8/10/2017 10:36:28 H&N - production Sifter problem in H&N - production kishore 8/10/2017 10:36:00 Completed Lokesh karthik/Murugan
Upstream
Documentation Karthick/Murugn/Veere
8/12/2017 7:38:11 Room Door lock came out to be fixed vinod kumar 8/12/2017 7:37:00 Completed Bhogesh/Irshad sh
QC INSTRUMENT AC is not working properly(room
9/5/2017 14:56:28 AREA temperature is not maintained) Bala 9/5/2017 14:54:00 Completed Bhogesh/Irshad Dinesh/Irshad
BPM downstream
wash area door
glass broken from During fumigation process door
one side. Pls glass was broken (while opening the
9/18/2017 0:43:30 change the glass. door) Anandh 9/17/2017 23:55:00 Completed Bhogesh/Irshad Dinesh/Bhogesh
centrifuge AOD BPM centrifugation area , centrifuge
pump not working AOD pump not working please
at upstream area, rectify the problem and hand over
9/25/2017 21:50:32 pls rectify ASAP. Anandh 9/25/2017 21:48:00 Completed Dinesh Bhogesh/Rajesh closed
QC Chemical
10/6/2017 11:51:08 Refrigerator Freezer door to be replaced Fameeda 10/6/2017 11:50:00 Completed irshad
BPM Downstream- Quatro flow diaphragm pump - VFD
Ultrafiltration frequency adjusting switch is not
11/16/2017 16:56:27 system functioning properly. Suresh.C 11/16/2017 16:56:00 Completed karthik closed
QC
INSTRUMENTATI AC is not working properly(room
11/17/2017 12:56:36 ON AREA temperature is not maintained) AHAMAD 11/17/2017 12:55:00 completed Chakra
BPM production 214 extension
11/20/2017 9:12:03 214 Extension cordless charger is not working. k.vinod kumar 11/20/2017 9:12:00 completed Karthik
AC in QC-Chemical
Instrumentation
11/20/2017 22:30:54 area AC IS NOT WORKING AHAMAD 11/20/2017 22:30:00 completed Chakra
Steam Condensate
leakage from
insulation in Steam Condensate leakage from
11/21/2017 11:19:58 Centrifuge area. insulation in Centrifuge area. vinod kumar 11/21/2017 11:19:00 Completed Dinesh
Microbiology lab temperature is not
maintaining, which is supposed to be
19-23 degree C. Presently it is
12/4/2017 9:36:15 Microbiology lab maintaining 26 degree C. Mubeen 12/4/2017 9:30:00 Rectified Dinesh
Door has not been get closed fully
Change Room-I itself since yesterday due to door
12/4/2017 14:47:18 Door closure issue Sathish Kumar 12/4/2017 14:50:00 Rectified Pramod
Column packing - AOD pump FRL dameged so that is
AO Diaphragm removed. New FRL to be fixed for
12/14/2017 6:28:12 pump the pump. S.Nagoor 12/14/2017 6:27:00 New FRL provided chakra
chromatography air sensor false alarm observed
12/30/2017 23:02:09 system continuously. need to be check sivanesh 12/31/2017 23:00:00 Rectified karthik
Near Ultra Filtration system Chilled
1/1/2018 7:22:53 Downstream water supply SS hose is leaking. S.Nagoor 1/1/2018 7:22:00 Rectified Dinesh
QC-INSTRUMENT
1/7/2018 0:05:17 AREA ceiling light not working arun 1/7/2018 0:04:00 New lamp fixed Chakra rajesh/pramod
1/8/2018 10:06:30 Mobile tank 05 Mobile tank -05 sample port leakage vinod kumar 1/8/2018 10:05:00 Rectified Chakra
Name of the
Breakdown person raising the Contact person from Severity of the
Timestamp equipment/Area Give brief details of the issue request Date of reporting Current status of the issue Engineering problem Closed by Remarks
Mobile tank -02 Mobile tank-02 Jacket pinhole
1/8/2018 10:07:48 Downstream leakage vinod kumar 1/8/2018 10:05:00 Rectified Chakra
Near Chromatography system Chill
Downstream Area water outlet valve damaged to be
1/8/2018 10:09:12 Chill water line changed. vinod kumar 1/8/2018 10:05:00 Rectified Dinesh Dinesh
DOWNSTREAM /
1/10/2018 3:26:58 HLV 01 Vessel lamp is not working RAJENDIRAN 10/1/2018 3:26:00 emergency push button pressed now released. Chakra karthik
The incubation area room
temperature is going out of limit
(above 27 degrees) when the
shaker incubator is in running
Microbiology condition.The room temperature
1/10/2018 19:49:14 lab/Incubation area suppose to be 22 degrees(+-3). Mubeen 1/10/2018 19:45:00 Temp set point changed . temp is maintaining Chakra Chakra
Chromatography Chromatography System Air sensor
1/12/2018 14:24:50 System showing False alarm vinod kumar 1/12/2018 14:24:00 Working fine after calibration Chakra
CIP Tank Alkali In CIP tank Alkali Dosing pump is not
1/17/2018 1:45:27 dosing pump working. vinod kumar 1/17/2018 1:44:00 Rectified Dinesh Dinesh
QC- Chemical
Media disposal
1/21/2018 13:43:36 area Water tap is not closing properly arun 1/21/2018 13:43:00 Rectified chakra Irshad/Dinesh
QC-Chemical washbasin sink is not flushing
Chemical analysis properly, water logging inside
1/21/2018 13:53:23 area cupboard if its operated arun 1/21/2018 13:53:00 Rectified chakra
BDI 2 incubator ie
(22.5 degrees) in The incubator is not getting switched
1/22/2018 16:41:34 incubator room on. Amar 1/22/2018 16:30:00 Rectified Rajesh Rajesh
Shaker incubator 2
(BPM/MB/SHR/02) The shaker incubator is not
1/23/2018 14:44:36 in Cooling zone maintaining the set temperature Amar 1/23/2018 14:44:00 Found no issues , running trial taken ok . Rajesh Rajesh
Instrument panel - Instrument air
Upstream - leakages from the terminals are
1/25/2018 11:53:52 Instrument panel there in the panel. To be arrested. Suresh.C 1/25/2018 11:53:00 Arrested karthik
Electric cables for refrigerators
running on the floor with a junction
1/30/2018 15:43:41 BPM- FG area box. To be concealed over the walls. Suresh.C 1/30/2018 15:43:00 Completed Chakra
100MM glass
column 100mm galss column in downstream
2/3/2018 15:07:36 there is a leakage in oring. vinod kumar.k 2/3/2018 15:07:00 Rectfied Dinesh high Dinesh
upstream
fermentation area upstream fermentation area old 5kl
old 5kl valve no valve no APVV 302 physically
APVV 302 opened condition but in system
physically opened valves has been closed need to be
condition. All jacket rectified. All jacket utility lines
utility lines actuated actuated valves poly urothin tubes
valves poly urothin are become expired need to replace
tubes are become with new one (its breaking
2/16/2018 16:31:19 expired. automatically). jastikrishna 2/16/2018 16:25:00 Rectified Bogesh/karthik Dinesh
PESTOP UV light PESTOP which is above QC
3/7/2018 8:23:47 not working instrument area door, is not working arun 3/7/2018 8:20:00 Completed Pramod pramod
Temperature sensor painting peeled
3/10/2018 13:38:09 Mobile Vessel's off & sample valve leakage observed Vinu 3/10/2018 13:38:00 Completed Murugan /Veeresh Murugan/veeresh
MG-BPM -06 to MG-BPM-10 all Area
monitoring magnahelic guages
pressure is out of range need to be
3/11/2018 0:01:26 Downstream rectify ASAP. vinod kumar.k 3/11/2018 0:01:00 Rectified Dinesh Dinesh
Gents Toilet- BPM wash basin tap (left side) water
3/26/2018 22:32:06 Facility leaking. S.Nagoor 3/3/2018 22:30:00 Rectified Pramod
BPM/PD/HRV/02 -
3/27/2018 0:43:18 Harvest Vessel-02 Vessel lamp not glowing. S.Nagoor 3/3/2018 0:42:00 Rectified Rajesh Rajesh
Vessel jacket Drain valve (manual
BPM/PD/HRV/02 - pall valve) passing observed in
3/27/2018 0:51:39 Harvest vessel-02 closed condition. S.Nagoor 3/3/2018 0:50:00 Rectified Dinesh
Two Dosing pumps(Alkali & Acid)
were in removed condition, Need to
3/27/2018 0:58:26 CIP Tank be connect in working condition. S.Nagoor 3/27/2018 0:57:00 New AODD pump fixed Dinesh Dinesh
Downstream
3/27/2018 1:18:31 corrider One of ceiling lamp is not glowing. S.Nagoor 3/27/2018 1:10:00 Rectified Rajesh/pramod Rajesh/pramod
CIP preparation
3/27/2018 1:20:37 area One of ceiling lamp is not glowing. S.Nagoor 3/27/2018 1:20:00 Rectified Rajesh/pramod Rajesh/pramod
3/27/2018 1:21:55 Production Corridor One of ceiling lamp is not glowing. S.Nagoor 3/27/2018 1:21:00 Rectified Rajesh/pramod Rajesh/pramod
3/28/2018 1:07:13 CIP Tank Vessel lamp is not glowing. S.Nagoor 3/28/2018 1:06:00 fixed
QC-CHEMICAL Room-temperature in instrument
(instrument area), area is not maintained. QC chemical
3/30/2018 14:16:10 AC and intercom intercom is not working, line is dead. arun 3/30/2018 14:16:00 New exhaust fan fixed chakra chakra
Microbiology lab
temperature is not maintaining the
limit. The current
temperature is 28 degrees in all
rooms which suppose to be
3/30/2018 15:11:24 Microbiology Lab 22 degrees(+/- 3 ). Mubeen 3/30/2018 15:05:00 Rectified chakra chakra
Downstream
lyophilizer room Temperature and humidity out of
4/3/2018 15:30:13 and packing room. range. vinod kumar 4/3/2018 15:30:00 New Dx unit fixed , temp and Humidity in range chakra Chakra/Irshad
1.Inside Downstream area corridor
entrance light is not glowing.
2.Downstream washing area light is
4/3/2018 15:32:34 Downstream Area not glowing vinod kumar 4/3/2018 15:31:00 new lights fixed lokesh lokesh
DOWNSTREAM DOWNSTREAM inside corridor
4/9/2018 9:57:13 inside corridor. lights are not glowing. vinod kumar 4/9/2018 9:57:00 new lights fixed Murugan/lokesh Murugan/lokesh
The slide stage knob is not working
Microscope in properly as the band connecting is Sliding belt damage to be repleced with new , order to
4/13/2018 11:58:29 cooling zone. worn out and needs to be replaced. Amar 4/13/2018 11:57:00 be placed chakra
4/30/2018 9:19:24 Qc Chemical Area AC is not working Sarathkumar.m 4/30/2018 9:20:00 Rectified chakra Chakra
new refrigerator
5/22/2018 13:57:29 BPM/PD/RFG/03 refrigerator key got broken sivanesh 5/22/2018 2:50:00 New lock to be procured
Crevices and dents observed on
Packing area door.painting to be
5/29/2018 9:23:03 packing area done sivanesh 5/29/2018 9:22:00 Rectified Team Team
Rust to be removed on
Instrumentation lines present in
Packing area and Column packing
5/29/2018 9:25:00 packing area area sivanesh 5/29/2018 9:25:00 Rectified Team Team
Gap observed between light fixtures
5/29/2018 9:26:56 BPM and ceiling roof in BPM area sivanesh 5/29/2018 9:26:00 Rectified Team Team
All mobile vessels wheels are rusted
so badly need to paint or change the
5/29/2018 9:35:52 Downstream area same. manikandan 5/29/2018 9:35:00 Rectified Team Team
All electrical panels of mobile
5/29/2018 9:37:15 Downstream area vessels are rusted. manikandan 5/29/2018 9:36:00 Rectified Team Team
Rust observed on all doors in clean
5/29/2018 9:38:08 Downstream area room. Painting to be done. manikandan 5/29/2018 9:37:00 Rectified Team Team
Downstream filling Light fixture on top of the Lyophilizer
5/29/2018 9:39:08 area to be cleaned. manikandan 5/29/2018 9:38:00 Rectified Team Team
Downstram filling Wall cracks observed near view
5/29/2018 9:40:17 area panel of Lyophilizer area. manikandan 5/29/2018 9:39:00 Rectified Team Team
No calibration label and Instrument
Downstream ID on weighing balance
5/29/2018 9:42:03 weighing balance (BPM/PD/WGB/02) manikandan 5/29/2018 9:41:00 Rectified Team Team
Downstram filling Oil leakage & dust accumulation
5/29/2018 9:43:21 area observed backside of the Lyophilizer manikandan 5/29/2018 9:42:00 Rectified Team Team
Tool box to be placed in downstream
area, Found scattered tools
5/29/2018 9:44:14 Downstream area everywhere in area. manikandan 5/29/2018 9:43:00 Rectified Team Team
continous
6/8/2018 8:45:02 centrifuge CFG lamp is not glowing S.Nagoor 6/8/2018 8:45:00 New lamp fixed Team Team
Chromotography chrome system pump 2 is
6/8/2018 8:48:03 System malfunctioning. S.Nagoor 6/8/2018 8:46:00 Rectified Team Team
QC- Chemical,
6/12/2018 18:15:13 Spinwin Spin is Not working arun 6/12/2018 18:15:00 Rectified tempararely - new ordered chakra chakra
chromatography outlet ph and conductivity showing
6/13/2018 10:35:18 system out of range sivanesh 6/13/2018 10:35:00 Calibrated both,working fine Karthik Karthik
Name of the
Breakdown person raising the Contact person from Severity of the
Timestamp equipment/Area Give brief details of the issue request Date of reporting Current status of the issue Engineering problem Closed by Remarks
[DYNA] 250 liter
-01 batch report not
generating , pls In scada system Exell report not
6/25/2018 10:41:21 rectify generating, pls rectify ASAP. ANANDH 6/25/2018 10:41:00 Awaiting Clearance Karthik
Temperature of microbiology lab is
more than 28 degrees C. It is
Microbiology lab supposed to be 22 +/- 3 degree C.
6/25/2018 13:50:23 temperature Amar Anand 6/25/2018 13:45:00 Rectified Chakra/Irshad Chakra/Irshad
WATER FLOW
6/27/2018 3:11:55 METER Without any flow its showing values. SUDHARSAN.P 6/27/2018 3:12:00 Found no issues Karhik Karhik
BOD Incubator-
BPM/MB/BDI/01 /
Incubation area Set temperature 32.5 is not
6/27/2018 10:35:48 Microbiology maintaining. Divya 6/27/2018 10:35:00 Rectified Karhik Karhik
Media vessels In fermentation area media vessels
lamp not working lamp not glowing pls rectify before
pls rectify next batch.