Professional Documents
Culture Documents
Quiz
Study Session 4
IRC Sections R311 through R323
2. Where the stairway has a straight run, a stairway landing shall have a minimum
depth of _______________ measured in the direction of travel.
a. 30 inches b. 32 inches
c. 36 inches d. 42 inches
R311.8.2
Reference __________
3. Unless technically infeasible due to site constraints, the maximum slope of a ramp
serving the required egress door shall be one unit vertical in _______________ units
horizontal.
a. five b. eight
c. ten d. twelve
R311.8.1, Exception
Reference __________
5. Where a ramp changes direction, the width of the landing perpendicular to the ramp
slope shall be a minimum of __________ inches.
a. 36 b. 42
c. 48 d. 60
R311.8.2
Reference __________
6. Stairways shall be a minimum _______________ wide at all points above the permit-
ted handrail height and below the required headroom height.
a. 30 inches b. 34 inches
c. 36 inches d. 38 inches
R311.7.1
Reference __________
7. Where a handrail is provided on one side of a stairway, what is the minimum required
clear width at and below the handrail height?
a. 27 inches b. 29 inches
1
c. 31 /2 inches d. 36 inches
R311.7.1
Reference __________
9. The maximum variation between the greatest riser height and the smallest riser
height within any flight of stairs shall be _______________ .
1 3
a. /4 inch b. /8 inch
1 5
c. /2 inch d. /8 inch
R311.7.5.1
Reference __________
11. Unless the stair has a total rise of no more than 30 inches, the opening between treads
at open risers shall be such that a minimum _______________ sphere shall not pass
through.
a. 3-inch b. 4-inch
c. 6-inch d. no limitation is mandated
R311.7.5.1
Reference __________
12. In the identification of flood hazard areas, areas that have been determined to be sub-
ject to maximum wave heights of _______________ are not required to be desig-
nated coastal high-hazard areas feet unless subject to high-velocity wave action or
wave-induced erosion.
a. 3 b. 4
c. 5 d. 6
R322.3
Reference __________
13. What is the maximum riser height permitted for spiral stairways?
a. 73/4 inches b. 8 inches
1
c. 8 /4 inches d. 91/2 inches
R311.7.10.1
Reference __________
14. Stairway handrail height shall be, measured vertically from the nosing of the treads,
a minimum of _______________ and a maximum of _______________.
a. 30 inches, 34 inches b. 30 inches, 38 inches
c. 34 inches, 38 inches d. 34 inches, 42 inches
R311.7.8.1
Reference __________
16. A Type I handrail having a circular cross section shall have a minimum outside
diameter of _______________ and a maximum outside diameter of
______________.
a. 1 1/4 , 2 inches b. 1 1/4 , 2 5/8 inches
c. 1 1/2 , 2 inches d. 1 1/2 , 2 5/8 inches
R311.7.8.5, #1
Reference __________
17. A porch, balcony or similar raised floor surface more than 30 inches above the floor
or grade below shall be provided with a guard having a minimum height of
_______________.
a. 32 inches b. 34 inches
c. 36 inches d. 42 inches
R312.1.2
Reference __________
18. Required guards on open sides of raised floor areas shall be provided with intermedi-
ate rails or ornamental closures such that a minimum _______________ sphere can-
not pass through.
a. 3-inch b. 4-inch
c. 6-inch d. 9-inch
R312.1.3
Reference __________
19. Which one of the following areas in a dwelling unit does not specifically require the
installation of a smoke alarm?
a. basement b. living room
c. habitable attic d. sleeping room
R314.3
Reference __________
20. Where gypsum wallboard is used to separate foam plastic from the interior of the
dwelling, the separation shall be minimum __________ gypsum board.
1 1
a. /2-inch b. /2-inch Type X
5 5
c. /8-inch d. /8-inch Type X
R316.4
Reference __________
21. When carbon monoxide alarms are required in new construction, they shall be
installed _______________
a. within every bedroom
b. on all floor levels of multistory units
c. outside of each separate sleeping area
d. in the garage
R315.3
Reference __________
22. An automatic residential fire sprinkler system shall be provided in all buildings con-
taining _______________ or more townhouses.
a. 3 (all townhouses require a sprinkler system)
b. 8
c. 16
d. sprinkler systems are not required in townhouses
R313.1
Reference __________
23. In new construction, carbon monoxide alarms are required in dwelling units
_______________.
a. where fuel-fired appliances are installed
b. that have attached garages with an opening to the dwelling
c. with habitable space below grade
d. either a or b
R313.1
Reference __________
24. Unless they are made of pressure preservatively treated or naturally durable wood,
wood framing members that rest on masonry or concrete exterior foundation walls
shall be located a minimum of _______________ from exposed ground.
a. 6 inches b. 8 inches
c. 12 inches d. 18 inches
R317.1, #2
Reference __________
25. In the establishment of a design flood elevation, the depth of peak elevation of flood-
ing for a _______________ flood is used.
a. 10-year b. 20-year
c. 50-year d. 100-year
R322.1.4, #1
Reference __________
26. Where stair risers are not vertical, they shall be sloped under the tread above at a
maximum angle of _______________ from the vertical.
a. 10° b. 15°
c. 22° d. 30°
R311.7.5.1
Reference __________
27. Where foam plastic is spray applied to a sill plate without a thermal barrier, it shall
have a maximum density of _______________ pcf.
a. 1.0 b. 1.5
c. 2.0 d. 3.0
R316.5.11, #2
Reference __________
28. The maximum width above the recess of a Type II handrail shall be
_______________ inches.
a. 11/2 b. 2
c. 25/8 d. 23/4
R311.7.8.5, #2
Reference __________
29. Handrails shall be provided on at least one side of a stairway having a minimum of
_______________ risers.
a. 2 b. 3
c. 4 d. 5
R311.7.8
Reference __________
30. What is the minimum required clear opening for an egress door from a dwelling unit?
a. 32 inches by 78 inches b. 32 inches by 80 inches
c. 36 inches by 78 inches d. 36 inches by 80 inches
R311.2
Reference __________
31. Where the door does not swing over the landing, the exterior landing at a required
egress door shall be located a maximum of _______________ inches below the top
of the threshold.
a. 7 b. 71/2
c. 73/4 d. 8
R311.3.1, Exception
Reference __________
32. Where nosings are required on a stairway with solid risers, the nosings shall extend a
minimum of _______________ inch(es) and a maximum of _______________
inch(es) beyond the risers
1 3
a. /2, 1 b. /4, 11/4
c. 1, 11/2 d. 11/4, 2
R311.7.5.3
Reference __________
33. Address numbers used for building identification shall have a minimum height of
_______________ inches.
a. 4 b. 6
c. 8 d. 9
R319.1
Reference __________
34. Openings for required guards on the sides of stair treads shall be provided with inter-
mediate rails or ornamental closures such that a minimum _______________ sphere
cannot pass through.
a. 3 1/2 b. 4
c. 4 3/8 d. 6
R312.1.3, Exception 2
Reference __________
35. Where a safe room is constructed as a storm shelter in order to provide safe refuge
from high winds, the room shall be constructed in accordance with
_______________.
a. ICC/NSSA-500 b. CPSC 16 CFR, Part 1201
c. DOC PS 1-07 d. FEMA TB-2—93
R323.1
Reference __________