You are on page 1of 4

DUMC

48/50H System
FEATURES
19’’,6U,sub-rack, easy to be
embedded into all Standard
kinds of telecom
equipment.Front access and
front connection

System total capacity up to


18kw for 6U sub-rack system
with 50A rectifier

PFC technique features the


system high efficiency,
energy-saving and up to 0.99
power factor.
INTRODUCTION
Intelligent fan-cooling
DUMC-48/50H System is a compact and intelligent power system containing
technique brings good
up to 6 DZY-48/50H rectifiers, DKD51 controller module, AC connection and
cooling performance , low
DC connection . in addition , easy installation to compact size add to the
failure rate and high
success of the system.
reliability.

Fast on-line expansion of


rectifier modules enabled
by hot-swap.
PPLICATIONS
N+1 rectifier module Fiber optic network
redundancy. Access network
Transmission equipment
Automatic management of Mobile communication
battery charging and Satellite communication ground
temperature
compensation function.

Switch Mode Power System Distribution Cabinet Inverter


Remote Monitoring System DC/DC Converter UPS/EPS
Renewable Energy Solution Hybrid Power System HVDC UPS

Beijing Dynamic Power Co.,Ltd.


www.dpc.com.cn
NO.8 Xinghuo Road, Science City, Fengtai District, Beijing, P. R. China
SPECIFICATIONS
AC Input Monitoring and Control
AC supply 155V-520Vac (Nominal: 380Vac) Monitoring unit DKD51
Three phase five wires input

Frequency 45-65Hz Remote RS485 or RS232


Power Factor ≥0.99 operation SNMP/Ethernet
Voltage wave
<5%
distortion
LCD – system status
Current Distortion 5% ≤50~100% load Visual Green LED – System ON
Soft start indications Yellow LED – Minor alarm(s)
Surge protection (SPD: class C) Red LED – Major alarm(s)
Protection
Internal fuses (L & N)
Over voltage protection Alarm relays 8 relays
AC input 1*63A/3P MCB
Digital inputs 6 options (for monitoring of external
DC Output
equipment and battery)
Voltage -48VDC (-40--58VDC adjustable)
Current 300A ultimate capacity
AC failure alarm
Voltage Rectifier failure alarm
≤±0.6%
regulation Load fuse alarm
Current Battery fuse alarm
±5% Alarms
Sharing LVD operated
Low output voltage alarms
Efficiency Typical: 96%, (DZY-48/50H I) High output voltage alarms
Symmetry alarm
Ripple and
200mV p-p
Noise
Other Specifications
Psophometric
2mVrms
noise Operating -45 to +75°C (-49 to +167°F)
Over/under voltage shutdown temp Full power @-40 to +55°C
Protection Short circuit proof
High temperature protection Storage temp -45 to +75°C (-49 to +167°F)
DC Distribution Options
No.of Load 4*63A/1P; 2*16A/1P Operating: 90% non-condensing
Humidity
MCBs 2*32A/1P; 2*20A/1P;4*10A/1P(6U) Storage: 95% non-condensing
No.of Battery
4*125A/1p (6U)
MCBs Dimensions 482W*265H*364.7 D(mm) 6U
LLVD1: 2*63A/1P; 2*16A/1P
LVD
LLVD2: 2*63A/1P Weight 18kg excl. rectifiers 6U
LLVD3: 4*10A/1P; 2*20A/1P; 2*32A/1P
Rectifier
Type DZY-48/50H I

Beijing Dynamic Power Co.,Ltd.


www.dpc.com.cn
NO.8 Xinghuo Road, Science City, Fengtai District, Beijing, P. R. China
FEATURES
DZY
power density
Typical 96%
48/50H I
Digitalized control
Digitalized Primary and
secondary controls could
realize excellent monitoring
and regulation.

High reliability design

with latest thermal solution


and experienced electric
synthetize ensure suitable
working environment and high
reliability.
INTRODUCTION
Disconnect mains when
hazardous input
DZY-48/50H I will disconnect
mains to protect itself when it power system is a big family of -48V DC power system which could cover
can not sustain the input global demand for telecom applications with wide operating temperature and
voltage. wide input voltage range.

Excellent EMC performance


PPLICATIONS
Lower interference and
Wireless communication
excellent susceptibility give
Broadband and network access
module better reliability
Satellite communication ground station
3G /4G base station
Telecom roadside cabinets

Switch Mode Power System Distribution Cabinet Inverter


Remote Monitoring System DC/DC Converter UPS/EPS
Renewable Energy Solution Hybrid Power System HVDC UPS

Beijing Dynamic Power Co.,Ltd.


www.dpc.com.cn
NO.8 Xinghuo Road, Science City, Fengtai District, Beijing, P. R. China
—12—
SPECIFICATIONS
AC Input Applicable Standards
Nominal: 220/240Vac 1ph
AC supply Tolerances: 85-300Vac 1ph Electrical Safety IEC60950 UL60950
Frequency 45~65Hz
IEC61000-4-6(conducted immunity)
≤13Arms at nominal input
Input current IEC61000-4-3(radiated immunity)
≤16Arms at 185Vac input
IEC61000-4-2(electrostatic discharge)
Power Factor >0.99
EMC IEC61000-4-4(fast transients)
Input protection Varistors for transient protection
IEC61000-4-5(surge immunity)
THD <5% at 50-100% load
IEC61000-4-11
DC Output IEC61000-3-3
Nominal output: 48VDC
Output voltage Standby test range: 40 ~58VDC
Harmonics EN 61000-3-2
2900W at nominal input
Output power Constant Power: >53.6VDC ETSI EN 300 019-2(-1,-2,-3)
Derating below:1140W at 85Vac
ETSI EN 300 132-2
Output current 53A at nominal input Environment
Telcordia NEBS GR63 CORE Zone 4
Typical:96%
RoHS compiant
≤±5% unbalance of average current
Current sharing of all paralleled modules
Static Voltage
Regulation ±0.5% from 5% to 100% load DIAGRAMS
Dynamic voltage±5% for 25-50% or 50-75%load
regulation variation, regulation time<200us Output Power vs. Input Voltage
>10ms, (50A when output voltage 3500
Holdup time from 53.6V to 43.2V. 3000
Po(W)

2500
Ripple and <200mV p-p, 20MHz bandwidth 2000
1500
Noise <2.0mVrms psophometric 1000
500
Overvoltage shutdown 0
Output Short circuit proof 90 120 154 165 176 180 220 297
Vi(Vac)
protection High temperature protection
Output fuse
Output Voltage vs. Output Current
Mains over or under voltage 60
Mains over voltage disconnection 50
Alarm
Io(A)

High ambient temperature 40


Short on output from outside 30
20
Cooling 10
0
Fan speed Temperature and output current regulated 0 40 43.2 53.6 57.6 58 58.5
Vo(Vdc)
MTBF >100,000 hours
<55dBA at nominal input and Full load
Acoustic noise (Tambient<30°C)
-45 to +75°C (-49 to +167°F)
Operating temp -40 to +55°C (full load) 97
96
η(%)

Storage temp -40 to +85°C (-40 to +185°F) 95


94
Operating:≤95% non-condensing 93
Humidity Storage:≤99% non-condensing
92
91
Dimensions 73W×295D×135.5H (mm) 90
1 2 3 4 5 6 7 8 9 10
Weight 2.5 kg Io(A)

Beijing Dynamic Power Co.,Ltd.


www.dpc.com.cn
NO.8 Xinghuo Road, Science City, Fengtai District, Beijing, P. R. China
—13—