You are on page 1of 17

BTS3900C

Hardware Description

Issue 01
Date 2020-01-20

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2021. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: https://www.huawei.com
Email: support@huawei.com

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. i


BTS3900C
Hardware Description Contents

Contents

1 BTS3900C Hardware Description......................................................................................... 1


1.1 Changes in BTS3900C Hardware Description................................................................................................................ 2
1.2 Exteriors of BTS3900C Cabinets......................................................................................................................................... 2
1.3 Components in BTS3900C Cabinets.................................................................................................................................. 4
1.4 Engineering Specifications of Cabinets for BTS3900C Base Stations.................................................................... 8

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. ii


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

1 BTS3900C Hardware Description

Overview
BTS3900C cabinets are classified into the BTS3900C (Ver.C) cabinet and BTS3900C
WCDMA cabinet. BTS3900C Hardware Description mainly describes the exteriors,
configurations, and engineering specifications of the two types of cabinets.

The RF modules for distributed base stations in this document include RRUs and
AAUs. The application scenarios, power distribution schemes, cable connections,
and cable installation of the RRUs and AAUs are the same. The following uses the
RRUs as an example.

The exteriors of components or cables in this document are for reference only. The
actual exteriors may be different.

NOTE

● Unless otherwise specified, in this document, LTE and eNodeB always include FDD, NB-IoT,
and TDD. In scenarios where they need to be distinguished, LTE FDD, LTE NB-IoT, and LTE
TDD are used. The same rules apply to eNodeB.
● Unless otherwise specified, in this document, NR and gNodeB always include FDD and TDD.
In scenarios where they need to be distinguished, NR FDD and NR TDD are used. The same
rules apply to gNodeB.
● In this document, "G" is short for GSM, "U" for UMTS, "L" for LTE FDD, "T" for LTE TDD, "M"
for LTE NB-IoT, and "N" for NR. In addition, "N (FDD)" is short for NR FDD and "N (TDD)" is
short for NR TDD.
● For details about the LampSite solution, see LampSite Base Station Hardware Description.
● For details about the power requirements and power distribution schemes of BTS3900C
cabinets, see corresponding "Power Requirements" and "Power Distribution Schemes"
sections in base station model sections.

Product Versions
The following table lists the product versions related to this document.

Product Name Solution Version Product Version

3900 series base stations SRAN8.0 and later V100R008C00 and later

5900 series base stations

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 1


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Intended Audience
This document is intended for:
● System engineers
● Base station installation engineers
● Site maintenance engineers

Organization
1.1 Changes in BTS3900C Hardware Description
This section describes the changes in BTS3900C Hardware Description.
1.2 Exteriors of BTS3900C Cabinets
This section describes the exteriors and dimensions of BTS3900C cabinets.
1.3 Components in BTS3900C Cabinets
This section describes modules and boards in BTS3900C AC cabinets and
BTS3900C DC cabinets.

1.1 Changes in BTS3900C Hardware Description


This section describes the changes in BTS3900C Hardware Description.

01 (2020-01-20)
This is the first commercial release.
This document is separated from the 3900 & 5900 Series Base Station Hardware
Description document and its content derives from the section "BTS3900C Cabinet
Description."
Compared with the section "BTS3900C Cabinet Description" in 3900 & 5900 Series
Base Station Hardware Description of Issue 18 (2019-03-25), this issue does not
include any new topics or changes, or exclude any topics.
Before the separation, compared with Issue 17 (2018-12-31), Issue 18
(2019-03-25) does not include any new topics or changes, or exclude any topics.

1.2 Exteriors of BTS3900C Cabinets


This section describes the exteriors and dimensions of BTS3900C cabinets.
The following figure shows the exteriors of BTS3900C cabinets.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 2


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Figure 1-1 Exteriors of BTS3900C cabinets

The following figure shows the dimensions of BTS3900C cabinets.

Figure 1-2 Dimensions of BTS3900C cabinets

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 3


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

1.3 Components in BTS3900C Cabinets


This section describes modules and boards in BTS3900C AC cabinets and
BTS3900C DC cabinets.

Components in a BTS3900C (Ver.C) AC Cabinet


The following figure shows the components in a BTS3900C (Ver.C) AC cabinet.

Figure 1-3 Components in a BTS3900C (Ver.C) AC cabinet

The following table lists the components in a BTS3900C (Ver.C) AC cabinet.

Table 1-1 Components in a BTS3900C (Ver.C) AC cabinet

No. Componen Man Maximu Remarks


t dator m
y/ Quantit
Opti y in a
onal Single
Cabinet

1 ELU Man 1 An electronic label unit (ELU) reports


dator the cabinet type automatically to
y facilitate troubleshooting.

2 PMU 11A Man 1 A power monitoring unit 11A (PMU


dator 11A) manages a power system,
y monitors power distribution, and
reports alarms.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 4


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

No. Componen Man Maximu Remarks


t dator m
y/ Quantit
Opti y in a
onal Single
Cabinet

3 HEUB Man 1 A heat exchange unit type B (HEUB)


dator provides power for fans, monitors the
y status of fans, collects cabinet
environment monitoring information
and power surge protection alarm
information, and reports the collected
information to a BBU.

4 PSU Man 2 A power supply unit (PSU) converts


(R4850G2) dator 110 V or 220 V AC power into -48 V
y DC power.

5 BBU Man 1 A BBU is a baseband unit and


dator processes the baseband signals of a
y base station. For details, see the
corresponding BBU hardware
description. For example, for the
BBU5900, see BBU5900 Hardware
Description.

6 FAU01D-01 Man 2 FAUs dissipate heat from a cabinet.


dator FAUs include an inner air circulation
y fan and an outer air circulation fan,
which are located on the inner upper
left wall and the inner lower left wall
of an OMB, respectively.

7 PDU10D-0 Man 1 A power distribution unit 10D-01


1 dator (PDU10D-01) distributes -48 V DC
y power to other components in a
cabinet.

8 RRU Man 1 An RRU subrack houses an RRU.


Subrack dator
y

9 RRUa Man 1 An RRU processes and transmits RF


dator signals between a BBU and an
y antenna system.

10 SPD Man 1 An AC surge protection box provides


dator surge protection for AC input power.
y

11 ETP48100- Man 1 It converts AC power into DC power.


A1 dator
y

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 5


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

No. Componen Man Maximu Remarks


t dator m
y/ Quantit
Opti y in a
onal Single
Cabinet

a: A BTS3900C (Ver.C) supports the following RRUs: RRU3804, RRU3801E,


RRU3908 V1, RRU3908 V2, RRU3928, RRU3808, RRU3929, RRU3942, RRU3828,
RRU3829, RRU3806, and RRU3926.

Components in a BTS3900C (Ver.C) DC Cabinet


The following figure shows the components in a BTS3900C (Ver.C) DC cabinet.

Figure 1-4 Components in a BTS3900C (Ver.C) DC cabinet

The following table lists the components in a BTS3900C (Ver.C) DC cabinet.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 6


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Table 1-2 Components in a BTS3900C (Ver.C) DC cabinet


No. Componen Man Maximu Remarks
t dator m
y/ Quantit
Opti y in a
onal Single
Cabinet

1 ELU Man 1 An ELU reports the cabinet type


dator automatically to facilitate
y troubleshooting.

2 HEUB Man 1 An HEUB provides power for fans,


dator monitors the status of fans, collects
y cabinet environment monitoring
information and power surge
protection alarm information, and
reports the collected information to a
BBU.

3 BBU Man 1 A BBU is a baseband unit and


dator processes the baseband signals of a
y base station. For details, see the
corresponding BBU hardware
description. For example, for the
BBU5900, see BBU5900 Hardware
Description.

4 FAU01D-01 Man 2 FAUs dissipate heat from a cabinet.


dator FAUs include an inner air circulation
y fan and an outer air circulation fan,
which are located on the inner upper
left wall and the inner lower left wall
of an OMB, respectively.

5 RRU Man 1 An RRU subrack houses an RRU.


Subrack dator
y

6 RRUa Man 1 An RRU processes and transmits RF


dator signals between a BBU and an
y antenna system.

7 PDU10D-0 Man 1 A PDU10D-01 distributes -48 V DC


1 dator power to other components in a
y cabinet.

a: A BTS3900C (Ver.C) supports the following RRUs: RRU3804, RRU3801E,


RRU3908 V1, RRU3908 V2, RRU3928, RRU3808, RRU3929, RRU3942, RRU3828,
RRU3829, RRU3806, and RRU3926.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 7


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

1.4 Engineering Specifications of Cabinets for


BTS3900C Base Stations
Engineering specifications of cabinets for BTS3900C base stations include input
power specifications, equipment specifications, environmental specifications, surge
protection specifications of ports, and compliance standards.

Equipment Specifications
Table 1-3 lists the equipment specifications of a BTS3900C WCDMA cabinet. Table
1-4 lists the equipment specifications of a BTS3900C (Ver.C) cabinet.

Table 1-3 Equipment specifications of a BTS3900C WCDMA cabinet


Item Specifications

Dimensions (H x W x D) 600 mm x 400 mm x 390 mm (23.62


in. x 15.75 in. x 15.35 in.)
● OMB: 600 mm x 240 mm x 390 mm
(23.62 in. x 9.45 in. x 15.35 in.)
● RRU subrack: 600 mm x 160 mm x
390 mm (23.62 in. x 6.29 in. x 15.35
in.)

Weight ● AC cabinet: ≤ 28 kg (61.74 lb,


excluding the BBU and RRU)
● DC cabinet: ≤ 26 kg (57.33 lb,
excluding the BBU and RRU)

Heat dissipation capability of the The maximum heat dissipation


cabinet capability is 300 W when the ambient
temperature is 50°C (122°F).

Table 1-4 Equipment specifications of a BTS3900C (Ver.C) cabinet


Item Specifications

Dimensions (H x W x D) 600 mm x 420 mm x 430 mm (23.62


in. x 16.54 in. x 16.93 in.)
● OMB (Ver.C): 600 mm x 240 mm x
430 mm (23.62 in. x 9.45 in. x 16.93
in.)
● RRU subrack: 600 mm x 180 mm x
430 mm (23.62 in. x 7.08 in. x 16.93
in.)

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 8


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Item Specifications

Weight ● AC cabinet: ≤ 32 kg (70.56 lb,


excluding the BBU and RRU)
● DC cabinet: ≤ 28 kg (61.74 lb,
excluding the BBU and RRU)

Heat dissipation capability of the The maximum heat dissipation


cabinet capability is 650 W when the ambient
temperature is 50°C (122°F).

Environmental Specifications
Table 1-5 lists environmental specifications of a BTS3900C WCDMA cabinet. Table
1-6 lists environmental specifications of a BTS3900C (Ver.C) cabinet.

Table 1-5 Environmental specifications of a BTS3900C WCDMA cabinet


Item Specifications

Operating temperature ● With solar radiation: -40°C to +45°C


(-40°F to +113°F)
● Without solar radiation: -40°C to
+50°C (-40°F to +122°F)

Relative humidity 5% RH to 100% RH

Atmospheric pressure ≤ 4000 m (13123.36 ft)

Noise sound power level ETS 300 753 4.1E (Rural)


● ≤ 6.1 bels@+25°C (77°F)
● ≤ 6.7 bels@+45°C (113°F)

Ingress protection rating IP55

Storage environmenta ETSI EN 300019-1-1 V2.1.4 (2003-04)


Class 1.2 "Weather protected, not
temperature-controlled storage
locations"

a: Regarding the storage environment:


● The validity period is one year.
● The product can function properly within the validity period if the storage
environment meets the preceding standards.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 9


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Table 1-6 Environmental specifications of a BTS3900C (Ver.C) cabinet


Item Specifications

Operating temperature -33°C to +50°C (-27.4°F to +122°F)

Relative humidity 5% RH to 100% RH

Atmospheric pressure ≤ 4000 m (13123.36 ft)

Noise sound power level ● When the heat consumption of the


base station is lower than or equal
to 300 W, the noise sound power
level complies with the ETS 300 753
4.1E (Rural) standard.
– ≤ 6.1 bels@+25°C (77°F)
– ≤ 6.7 bels@+45°C (113°F)
● When the heat consumption of the
base station is higher than 300 W,
the noise sound power level
complies with the ETS 300 753 4.1E
(Urban) standard.
– ≤ 6.6 bels@+25°C (77°F)
– ≤ 7.6 bels@+45°C (113°F)

Ingress protection rating IP55

Storage environmenta ETSI EN 300019-1-1 V2.1.4 (2003-04)


Class 1.2 "Weather protected, not
temperature-controlled storage
locations"

a: Regarding the storage environment:


● The validity period is one year.
● The product can function properly within the validity period if the storage
environment meets the preceding standards.

Surge Protection Specifications


Table 1-7 lists the surge protection specifications of ports in a BTS3900C WCDMA
cabinet. Table 1-8 lists the surge protection specifications of ports in a BTS3900C
(Ver.C) cabinet.

NOTE

● Unless otherwise specified, the surge protection specifications depend on the surge
waveform of 8/20 μs.
● All the surge current items, unless otherwise specified as Maximum discharge current, refer
to Nominal discharge current.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 10


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Table 1-7 Surge protection specifications of ports in a BTS3900C WCDMA cabinet


Item Specifications

Surge protection specifications of Surge current: 15 kAa


ports
Surge current: 30 kAb

a: DC power port
b: AC power port

Table 1-8 Surge protection specifications of ports in a BTS3900C (Ver.C) cabinet


Item Specifications

Surge protection specifications of Surge current: 20 kAa


ports
Surge current: 30 kAb

a: DC power port
b: AC power port

Compliance Standards
The BTS3900C WCDMA and BTS3900C (Ver.C) cabinets comply with the same
standards, as provided in the following table.

Table 1-9 Compliance standards for a BTS3900C WCDMA/BTS3900C (Ver.C)


cabinet
Item Standard

Security ● X.509: Supported in GBSS14.0/RAN14.0/eRAN3.0/SRAN7.0 and


standard later versions
s ● RFC 1825: Supported in GBSS14.0/RAN14.0/eRAN3.0/SRAN7.0
and later versions
● RFC 1826: Supported in GBSS14.0/RAN14.0/eRAN3.0/SRAN7.0
and later versions
● RFC 1827: Supported in GBSS14.0/RAN14.0/eRAN3.0/SRAN7.0
and later versions
● RFC 4492: Supported in all versions
● RFC 5246: Supported in GBSS15.0/RAN15.0/eRAN6.0/SRAN8.0
and later versions
● Secure Socket Layer (SSL): Supported in all versions

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 11


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Item Standard

Operatin ETS 300 019-1-4 Class 4.1


g
environ
ment

Storage ETSI EN 300019-1-1 V2.1.4 (2003-04) Class 1.2 "Weather protected,


environ not temperature-controlled storage locations"
menta

Transpor ETSI EN300019-1-2V2.1.4 (2003-04) class 2.3 "Public transportation"


tation
environ
ment

Shockpro IEC 60068-2-57: Environmental testing - Part 2-57: Tests - Test Ff:
of Vibration - Time-history method
protectio YD5083: Interim Provisions for Test of Anti-seismic Performances of
n Telecommunications Equipment (telecom industry standard in
People's Republic of China)

Anti- ETSI EN 300019-1-4: "Earthquake"


earthqua
ke
performa
nce

Noise ● ETS 300 753 4.1E (Rural)


● ETS 300 753 4.1E (Urban)

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 12


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Item Standard

EMCb A multimode base station complies with the following standards:


● R&TTE Directive 1999/5/EC
● R&TTE Directive 89/336/EEC
● ETSI EN 301489-1/8/23
● 3GPP TS 25.113
● ETSI EN 301908-1
● ITU-T SM 329-10
● FCC PART15
A NodeB has been certified by European standards and complies
with the following standards:
● CISPR 22 (1997)
● EN 55022 (1998)
● EN 301 489-23 V1.2.1 (2002-11)
● CISPR 24 (1998)
● IEC 61000-4-2
● IEC 61000-4-3
● IEC 61000-4-4
● IEC 61000-4-5
● IEC 61000-4-6
● IEC 61000-4-29
● GB 9254-1998
● ETSI 301 489-1 V1.3.1 (2001-09)
● FCC Part 15

Surge ● IEC 62305-1 Protection against lightning - Part 1: General


protectio principles
n ● IEC 62305-3 Protection against lightning - Part 3: Physical
damage to structures and life hazard
● IEC 62305-4 Protection against lightning - Part 4: Electrical and
electronic systems within structures
● ITU-T K.35 Bonding configurations and earthing at remote
electronic sites
● ITU-T K.56 Protection of radio base stations against lightning
discharges
● ITU-T K.97 Lightning protection of distributed base stations
● ETSI EN 300 253 Environmental Engineering (EE): Earthing and
bonding configuration inside telecommunications centers
● YD/T 2324-2011: Lightning protection requirements and test
methods for radio base stations
● GB 50689-2011: Code for design of lightning protection and
earthing engineering for telecommunication bureaus (stations)

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 13


BTS3900C
Hardware Description 1 BTS3900C Hardware Description

Item Standard

a: Regarding the storage environment:


● The validity period is one year.
● The product can function properly within the validity period if the storage
environment meets the preceding standards.
b: The BTS3900C complies with the following standards. If interference exists
because the cabinet is installed near antennas or other wireless receivers, you
are advised to extend the distance between them or adjust the location and
direction of antennas.

Issue 01 (2020-01-20) Copyright © Huawei Technologies Co., Ltd. 14