You are on page 1of 1

Page 1 of 1

Issued To : M/s.Rocks Forever


Address : Plot No.B-436,Bhamashah Industrial Area, Report No : STL/210719001538
RIICO Kaladwas, Udaipur-313001, Date of Receipt : 19/07/2021
Rajasthan, India
Contact Person :Mr.Rajesh Rayudu Date of Start : 26/07/2021
Phone : 9390001709 Date of Completion : 04/08/2021
E-Mail : rayudu.raj@gmail.com Report Date : 05/08/2021

Ref. No : CRF No:1201,Dt:19/07/2021


Sample Details : Polished Granite
Sample Description : Polished Black Granite
Sample Qty : 01 No
Test Required : Water Absorption, Density, Compressive Strength, Modulus of rupture, Flexural Strength,
Abrasion Resistance.

Test Result

I.Mechanical Testing
1.Soil and Rock
S.No Test Parameters Units Results Test method

1 Water Absorption % 0.23 IS 1124-1974

2 Density Kg/cu.m 3082 IS 13030-1991

3 Compressive Strength Kg/cm2 1434.51 IS 1121 (Part1)-1974

4 Modulus of Rupture N/mm2 24.61 ASTM C99:2015

5 Flexural Strength N/mm2 21.41 EN 12372-2006

6 Abrasion Resistance Ha 27.01 ASTM C241:1997


**End of Report**

For SANRAY LABORATORIES PVT LTD


Authorized Signatory

REMARKS The sample is submitted by the customer. *IBR Approved Laboratory