Professional Documents
Culture Documents
INSTRUCTION
parameters Summary
This document describes changes of the
WECS-9520 parameter values according
Information to all Owners and Operators of to the Technical Bulletin RT-104, Issue 1,
Wärtsilä RT-flex96C-B engines with dated 23.02.2011 and provides the
WECS-9520 software version 32-082 instruction for the parameter adjustment
by the “flexAdjust tool”.
Current situation
Operation experience with WECS-9520
system has shown that some parameter
values are not ideal for the following
cases:
• Fuel quantity piston start speed
• Auto restart function
• Minimum fuel injection time
Solution
Adjust values of respective parameters in
the WECS-9520 system on engines in
service by means of the “flexAdjust tool” in
order to improve the performance of the
engine and the WECS-9520 system.
A respective parameter set is available for
each installation.
Next steps
Execute “flexAdjust” according to this
instruction and send a feedback report to
Wärtsilä Services, Operation Support
2-stroke engines:
technicalsupport.chts@wartsila.com
Contents
Page
Introduction 2
Adjustment of parameters with flexAdjust tool 3
Work procedure 3
Adjustment of “First CRC” values 8
Work procedure 8
Introduction
This instruction describes how use the flexAdjust tool for changing the values of
the following parameters:
Remark:
For more information please read the related topics in the Technical Bulletin
RT-104, Issue 1, dated 23.02.2011.
WORK INSTRUCTION I-10
Issue 1, Page 3 / 10
Note:
Before executing the flexAdjust tool the following conditions must be fulfilled:
• Engine stopped
• WECS-9520 system is powered on
• flexView program is closed, i.e. not running
Work procedure
Note:
The content of this zip file can only be applied to any RT-flex96C-B engine with
WECS-9520 control system.
1 3 2
1. The name of Plant, 2. flexAdjust program file, 3. flexAdjust database – file with
new parameter values
Fig. 1
Remark:
The name of the plant consists of the shipyard abbreviation and the hull number
of the vessel, e.g. HHI1700, OSS214, etc.
WORK INSTRUCTION I-10
Issue 1, Page 4 / 10
1. Confirmation button
Fig. 2
4. The flexAdjust program starts and the window with a list of parameters which
have to be adjusted will be displayed, see Figure 3
flexAdjust window
Fig. 3
WORK INSTRUCTION I-10
Issue 1, Page 5 / 10
5. Press the button “Read Values” (5) at the bottom of the flexAdjust window,
see Figure 4
Note:
If the new value of the adjusting parameter equals to the current value in the
WECS-9520, it will not be shown in the list of the flexAdjust window.
1 2 3
4 5 6 7
Question window
Note:
In case of successful parameter writing into the WECS-9520 system, the list as
displayed in the flexAdjust window will disappear, see Figure 3.
10. Uncheck the box (4) “Show Only Differences”, see Figure 4
11. Press the button “Read Values” (5) at the bottom of the flexAdjust window,
see Figure 4
13. Press the button “Exit” (7). The flexAdjust window as shown in Figure 4 will
be closed
Note:
On the flexView SW-Info card will be an indication by a red or blue checkmark (1)
that global and commissioning parameters have been changed. That is a normal
situation after a parameter change with the flexAdjust tool, see Figure 6. To
correct these CRC values, they have to be adjusted according to the instruction
in the next chapter.
1. CRC checkmark
Fig. 6
15. Please send a feedback report and the screen shot pictures as made in
point 7. and 12. to:
technicalsupport.chts@wartsila.com
WORK INSTRUCTION I-10
Issue 1, Page 8 / 10
Work procedure
flexView folder
1 2
CRC-Adj
1
1. CRC-Adj card button
Fig. 8
WORK INSTRUCTION I-10
Issue 1, Page 9 / 10
CRC-Adj card
1 2 3
Remark:
First CRC values (1) of the parameters are calculated during software initial
configuration and are stored in the “Datacontainer”. Current CRC values (2) are
calculated cyclically by the WECS-9520 application program. Current CRC
values are constantly being checked with the First CRC values. In case of a
difference between the two CRC values, a red or blue checkmark (3) is
displayed, see Figure 9.
5. Set the correct values of CRC by means of “Shift” and “Arrow up” or “Arrow
down”, see Figure 10
Note:
For the parameter access a login menu pops up when you try to change a value
with “Shift” and “Arrow up” or “Arrow down” keys. The password is “flexView”.
See chapter 7.1 of the fV-Operator Manual.
WORK INSTRUCTION I-10
Issue 1, Page 10 / 10
Fig. 10
Note:
After the successful CRC adjustment, the checkmarks as displayed in column (3)
of Figure 9 will be changed to “ok”. It might take a couple of minutes until “ok” will
be displayed.
For questions about the content of this Work Instruction or if you need Wärtsilä
assistance, services, spare parts and/or tools, please contact your nearest
Wärtsilä representative or send your enquiry to:
technicalsupport.chts@wartsila.com
or phone 24hrs Support: +41 52 262 80 10.