Professional Documents
Culture Documents
Introduction
Jersey Linear Flow Bar is an architecturally designed
high capacity linear diffuser. It is designed to combine a
high air handling capacity with maximum flexibility and is
suitable for either ceiling or sidewall applications. The
flexibility of the system can blend into a design or
provide contrast with its striking but simple design. The
Flow Bar system satisfies the requirements for
designing an air distribution system, whilst becoming
an integral component of the architectural concept of
the project.
Application
• Linear diffuser system with engineered
• Desirable large capacity, single slot appearance
• Versatile pattern control for installation in low or high
sidewalls and ceilings
• Adjustable for horizontal or vertically projected air Pattern Control Flexibility
discharge patterns.
Horizontal Left
• Excellent for VAV applications
• Drywall / hard surface and suspended ceiling
applications
• Configured to your specification - Curvatures
• Mitered corners for ceiling and wall mounts.
Product Features
• Construction from heavy extruded aluminum 6063-T5
• 3m lengths available to minimize joints
• 25mm, 38mm, 50mm slot widths Horizontal Right
• 1 slot or 2 slots
• Field adjustable pattern controllers for horizontal left or
right, or vertical projection air discharge patterns
• Controllers are cut to nominal 600mm (allows for
alternating pattern
• changes within the run from left or right horizontal, to
vertical)
• Powder Coated to RAL 9010 finish
• Pattern Controllers are black.
• Center T’s on multiple slot units are RAL9010 Vertical
Flange Types
Type “S” - Standard Type “X” - Flangeless Product Selection Check List
(Surface mounting) • Select unit Length based on performance
• Review Architectural requirements
• Select slot width and number of slots required
• Select Type of Frame required
• Select End Connection requirements
• Select Accessories
• Select RAL colour required
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.
D=DUCT OPENING
DIMENSIONS
DUCT
(BY OTHERS)
Model FFS (Supply) – with Pattern Control
Model FFS-R (Return) – Pattern control excluded
F
DAMPER Model FFS Pattern Control
(ONLY FOR
SUPPLY) Model FFS-R Control excluded
43
1 122 99 101 95 38 42 -
F
DAMPER
(ONLY FOR
2 209 186 188 182 38 42 49
SUPPLY)
43
1 69 73 69 69 25 35 -
F
Model FFX-50 (50mm slot width)
DAMPER
(ONLY FOR # of SLOTS C D E F G H J
SUPPLY)
1 121 125 121 121 51 48 -
43
J G H
E=CEILING OPENING CEILING LINE
C
L L
43
43
28
L+56 1.5
L3+
'L' : LENGTH OF FFS FRAME
'L' : LENGTH OF FFX FRAME
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.
Model FFS-25 (25mm Slot Width) Model FFS-25 (25mm Slot Width)
# of SLOTS F L A # of SLOTS F L A
Model FFS-38 (38mm Slot Width) Model FFS-38 (38mm Slot Width)
# of SLOTS F L A # of SLOTS F L A
Model FFS-50 (50mm slot width) Model FFS-50 (50mm Slot Width)
Custom Formed Radius
# of SLOTS F L A # of SLOTS F L A
ACCESSORIES
Model FFS-25 (25mm Slot Width) Model FFS-25 (25mm Slot Width)
# of SLOTS F L A # of SLOTS F L A
Blank Off Plates
1 95 193 150 1 70 193 150
Model FFS-38 (38mm Slot Width) Model FFS-38 (38mm Slot Width)
# of SLOTS F L A # of SLOTS F L A
Model FFS-50 (50mm slot width) Model FFS-50 (50mm Slot Width)
# of SLOTS F L A # of SLOTS F L A
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.
Performance Data
# CMH/M/
110 138 166 221 277 332 388 443 498 554
SLOTS SLOT
CMH 110 138 166 221 277 332 388 443 498 554
Ps 5.0 7.0 11.0 17.0 28.0 35.0 53.0 75.0 104.0 116.0
1
NC <15 <15 <15 19 22 28 32 35 38 41
Throw 1 2 4 2 2 4 2 3 5 3 4 6 3 4 7 4 5 8 4 6 8 5 6 8 5 7 9 6 7 10
CMH 220 276 332 442 554 664 776 886 996 1108
Ps 5.0 7.0 11.0 17.0 28.0 35.0 55.0 77.0 110.0 124.0
2
NC <15 <15 <15 20 24 30 34 37 40 44
Throw 2 3 5 2 3 6 3 4 7 4 5 8 4 6 10 5 7 10 6 8 11 6 8 12 7 9 13 8 10 13
# CMH/M/
166 221 277 332 388 443 498 554 609 665
SLOTS SLOT
CMH 166 221 277 332 388 443 498 554 609 665
Ps 9.0 14.0 20.0 25.0 33.0 42.0 55.0 77.0 97.0 121.0
1
NC <15 <15 <15 20 24 27 31 33 37 40
Throw 2 3 5 3 4 6 3 4 7 4 5 7 4 6 8 5 6 8 5 6 9 6 7 9 6 7 10 6 7 10
CMH 332 442 554 664 776 886 996 1108 1218 1330
Ps 9.0 14.0 20.0 28.0 33.0 42.0 61.0 77.0 99.0 124.0
2
NC <15 <15 16 22 27 31 35 38 41 44
Throw 3 4 7 4 5 8 4 6 9 5 7 10 6 8 11 7 8 11 7 9 12 8 9 13 8 10 13 8 10 14
# CMH/M/
332 388 443 498 554 609 665 720 776 831
SLOTS SLOT
CMH 332 388 443 498 554 609 665 720 776 831
Ps 9.0 14.0 20.0 25.0 35.0 42.0 55.0 77.0 94.0 124.0
1
NC <15 19 23 26 31 33 35 37 39 41
Throw 3 5 8 4 5 8 4 6 8 5 7 9 5 7 10 6 7 10 6 8 10 6 8 11 7 8 11 7 8 11
CMH 664 776 886 996 1108 1218 1330 1440 1552 1662
Ps 9.0 14.0 20.0 25.0 35.0 42.0 55.0 77.0 94.0 124.0
2
NC 19 22 28 31 34 36 38 40 42 44
Throw 4 7 10 5 8 11 6 8 12 7 9 13 7 10 13 8 10 14 8 10 15 9 11 15 9 11 15 10 11 16
Test Standard
ANSI / ASHRAE standard 70 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
Data is based on 1200mm active length. For other active lengths, use the following adjustment factors
Adjust NC value by -3 0 +2 +3 +4
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.
Performance Data
# CMH/M/
139 167 195 222 278 333 389 444 499 555
SLOTS SLOT
CMH 139 167 195 222 278 333 389 444 499 555
Ps 3 7 10 11 14 20 28 35 42 55
1
NC <15 <15 <15 18 22 24 25 28 30 32
Throw 1 2 4 2 2 4 2 3 5 2 3 5 3 4 6 3 4 7 3 5 7 4 5 8 4 6 8 5 6 8
CMH 278 334 390 444 556 666 778 888 998 1110
Ps 3 7 10 11 14 20 28 35 42 55
2
NC <15 <15 <15 20 23 24 25 28 31 33
Throw 2 3 5 2 3 6 3 4 7 3 4 8 4 5 8 4 6 9 4 7 10 5 8 11 6 8 11 6 8 12
# CMH/M/
167 222 278 333 389 444 499 555 610 666
SLOTS SLOT
CMH 167 222 278 333 389 444 499 555 610 666
Ps 6 9 11 14 20 25 28 33 39 44
1
NC <15 <15 <15 19 22 24 26 29 32 34
Throw 1 2 4 2 2 4 2 3 5 2 4 6 3 4 7 3 4 7 4 5 7 4 5 8 4 6 8 4 6 8
CMH 334 444 556 666 778 888 998 1110 1220 1332
Ps 6 9 11 14 20 25 28 33 39 44
2
NC <15 <15 18 21 23 24 28 29 32 35
Throw 2 3 5 2 3 6 3 4 8 3 5 8 4 5 9 4 6 10 5 7 10 5 8 11 6 8 11 6 8 12
# CMH/M/
389 444 499 555 610 666 721 777 832 887
SLOTS SLOT
CMH 389 444 499 555 610 666 721 777 832 887
Ps 6 9 11 14 20 25 28 33 39 44
1
NC <15 <15 17 19 21 22 24 25 27 31
Throw 2 3 6 3 4 7 3 4 8 3 5 8 4 5 8 4 5 9 4 6 9 4 6 9 5 7 10 5 7 10
CMH 778 888 998 1110 1220 1332 1442 1554 1664 1774
Ps 6 9 11 14 20 25 28 33 39 44
2
NC <15 <15 18 20 21 23 24 26 28 31
Throw 3 4 9 4 5 10 4 6 11 4 6 11 5 7 11 5 8 12 6 8 13 6 9 13 6 9 14 7 10 14
Test Standard
ANSI / ASHRAE standard 70 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
Data is based on 1200mm active length. For other active lengths, use the following adjustment factors
Adjust NC value by -3 0 +2 +3 +4
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.
FFR-25 (25mm Slot Width) FFR-38 (38mm Slot Width) FFR-50 (50mm Slot Width)
1 Slot 2 Slot 1 Slot 2 Slot 1 Slot 2 Slot
CMH/M CMH/M CMH/M
Ps NC Ps NC Ps NC Ps NC Ps NC Ps NC
Test Standard
ANSI / ASHRAE standard 70 “Method of Testing for Rating the Performance of Air Outlets and Inlets”
Data based on non-ducted, pressurized ceiling plenum applications. Ducted plenums should be sized with inlet velocities less than 750 fpm while maintaining equal
discharge velocities along the diffuser length to maintain catalogue data.
Sound Levels
NC is noise criteria curve that will not be exceeded at the operating point. This is determined by assuming a 10dB (ref: 10-12 watts) room attenuation that is subtracted
from the power levels in each of the 2nd thru 7th octave bands
NC shown is based on 1200mm diffuser length. For other active lengths, use the following adjustment factors:
Adjust NC value by -3 0 +2 +3 +4
For installation with a free, unattached jet, multiply throw value by 0.70. For two way applications, determine proportion of air in each direction and refer to throw distance
for number of slots in the same direction.
Terminal velocity is the air speed, in meters per second, measured in the supply air stream
Pressure
Ps represents Static Pressure, Pa
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.
*In the interest of product development, Jersey Manufacturing reserves the right to make changes without notice.