You are on page 1of 16

Humanity’ s Vision Is Our Focus

The Ahmed Glaucoma Valve


®
New World Medical is a high tech The R&D division of New World Medical
medical device company whose is actively involved in developing
goal is to help humanity lead a better new products through collaborations
life through improved technology with number of renowned medical
and innovation. Presently New World universities and ophthalmologists
Medical focus is in different areas of around the world. These partnerships
Ophthalmology. allow New World Medical to develop
products through a first-hand
The Ahmed Glaucoma Valve has involvement in the medical device
been successfully demonstrated to industry.
work in all types of glaucoma cases,
particularly Neovascular, Congenital, Dr. A. Mateen Ahmed founded
and Uveitic glaucoma. New World New World Medical, and serves as
Medical manufactures and markets its President and Chairman of the Board
own products. In the U.S., New World of Directors. The vision of Dr. Ahmed
Medical markets its products through and New World Medical is to help
a team of sales representatives. In the the lives of people around the world.
international market, the company has This has earned the company many
exclusive distribution network around accolades, including the “Have a
the globe selling all over the world. Heart, International Goodwill, and
Along with its own products, New Understanding Award” given by
Dr. A. Mateen Ahmed World Medical also distribute human Soroptimist International.
President - New World Medical tissue such as sclera and pericardium.
Mechanics of the
Ahmed Glaucoma Valve
The Venturi Effect:
To reduce internal friction within the valve system, the Ahmed
Glaucoma Valve utilizes a specially designed, tapered
trapezoidal chamber to create a Venturi effect to help aqueous
flow through the device. The inlet velocity of aqueous entering
the larger port of the venturi chamber increases significantly as it
exits the smaller outlet port of the tapered chamber. In an Ahmed
Glaucoma Valve, this increased exit velocity greatly helps in
evacuating aqueous from the valve, thereby helping to reduce
valve friction.

Non-Obstructive, Self-Regulating Valve Mechanism:


The Ahmed Glaucoma Valve has no obstruction in its path of
fluid flow. For the flow to be non-obstructive, a particle large
enough to pass through the lumen of the tube, will easily
pass through the much larger opening of the Venturi-Flow™
chamber. The elastic membranes help to regulate fluid flow at
all times, consistently by changing their shape. The tension on
these membranes is responsible of reducing hypotony.

VenturiFlo™
Model FP7
Ahmed Glaucoma Valve
Flexible Plate
Features: Plate/Valve Materials:
+ Made of medical grade silicone Specifications: Valved Plate Body: medical-grade silicone
+ Immediate reduction of intraocular pressure Thickness: 2.1mm Drainage Tube: medical-grade silicone
+ Unique, non-obstructive valve system to prevent Width: 13.0mm Valve: medical-grade silicone, elastomer
excessive drainage and chamber collapse Length: 16.0mm membrane
+ Implanted in a single-stage procedure Surface Area: 184.0mm2 Valve Casing: medical-grade
polypropylene
+ Tapered profile for easy insertion
+ Silicone plate Tube Specifications:
+ Aqueous percolation holes Ordering Information:
Length: 25.4mm
+ Thinner Plate Model: FP7
Inner Diameter: 0.305mm (Ahmed Flexible Plate)
Outer Diameter: 0.635mm

Model FP7
Model FP8
Ahmed Glaucoma Valve
Flexible Plate
Features: Plate/Valve Materials:
+ Made of medical grade silicone Specifications: Valved Plate Body: medical-grade silicone
+ Used for pediatrics or small globes Width: 11.0mm Drainage Tube: medical-grade silicone
+ Immediate reduction of intraocular pressure Length: 11.0mm Valve: medical-grade silicone, elastomer
Surface Area: 102.0mm 2 membrane
+ Unique, non-obstructive valve system to
prevent excessive drainage and chamber Thickness: 2.1mm Valve Casing: medical-grade
collapse polypropylene
+ Implanted in a single-stage procedure
Tube Specifications:
+ Eliminates drainage tube ligature sutures, Ordering Information:
“rip-chord” sutures, and occluding sutures Length: 25.4mm
Model: FP8
+ Thinner Plate Inner Diameter: 0.305mm (Ahmed Flexible Plate)
Outer Diameter: 0.635mm

Model FP8
Model S2
Ahmed Glaucoma Valve
Features: Plate/Valve Materials:
+ Immediate reduction of intraocular Specifications: Valved Plate Body: medical-grade
pressure Thickness: 1.6mm polypropylene
+ Unique, non-obstructive valve system Width: 13.0mm Drainage Tube: medical-grade silicone
to prevent excessive drainage and
Length: 16.0mm Valve: medical-grade silicone, elastomer
chamber collapse membrane
+ Implanted in a single-stage procedure Surface Area: 184.0mm2

+ Eliminates drainage tube ligature sutures,


Ordering Information:
“rip-chord” sutures, and occluding Tube Specifications:
sutures Model: S2
Length: 25.4mm (Ahmed Glaucoma Valve)
Inner Diameter: 0.305mm
Outer Diameter: 0.635mm

Model S2
Human
Allograft Tissue
Pericardium and Sclera
Features: Ordering Information:
+ Biocompatible human tissue for leaking blebs TSH: (Human Sclera)
+ Gamma sterilized
TPH: (Hydrated Pericardium)
+ 2.5 years shelf life
TPD: (Freeze-Dried Pericardium)
+ Nominal thickness 0.5mm
+ Available Freeze-Dried or Hydrated
+ Available full thickness sclera or pericardium
+ Can be used as ocular tissue for other
cosmetic uses

Human Allograft
Model TE
Tube Extender™
Tube Extender Features: Ordering Information:
+ Provides extra tube length Model: TE (Tube Extender)
+ Provides leak-proof junction between tubes
+ Helpful when drainage tube is cut too short
+ Can be used with other drainage devices
+ Easily sutured onto sclera
Model TI
Tube Inserter™
Features: Ordering Information:
+ Notched tip secures valve tube Model: TI (Tube Inserter)
+ Provides rigidity to valve tube for easy
insertion into the anterior chamber
+ Stainless steel
+ Serrated grip
+ Shorter tip helps to provide better view
through microscope
+ Reusable and inexpensive
+ Can be used with any drainage device

Accessories
Surgical Procedure
1. 2. 3. 4. 5.

The implant should be A fornix-based incision The valve body is inserted The drainage tube is A paracentesis is performed,
examined and primed prior is made through the into the pocket between trimmed to permit a and the AC is entered at 1-2
to implantation. Priming is conjunctiva and Tenon’s the rectus muscles and 2-3 mm insertion of the mm away from the limbus with
accomplished by injecting capsule. A pocket is sutured to the episclera. tube into the anterior a sharp 23 gauge needle to
1cc balanced salt solution formed at the superior The leading edge of the chamber (AC). The tube create a needle track, parallel
or sterile water through the quadrant between the plate should be at least should be bevel cut to to the iris.
drainage tube and valve, medial or lateral rectus 8-10mm from the limbus. an anterior angle of 30°
Caution: Care must be taken
using a blunt 26 gauge muscles by blunt dissection to facilitate insertion.
to ensure that the drainage
cannula. of Tenon’s capsule from
tube does not contact the iris
the episclera.
or corneal endothelium after
insertion.
6. 7.
Note: Some surgeons prefer
to enter the AC from at least
3mm away from the limbus.

The steps illustrated here are intended as a guideline


only, and do not represent recommended treatment for
any particular patient. The use of any specific surgical
The drainage tube is The exposed drainage tube NOTE: As an alternative technique or maneuver is at the sole discretion of
inserted approximately 2-3 is covered with a piece of to Step 7, a 2/3 thickness the surgeon. Surgeons should be familiar with the use
mm into the AC through preserved, donor sclera, limbal-based scleral flap of glaucoma drainage devices and post-operative
the needle track created pericardium, cornea, may be made. The tube is care considerations before implanting any drainage
in step 5. or other suitable patch inserted into the AC through device. Reference papers and surgical video tapes are
graft material which is a 23 gauge needle puncture available upon request.
sutured into place and the made under the flap. The
conjunctiva is closed. flap is sutured closed.
Patents No. 5, 071, 408 Patents No. 6, 261, 256 Caution: (U.S.) Federal Law restricts
Patents No. 5, 411, 473 Patents No. 5, 681, 275 these devices to sale by or on the
Patents No. 5, 785, 674 Patents No. 5, 616, 118 order of a physician.
www.newworldmedical.com

+1.909.466.4304
H u m a nit y’ s V is io n I s O u r F o c u s
10763 Edison Court
Rancho Cucamonga, CA 91730

Customer Service in USA


800.832.5327

Part # 50-0038 Rev E 02/18