximum 10W
Security Access Password Protected Levels
User Interface LCD (96x64 dots), LED indication, 4-ways tactile switch, PC (via Mini-B USB)
Remote Access Ethernet (optional)
Alarm Output Dry Contact x6
Event Logs > 500
Basic Alarms Mains Failure; Rectifier Module Failure; Voltage Abnormal; Breaker Trip; Temperature Abnormal; LVD Trip
Alarm Level Major / Minor
Rectifier Management Soft Start; Active Efficiency Management; Sequence Control; Remote On/Off
Temperature Compensation; Charge Current Limit; Capacity Setting; Monitoring: Voltage/Current/Temperature;
Battery Management
Boost Charge; Float/Equalized Charge; Battery Test (auto/manual)

MECHANICAL
Dimensions (W x H x D) 482 (19”) x 89 (2U) x 320 (with terminal) mm (18.97 x 3.50 x 12.59in)
Weight approx. 8.5kg (18.73lb) (without rectifier)

ENVIRONMENTAL
Operating Temperature -20 to +65 ᵒC (-4 to +149 ᵒF )
Storage Temperature -40 to +70 ᵒC (-40 to +158 ᵒF )
Altitude 0 to +4000m
Related Humidity 0 – 95 % RH non-condensing
Acoustic Noise ≤ 55dBA @ 1M

STANDARDS
Safety CE Compliance
EMC CE, TUV/UL (rectifier)
Environment RoHS

ORDERING INFORMATIONTION ESAA150ACTA0101


Delta P/N Description Q’ty
ESAA150-CTA01 Front Access 8.7kW DC Power System 1
ESR-48/56C F-A 2900W Single Phase Rectifier 1

* All specifications are subject to change without prior notice.

2/5
Delta Controller
Delta Controller is an intelligent controller for Telecom
Power Solution. As a brain of all aspects of power chain with
elegant battery management suitable for various types of
batteries, ensuring with prevention before problems to
enable cost reduction could not be even easier.

With comprehensive functionality, besides locally accessing


the configuration and supervision unit, remote monitoring
and alarming via web browser is also acceptable. With
the powerful data-gathering function played as an IOT Delta Controller
platform, improving site efficiency and ensuring the power
always on-air is our promise, our insistence.

INPUT GOACAS-01-ZL

Voltage (default) -54VDC


Voltage (adjustable range) -35 to - 60VDC
Current 0.25 ADC (Max.)

MECHANICAL
Dimensions (W x H x D) 43 x 40.5 x 182mm (1.7 x 1.6 x 7.1in)
Weight 0.2kg (0.4lb)

STANDARDS
EMC EN 55022, class B ; ETSI EN 300386 compliant
Cooling Natural air flow
Operating Temperature -40 to +65 °C (+40 to +149 °F)
Relative Humidity 95%, non-condensing

FEATURES
Number of Rectifiers Up to 16
Number of Relay Output Up to 6
Remote Monitoring - Dry contacts / WEB server(option) / SNMP

FUNCTIONS
- User configurable alarms and settings
System - LVD and PLD functions (1 as standard, additional 2 as option)
Configurable alarm relays
- Temperature compensated float charge, boost and equalize charge
Battery
Charging current limitation
- Efficiency mode with advanced rectifier cycling
Rectifier
- Individual rectifier information and control

USER INTERFACE
Local User Interface 2 LEDs; LCD display; control stick, local access (USB)
WEB Web UI (option)
Languages English, Traditional Chinese and Japanese

ORDERING INFORMATION
Delta Controller CU-19C A

* All specifications are subject to change without prior notice.

3/5
DPR 2900B EnergE
Delta’s technology leading telecom rectifier DPR 2900B
EnergE provides the industrial leading efficiency of 96.4%.
The single phase, hot pluggable fan cooled rectifier
provides the 36.5W/in³ outstanding power density.
Integrated with the high efficiency rectifier DPR 2900B
EnergE, Delta power solution provides an energy saving
solution for network base stations, wireless applications,
fixed line applications and data communications. DPR 2900B EnergE

Efficiency Curve Output Characteristic

Efficiency % Vout (V)


Ambient Temperature: -40~45°C ; Vin 176VAC~300VAC
98
58.0
96
54.0
94 51.7

92

90
20.0
88

86 Load % 0.0 Iout (A)


0 10 20 30 40 50 60 70 80 90 100 40.0 53.7 56.0

Input Characteristic Temperature Characteristic


Po (W)
Ambient Temperature: -40~45°C Po (W) Vin: 176VAC ~ 300VAC

2900
2900

2700

2400 OTP restart


1350
2000 OTP shutdown

1800

Vin (V) Amb (ᵒC)


80 88 176 280 288 300 45 55 65 75 80

4/5
DPR 2900B EnergE
INPUT GOAEAS-07-ZL

Voltage (nominal) 230VAC


Voltage (range) 90 - 300VAC; De-rating ≤ 176VAC
Frequency 45 - 66Hz
Power Factor > 0.99
Total Harmonic Distortion < 5%
Lightening Protection EN 61000-4-5

OUTPUT
Voltage (default) -54.0VDC
Voltage (adjustable range) -42 to -58VDC
Maximum Output Current 56.25A
Maximum Power @ nominal Input 2900W
Power Density 36.5W/in3
Peak Efficiency 96.4%
Load Regulation ≤ ± 250mV
Ripple ≤ 150mV
Current Sharing ≤ ± 5%
Lightening Protection EN 61000-4-5

USER INTERFACE
Alarm and Signaling CANbus to System Controller
OK Green Normal Operation
Indications NL Yellow Output current < 5%
COM Green Communication Status

MECHANICAL
Dimensions (W x H x D) 125.5 x 41.0 x 272.9mm (4.94 x 1.61 x 10.74in)
Weight 1.8kg (3.96lb)

ENVIRONMENTAL
Operating Temperature -40 to +75 ᵒC (-40 to +167 ᵒF ) ; De-rating above 45ᵒC (+113 ᵒF)
Storage Temperature -40 to +80 ᵒC (-40 to +176 ᵒF )
Altitude 0 to +4000m
Related Humidity 0 – 95 % RH non-condensing
Acoustic Noise ≤ 55dBA

STANDARDS
Passes TUV, CE, UL cUL, S-mark certifications;
Safety Catch the CB certificate;
Complies with IEC/EN/UL60950-1
EN 55022 AC Class B & DC output Class A
EMC
EN 300 386
Environment RoHS
MTBF 300k hours @ 25 ᵒC (+77 ᵒF)

ORDERING INFORMATIONTION
ESR-48/56C F-A 2900W Single Phase Rectifier

* All specifications are subject to change without prior notice.

Delta Electronics Inc.


3 Tungyuan Road, Chungli Industrial Zone,
Taoyuan City 32063, Taiwan.
T +886 3 452 6107 / F +886 3 452 7314 5/5
www.deltaww.com