You are on page 1of 41

SISTEMA ELÉCTRICO – JUMBO S1D

ING. RAFAEL RUIZ RAMOS


2

Component overview

Function of the main components

How to read and navigate on the schematics


▪3
3

ELECTRIC SYSTEM
Electric cabinets and electric boxes

This is in general how the


electrical boxes are placed
on a M/L/E rigs.
▪4
4

6. ELECTRIC SYSTEM
Electrical Cabinets A10/A40/A50 A40/A10

A50
5

Component overview

Function of the main components

How to read and navigate on the schematics


ELECTRIC SYSTEM

▪ Please bring out the electric diagrams for 24V

6
Lets start with 24V diagrams 5112 0039 03

7
B=
Pressure
switch

8
B 364 Brake light pressure switch B 358 Cable reel limit switch

B=
Pressure
switch

9 B 361 Engine coolant level switch B 355 + B356 Transmission oil pressure indicator +
interlock switch
E = Lights

10
E 102 Tramming lights

E = Lights

E 111 Cabin light

11 E 105 Stair light left


F = Fuse

K = Relays

F = Fuse
M = Motors

12
F = Fuse

K = Relays

F = Fuse
M = Motors

13
G = Batteries
N = Control units

14
G = Batteries
N = Control units

15
H = Warning Lamps

16
H = Warning Lamps

17
K = Relays

18
K = Relays

19
M = Motors

M = Motors

20
M = Motors

Front + rear windshield washer pumps


M104 + M109

Diesel engine starter motor M 101

M = Motors

21
N = Control units

22
N = Control units
P = Gauges

23
N = Control units
P = Gauges

24
N = Control units

R = Resistors

25
S = Switches

26
S = Switches

27
T = Transformers

28
V = Diodes

29
V = Diodes

30
X = Connections

31
Y = Valves

32
Y = Valves

33
F = Fuse T = Transformers
G = Batteries M = Motors

N = Control units V = Diodes

B= P = Gauges
Pressure R = Resistor X = Connection point
switch
H = Warning Lamps

Y = Valves

E = Lights

S = Switches
K = Relays

F = Fuse
M = Motors

34
35

6. ELECTRIC SYSTEM
How to find the electrical schematics in the documentation

▪ This means that there are two sets of circuit diagrams, 24V and 480V in
this case
36

Component overview

Function of the main components

How to read and navigate on the schematics


37

Reference
Page 7 / Coordinate 6C
Page 7 / Coordinate 6A Name of the function

Type of contactor
NC=Normally closed
NO=Normally open

Reference
Page 7 / Coordinate 6A
Page 7 / Coordinate 6C

Relay Coil
38

Reference Reference
Page 7 / Coordinate 6A Page 3 / Coordinate 8E
39

Connection between 11 and 12 = Normally Closed

Connection between 11 and 14 = Normally Open


40

Terminals in A71 = box/panel X5 = contact


another 50 = terminal B13 = pin
diagram/box
41