Professional Documents
Culture Documents
: ________
MULTIPLE CHOICE
4. What is the minimum number of LAV for 200 males? (Assembly Places
- Theatres, Auditoriums, Convention Halls, etc. - for permanent
employee use)
a. 2 c. 4
b. 3 d. 5
Page 1 of 13
https://marcusaustria.com/plumbing
7. The invert of the inlet pipe shall be at a level not less than
____ above the invert of the outlet pipe.
a. 32 mm c. 40.8 mm
b. 38 mm d. 50.8 mm
10. Shall not allow the use of his/her license as registered Master
Plumber for a fee to an unlicensed Master Plumber in plumbing works
without his/her personal supervision.
a. Code of Ethics No. 1 c. Code of Ethics No. 5
b. Code of Ethics No. 3 d. Code of Ethics No. 7
14. Distribution boxes shall be designed to insure ____ flow and shall
be installed on a level concrete slab in natural or compacted soil.
a. equal c. more
b. less d. none of the above
Page 2 of 13
https://marcusaustria.com/plumbing
19. Where two or more drain lines are installed, an approved _____ of
sufficient size to receive lateral lines shall be installed at the
head of each disposal field.
a. distribution box c. septic tank
b. seepage pit d. disposal field
21. All sections of a plumbing drainage and vent system must be tested
with
a. water c. air or water
b. any liquid d. air
22. The inverts of all outlets shall be level and the invert of the
inlet shall be at least ____ above the outlets.
a. 25.4 mm c. 101.6 mm
b. 50.8 mm d. 104.6 mm
Page 3 of 13
https://marcusaustria.com/plumbing
25. Tube made of plastic material and colored black. The cross-
sectional shape is normally oval and is denoted by its outside
diameter or O.D. Normally used as water service connection from
main to meter.
a. Polyethylene c. PVC
b. Polybutylene d. PVDF
30. What is the minimum number of WC for 100 males? (Assembly Places
- Theatres, Auditoriums, Convention Halls, etc. - for public use)
a. 1 c. 3
b. 2 d. 4
31. What is the minimum pressure used in water test for drainage
system?
a. 15 psi c. 15 ft head
b. 10 psi d. 10 ft head
32. All water supply, drainage, venting system and all fixtures and
their traps complete with their connection.
a. plumbing system c. sewer system
b. piping system d. sanitary system
Page 4 of 13
https://marcusaustria.com/plumbing
37. A branch vent that performs its functions for two (2) or more
traps.
a. vent system c. individual vent
b. relief vent d. group vent
38. On what date the National Plumbing Code of the Philippines was
approved?
a. June 18, 1955 c. January 28, 1959
b. June 18, 1954 d. January 18, 1956
39. What is the minimum pressure required to test water supply system?
a. 100% of used water pressure
b. 150% of used water pressure
c. 200% of used water pressure
d. 250% of used water pressure
40. The part of the plumbing system extending 0.6 m from the inner
face of the foundation wall of the building to the junction with
another sewer
a. house sewer c. sanitary sewer
b. storm sewer d. building drain
Page 5 of 13
https://marcusaustria.com/plumbing
42. Allowing for friction and other pressure loss the available water
pressure for fixture is ____________.
a. 30 psi c. 15 psi
b. 20 psi d. 45 psi
43. What is the maximum fixture unit loading allowed on 51-inch waste
stack?
a. four c. sixteen
b. six d. two
44. That part of plumbing system extending from point 0.6-m of the
inner face of the foundation wall of building to the junction with
another sewer.
a. house sewer c. sanitary sewer
b. storm sewer d. building drain
45. The drainage system or any part thereof shall not be covered until
a. After a plumbing inspector has been called
b. It has been tested
c. It has been inspected
d. It has been approved
47. The air test for a plumbing drainage and vent system shall be made
by attaching the air compressor or other test apparatus to
a. The lowest fixture outlet available
b. The highest vent opening
c. Any suitable opening
d. A dishwasher waste opening
Page 6 of 13
https://marcusaustria.com/plumbing
52. Is a device located at the bottom of the tank for the purpose of
flushing water closet and similar fixtures
a. Gate valve c. Flushometer valve
b. Flush valve d. Flush tank
55. The lowest portion of the interior part of any pipe or conduit
that is not vertical
a. Leader c. Grade
b. Lateral d. Invert
57. The side walls shall extend at least ___ above the liquid depth.
a. 304.8 mm c. 228.6 mm
b. 50.8 mm d. 104.6 mm
Page 7 of 13
https://marcusaustria.com/plumbing
64. A trap depending on movable parts to retain its seal may _______.
a. be used for fixtures with clear water waste only
b. not be used under any circumstances
c. be used if first approved by plumbing official
d. be used when approved by ASME Standards
65. What do you call to the combination of two elements, hydrogen and
oxygen?
a. ice c. liquid
b. water d. fluid
66. What is the maximum distance allowed for the trap of the floor
drain to be placed below the finished floor line to facilitate
cleaning in case of line trouble?
a. 300 mm c. 500 mm
b. 400 mm d. 600 mm
67. Equipment which includes all valves and controls used in the
plumbing system which are required to be accessible or readily
accessible.
Page 8 of 13
https://marcusaustria.com/plumbing
68. The inlet and outlet pipe or baffle shall extend _____ above and
at least 304.8 mm below the water surface.
a. 101.6 mm c. 104.6 mm
b. 102.6 mm d. 106.6 mm
70. The size of a trap arm may change direction without the use of a
cleanout when such direction does not exceed 90º.
a. Less than 76mm diameter
b. Larger than 76mm diameter
c. Less than 102mm diameter
d. Larger than 76mm diameter
75. When floor drainage is required for a cold storage room used for
storing or holding food or drink, the drain must be connected to
the sanitary drainage system through a
a. direct waste
Page 9 of 13
https://marcusaustria.com/plumbing
76. Who shall appoint the Board of Examiners for Master Plumber?
a. Commissioner of Civil Service
b. PRC Commissioner
c. President of the Philippines
d. BOMP
77. When provided with water outlets for such space, a 610 mm width of
wash sink or 457 mm diameter of a circular basin, shall be _____.
a. considered equivalent to one lavatory
b. considered equivalent to one water closet
c. considered equivalent to one kitchen sink
d. considered equivalent to one floor drain
78. What is the urinal per male ratio for principal worship places?
a. 1 per 150 c. 1 per 200
b. 1 per 40 d. 1 per 55
Page 10 of 13
https://marcusaustria.com/plumbing
83. What is the length of the pipe that should be added on the top of
the highest fixture level to eliminate water hammer?
a. 150 mm c. 800 mm
b. 200 mm d. 300 mm
84. The cover of the septic tank shall be at least ____ above the back-
vent openings.
a. 304.8 mm c. 228.6 mm
b. 50.8 mm d. 106.6 mm
85. The vertical distance from the “Grade Line” to the highest point
of the coping of a flat roof or to the top line of a mansard roof
or to the average height of the highest gable of a pitch or hip-
roof.
a. Branch interval c. Storey
b. Height of building d. None of the above
88. What is the maximum interval of vertical supports for lead piping?
a. 3 m c. 4 m
b. 1.2 m d. 1 m
90. The lead shall be caulked thoroughly at the inside and outside
edges of the joint. After caulking, the finished joint shall not
extend more than ___ below the rim of the hub.
a. 25mm c. 3.2mm
b. 19mm d. 6.4mm
Page 11 of 13
https://marcusaustria.com/plumbing
92. The minimum wall thickness of a steel septic tank that can be
protected from corrosion internally and externally is
a. Ga. 12 c. Ga. 16
b. Ga. 14 d. Ga. 26
95. Two (2) walls opposite of differing heights - add _______ of wall
area above top of lower wall to the roof area.
a. 35% c. No additional area
b. 50% d. None of the above
96. A valve opened and closed by the fall and rise, respectively of an
attached ball floating on the surface of the liquid.
a. Ball joint c. Corp stop
b. Ball cock d. Curb stop
98. The maximum height above the trap for a clothes washer standpipe
receptor is ____.
a. 0.45 m c. 0.75 m
b. 0.60 m d. 0.80 m
END
Page 12 of 13
https://marcusaustria.com/plumbing
PLUMBING CODE
https://marcusaustria.com/plumbing
Page 13 of 13