Quiz

Study Session 11
IRC Chapters 15, 16 and 19

1. Screws that join clothes dryer exhaust ducts may protrude a maximum of
_______________ inch into the inside of the duct.
a. 0, the use of screws is prohibited
b. 1/8
c. 3/16
d. 1/4
M1502.4.2
Reference _________________

2. Unless modified by the manufacturer’s installation instructions, what is the maximum


permitted length of a clothes dryer exhaust duct when measured from the dryer location
to the outlet termination?
a. 18 feet b. 25 feet
c. 30 feet d. 35 feet
M1502.4.5.1
Reference _________________

3. Unless modified by the manufacturer’s installation instructions or determined by engineering


calculation, what is the maximum permitted length of a clothes dryer exhaust duct that has one
6-inch-radius smooth 90-degree elbow and two 6-inch-radius smooth 45-degree elbows?
a. 25 feet, 0 inches b. 28 feet, 6 inches
c. 31 feet, 3 inches d. 35 feet, 0 inches
Table M1502.4.5.1
Reference _________________

286 2018 IRC Study Companion


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

4. Which of the following requirements is not applicable to a duct serving a range


hood?
a. It shall have a smooth interior surface.
b. It shall be airtight.
c. It shall be equipped with a backdraft damper.
d. It may terminate in an attic space.
M1503.3
Reference _________________

5. When serving a domestic kitchen cooking appliance equipped with a down-draft


exhaust system, a schedule 40 PVC exhaust duct shall extend a maximum of
_______________ above grade outside the building.
a. 1 inch b. 6 inches
c. 12 inches d. 36 inches
M1503.4, Exception, #4
Reference ________________

6. A domestic open-top broiler unit shall be provided with a minimum clearance of


_______________ between the hood and the underside of combustible material or
cabinets.
a. 0 inches; no clearance is required
b. 1/4 inch
c. 1/2 inch
d. 1 inch
M1503.2.1
Reference _______________

7. For a domestic open-top boiler unit, a minimum of _______________ shall be


maintained between the cooking surface and combustible material or cabinet.
a. 24 inches b. 28 inches
c. 30 inches d. 32 inches
M1503.2.1
Reference ________________

Study Session 11 287


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

8. Heating equipment connected to an above-ground duct system shall be designed to


limit discharge air temperature to a maximum of _______________.
a. 125°F b. 200°F
c. 225°F d. 250°F
M1601.1.1, #1
Reference ________________

9. Where ductwrap is installed as a duct insulation material, the installed thickness


used to determine its R-value shall be assumed to be __________ percent of nomi-
nal thickness.
a. 50 b. 75
c. 90 d. 100
M1601.3, #4.2
Reference ________________

10. Return air for heating, ventilation and air conditioning systems shall not be taken
from a kitchen unless the openings serve only the kitchen and are located a mini-
mum of __________ feet from any cooking appliances.
a. 5 b. 6
c. 10 d. 12
M1602.2, #4, Exception 1
Reference _________________

11. Gypsum board may be used in the construction of a return air plenum in an above-
ground duct system, provided the maximum air temperature is _______________
and the exposed surfaces are not subject to condensation.
a. 125°F b. 150°F
c. 180°F d. 210°F
M1601.1.1, #5
Reference ________________

12. What is the maximum flame spread index permitted for materials used to construct
above-ground duct systems?
a. 25 b. 75
c. 200 d. 450
M1601.1.1, #6
Reference _________________

288 2018 IRC Study Companion


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

13. Where used in an underground duct system, the maximum permitted duct tempera-
ture for plastic ducts shall be _______________ .
a. 125°F b. 150°F
c. 180°F d. 210°F
M1601.1.2
Reference _______________

14. When protected by concrete, metal ducts installed in an underground duct system
shall be encased with a minimum thickness of _______________.
a. 1 inch b. 2 inches
c. 3 inches d. 4 inches
M1601.1.2
Reference _________________

15. As a general rule, duct coverings and linings shall have a maximum flame spread
index of _______________ and a maximum smoke-developed index of
_______________.
a. 25, 50 b. 25, 200
c. 50, 200 d. 50, 450
M1601.3, #1
Reference ________________

16. External reflective duct insulation shall be identified at maximum intervals of


_______________ with the name of the manufacturer, the thermal resistance R-
value, the flame spread index and the smoke-developed index.
a. 3 feet b. 5 feet
c. 6 feet d. 10 feet
M1601.3, #3
Reference_________________

17. Where vibration isolators are installed between mechanical equipment and metal
ducts, they shall have a maximum length of _______________.
a. 6 inches b. 10 inches
c. 12 inches d. 24 inches
M1601.2
Reference________________

18. Clothes dryer exhaust ducts shall be __________ inches nominal in diameter.
a. 3 b. 31/2
c. 4 d. 5
M1502.4.1
Reference____________________

Study Session 11 289


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

19. In an existing structure where a modification is being made to an under-floor ple-


num, an under-floor space used as a supply plenum shall be formed by materials
having a maximum flame spread rating of _______________ .
a. 25 b. 50
c. 75 d. 200
M1601.5.2
Reference____________________

20. Where the under-floor space is permitted to be used as a supply plenum, a duct
shall extend from the furnace supply outlet to a minimum of _______________
inch(es) below the combustible framing.
a. 1 b. 3
c. 6 d. 8
M1601.5.3
Reference____________________

21. Unless in compliance with the manufacturer’s design criteria or verified by the
installer or a third party, the maximum length of a 4-inch smooth-wall exhaust duct
shall be __________ where the fan airflow rating is 100 cfm.
a. unlimited b. 42 feet
c. 10 feet d. 0 feet (prohibited)
M1504.2
Reference____________________

22. Range hood exhaust systems capable of exhausting more than __________ cubic
feet per minute shall be mechanically or naturally provided with makeup air at a
rate approximately equal to the exhaust air rate.
a. 100 b. 200
c. 300 d. 400
M1503.6
Reference____________________

23. Air exhaust openings shall terminate a minimum of _______________ feet from
property lines.
a. 3 b. 5
c. 8 d. 10
M1504.3, #1
Reference____________________

290 2018 IRC Study Companion


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

24. Built-in or freestanding ranges shall have a minimum vertical clearance of


_______________ above the cooking top to an unprotected combustible construc-
tion.
a. 24 inches b. 30 inches
c. 32 inches d. 36 inches
M1901.1
Reference____________________

25. Sauna heaters shall be equipped with a thermostat that will limit room temperature to
a maximum of _______________ .
a. 120°F b. 140°F
c. 172°F d. 194°F
M1902.4
Reference____________________

26. A mechanically ventilated kitchen area shall be provided with a minimum ventilation
rate of _______________ cfm where continuous ventilation is utilized.
a. 20 b. 25
c. 50 d. 100
M1505.4.4
Reference____________________

27. A bathroom ventilated by an intermittent mechanical means shall have a minimum


mechanical exhaust capacity of _______________ cfm.
a. 20 b. 25
c. 50 d. 100
M1505.4.4
Reference____________________

28. The access through the floor to an existing under-floor plenum shall provide a mini-
mum opening size of _______________.
a. 18 inches by 24 inches b. 20 inches by 24 inches
c. 22 inches by 30 inches d. 24 inches by 30 inches
M1601.5.4
Reference____________________

Study Session 11 291


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

29. Where an under-floor space is used as a supply plenum in an existing structure, the
furnace shall be equipped with an approved automatic control that limits the outlet air
temperature to a maximum of _______________ °F.
a. 150 b. 200
c. 225 d. 250
M1601.5.5
Reference____________________

30. Where the thermostat used to limit sauna room temperature is not an integral part of
the sauna heater, the heat-sensing element shall be located a maximum of
_______________ inches below the ceiling.
a. 3 b. 4
c. 6 d. 8
M1902.4
Reference____________________

31. Unless modified by the manufacturer's installation instructions, a clothes dryer


exhaust duct shall terminate outside of the building a minimum of _______________
feet in any direction from openings into the building.
a. 2 b. 3
c. 5 d. 10
M1502.3
Reference____________________

32. A transition duct for a clothes dryer exhaust system is limited to a maximum length of
_______________ feet.
a. 3 b. 5
c. 6 d. 8
M1502.4.3
Reference____________________

33. Where aluminum foil is installed on the exterior of insulation on cooling supply ducts
that pass through unconditioned space conducive to condensation, a minimum foil
thickness of __________ mil(s) is required.
a. 1 b. 2
c. 3 d. 4
M1601.4.6, #1
Reference____________________

292 2018 IRC Study Companion


Copyright © 2018 ICC. ALL RIGHTS RESERVED. Accessed by Ryan Young (ryoung2@acpsd.net), (Aiken County Career & Technology Center) Order Number #100800446 on Dec 12, 2019 05:30 AM (PST) pursuant
to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED
REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100800446

34. Crimp joints for round metal ducts shall have a minimum contact lap of
_______________ inch(es).
a. 3/4 b. 1
c. 11/2 d. 2
M1601.4.2
Reference____________________

35. Unless in conformance with the criteria for underground duct systems, ducts shall be
installed with a minimum of _______________ inches separation from earth.
a. 3 b. 4
c. 6 d. 12
M1601.4.8
Reference____________________

Study Session 11 293