You are on page 1of 12

SK460-8/480LC-8

Electrical Equipment-2
<contents>
1、Equipment arrangement-Pump room
2、Pump room electric arrangement
3、Pump proportion valve
4、High pressure sensor
5、Hyd, temperature sensor
6、SOL block
7、Travel straight unload SOL
8、Radiator coolant level SW

1
1、Arrangement

High pressure sensor


PSV

Hyd. Temp. senor

SV・PSV

Low pressure sensor

Coolant level sensor

2
2、Main pump equipment

PSV-P1: PSV-P2:
Pump proportion valve Pump proportion valve

SE-23:
High pressure sensor

3
3-1、Pump proportional valve

13t~80t Common Parts:YN35V00052F2

4
3-2、Change of pump proportional valve

13t~80t Change of proportional valve

YN35V00052F1 → YN35V00052F2

<Back ground>
Big pulse generation is done to the second pump
proportion valve pressure at the high temperature.

Output shortage generation by


flowing quantity decrease
Change of shape of spool
Allophone generation by pulse spread
:YN35V00052F2

5
4、High Pressure sensor

Tightening torque 73.5N

20t~40t Common Parts:LC52S00015P1

6
5-1、Warning Hyd. Temp (running change)

Service diagnosis No.10

・ Warning Hyd. Temp

Prevent of hydraulic equipment Error code


damaged by the hyd. oil of the “W012”
high temperature. <High temperature>
Application S/No
LS11-02558~
7
YS11-02061~
5-1、Warning Hyd. Temp (running change)

Externals

Resistivity
Suction line

8
6-1、SOL Block

Lever lock
Arm 2 speed
Swing parking

Travel 1,2 speed P1 By Pass Cut


Attachment boost
Travel straight 9
P2 By Pass Cut
6-2、SOL Block
PSV PSV SV SV
YN35V00049F1 YN35V00048F1 YN35V00050F1 YN35V00051F1
SV
YN35V00050F1

T2
P2 P1

Inverse proportional valve


10
7、Travel straight unload SOL

Located under C/V

Travel straight unload SOL

・For Drain Hyd. Pressure


『When Drain Hyd. Pressure, This
SOL move to Travel straight spool
for unload position.』

11
8、Coolant level switch
*13t・・・N/A
・Observational coolant level in Radiator *80t・・・Equipped sub tank

SW-27:Coolant level SW(20~40t common parts)


P/No:VHS8346015110A

To controller

To ground

12