You are on page 1of 1

midas Gen RC Column Checking Result

Company Project Title


Author Kevin File Name D:\...\Proyecto JHuamani.mgb
1. Design Condition z
Design Code : ACI318-05 UNIT SYSTEM : tonf, m
Member Number: 643 (PM), 641, 643 (Shear-y,z)
Material Data : fc = 2109.21, fy = 42184.2, fys = 42184.2 tonf/m^2
Column Height : 2.5 m
Section Property: C25X25 (No : 2)

0.25
Rebar Pattern : 6 - 2 - #4 Ast = 0.000774192 m^2 (Rhost = 0.012) y

0.0635
2. Axial and Moments Capacity
Load Combination : 5 (Pos : J)
Concentric Max. Axial Load PhiPn-max = 74.5277 tonf 0.25
Axial Load Ratio Pu / PhiPn = 4.77846 / 16.0465 = 0.298 < 1.000 ....... O.K
Moment Ratio Mc / PhiMn = 0.90668 / 3.06518 = 0.296 < 1.000 ....... O.K
Mcy / PhiMny = 0.90015 / 3.04291 = 0.296 < 1.000 ....... O.K
Mcz / PhiMnz = 0.10866 / 0.36883 = 0.295 < 1.000 ....... O.K

P-M Interaction Diagram


P(tonf)
147
PhiPn(tonf) PhiMn(tonf-m)
129 Theta=6.91Deg.
N.A=10.13Deg. 93.16 0.00
111 81.52 1.11
93 67.35 2.16
53.51 2.72
75 75
40.41 2.95
57 28.83 2.99
39 21.63 2.97
20
18.69 3.06
(16,3) 13.63 3.04
0
2
(5,1) 4.62 2.83
-16
M(tonf-m) -12.92 1.63
-34 -26.23 0.44
-29.39 0.00
0

3. Shear Capacity
[ END ] y (LCB : 10, POS : J) z (LCB : 4, POS : J)
Applied Shear Force (Vu) 0.06018 tonf 0.64290 tonf
Design Shear Strength (PhiVc+PhiVs)
2.89258 + 4.18745 = 7.08003 tonf 2.83941 + 4.18745 = 7.02686 tonf
Shear Ratio 0.009 < 1.000 ....... O.K 0.091 < 1.000 ....... O.K
As-H_use 0.00071 m^2/m, 2-#3 @200 0.00071 m^2/m, 2-#3 @200

[ MIDDLE ] y (LCB : 10, POS : 1/2) z (LCB : 4, POS : 1/2)


Applied Shear Force (Vu) 0.06018 tonf 0.64290 tonf
Design Shear Strength (PhiVc+PhiVs)
2.89776 + 4.18745 = 7.08521 tonf 2.84660 + 4.18745 = 7.03405 tonf
Shear Ratio 0.008 < 1.000 ....... O.K 0.091 < 1.000 ....... O.K
As-H_use 0.00071 m^2/m, 2-#3 @200 0.00071 m^2/m, 2-#3 @200

Modeling, Integrated Design & Analysis Software Print Date/Time : 08/06/2022 17:33