You are on page 1of 13

Seat No.

: ________

MASTER PLUMBER COACH


plumbing exam made easy
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m.
-----------------------------------------------------------------------
PLUMBING CODE SET X

INSTRUCTION: Select the correct answer for each of the following


questions. Mark only one answer for each item by shading the box
corresponding to the letter of your choice on the answer sheet provided.
STRICTLY NO ERASURES ALLOWED.

MULTIPLE CHOICE

1. An act to regulate the trade of Master Plumber.


a. RA 1364 c. RA 6541
b. RA 1378 d. RA 9514

2. What do you call to this device that is being used to circulate


hot water to the plumbing system?
a. overhead feed
b. up feed
c. pump circuit system
d. hot water recirculating pump

3. Shall not act in an unprofessional manner and demand any


remuneration other than his/her original charges except for
additional services not covered in the basic contract.
a. Code of Ethics No. 1 c. Code of Ethics No. 5
b. Code of Ethics No. 3 d. Code of Ethics No. 7

4. What is the minimum number of LAV for 200 males? (Assembly Places
- Theatres, Auditoriums, Convention Halls, etc. - for permanent
employee use)
a. 2 c. 4
b. 3 d. 5

5. Shall not advertise in self-laudatory language, act in any manner


an engage in any practice which tend to bring dishonor to the
dignity of the Registered Master Plumber, the National Master
Plumbers association of the Philippines (NAMPAP) and the plumbing
profession.
a. Code of Ethics No. 1 c. Code of Ethics No. 5
b. Code of Ethics No. 3 d. Code of Ethics No. 7

6. It shall be unlawful for any person, firm or corporation, whether


acting as principal, servant, agent or employee, to do or cause to
be done any plumbing or drainage work for which a permit is
required without securing prior permit from the Office of the
Building Official having jurisdiction under the _____.
a. DPWH c. City Mayors
b. DILG d. All of the above

MASTER PLUMBER COACH


plumbing exam made easy

Page 1 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 2

PLUMBING CODE SET X

7. The invert of the inlet pipe shall be at a level not less than
____ above the invert of the outlet pipe.
a. 32 mm c. 40.8 mm
b. 38 mm d. 50.8 mm

8. The inlet compartment of any septic tank shall be _____ of the


total capacity of the tank, nor less than 2.0 m3 liquid capacity.
a. not less than two-thirds c. not less than one-half
b. not less than one-thirds d. not less than twice

9. The pipe or tubing that connects the outlet of a plumbing fixture


to the trap.
a. trap c. tailpiece
b. trap arm d. outlet

10. Shall not allow the use of his/her license as registered Master
Plumber for a fee to an unlicensed Master Plumber in plumbing works
without his/her personal supervision.
a. Code of Ethics No. 1 c. Code of Ethics No. 5
b. Code of Ethics No. 3 d. Code of Ethics No. 7

11. What is the minimum width of the inlet compartment of a septic


tank?
a. 600mm c. 900mm
b. 750mm d. 1500mm

12. It refers to the resistance delivered by streaming water with


fittings and inside surface of the pipe.
a. force c. pressure
b. friction d. velocity

13. Consists of two independently acting internally loaded check


valves, a differential pressure relief valve, four properly
located test cocks and two isolation gate valves.
a. DC c. RP
b. PVB d. AVB

14. Distribution boxes shall be designed to insure ____ flow and shall
be installed on a level concrete slab in natural or compacted soil.
a. equal c. more
b. less d. none of the above

15. To receive the discharge from aeration, what is installed at the


bottom portion of the soil stack where the house drain is
connected?
a. aerator c. Sovent system
b. deaerator d. ventilation

MASTER PLUMBER COACH


plumbing exam made easy

Page 2 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 3

PLUMBING CODE SET X

16. Airgap less than 25 mm shall only be approved as a permanent part


of a listed assembly that has been tested under actual backflow
conditions with vacuums of from
a. 0 to 65 cm. of mercury
b. 0 to 36 cm. of mercury
c. 0 to 60 cm. of mercury
d. 0 to 63.5 cm. of mercury

17. Fixture outlets shall not be connected to the horizontal excreta


drainage piping system within how many meters from any vertical to
horizontal change of direction of a stack containing suds-
producing fixtures.
a. 3.0m c. 1.2m
b. 2.4m d. 1.5m

18. It is a piece of a framework that expels sewage and greywater from


a building and controls pneumatic stress in the waste-framework
channels to help free stream.
a. Sanitary sewer system c. DWV system
b. Storm sewer d. Vent system

19. Where two or more drain lines are installed, an approved _____ of
sufficient size to receive lateral lines shall be installed at the
head of each disposal field.
a. distribution box c. septic tank
b. seepage pit d. disposal field

20. A hose connection with two-gated outlets permitting two


connections of the same or smaller coupling diameter to be taken
from a single supply line.
a. Wye c. Sanitary tee
b. Tee d. 1/8 bend

21. All sections of a plumbing drainage and vent system must be tested
with
a. water c. air or water
b. any liquid d. air

22. The inverts of all outlets shall be level and the invert of the
inlet shall be at least ____ above the outlets.
a. 25.4 mm c. 101.6 mm
b. 50.8 mm d. 104.6 mm

23. That portion of a building included between the upper surface of


any floor and the upper surface of the floor next above.
a. Branch c. Riser
b. Storey d. Stack

MASTER PLUMBER COACH


plumbing exam made easy

Page 3 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 4

PLUMBING CODE SET X

24. The requirements for installation of grease interceptors exclude


a. fast-food restaurants
b. apartment buildings with up to 100 dwelling units
c. hospitals
d. hotels

25. Tube made of plastic material and colored black. The cross-
sectional shape is normally oval and is denoted by its outside
diameter or O.D. Normally used as water service connection from
main to meter.
a. Polyethylene c. PVC
b. Polybutylene d. PVDF

26. A valve actuated by stem screw, and hand wheel, suited on


installation that calls for throttling.
a. foot valve c. angle valve
b. gate valve d. globe valve

27. The 22 basic Principles of master plumbing is enumerated in what


section of RA 1378?
a. Section 2 c. Section 12
b. Section 5 d. Section 13

28. The pressure existing without any flow motion.


a. Residual pressure c. Atmospheric pressure
b. Static pressure d. Negative pressure

29. What is the minimum of number of water closet required at office


with 20 persons?
a. 1 c. 3
b. 2 d. 4

30. What is the minimum number of WC for 100 males? (Assembly Places
- Theatres, Auditoriums, Convention Halls, etc. - for public use)
a. 1 c. 3
b. 2 d. 4

31. What is the minimum pressure used in water test for drainage
system?
a. 15 psi c. 15 ft head
b. 10 psi d. 10 ft head

32. All water supply, drainage, venting system and all fixtures and
their traps complete with their connection.
a. plumbing system c. sewer system
b. piping system d. sanitary system

33. It is the required pressure to test water supply system.

MASTER PLUMBER COACH


plumbing exam made easy

Page 4 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 5

PLUMBING CODE SET X

a. 100% of used water pressure


b. 150% of used water pressure
c. 200% of used water pressure
d. 250% of used water pressure

34. Inlet and outlet pipe fittings or baffles, and compartment


partitions shall have a free vent area _______ of the house sewer
or private sewer discharging therein to provide free ventilation
above the water surface from the disposal field or seepage pit
through the septic tank, house sewer, and stack to the outer air.
a. equal to the required cross-sectional area
b. 1.5 times the required cross-sectional area
c. twice the required cross-sectional area
d. 2 ½ times the required cross-sectional area

35. What is the slope of a waste pipe with a minimum size of 3”


horizontal pipe?
a. ¾ inch per foot c. 1 inch per foot
b. ½ inch per foot d. ¼ inch per foot

36. What is the minimum size of water supply pipe to a lavatory?


a. 13 mm c. 10 mm
b. 19 mm d. 25 mm

37. A branch vent that performs its functions for two (2) or more
traps.
a. vent system c. individual vent
b. relief vent d. group vent

38. On what date the National Plumbing Code of the Philippines was
approved?
a. June 18, 1955 c. January 28, 1959
b. June 18, 1954 d. January 18, 1956

39. What is the minimum pressure required to test water supply system?
a. 100% of used water pressure
b. 150% of used water pressure
c. 200% of used water pressure
d. 250% of used water pressure

40. The part of the plumbing system extending 0.6 m from the inner
face of the foundation wall of the building to the junction with
another sewer
a. house sewer c. sanitary sewer
b. storm sewer d. building drain

41. What is the minimum size of p-trap for floor drain?


a. 2” c. 4”
b. 3” d. 6”

MASTER PLUMBER COACH


plumbing exam made easy

Page 5 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 6

PLUMBING CODE SET X

42. Allowing for friction and other pressure loss the available water
pressure for fixture is ____________.
a. 30 psi c. 15 psi
b. 20 psi d. 45 psi

43. What is the maximum fixture unit loading allowed on 51-inch waste
stack?
a. four c. sixteen
b. six d. two

44. That part of plumbing system extending from point 0.6-m of the
inner face of the foundation wall of building to the junction with
another sewer.
a. house sewer c. sanitary sewer
b. storm sewer d. building drain

45. The drainage system or any part thereof shall not be covered until
a. After a plumbing inspector has been called
b. It has been tested
c. It has been inspected
d. It has been approved

46. Cast iron piping is 10 ft length installed horizontally, shall be


supported at intervals of not more than ______.
a. 12 ft c. 5 ft
b. 15 ft d. 10 ft

47. The air test for a plumbing drainage and vent system shall be made
by attaching the air compressor or other test apparatus to
a. The lowest fixture outlet available
b. The highest vent opening
c. Any suitable opening
d. A dishwasher waste opening

48. The waste pipe from a domestic dishwashing machine connected to a


food-waste disposer unit must have a/an _______.
a. Soft-seat check valve c. Backflow preventer valve
b. Approved air-gap fitting d. Nonrising stem gate valve

49. The drainage pipe running from outside a buildings foundation to


the main sewer.
a. Building drain c. Waste drain
b. Sewer d. Storm drain

50. To ensure effectiveness, the wastes entering the grease


interceptor must not exceed the manufacturer’s rated capacity. For
this reason, a ______ must be installed.
a. clarifier c. swing check valve
b. balancing valve d. flow control

MASTER PLUMBER COACH


plumbing exam made easy

Page 6 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 7

PLUMBING CODE SET X

51. A freestanding drinking fountain may connect to the drainage system


of a building _________.
a. by using an approved air-gap fitting
b. by an indirect waste method
c. through an individual p-trap only
d. provided the waste outlet is no more than 10 feet from a vent

52. Is a device located at the bottom of the tank for the purpose of
flushing water closet and similar fixtures
a. Gate valve c. Flushometer valve
b. Flush valve d. Flush tank

53. The scope of plumbing practice is enumerated in what section of


the Plumbing Law?
a. Section 2 c. Section 12
b. Section 5 d. Section 13

54. Joints in lead pans or liners shall be ______.


a. Wiped c. Threaded
b. Caulked d. Burned

55. The lowest portion of the interior part of any pipe or conduit
that is not vertical
a. Leader c. Grade
b. Lateral d. Invert

56. Where there is exposure to skin contamination with poisonous,


infectious, or irritating materials, provide one lavatory for
a. each three persons c. each five persons
b. each four persons d. each six persons

57. The side walls shall extend at least ___ above the liquid depth.
a. 304.8 mm c. 228.6 mm
b. 50.8 mm d. 104.6 mm

58. Any joint or seam obtained by the joining of metal parts in a


plastic molten state.
a. welded joint c. both a & b
b. seam d. none of the above

59. Joints in copper pans or liners shall be ______.


a. Soldered c. either a or b
b. Brazed d. neither

60. All whirlpool bathtubs shall comply with the following


requirements, except
a. a removable panel of sufficient dimension shall be provided for
access to the pump

MASTER PLUMBER COACH


plumbing exam made easy

Page 7 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 8

PLUMBING CODE SET X

b. the circulation pump shall be located below the crown weir of


the trap
c. the pump and the circulation piping shall be self-draining to
minimize water retention
d. suction fittings on whirlpool bathtubs shall comply with the
listed standards

61. A baffle type fitting shall have the equivalent cross-sectional


area of the connecting sewer pipe and not less than a ____
horizontal dimension when measured at the inlet and outlet pipe
inverts.
a. 101.6 mm c. 104.6 mm
b. 102.6 mm d. 106.6 mm

62. Horizontally installed piping must be supported at sufficiently


close intervals to ________.
a. carry the weight of the pipe
b. carry the weight of the pipe and its content
c. prevent strains or stresses
d. prevent sagging

63. All piping installed in corrosive type material shall be ________.


a. first approved by the plumbing official
b. supported properly
c. protected properly
d. in accordance with manufacturer’s recommendations

64. A trap depending on movable parts to retain its seal may _______.
a. be used for fixtures with clear water waste only
b. not be used under any circumstances
c. be used if first approved by plumbing official
d. be used when approved by ASME Standards

65. What do you call to the combination of two elements, hydrogen and
oxygen?
a. ice c. liquid
b. water d. fluid

66. What is the maximum distance allowed for the trap of the floor
drain to be placed below the finished floor line to facilitate
cleaning in case of line trouble?
a. 300 mm c. 500 mm
b. 400 mm d. 600 mm

67. Equipment which includes all valves and controls used in the
plumbing system which are required to be accessible or readily
accessible.

MASTER PLUMBER COACH


plumbing exam made easy

Page 8 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 9

PLUMBING CODE SET X

a. Machine c. Regulating Equipment


b. Controls d. Pipes

68. The inlet and outlet pipe or baffle shall extend _____ above and
at least 304.8 mm below the water surface.
a. 101.6 mm c. 104.6 mm
b. 102.6 mm d. 106.6 mm

69. Distribution boxes shall be coated on the inside with a ______ or


other approved method acceptable to the Administrative Authority.
a. bituminous coating c. rubber coating
b. paint coating d. all of the above

70. The size of a trap arm may change direction without the use of a
cleanout when such direction does not exceed 90º.
a. Less than 76mm diameter
b. Larger than 76mm diameter
c. Less than 102mm diameter
d. Larger than 76mm diameter

71. Cleanouts on the seal of a trap are prohibited on ________.


a. Residential lavatory traps c. Stall shower traps
b. Commercial sink traps d. Barber shop sink traps

72. Any part of a piping system that extends horizontally at an


approved grade, with or without vertical extensions from the main
to plumbing fixtures.
a. Lateral c. Branch drain
b. Continuous pipe d. Branch

73. Any part of a drainage system that extends horizontally at a slope


from a soil or waste stack, with or without lateral or vertical
extensions, on two or more floors.
a. Horizontal branch
b. Horizontal pipe
c. Fixture drain
d. Combination fixture drain

74. Satisfactory hanger which supports any piping must be


a. of same material as piping
b. accessible
c. same size as pipe used
d. of sufficient strength

75. When floor drainage is required for a cold storage room used for
storing or holding food or drink, the drain must be connected to
the sanitary drainage system through a
a. direct waste

MASTER PLUMBER COACH


plumbing exam made easy

Page 9 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 10

PLUMBING CODE SET X

b. floor drain with strainer


c. trap with trap primer
d. indirect waste

76. Who shall appoint the Board of Examiners for Master Plumber?
a. Commissioner of Civil Service
b. PRC Commissioner
c. President of the Philippines
d. BOMP

77. When provided with water outlets for such space, a 610 mm width of
wash sink or 457 mm diameter of a circular basin, shall be _____.
a. considered equivalent to one lavatory
b. considered equivalent to one water closet
c. considered equivalent to one kitchen sink
d. considered equivalent to one floor drain

78. What is the urinal per male ratio for principal worship places?
a. 1 per 150 c. 1 per 200
b. 1 per 40 d. 1 per 55

79. A comprehensive term, including all constructions for collection,


transportation, pumping, treatment and final disposition of
sewage.
a. plumbing system
b. sewerage system
c. sewerage or sewerage works
d. none of the above

80. ________ is a device designed and installed to separate and retain


deleterious, hazardous or undesirable matters from normal wastes
and permits normal sewage or liquid wastes to discharge into the
disposal terminal by gravity.
a. Interceptor c. Both a & b
b. Clarifier d. Grease trap

81. ______ for “Sacrarium” cupsink at church altar and Baptistries


font outlet shall discharge direct to the ground and not connected
to the sanitary drainage system.
a. water drain c. wastewater drain
b. waste d. none of the above

82. What is the minimum thickness of copper pans or liners?


a. Gauge No. 24 B & S or 0.5 mm thick
b. Gauge No. 20 B & S or 0.8 mm thick
c. Gauge No. 16 U.S. B&S or 1.6 mm thick
d. None of the above

MASTER PLUMBER COACH


plumbing exam made easy

Page 10 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 11

PLUMBING CODE SET X

83. What is the length of the pipe that should be added on the top of
the highest fixture level to eliminate water hammer?
a. 150 mm c. 800 mm
b. 200 mm d. 300 mm

84. The cover of the septic tank shall be at least ____ above the back-
vent openings.
a. 304.8 mm c. 228.6 mm
b. 50.8 mm d. 106.6 mm

85. The vertical distance from the “Grade Line” to the highest point
of the coping of a flat roof or to the top line of a mansard roof
or to the average height of the highest gable of a pitch or hip-
roof.
a. Branch interval c. Storey
b. Height of building d. None of the above

86. It refers to the pressure range measured over a period of 24 hours.


a. static pressure c. normal pressure
b. back pressure d. high pressure

87. A water closet consisting of a continuous trough containing water.


The trough extends under two or more adjacent seats. Prohibited by
health authorities for permanent installations.
a. Trough c. Latrine
b. Washdown d. Pail flush

88. What is the maximum interval of vertical supports for lead piping?
a. 3 m c. 4 m
b. 1.2 m d. 1 m

89. What is the water demand for shower head?


a. 7.5 gpm c. 12 gpm
b. 2.5 gpm d. 15 gpm

90. The lead shall be caulked thoroughly at the inside and outside
edges of the joint. After caulking, the finished joint shall not
extend more than ___ below the rim of the hub.
a. 25mm c. 3.2mm
b. 19mm d. 6.4mm

91. ln addition to the required incised marking, all hard-drawn copper


tubing shall be marked by means of a continuous and indelibly
colored stripe at least ___ in width
a. 1.8 mm c. 3.2 mm
b. 1.6 mm d. 6.4 mm

MASTER PLUMBER COACH


plumbing exam made easy

Page 11 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 12

PLUMBING CODE SET X

92. The minimum wall thickness of a steel septic tank that can be
protected from corrosion internally and externally is
a. Ga. 12 c. Ga. 16
b. Ga. 14 d. Ga. 26

93. What is the standard slope of the building drain?


a. 4% c. 1%
b. 2% d. ½%

94. Rainwater piping located on the exterior of a building using


galvanized sheet metal shall not be less than ______.
a. 26 Ga c. 28 Ga
b. 24 Ga d. 30 Ga

95. Two (2) walls opposite of differing heights - add _______ of wall
area above top of lower wall to the roof area.
a. 35% c. No additional area
b. 50% d. None of the above

96. A valve opened and closed by the fall and rise, respectively of an
attached ball floating on the surface of the liquid.
a. Ball joint c. Corp stop
b. Ball cock d. Curb stop

97. A flushometer valve is a device used to


a. Flush the contents from a toilet bowl
b. Discharge a predetermined quantity of water
c. Automatically reseal floor drains
d. Flush all surfaces of a floor-mounted urinal

98. The maximum height above the trap for a clothes washer standpipe
receptor is ____.
a. 0.45 m c. 0.75 m
b. 0.60 m d. 0.80 m

99. Expansion joints shall be acceptable in piping, except


a. vents c. steam
b. hot water d. cold water

100. A metallic sleeve, calked or join to opening in a pipe, into which


a plug is screwed that can be removed for cleaning or examining
the interior of the pipe.
a. flange c. threaded pipe
b. ferrule d. cast pipe

END

MASTER PLUMBER COACH


plumbing exam made easy

Page 12 of 13
https://marcusaustria.com/plumbing

MASTER PLUMBING REFRESHER


Sunday, January 23, 2022 09:00 a.m. – 06:00 p.m. Page 13

PLUMBING CODE SET X

MASTER PLUMBER COACH


plumbing exam made easy
https://marcusaustria.com/plumbing
ANSWER SHEET

PLUMBING CODE
https://marcusaustria.com/plumbing

MASTER PLUMBER COACH


plumbing exam made easy

Page 13 of 13

You might also like