Professional Documents
Culture Documents
Diameter expanded*
AZUR® HydroCoil® Diameter non-expanded
(maximum)
Detachable 0.018” 0.018” 0.032”
A Validated Technology
The hydrogel polymer technology featured
Watch this little coil in the AZUR® Peripheral HydroCoil®
Embolization System has been clinically used
for more than 5 years in cerebral aneurysms,
GI bleedings, visceral aneurysms, pulmonary
become AVMs and trauma. It has been analysed
the biggest thing in more than 200 laboratory studies, 20
peer-reviewed articles, 100 oral and poster
presentations that demonstrate:
• Lower vascular recurrence rates versus
in peripheral
platinum and PGLA coils3,4
embolization
• Enhanced reconstruction of the artery wall
versus platinum coils4,5,6
• Increased filling with fewer coils than
previously required1,2
References:
1. Sluzewski M, van Rooij WJ, Slob MJ, Bescós JO, Slump CH, Wijnalda D. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology. 2004;231(3):653-658.
2. Cloft HJ, Kallmes DF. Aneurysm packing with HydroCoil® Embolic System versus platinum coils: initial clinical experience. AJNR Am J Neuroradiol. 2004;25(1):60-62.
3. DURABLE Multi-center HES Registry (Albany Medical Center, Beaumont Regional Medical Center, Loyola University Medical Center) of 260 aneurysms with 186 follow-ups treated with HydroCoil®. Presented at ABC/WIN. 2006.
4. Plenk H, Killer M, Richling B. Pathophysiologic considerations on HydroCoil®- and platinum coil-occluded retrieved human cerebral aneurysms. Presented at ASITN MicroVention Symposium. 2005.
5. Fujiwara NH, Kallmes DF. Healing response in elastase-induced rabbit aneurysms after embolization with a new platinum coil system. AJNR Am J Neuroradiol. 2002;23(7):1137-1144.
6. Kallmes DF, Fujiwara NH. New expandable hydrogel-platinum coil hybrid device for aneurysm embolization. AJNR Am J Neuradiol. 2002;23(9):1580-1588.
7. Bavinzski G. Talazoglu V. Killer M. et al. Gross and microscopic histopatological findings in aneurysms of the human brain treated with Guglielmi detachable coils. J Neurosurg. 1999;91(2):284293.
8. HEAL Registry. MicroVention, Inc. (197 aneurysms: 128 fallow-up cases: mean follow-up of 14 months).
9. Virmani R. Healing and inflammation in experimental and clinical aneurysms. Presented at WFITN. 2005.
10. Ding YH, Dai D, Lewis DA, Cloft HJ, Kallmes DF. Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil®. AJNR Am J Neuroradiol. 2005;26(7):1757-1763.
11. Bui Jt, West DL, Pai R, Owens CA. Use of a hydrogel-coated self-expandable coil to salvage a failed transcatheter embolization of a mesentric hemorrhage.
12. Aina R, Olivia VL, Therasse E, et al. Arterial embolotherapy for upper gastrointestonal hemorrhage: outcome assessment.J Vasc Interv Radiol. 2001;12(2):195-200.
13. Fanning NF, Berentai Z, Brennan PR, Thornton J. HydroCoil® as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms. Neuroradiology 2007;49(2):139-148. Epub 2006 Nov 22.
Peripheral HydroCoil® Embolization System
® ®
AZUR Peripheral HydroCoil Embolization System
Pushable 18 System/Pack of 3 coils Detachable 18 System/Pack of 1 coil
Product Code Loop Diameter Length* Product Code Loop Diameter Length*
45-280202 2 mm 2 cm 45-480202 2 mm 2 cm
45-280302 3 mm 2 cm 45-480204 2 mm 4 cm
45-280304 3 mm 4 cm 45-480302 3 mm 2 cm
45-280402 4 mm 2 cm 45-480305 3 mm 5 cm
45-280404 4 mm 4 cm 45-480310 3 mm 10 cm
45-280406 4 mm 6 cm 45-480405 4 mm 5 cm
45-280504 5 mm 4 cm 45-480410 4 mm 10 cm
45-280506 5 mm 6 cm 45-480415 4 mm 15 cm
45-280510 5 mm 10 cm 45-480420 4 mm 20 cm
45-280606 6 mm 6 cm 45-480610 6 mm 10 cm
45-280610 6 mm 10 cm 45-480615 6 mm 15 cm
45-280614 6 mm 14 cm 45-480620 6 mm 20 cm
45-280810 8 mm 10 cm 45-480810 8 mm 10 cm
45-280814 8 mm 14 cm 45-480815 8 mm 15 cm
45-281014 10 mm 14 cm 45-480820 8 mm 20 cm
45-481010 10 mm 10 cm
Pushable 35 System/Pack of 3 coils 45-481015 10 mm 15 cm
45-481020 10 mm 20 cm
Product Code Loop Diameter Length*
45-481215 12 mm 15 cm
45-250404 4 mm 4 cm 45-481220 12 mm 20 cm
45-250406 4 mm 6 cm 45-481515 15 mm 15 cm
45-250506 5 mm 6 cm 45-481520 15 mm 20 cm
45-250510 5 mm 10 cm 45-481530 15 mm 30 cm
45-250610 6 mm 10 cm 45-482020 20 mm 20 cm
45-250810 8 mm 10 cm 45-482030 20 mm 30 cm
45-250814 8 mm 14 cm
45-251014 10 mm 14 cm
45-251514 15 mm 14 cm
* Length is calculated from the tip of the coil to the point of connexion with the pusher wire when the coil is straight Compatibility
Detachment Controller for Use with Detachable AZUR® HydroCoil® Catheter Guide wire
System/Pack of 5 units Pushable 0.018” PROGREAT 2.4 Fr 0.016” or 0.018”
Pushable 0.035” Glidecath 4 or 5 Fr 0.035” or 0.038”
Product Code Product Description Detachable 0.018” PROGREAT 2.8 Fr 0.016” or 0.018”
45-4001 AZUR Detachment Controller Detachable 0.018” PROGREAT 2.7 Fr included
Tel.: +33 139 30 95 75 Fax: +39 0650 30 407 28806 Alcalá de Henares
Fax: +33 139 30 95 70 (Madrid), Spain
Addresses subject to change,
Terumo UK Ltd Tel.: +34 9021 01 298
please consult our Website.
Tamesis, The Causeway Fax: +34 9021 01 358
Egham, Surrey
TW20 9AW, United Kingdom Terumo Denmark ® Registered Trademark
Tel.: +44 1784 476 200 Filial of Terumo Sweden AB Published by Terumo Europe N.V.
Fax: +44 1784 476 201 Tel.: +45 7020 93 80
Fax: +45 7020 94 80
www.terumo-europe.com