You are on page 1of 2

Propaq MD ®

All the Advantages of a Propaq Monitor with a Defibrillator

The Propaq® MD was specifically designed to meet the needs of the military and air
medical operations when treating critical patients in the field. It combines the well-
accepted and proven monitoring capabilities of the Propaq monitor with the clinically
superior therapeutic capabilities of ZOLL defibrillation and non-invasive pacing
technologies—at half the size of other monitor/defibrillators.
Propaq MD Specifications
Defibrillator Print Modes: Manual or automatic Microstream® etCO2
Waveform: Rectilinear BiphasicTM (user configurable) Range:
Energy Selections: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, On/Off Control: Front panel or paddle 0 – 150 mmHg
30, 50, 70, 85, 100, 120, 150, 200 joules Paper Delay: 6 seconds Accuracy (mmHg):
Energy Display: Monitor display indicates both Frequency Response: Same as the 0 – 38: ± 2 mmHg
selected and delivered energy. monitor’s settings 39 – 150: ± 5 % + .08% /mmHg >38
Charge Time: < 7 seconds to 200 J, typical Paper Width: 80 mm Respiration Range: 0 – 149 breaths per minute
Charge Controls: Control on apex paddle and on Respiration Rate Accuracy:
device front panel. Masimo® rainbow® SET SpO2 0 – 70 BPM: ±1 BPM
Paddles: External anterior/anterior adult and pediatric. 71 – 120 BPM: ±2 BPM
Saturation Range: 1 – 100%
Propaq MD Adult paddles slide off to expose pediatric paddles. Saturation Accuracy:
121 – 149 BPM: ±3 BPM
Compatible with ZOLL external paddles Flow Rate: 50 ml/min -7.5 + 15 ml/min
Smallest, Lightest, Most (8000-1010-01), ZOLL internal paddles, and the
Oxygen saturation during no-motion conditions:
Propaq MD multi-function therapy cable. Adults, Pediatrics: 70 – 100%, ± 2 digits ECG Impedance Respiration
Advanced Monitor/ Synchronized Mode: Synchronizes defibrillator pulse
0 – 69%, unspecified
User-Selectable Leads: RA-LA, RA-LL
Neonates: 70 – 100%, ± 3 digits
to patient’s R-wave. “SYNC” message displayed on Breath Rate Range:
Defibrillator Available monitor. Marker on display and on recorder paper
0 – 69%, unspecified
Oxygen saturation during motion conditions: Adult/Pediatric modes: 2 – 150 RPM
identifies R-wave discharge point. Adults, Pediatrics: 70 – 100%, ± 3 digits
Built-In Defibrillator Tester: Tests defibrillator energy Neonate mode: 3 – 150 RPM
0 – 69%, unspecified Respiration Rate Accuracy: ± 2
• 
Robust communications options: output and continuity of universal cable and paddles. Neonates: 70 – 100%, ± 3 digits breaths/min or ± 2%
integrated Wi-Fi, Bluetooth® Modes: AED function with manual override,
manual defibrillation.
0 – 69%, unspecified
Sweep Speed: 3.13, 6.25, 12.5 mm/sec
Oxygen saturation during low-perfusion conditions:
with USB cellular modem, and Adults, Pediatrics 70 – 100%, ± 2 digits
CPR Feedback Technology 0 – 69%, unspecified Invasive Pressure
Ethernet capabilities. See-Thru CPR®: Artifact filtering Neonates, 70 – 100%, ± 3 digits Three channels
0 – 69%, unspecified Pressure Range: -30 – 300 mmHg
Real CPR Help®: Real-time depth and rate feedback
• 
60% smaller and 40% Pulse Rate Range: 25 – 240 bpm Pulse Rate Measurement Range: 25 – 250 BPM
CPR Dashboard™: Numeric readout of depth and Pulse rate during no-motion conditions:
lighter than other similar rate, release indicator, perfusion performance Adults, Pediatrics, Formats: S/D, S/D (M), (M) user selectable
indicator (PPI) Neonates: 25 – 240 ± 3 digits User-Selectable Labels: P1, P2, P3, ABP, AO, ART,
monitor/defibrillators. Pulse rate during motion conditions: CVP, BAP, FAP, LAP, PAP, RAP, UAP, UVP, ICP
External Pacer Adults, Pediatrics, Transducer Requirements: 5 μV/V/mmHg
• 
First critical care Type: External transcutaneous pacing Neonates: 25 – 240 ± 5 digits Zero Adjustment: ± 200 mmHg
monitor/ defibrillator to receive Pulse Types: Rectilinear, constant current SpO2 Average Time Setting: Numeric Pressure Accuracy: ± 2 mmHg or 2% of
Pulse Width: 40 ms ± 2 ms 4, 8 (default), 16 seconds reading, plus transducer error
the IP55 ingress protection rating Pacer Rate: 30 – 180 BPM ± 1.5% Transducer Connector: Standard 6 pin AAMI
Masimo rainbow® SET SpCO®
because of its ability to resist jets Output Current: 0 – 140 mA ± 5% or 5 mA
Modes: Demand and Fixed Range: 0 – 99% Temperature
of water and dust. Accuracy: 1 – 40% ± 3 digits Two YSI 400/700 compatible channels
Display Range: 0° – 50° C,
• 
Meets an unprecedented Type: Bright, Color, LCD TFT Masimo rainbow® SET SpMet® Units: °C or °F
number of military and Brightness: User adjustable Range: 0 – 99% Display: T1, T2, and Delta temp
Resolution: 640 x 480 pixels Accuracy: 1 – 15% ± 1 digits Accuracy: ± 0.1° C
airworthiness standards.
Waveform Traces: Up to 4 waveforms
Display Modes: Standard, High Contrast, NVG (night Masimo rainbow® SET SpHb® Power
• 
Only airworthy vision goggle) Friendly Measurement Range: 0 – 25 g/dL Rechargeable, user replaceable, lithium-ion battery
monitor/ defibrillator to offer Waveform Display Width: 11.5 cm Accuracy (Adults/Infants/Pediatrics): 8 – 17 g/dL Operating Time: 6 hours (display
+/- 1 g/dL brightness at 30%, ECG, Sp02, EtCO2, IPx3,
three invasive pressure channels, ECG: Resolution (SpHb g/dL): 0.1 g/dL Temp x2 and NIBP every 15 min, and 10 200-joule
necessary to monitor critical Cable Detection: Automatic 3-, 5-, 12-lead shocks)
Input: 3-lead cable, 5-lead cable, 12-lead cable, Masimo rainbow® SET SPOC™ Battery:
patients during long transports. paddles, therapy cable Measurement Range: 0 – 35 mL of O2/dL of blood Size: 182 mm x 95 mm x 31 mm
Cable Compatibility: Propaq Encore, Propaq CS Resolution: 01. ml/dL Weight: 1.36 lbs
•  Utilizes ZOLL’s SurePower™ Leads: I, II, III, AVR, AVL, AVF, V1 – V6
Battery Indicators: 5 battery capacity LED
indicators, fault indicator, recalibration indicator
II battery technology. A single Bandwidth: (User Selectable) Masimo Perfusion Index (PI) Recharge Rate: 4 hours to 100%
0.67 – 20 Hz Limited mode Measurement Range: 0.02 – 20% AC Power Adapter: 100-240 VAC 50, 60, 400 Hz
battery provides 6 hours of 0.67 – 40 Hz Monitor mode Resolution: 0.1% (@110V)
monitoring of all physiological 0.25 – 40 Hz Filtered Diagnostic mode
0.05 to 150 Hz Diagnostic mode Masimo Pleth Variability Index (PVI®) General
parameters: 12-lead ECG, NIBP, Heart Rate Range: 30 – 300 BPM Measurement Range: 0 – 100% Weight: 10.6 lbs. without paper and battery
EtCO2, SpO2, three invasive Heart Rate Accuracy: ± 3 BPM or 3% Resolution: 1% 11.7 lbs. with paper and battery
Pacer detection and display Dimensions: 8.9” x 10.4” x 7.9”
pressures, two temperature Electrosurgery interference suppression With soft handle: 8.9” x 8.75” x 7.9”
Noninvasive Blood Pressure (NIBP)
channels, and 10 200-joule ESU and defibrillation protected Smartcuf® and SureBP® NIBP technology
OneStep Pediatric Electrode Pads enable the ECG Sizes: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv, and Measurement Intervals: 1-, 2-, 3-, 5-, 10-, 15-, 30-, Environmental
shocks.
R Series to automatically adjust to proper auto-ranging and 60-minute, and manual Operating Temperature: 0° – 50° C
pediatric Sweep Speed: 25 mm/sec, 50 mm/sec Quick Action NIBP Start/Stop button Operating Relative Humidity: 15% – 95%, NC
•  Firstenergy levels.
transport Common Mode Rejection: Complies with AAMI Operating Altitude: Up to 15,000 ft
TurboCuf: 5 min of repeated NIBP readings
monitor/ defibrillator to offer EC13-2002 section 4.2.9.10. Systolic, diastolic, mean display Transport/Storage Temperature: -30° – 70° C
multiple display modes to operate On-screen manometer, with large numerics Shock: IEC 60068-2-27, 100g, 6ms half sine
Patient Modes: Cuff overpressure protection Drop:
in bright sunlight or during night User Selectable: Adult, Pediatric, Neonate. Typical Measurement Time: 1 meter per MIL STD 810G, Method 516-6, 26
Sets defaults for alarms, defibrillation energy, 30 – 45 secs (on deflation) drops,
missions (NVG-friendly display). and NIBP settings. 15 – 30 secs – SureBP (on inflation) EN 1789 30-inch functional drop,
Standard Cuff Sizes: Neonate #1 – #5, Infant, Child, 2 meter per IEC 60601-1
Available with Masimo rainbow®
•  Trends (on screen) Sm Adult, Adult Long, Lg Adult, Thigh
Tabular numeric format Vibration: MIL STD 810G, Method 514.6
SET SpO2, SpCO, SpMet, SpHb, All parameters trended/viewable
Default Cuff Inflation Pressure: 4.4.2 Procedure II,
Adult: 160 mmHg
SpOC, PI,and PVI. Trend Intervals: 1, 5, 10, 15, 30, 60 minutes Pediatric: 120 mmHg EN ISO 9919 per (IEC 60068-2.64)
Duration: 24 hours at 1-minute intervals Neonatal: 90 mmHg EN 1789 for ambulance RTCA/DO-160G (multiple
Snapshots: Minimum of 32 display data captures Pressure Measurement Range: helicopter frequencies)
Enclosure Protection: (IEC 60529)
ADVANCING (12 seconds of pre- and post-button press) Systolic: 20 – 260 mmHg
Quick Access Trend Display via Display Button Diastolic: 10 – 220 mmHg Solid Foreign Object: IP5X
R E S U S C I T A T I O N. Mean: 13 – 230 mmHg Water Ingress: IPX5
T O D A Y. ®
Printer Maximum Cuff Inflation Pressure:
Adult: 270 mmHg
Waveforms Printed: 1, 2, or 3 Pediatric: 170 mmHg
ZOLL Medical Corporation Print Speeds: 25 mm/sec or 50 mm/sec Neonatal: 130 mmHg
Worldwide Headquarters
269 Mill Road
Specifications subject to change without notice.
Chelmsford, MA 01824
©2015 ZOLL Medical Corporation. All rights reserved. Advancing Resuscitation. Today. CPR Dashboard, Real CPR Help, Rectilinear
978-421-9655 Biphasic, See-Thru CPR, SurePower tand ZOLL are trademarks or registered trademarks of ZOLL Medical Corporation in the United
800-804-4356 States and/or other countries. Propaq, Smartcuf and SureBP are registered trademarks of Welch Allyn. All other trademarks are the
property of their respective owners.
For subsidiary addresses and fax numbers, Masimo, Rainbow, SpO2, SpCO, SpMet, SpHb, SpOC, PVI, and PI are trademarks or registered trademarks of Masimo Corporation.
as well as other global locations, please Microstream is a registered trademark of Oridion Medical 1987 Ltd.
go to www.zoll.com/contacts.
Printed in the U.S.A. MCN MP 1508 0020