To answer: Click on the empty cell below to activate the drop-down menu to fill in your choice.
Use "delete" to erase answers.
Why is there only a 5mm gap allowed between the air baffle plate and the bulkhead panel?
a.) Unit will not pass PTI with a larger gap.
b.) A gap beyond 5mm may constrain proper airflow.
c.) Baffle plate will lose structural integrity when the gap is more than 5mm
d.) Cargo and/or its packaging might get stuck in a larger gap.
Choose the right statement:
a.) If a top rail insert would end within 150mm of another vertical weld, it must be extended to the nearest
corner fitting.
b.) There is no limitation on the maximum amount of inserts in a corner post.
c.) If a section in a bottom side rail would end within 300mm of a corner fitting, it must be extended to that
fitting.
d.) Minor cracks and gouges to the T-floor upper T-flange do not require repair.
T-floor upper flange damages (gouges or missing material) greater than 50mm and up to 300mm in
length can be repaired by inserting a filler aluminum flat bar. What’s the minimum thickness for
this flat bar?
a.) 2mm (3/32 in)
b.) 5mm (3/16 in)
c.) 6mm (1/4 in)
d.) 10mm (3/8 in)
What`s the maximum allowed side and front panel cut welding?
a.) Cuts up to a maximum of 75 mm (3 in) in length with a maximum width of 5 mm (3/16 in).
b.) Cuts up to a maximum of 50 mm (2 in) in length with a maximum width of 3 mm (1/8 in).
c.) Cuts up to a maximum of 50 mm (2 in) in length with a maximum width of 5 mm (3/16).
d.) Cuts up to a maximum of 75 mm (3 in) in length with a maximum width of 3 mm (1/8 in).
What are the Limitation of Full-profile vertical welds (exclude the weld connections between rail
and corner fittings) in a rail.
a.) Limited to 3 full profiles welds on a 20ft and 4 on a 40’ container
b.) Unlimited full profiles welds on a 20ft and 40’ container
c.) Limited to 2 full profiles welds on a 20ft and 4 on a 40’ container
d.) Limited to 0 full profiles welds on a 20ft and 2 on a 40’ container
To avoid galvanic corrosion between dissimilar metals (aluminum and steel), repairs must have.
a.) Paint
b.) Foam
c.) EP primer
d.) Insulation tape
What is the recommended repair method for a cut on interior scuff liner?
a.) Weld if cut is within 50mm long and 2mm wide
b.) Rivet Patch
c.) Welded insert
d.) Caulk with silicon
What is the recommended repair method for a 25mm diameter hole on T-floor base plate?
a.) Weld
b.) Patch
c.) Insert
d.) Caulk
Why condenser coil needs to be check & clean out during PTI?
a.) Improve air exchange.
b.) Prevent dirt & sea salt deposit
c.) Prevent premature wear and tear
d.) All of the above
Why defrost drain pan & drain tube need to be check during PTI?
a.) Enhance box appearance
b.) Prevent choking
c.) Prevent premature wear and tear
d.) None of the above
What is the repair method for a moisture indicator that is yellow in color?
a.) Replace Sight Glass
b.) Replace filter drier
c.) Evacuate and Replace Freon and Drier
d.) No Repairs Required
When repairing Sandwich-panel insulation, why the foam free rise density cannot be less than
50Kg/m³?
a.) To avoid reducing the tare weight of container
b.) To reduce the migration of heat
c.) To ensure proper adhesion of foam to panel
d.) None of the above
When the conflict happens between IICL’s criteria and owner’s criteria, which party’s criteria will
take precedence?
A) Customer
B) IICL
C) Owner
D) 3rd party surveyor
What is the minimum distance between inserts common joint weld on corner posts?
A) 50mm (2 in)
B) 100mm (4 in)
C) 150mm (6 in)
D) 200mm (8 in)
The IICL dent tolerance for front corner posts is ____________and for top side rails it
is___________ .
a. 25 mm (1 in)……...............35 mm (1-3/8 in).
b. 35 mm (1-3/16 in)…......... 20 mm (13/16 in).
c. 20 mm (13/16 in)…............35 mm (1-3/8 in).
d. 30 mm (1-3/16)…............. 30 mm (1-3/16).
“T” section aluminum floor flanges have gouged to the vertical web. In which case would this
condition be required repair?
Select one:
A. If in excess of 300mm (12 in).
B. If in excess of 200mm (8 in).
C. If in excess of 150mm (6 in)..
D. If in excess of 100mm (4 in).
Choose the correct list of the following components: 1, 2, 5, 6 and 7.
A. Filter drier, Condenser coil, Evaporator coil, Receiver tank, Sight glass
B.Quench Valve , Evaporator coil, Condenser coil, Receiver tank, Suction modulation valve
C. Filter drier, Evaporator coil, Condenser coil, Compressor, Sight glass
D. Suction modulation valve, Evaporator coil, Condenser coil, Compressor, Sight glass
Select one:
A. 1) Reduce noise and vibration to cargo space.
2) 25 mm - (1 in).
B. 1) Direct the airflow to the ceiling.
2) 20 mm - (13/16 in).
C. 1) Direct the airflow to the "T" floor.
2) 25 mm - (1 in).
D. 1) Direct the airflow to the machinery.
2) 25 mm - (1 in).
True or False ?
1) Proper repair should restore the original size and profile of the repaired component.
2) In order to repair damage properly and completely, adjacent components, which are damaged but not beyond
listed criteria, may also have to be repaired.
3) Repair is required if the damage is greater than the IICL tolerances.
a. All false.
b. 2 is false.
c. 1 and 3 are true.
d. All true.
1) When patching panels using rivets, what type of sealant should be used between the rivet line and edge?
2) What should be the distance between rivets?
3) What should be the distance between the rivets and the edge of the patch?
a.
1) Acrylic sealant.
2) 25 mm - (1 in).
3) 13 mm - (1/2 in).
b.
1) Polyurethane sealant.
2) 25 mm - (1 in).
3) 13 mm - (1/2 in).
c.
1) Silicone sealant.
2) 25 mm - (1 in).
3) 6 mm - (1/4 in).
d.
1) Marine grade sealant.
2) 25 mm - (1 in).
3) 13 mm - (1/2 in).
Scuff lining pulled from its original connection should be repaired and internal adhesion to the foam restored by
injecting_______________________.
…cyanoacrylate glue.
…contact glue.
…urethane glue.
…acrylic resin.
A.
1) 150 mm - (6 in).
2) 300 mm - (12 in).
3) 150 mm - (6 in).
B.
1) 150 mm - (6 in).
2) 150 mm - (6 in).
3) 150 mm - (6 in).
C.
1) 300 mm - (12 in).
2) 300 mm - (12 in).
3) 150 mm - (6 in).
D.
1) 300 mm - (12 in).
2) 150 mm - (6 in).
3) 150 mm - (6 in).
A.
1) 150 mm - (6 in).
2) 300 mm - (12 in).
3) 150 mm - (6 in).
Proper inspection is paramount for the proper operation of the equipment. There are many parts and
components to be inspected on a refrigerated container.