Unit 9 Review

1. Which of the following can cause tube Galvanic corrosion?


a) Dissimilar metals come in contact in the presence of
moisture
b) Similar metals come in contact in the presence of moisture
c) Similar metals come in contact in vacuum conditions
d) Dissimilar metals come in contact in vacuum conditions
2. What is the name of the shown chart?
a) System pressure chart
b) System acceptance chart
c) Galvanic chart
d) Maximum flow chart

3. Which of the following tube materials is suitable for low


temperature media?
a) Copper
b) Stainless steel
c) Carbon steel
d) Alloy 600
4. Which of the following tube materials is suitable for Extremely
high temperature media?
a) Alloy 600
b) Stainless steel
c) Carbon steel
d) Copper
5. What is the name of the shown fitting?
a) Union Tee
b) Male Tee
c) Female Tee
d) Quick connect Tee

6. What is the name of the shown fitting?


a) Straight quick connector
b) Equal union fitting
c) Male union
d) Female union

7. What is the name of the shown fitting?


a) Male Tee
b) Female Tee
c) Union Tee
d) Quick connect Tee
8. Which of the following is a Standard for Taper threads?
a) NPT
b) NPS
c) EMT
d) ANSI
9. Which of the following standard is used to select Piping material?
a) SAES-L-132
b) SAES-J-132
c) SATIP-W-011
d) SAES-J-200
10. What is the color identification for Instrument Air piping ?
a) Silver paint with green stripe paint
b) Red paint with yellow stripe paint
c) Green paint with yellow stripe paint
d) Blue paint with silver stripe paint
11. When selecting a stainless-steel compression type fitting,
which standard shall be used?
a) ISA RP 42.1
b) ANSI 4140.1
c) ASTM B55
d) ISA RA 25.5
12. Which of the following references is for Instrument Piping
and Tubing Systems Specifications?
a) PIP PCSIP001
b) PIP PCCIP001
c) SAES-J-100
d) SAES-J-300
13. For Header instrument air distribution system, what is the
pipe size must be installed if the number of users is more than
151?
a) 3 inch
b) 2 inch
c) 1.5 inch
d) 1 inch
14. For Header instrument air distribution system, what is the
pipe size must be installed if the number of users is less than 5?
a) 1/2 inch
b) 3/4 inch
c) 1 inch
d) 1.5 inch
15. For Header instrument air distribution system, what does
the pressure drop for piping between the dryer after-filter outlet
and the most remotely located user ?
a) < 35KPa
b) 35 KPa
c) 2 psi maximum
d) Minimum 6 psi
16. Which of the following is the requirements of pneumatic
signal tubing?
a) Shall be Type 316 seamless, 1/4-inch OD x 0.035-inch wall
thickness
b) Shall be Type 306 seamless, 1/2-inch OD x 0.035-inch wall
thickness
c) Shall be Type 316 seamless, 1/2-inch OD x 0.5-inch wall
thickness
d) Shall be Type 306 seamless, 1/4-inch OD x 0.035-inch wall
thickness
17. What is the maximum distance between Tubing supports ?
a) 4 feet
b) 2 feet
c) 7 fee
d) 6 feet
18. What is the minimum design pressure for Instrument
tubing?
a) 150 psig
b) 100 psig
c) 250 psig
d) 300 psig
19. How many spare takeoff fittings and block valves shall be
installed on the branch header?
a) 20%
b) 30%
c) 40%
d) 10%
20. For impulse line pressure test, which of the following is the
proper test condition?
a. 1.1 times design Pressure
b. 2 times design Pressure
c. 1.9 times design Pressure
d. 0.5 times design Pressure
21. For impulse line pressure test, which of the following is the
proper test condition in case of Vacuum service system?
a) Vacuum service systems to be checked at 30 PSIG unless
limited by a lower pressure design of the line
b) Vacuum service systems to be checked at 50 PSIG unless
limited by a lower pressure design of the line
c) Vacuum service systems to be checked at 100 PSIG unless
limited by a lower pressure design of the line
d) Vacuum service systems to be checked at 10 PSIG unless
limited by a lower pressure design of the line
22. Which of the following is considered as approved medium
used for the pressure test of the impulse lines?
a) Water
b) Hydrogen
c) Ammonia
d) Oil
23. What is the name of the shown figure?
a) Instrument Rack
b) Instrument Junction box
c) Instrument Panel
d) Instrument distribution panel
24. Which of the following provides cross wiring functionality
between field instruments and the control system?
a) Marshaling panels
b) Junction box
c) Pneumatic panels
d) Instrument Control Panels
25. What is the name of the shown figure?
a) Drain/Breather Plug
b) Fitting
c) Nipple
d) Bolt & Nut

26. What is the name of the shown figure?


a) Pneumatic panels
b) Instrument Junction box
c) Instrument Panel
d) Instrument Control Panels
27. Which of the following is the suitable environment for all
cabinets?
a) All cabinet equipment and wiring shall be designed for
continuous operation at 50 °C, and relative humidity 80%
maximum and 20% minimum.
b) All cabinet equipment and wiring shall be designed for
continuous operation at 20 °C, and relative humidity 70%
maximum and 20% minimum.
c) All cabinet equipment and wiring shall be designed for
continuous operation at 75 °C, and relative humidity 90%
maximum and 10% minimum.
d) All cabinet equipment and wiring shall be designed for
continuous operation at 35 °C, and relative humidity 30%
maximum and 25% minimum.
28. What is the spare capacity should be provided for terminal
blocks?
a) 20%
b) 30%
c) 40%
d) 5%
29. What is the spare capacity should be provided for Relays if it
exceeds 10 in the panel?
a) 10%
b) 20%
c) 30%
d) 5%
30. Which of the following is the suitable environment for
outdoor cabinets?
a) Minimum 5% - Maximum 95%
b) Minimum 50% - Maximum 95%
c) Minimum 25% - Maximum 75%
d) Minimum 15% - Maximum 75%
31. What is the minimum accepted swinging angle of any door
of a cabinet?
a) 90 degree
b) 145 degree
c) 120 degree
d) 45 degree
32. Which of the following is the accepted nominal pull in
voltage for a relay coil installed in an instrument panel?
a) <85%
b) <25%
c) >85%
d) Between 25% to 50 %
33. What is the standard color code for ON/OPEN push button
or light?
a) Green
b) Red
c) Amber
d) Yellow
34. What is the standard color code for OFF/CLOSE push button
or light?
a) Red
b) Green
c) White
d) Yellow
35. What is the maximum width of an enclosure door?
a) 900 mm
b) 500 mm
c) 1200 mm
d) 700 mm
36. Which Junction box is requirement in corrosive area?
a) NEMA TYPE 4X IN ACCRONDING TO IEC 60529 AND IP 66
b) NEMA TYPE 3X IN ACCRONDING TO IEC 60529 AND IP 03
c) NEMA TYPE 3X IN ACCRONDING TO IEC 60529 AND IP 66
d) NEMA TYPE 2X IN ACCRONDING TO IEC 60529 AND IP 23
37. Which of the following in NOT correct about pre-
commissioning of Junction boxes?
a) Junction boxes shall be at the same level of the floor grade
and sealed against the free entrance of water or concrete
b) Junction boxes shall be leveled to the floor grade and sealed
against the free entrance of water or concrete
c) Junction boxes shall be of metal and shall be mechanically
and electrically continuous with the header
d) A minimum horizontal working space of 762 mm (30 in.)
shall be provided
38. Which of the following is protected against power Jets from
any direction as well as total protection against ingress of any
dust?
a) IP66
b) IP56
c) IP65
d) IP58
39. For IP67, what does number 6 means?
a) Total protection against the ingress of any dust.
b) Protection from entry by tools, wires etc., with a diameter of
2.5 mm or more.
c) Protection against solid bodies larger than 1mm (e.g., fine
tools/small etc.).
d) Protected against dust that may harm equipment.
40. For IP01, what does number 0 means?
a) No protection at all against solid objects
b) Totally dust tight.
c) Protected against dust that may harm equipment.
d) Protection against condensation.