You are on page 1of 17
Trip Unit for MCCB WiNbreak 2 MCCB Electronic Trip Units (Multifunction) - Overview ‘Types: ETM33, ETM43 Range of overload protection setting current (Ir): 64~630A (ETM33), 250~800A (ET ‘Two frame size of circuit breakers: 630AF, BO0AF Trip units ETM33 and ETM43 can be mounted on circuit breakers of N, H and L type €8400/CS630/CS800 Only thr (3) pole circuit breakers are available 160, 250 400 . ° 630 ° 800 ° Circuit breakers CS400 N7H/L_|_CS630 N/H/L_|_CS800 N/H/L 64 80 Applicable Circuit breakers | C5400 N/H/L_| C5630 N/H/L_| C5800 N/H/L (Woverioad /prarenlen (ong tite) iia ane mene S| Tripping time (s) ot 6 x Ir_| Adjustable 0.4 ~ 1.0 x In, 30 setings Rated current, Ir (A) Adjustable 2, 8, 12 5 settings, tolerance +20% Adjustable 1.5, 2, 3, 4, 5, 6, 7, 8, 10. I, Tapping threshold (A), ed | See ee iste ‘Adjustable 50, 100, 200, 300 4 settings, tolerance 115% ey “Ft constant = function” on, off Tripping threshold (A), li_| Adjustable 1.5, 2, 8, 10, 11 xn, 9setlings LED indication Ir lsd, fi, Se ‘Ammeter (A) Moximum load phase current and R, S, T, N phase current ‘Adjustable tripping threshold (A), 0.2—1 x In, 9 selings ig) | Adiustable time delay (ms), 100, 200, 300, 400 Earth fault protection (E) | 4 setting, tolerance +20% Constant "I2t = function” on, off Setting, B.S, T,N phase curcent, tipping reason ZSI input and output signal — Communication Z3I (Z) Electronic Trip Units (Multifunction) - Overview Configuration on™, O08, alarm Or Ou QD Adjustable rated curent sting te ® indication tz0 ® Aajustbie long time soting © Rip ooson) buton @® Advstoble short time current sting Qed) GD Dispy LCD [Ames @ Akwstoble time dele sting Id) @) Auitiy power ® Adiusoble instantaneous current setting (i @ es connector | ®© Avstable orth foukcument sting ta @ Aborm te 90% FON, 105% ror more: ON-OFF | ® Aéistole cot fut delay sting Ht Alarm indication | ‘The LED lights and remains It when the loud exceeds 90% ofr ‘The LED blinks for an overload (> 105% i, warning that the circuit breaker my trip. Fault indications LEDs indicate the type of ful thot coused tripping Ir: overload led short-circuit (chor time, instantaneous) Ig: earth foul IF push the TR button to indicate the Wippingveesion, the indleation LED of tipping is ON, ‘The information is however stored in memory and the LED can abe reilluminated by pressing the TR button ‘The LED automatically oes off ond the memory is ceored when the circuit breaker is reset, In normal condition, if push TR butlon, al indication LED is ON for esing auxiiory power ond LED. Biot oM Ulta clam (el) WiNbreak 2 MCCB Electronic Trip Units (Multifunction) ETM33 for CS400, CS630 ETM43 for CS800 Short circuit protection The short circuit threshold, Is is @ multiple of the overload seting, Ie Setting example 05 0s 07 08 09 1 08085 09 095. 4 CXEEXEEEXEETT) . The brooke rips when the ‘current exceeds 14404 Short circuit time delay ofthe neural conductor. Ifthe sum of ese values excaeds the set current threshold fo @ period of ime oreater thon the tine delay the Breaker is ripped 01.048 FL OFF son faul threshold 1a = earth fouit ime delay Electronic Trip Units (Multifunction) ETM33 for CS400, CS630 ETM43 for CS800 Ammeter (A), optional ‘The ammeter device hos on occuracy of + 10% ‘The highest chose current is deplayed in upp ne Inunder line, R Sond T phase currents serled tom. ‘Ammeter display limits: minimum current > 0.3 x In (one phose) tmorinurn current < 10 xn Zone selective interlocking (ZS1), optional Zone selective Inleriocking is mainly used in systems wth high roted current and short circuit current values, ‘with soley ond sevice canlinuily wequirements. This ype of discrimination can be ochived with cireut breokers equipped with specially designed electronic tip unite (ETM for CS circuit breaker), Zone selective interlocking (ZS! is @ system designe ‘te reduce the stress on electiceldisibution components during short-circuit or earth fault conditions ‘reduce the Wipping times (Lower then hundred milliseconds) + to reduce the damage caused by the fault and of inleferences tothe power supply system; A number of crcult breakers are interconnected one after another by a pilot-wire. Power source: DC24V Power is required. Operation + With 251, ETM trp unit detects the fault and send the signal to upsteom circuit breaker which applies the set ime delay and ignore its present shorime ond or/ earth fav} delay and clear the foult wih no intentional delay ‘With 251, ETM nip unit detects the faut and hen trips the ceuit breaker with intentional delay Intenionol Intentional delay: 0.2s doloy: 0.2 vasa eae BD ceo Inertocing Instontaneous| Arete imam] WiNbreak 2 MCCB Electronic Trip Units (Multifunction) ETM33 for CS400, CS630 ETM43 for CS800 Communication(€), optional Communication interface : RS485 (Modbus-RTU) ‘The Modbus RS4B5 system i an open bus on which communicating Modbus devices ore insailed. Al kins ol PLCs ond computers can be connec fo the bus. Transmitted date + Protection setting values + Highest current ofthe three phases + Measurement: 5, Tand N phase current + Foul odin: Type of foul (Overload, short-circuit te.) The setting of communication address using TR button and LCD display (ammeter) Power source: DC24V Power is required. Communication(C), optional DA (ammeter DZ /Ammete) DE [Eorh ful protection) §—-sDUZ+A Dae OZe DA+C (Commonication) DrtAte DAtErc Ozaic OztAtErc Menu structure of the electronic trip unit (ETM) Display current value (RMS) of phase whieh scoring Ur|-|4]2/6|0/A|— mosimum in eoch phose 1 16[5|A|— Diep currnt value (RMS) of eoch phote ot on intervel of every 2 seconds Press “TR” button for 5 seconds. The cursor in the First row ie Fickoing ofan interval of every 0.5 seconds Whenever pressing “TR” buon, the number will change from Tio 247, Press “TR” button for 4 seconds. ‘The cursor in the second row i Fickering ot an interval of every 5 seconds, Sarna lela tes The value set by monufachrer according 1 customer's order speciation =/1|2/6.0,4) For saving setting value, press “TR” button for 5 secor = gla] The the LCD return to Armetr faction, ETM33 A+E ETM33 A+E+C ETM33 Z+A+E ETM33 Z+A+E+C £TM33 A ETM33 A+C ETM33 Z+A ETM33 Z+A+C ETM33 E ETM33 Z+E ETM33 ETM33 Z Electronic Trip Units (Multifunction) ETM33 for CS400, CS630 ETM43 for CS800 Feature of trip unit according to option faites In 630A ee sere xi. TA (Ammar) DE (Ear fovb protection) D.C (Communication) 12 one Select) MCCBs for Power Distribution WiNbreak 2 MCCB “aeoeon 3 ‘ae a 00 0 Fae soe reing acy ks Pia Fa au ocion | ene secre rckig, 257 | arnt Communion mad ‘eoan0872 0000 120 1086 120% 140 86 ‘Apptcaie wo MoE eqsppes wan FTU, FMU, ATU SEIS Ean dot tame sce + 700A oy vata for CS600FTY ‘Avail for spe creut rsaars rd Developme veceo007 2 eoso0472 “(Onion ‘(Onion “AOpen ‘(Open “a(Opton) "4018086 26 185260570 72 od PNT WiNbreak 2 MCCB Electrical auxiliaries Alarm switch (AX) ‘Auilory switch is for applicctions requiring remote “ON” ond “OFF” indication. Each snitch contains wo contacts having a common connection (One is open and the other closed when the circuit breaker is open, and vice-versa, Alarm switch (AL) Alarm switches offer provisions for immediote audio or visual indication of tripped breaker due to ‘overload, shon iru, shun! tip, or undervoltage release condions. They are paticotory usetl in ovtomated plonts where operators mus! be signaled about changes inthe electrical distiouion system, This awich features a closed contact when the circuit breaker is twpped ‘utomatically In other words, thie swich does no! function when the breaker is operated monvaly. te contact open when the ict breaker is reel Fault alarm switch (FAL) FAL Indicoes thal the breaker hos ripped ds to overload or short circuit. ‘And, it can be applied 10 only ceuit breakers with eleconic Wp uni Undervoltage release, UVT ‘The undecveltage releose automatically opens 9 circuit breaker when vologe drops o © vale ronging between 35% 19 70% ofthe line vollge. The opercton i insontoneous, and afer wipping, the cial breaker cannot be re-dosed agein un the vologe etuns fo 85% of ie vokage. Continuously energized, the undervetlage ‘lease mus! be operating before the civil breaker can be closed. The undervotage release con be easily installed inthe lef accessory compares of the WiNbreck 2 CD ond CS cru. Brecker Range of ripping wotage: 0.35 ~ 0.7 Vn [MCB making is possible vellage: 0.85 Vn (exceed) + Frequency (only AC): 45 He ~ 65 He Shunt release, SHT The shunt release opens the mechan in response 1 on externally oped voltage signol. The releases inchde ‘cil lacing canted that automaticaly clear he signe creut when the mechanism has ripped. The shunt releore con be installed inthe oft accessory comporiment of he WiNbreak 2 CD & CS crt breokes + Range of operational voiage: 0.7 ~ 1.4 Vn + Froquancy (only AC): ASH2 ~ 65H2 02D EEE IE 'SSSSSS SSS Rotary handles ‘The ‘olary hendle operating mechanism is available in ether the direct version orn the extended version on the compartment door In is elwoys fied with @ compariment door lock and on a request i can be supplied with @ key lock i the ‘pen poston Direct rotary handles D100, cD160 DH (€8100, C3160, €3250, #2 ‘€S409, C5630 HS csa00 He Direct rotary handles with a key lock <<) (EERE SST i aa a non } C8400, C5630 ‘DHK3 Lock in On or OF position Vee csa00 DHKA [tock in On or OF postion Extended rotary handles D100, co160, eH 3100, C3160, €5250 eH ¢s400, C3620 Ha ‘cs800 ea dence olay handles, «=< —000_ SSIES Degree of protections Gircit breaker with cover frame and The acess probe of 1.0mm ary direct handle fameter shal not penetrate, 40 Wire Circuit becker wih caver “#01 direct hana lamer shall not pent frome and rotor direct hanile ‘oaly protected Cireitbreokor wth cover Fame ond) again nares of rotary exended handle st ond water els rom | 65 Wire ‘any dvecion Circuit breaker with cover frome ‘od etry extended hare DNL Tela (1) WiNbreak 2 MCCB Locking devices Removable locking device Removable locking device is ovilable for all CD & CS ctcuit breakers (> The locking device's designed tobe easily otfachad lo the crcuitbreaker ‘This device allows the handle 1 be locked inthe “ON ond “OFF poston t Locking in the OFF postion quorontee isolation according ¥o IEC 60947-2, ‘The locking device forthe toggle handle con be installed in 3-pole and 4-p0le circuit breakers ‘Marmara vee (3) padlocks with shackle diameters canging fram 5 to Bm may be vied (Padlocks are not supplied) ccp100, C0160 co “OFF* postion 5100, C5140, C5250 ra OFF" postion (c5400, €8630 Po “OFF” postion a) Pa “OFF” poston Fixed locking device Fined locking davice is avilable forall CD & CS ciruit breakers. This dovice allows the hondle to be locked inthe “ON” ond "OFF" positon Locking in the OFF position querantee isolation eccording to IEC 60947-2, The locking device forthe toggle hondle con be insole in 3-pole and 4-pole circuit breakers. ‘Maximum tes (3) padlocks wth shackle diameters ronging from 5 fo mm moy be used (Palocke ere not supplies) ‘€0100, €D140 PHL Lock in Offer On position €$100, C5160, C5250 = PHL |__ Leek in Off or On position $400, €5630 Pao Lock in Off or On position €8800 Pra I Lock in Off or On position Locking by rotary handle with a key lock ‘locking can be done by using the rotary handle which has key lock device. The lock ie used to lack the circuit breaker in the OFF postion The hey con only be removed when the ceui-breaker isn the OFF position, The key cannot be removed when the rotary handle isin the ON postion 100, co160 [ DEK) Lock in Of positon ‘$100, €8160, €5250 <., ee Lock in Off position (cs4o0, cs690 DRKS Leck in Off positon cs200 DKA 7 Lock in OF positon Terminals Front connection Terminol mesnter wm Trtuppled wit Whack 2 MCCB: os on stndord por of crv breaker | Connehng pt wi rina fr bus bo, cable wih og ' __cp10o,cpro_ | { GSi00, 5160, C5250 cae ‘C5400, c5C630 : ‘es800 4 Inner box terminal ore cable connectors for WiNbreak 2 CD ond CS series ete! breaker @ {Cam be used for both aluminum and copper cables y Umm) 1 8 IBT3, 3. ser GEA) 0100, 160 1 Simmiieu/at 25-95 era 4 [tet een Tightening torque [kafem) 308 Slo) 2 20 3 100, 160,250 | B28 Slown }Cu/Al 10-150 De ee Tightening torque (kglem) 906 Lew) 30 rs! SimmICu/Al 70-300 Tightening torque kgem) 367-428 | wrsa 3 | tee 98) ters 4 | tset EA), cs400, 630 Extended box terminals (Copper cables/bars and aluminum cables)! “The extended box lerminals for CD ond CS cireuit rear can be vied copper cabes/bors and elumioum cobles ‘There ore feur (4) kinds of terminal evecomecer ] ue 8 ‘ ve coven, 140 | ON oN |_| Sims 25-95 Tihering tue lend 206 nN Umm) 4 8100, 160, 250 ag ° || StGen) 1 ‘S(mm’}Cu/Al 10-150 ee aa Tightening torque kalem) 306 sewer Ec gay aa teeny | Hm a , ee SomiCu 85 to 2s Tahering longue hen) 67~428 BTS | 3 | Set (SEA) Lise a 5800 corse | 4 venuey 2 | Slr iGu/Al 3185 to 3240 Tightening torque kghen) 367 28 Une) 33 or 62 Accessories WiNbreak 2 MCCB Terminals P42. Front connection Spreaders 1 ) ‘Azan optional por of crevit breaker O10, OF ‘Con increase the ph of he lerminals i 2p SPiza | SP 120 co100 SP SPISaSPI3H 350 50 30530 0160 4P | SPiaa | SPrao csio0 2 SP22a | S220 ag 450 450 cso P| SP2aa | SP2a0 a0 | 10 aga 525 525 5 cs250 P| SP24a | SP2ab i 2p | sPaza | spa 525 525 . P| SPa3a | SP320 10 | 540 700 | 700 cséo0 P| SPSta | SPaAD ses) 2p) SPS sp SPSESa 465 a0 4P 2P eseoo ae 700 as. ap . Reer connection Rear connection lerminas are vd to adapt WiNbveok 2 CD and CS circu breakers to sichboards of ‘ther application hot require rear connection These can be connected direlly 9 dieu breakers without any medication There ore to kinds of rear onnection temina Frat ype Round the Flot vertical erin ‘co19960160 Rrbi2 TBI TBI cestco 90 Free raga ree ‘ose00 RIB Tea rea me Found teased terminals ome ercocoren RTRI2 TRI rms “ cstoocsieocses0 TR22 TR errs 1 cesao0| al Plug-indevice It be inseled directly onthe back plete of pore Sgetine Siegeine co100,co160 —= Dove re Singe ine Dovel ne ‘Singeine Sing ne ‘Single ne ‘singe na Single nw Single ne cesi00.cs160,c82s0 estan, 8600 The alain bose is he fixed prt a he plug-in version ofthe cruit baker Pare Pare Cr ax202 Paver Pars02 | Pee ~PBee Pax Paw Paes The cuit breaker rocked out by unscrewing the fop ond boom ing sree ‘ Piugrin bose mokes it possible 0 cxract and/or ropilyreplce he circu breaker wih out Raving to oven connecton for thip ond imperonineellone Foraiabton boars ‘mouning piste rearing a ‘mouning pate Insaling ont rontftbe naling on he font he nealing onthe backof he nealing one back tte mourning ral Accessories WiNbreak 2 MCCB Locking devices Mechanical interlocking device The meenonicol interlock (tl) ean be opplid on tho front of two breakers mounted ide by sido = Ther iecing ote lov irtloon of potted fate poton. pnb of ch ‘This chorea inrocking devin is very wal ond simple for coneising of manuel source changeover sem, ar = ENE ee ~ ¥ ‘S-pole Remote operation Motor operator Motor eperators con also be opercie by moral The motor drives 6 mechanism which swiches (CD & CS toggle handle to the “ON” ond “OFF/RESET” postions + The monval ecuctor handles located onthe fort a he cover + Manuel or Automate operation con be selected The moter eperato ison esenil device for consiucing o remcte operated avert source ctergroe sen eens ocninuos sep of eel poner lawing cain + Commercial installation tke Hossa, High ise building, Barks, Shopping Malls, Metros ee + Industrial nsllotion ike Ships, Por, Pracess Industries, RoiwoysMilfory ses ek ‘01 TS2SON th B00 osa(oceyy 100,60 | MOP 2 AC 100-240V/ 310 | 20 5000 | 120 ewonany | 058140) cest00, 160.250 | wore oo 05ND ceszon.es0 | Mors 2M) sop | a0 a mM | po tiov 2a uC) csa00 | wore” 700 | 420 9 © Y0000 | 20, Wiring Diagram WiNbreak 2 MCCB Motor operator Standard connection ‘Greit beaker On ond OF controled by remote operation end menual operation Connection with alarm switeh (AL) 1) The below connection diagrom is the method of using olaim switch (AL) without shunt or undervoltge rip. 2 After learing the foul surely, monval resets mandatory incase of inping due fo an eockical foul. Connection with FAL (Circuit breakers with ETS) 1) The below connec diogram ithe method of uring FAL for circuit breaker with alcronie rip unit 2} Alor dering th fel surly, monval resets mandatory incase of tipping due Yo an secricel faut Te Wiring Diagram (For Electronic trip Units-Multi Function) ‘The diagram is shown inthe following conditions: + Feed version crcuitbreaker(Sepending on type of cruit-breoker) + Circuit breakers open + Releases not ripped yueB nue aaa ae t + : | | ] | 3 fora | ers | e133 4 he “woe gle re rater an “Teepe eet rehar wh ETSERETERETSE acre lace TWAT cron ase (coral neta curert arsine) Characteristics curves WiNbreak 2 MCCB Circuit breakers with thermal-magnetic trip units 16~1004 T Wr ft t -xNomal unetin i)

You might also like