HVAC SOLUTION GUIDE
LG Electronics Distributed by
http: / / www.lg.com
http: / / partner.lge.com
BENEFITS OF
LG BECON HVAC SOLUTION
002 / 003
WHY LG BECON HVAC SOLUTION
SMART MANAGEMENT
EASY EXPANDABILITY
ENERGY SAVING
PDI AC Smart 5
AC Manager 5 AC Ez Touch
004 / 005
WHY LG BECON HVAC SOLUTION
KEY BENEFITS
Energy Saving
LG BECON HVAC SOLUTION prevents energy waste through energy reduction solutions optimized for a variety of business
environments, providing excellent cost reduction.
Energy Management
Capacity Control
(Usage Graph & Navigation)
Smart Management
Comfort and convenience play a major factor in the effectiveness of an HVAC Control Solution. We provides smart management with
control and monitoring, as well as a more pleasant environment through an air purify solution anytime anywhere.
Environment Display
Air Purify Solution
(Temperature, Humidity, CO2, Air Quality Level)
IPv6 Network
Operation Trend View & Energy Report
(HTML5)
Easy Expandability
Integrated management of LG HVAC Control Solution links operations of LG Air conditioners with external systems for expanded coverage.
The embedded BMS enables direct connection with other systems without any additional BMS gateways to enable communication.
Units' operations (on / off, air flow adjustment, Etc) can be configured through triggers such as Air quality, humidity, CO2, and room
occupancy sensors. Also, 3rd Party Thermostat controllers are connectable with LG HVAC System.
EASY
EXPANDABILITY
006 / 007
WHY LG BECON HVAC SOLUTION
VARIOUS
INTEGRATED SOLUTIONS
Power Consumption Distribution Solution Energy Management Solution Refrigerant Leak Detection Solution Interlocking Solution Using Dry Contact
In case of shared power consumption in a building, a solution to distribute the Since HVAC systems use a significant portion of any building’s total amount of Real-time refrigerant leak detection ensures a safe environment. 3rd party thermostats can be used to control LG Air conditioners in a room by
power consumption amount per tenant might be necessary. Electricity charges can energy, the energy saving functions of a controller can make a big difference. When refrigerant concentration exceeds 6,000ppm for 5 seconds, using a multi point dry contact. The dry contact enables basic control of air
be billed to each tenant by using output from the LG Power Distribution Indicator The energy navigation function enables you to set target values for energy the indoor unit will stop operation and alert users with a buzzer or light switch conditioners as well as making it possible to report the status and any errors
(PDI). An administrator is able to check the power usage for each space and consumption over a certain period of time. In addition, to achieve that value, the (Dry contact option). impacting the indoor unit. The Standard III remote control has a DO port. With
date as needed. If the PDI is used in conjunction with an LG central controller, the administrator can set the energy saving logic in 7 steps and predict the expected this DO port, it is possible to interlock the indoor unit with 3rd party devices such
results can be exported to Excel. usage relative to the target value. Active self-management enables energy savings as lighting, a fan, or a radiator, based on things like operation mode or current
through out the building. temperature. The indoor unit can be interlocked with various types of input
WHM
(Watt Meter) ➌ Stops Operation such as card key-tag, door sensor, human detection sensor etc. so that the air
Pulse Signal (Option : ring alarm) conditioner is automatically operated. In addition, the dry contact option settings
enable operation of air conditioner to maintain proper temperature when the
70% occupant is absent. This solution makes sure that the room does not overheat or
become too cold when unoccupied so that energy cost can be saved.
Power 100 kWh PDI Compressor Capacity IDU Operation IDU Operation ➋ Senses
Control Ratio Control Level Refrigerant
Leakage
B Office C Office
20 kWh Target
30 kWh
A Office D Office ➊ Refrigerant
Forecasting Leakage
30 kWh 20 kWh
Refrigerant
leakage
detection
008 / 009
WHY LG BECON HVAC SOLUTION
VARIOUS
INTEGRATED SOLUTIONS
Easy Control Air Purify Solution Integration Solution with BMS Energy Management Solution
Wired remote controller is easy for usage. Anywhere! Anytime! Control IDU with Wi-Fi Modem through LG ThinQ. There are many BMS protocols used for the control of buildings’ various systems Since HVAC systems use a significant portion of any building’s total amount of
such as HVAC, lighting, power and security. LG has a wide range of gateway energy, the energy saving functions of a controller can make a big difference.
Convenient Air Quality Level Monitoring products for different protocols such as BACnet, Modbus, and LonWorks. The energy navigation function enables you to set target values for energy
• Flexible display • Easily Check Air Quality Status
- Dual display with air conditioner.
In addition, LG gateways include Stand-alone central control capability to act as a consumption over a certain period of time. In addition, to achieve that value, the
- PM10
- Zoom selected directory to - PM2.5
back-up controller of the BMS if needed. administrator can set the energy saving logic in 7 steps and predict the expected
increase legibility. - PM1.0 usage relative to the target value. Active self-management enables energy savings
Small / Medium size building Medium / Large size building
Visible - Graph View of measurement through out the building.
• Indoor CO2 level, Air Purify history Day, Week, Month, Year
Easy quality level, Humidity IDU ~ 64 : ACP LonWorks
LG ThinQ
• Navigation buttons, easy to use. • Alarm for filter change /
• Easy installation setting Remained time to change filters Air Purify Control
• Air Purify Set / Clear
IDU ~ 128 : AC Smart 5
(BACnet IP / Modbus TCP) 70%
Purification IDU ~ 64 : Modbus RTU
Energy Management IDU ~ 256 : ACP 5
(BACnet IP / Modbus TCP) Compressor Capacity IDU Operation IDU Operation
Mobile Remote Control Control Ratio Control Level
Users can check power consumption and • Using a Wi-Fi modem, control BMS System
running time report. (Weekly, Monthly, Yearly) and monitor air purify from your Target
Various energy managing settings such as LG ThinQ App. BMS Protocol
energy target setting, alarm pop-up indication, - Temp. / Mode / Fan / Air Flow Forecasting
and so on
time limit control and home leave operation are
available for efficient management.
* Wi-Fi modem (PWFMDD200) is an accessory.
010 / 011
WHY LG BECON HVAC SOLUTION
VARIOUS
INTEGRATED SOLUTIONS
Education AC Manager 5
Large capacity in compact size enhances space utilization
Public Facility AHU Comm.Kit
Suitable for large public facilities through group control
Total Control of Any Device Air Purify Total Solution Air Handling Unit (AHU) Solution Interlocking Solution by Using ACS IO Module
In order to manage multiple spaces and multiple buildings, the administrators Total management of air purify creates clean school environment for everyday. AHU is a suitable solution for cooling and heating in large space. With an LG AHU It is costly to introduce a BMS system to control multiple devices or systems in a
should be able to control systems from wherever they are. The LG central Using LG central controller, you can check the air condition of multiple zones at Comm.Kit (for both return air / supply air control) connected to the DX coil of the small building. With the ACS / ACU IO Module, various IO contact points
controller can be controlled from any web browser that supports HTML5. once and improve the overall air quality through simple control. AHU, LG VRF system can be applied to deliver conditioned air. (DI, DO, UI, AO) can be interlocked and integrated, while control is possible from
Now through the implementation of HTML5, the interface will look great and the LG central controller. This enables an efficient management of lighting, pumps
Air Quality Information
perform well on any device. - Air Quality Level Monitoring
and other devices in the building in conjunction with the HVAC system.
MULTI V 5
Air Purify Control Outdoor Unit
- Set / Clear
012 / 013
LINE UP
PREMTB100 PQRCVCL0QW PWLSSB21H (Heat Pump) PQCSZ250S0 PACP5A000 PLNWKB000 Premium (8 ports) PQNUD1S40 Simple Dry Contact PZCWRCG3 For MULTI V IV, 5 Return / Room Air Control
PWLSSB21C (Cooling Only) (Indoor Unit ~ 32) (Indoor Unit ~ 256) (Indoor Unit ~ 64) Standard (2 ports) PPWRDB000 PDRYCB000 PVDSMN000 PAHCMR000
BACnet IP / Modbus TCP
Standard III (Black) Wi-Fi Modem AC Ez Touch AC Manager 5 Modbus RTU gateway ACS IO Module Variable Water Flow
Remote Temperature Sensor
(Input / Output Module) Control Kit
PREMTBB10 PQRCVCL0Q For Indoor Unit PACEZA000 PACM5A000 PMBUSB00A PEXPMB000 Dry Contact for Thermostat PQRSTA0 For MULTI V WATER IV Discharge / Supply Air Control
PWFMDD200 (Indoor Unit ~ 64) (Indoor Unit ~ 8,192) PDRYCB300 PWFCKN000 PAHCMS000
Standard II (White) AC Smart 5 PI485 Chiller Option Kit Zone Controller Low Ambient Kit Controller Module
PREMTB001 PQRCHCA0QW PACS5A000 For Indoor Unit (ERV) PCHLLN000 Dry Contact for Thermostat 4 Zones by thermostat For MULTI V IV, 5 Main Module
(Simple for Hotel) (Indoor Unit ~ 128) PHNFP14A0 (For using universal input) ABZCA PRVC2 PAHCMM000
BACnet IP / Modbus TCP PDRYCB320
Premium
UO Control Kit
PREMTA000
PREMTA000A PEXPMB200 For Modbus PAHCNM000
PREMTA000B PDRYCB500 (Max. 3 Outdoor Units)
PEXPMB100 PAHCMW000
EEV Kit
(Electronic Expansion Valve)
014 / 015
ARCHITECTURE
CONTROL SYSTEM LG BECON HVAC SOLUTION offers a diverse range of effective control solutions that satisfy specific needs of each building
and its user scene. These control systems are equipped with user-friendly interface, flexible interlocking environment,
ARCHITECTURE energy management and smart individual controller for optimized controlling conditions and smart building management
Integrated Controller Central Controller Central Controller Power Distribution Indicator CONTROLLER FOR INDOOR UNIT
(Medium / Large) (Small)
PROPOSAL
CASE
AC Smart 5
PQCSZ250S0
Internet
PREMTB100
Motion
IO Module for
Sensor
Central Controller
PACS5A000
BACnet IP / Modbus TCP ACS IO Module
IO Module PDRYCB400
PREMTB001
Light
Thermostat
PEXPMB000
Pump
Fan PDRYCB300
Wireless R / C (For thermostat 3rd party
ACP LonWorks G / W
via contact signal) Home
Internet Controller
PEXPMB100
PEXPMB200 PI485
PEXPMB300 Etc
PLNWKB000
016 / 017
CONTENTS
LG BECON
HVAC
SOLUTION
INDIVIDUAL CONTROL
020 - 035
CENTRALIZED CONTROL
PROPOSAL
036 - 057
CASE
INTEGRATION DEVICE
058 - 094
PROPOSAL CASE
095 - 101
018 / 019
INDIVIDUAL CONTROL
INDIVIDUAL
CONTROL
FEATURE FUNCTIONS
Model Name
PREMTA000
PREMTB100 PREMTB001 PQRCVCL0QW PQRCHCA0QW PWLSSB21H (H / P)
PREMTA000A PWFMDD200
PREMTBB10 PREMTBB01 PQRCVCL0Q PQRCHCA0Q PWLSSB21C (C / O)
PREMTA000B
On / Off ○ ○ ○ ○ ○ ○ ○
Temperature Setting ○ ○ ○ ○ ○ ○ ○
Mode ○ ○ ○ ○ - ○ ○
Auto Swing ○ ○ ○ ○ ○ ○
Vane Control
○ ○ ○ ○ ○ ○ ○
(Louver Angle)
Basic E.S.P
○ ○ ○ ○ ○ - -
(External Static Pressure)
Electric Failure
○ ○ ○ ○ ○ - ○
Compensation
Schedule / Timer Weekly - Yearly Weekly - Yearly Weekly - - Sleep / On / Off Weekly
Time Display ○ ○ ○ - - ○ -
Humidity Display ○ ○ - - - - -
Advanced Lock
(Mode, Set point, Set point Advanced Lock Advanced Lock - - - - -
range, On / Off Lock)
Filter Sign ○ ○ ○ - - - -
Energy Management 2) ○ ○ ○ - - - -
Advanced
Dual Set Point ○ ○ - - - - -
Human Detection - ○ - - - - -
Temp, Humidity
○ ○ - - - - -
Compensation
INDIVIDUAL
ETC Display 5 inch Color 4.3 inch Color 4.3 inch mono 2.6 inch mono 2.6 inch mono 2 inch mono -
Size (W x H x D, mm) 137 x 121 x 16.5 120 x 120 x 16 120 x 120 x 16 64 x 120 x 15 64 x 120 x 15 51 x 153 x 26 -
020 / 021
STANDARD III STANDARD III
WIRED REMOTE CONTROLLER WIRED REMOTE
PREMTB100 (White), PREMTBB10 (Black)
NEW COMFORT
MODERN DESIGN & RELIABILITY
(Air Purify)
CONVENIENCE ENERGY
MANAGEMENT
SCHEDULE INTERLOCKING
STANDARD III
INDIVIDUAL
CONTROL
WIRED REMOTE CONTROLLER
STANDARD III
INDIVIDUAL
CONTROL
WIRED REMOTE CONTROLLER Features & Benefits
026 / 027
INDIVIDUAL CONTROL
PREMIUM
INDIVIDUAL
CONTROL
WIRED REMOTE CONTROLLER Features & Benefits
automatically
Cooling
- Setback (Leave Home) Changing status by occupied / Upper
* Supported languages list
Temperature
1) English / Portuguese / Spanish / French unoccupied limit
2) English / Italian / Russian / Chinese Setback
* This function is only for Heat Recovery system and Single heat pump.
3) English / German / Polish / Czech Auto Changeover
Lower
Temperature
Model Name PREMTA000 / PREMTA000A / PREMTA000B limit
Heating
On / Off ○
Fan Speed Control ○
Time
Temperature Setting ○ Arrive at Home Leave Home
Mode
Additional Mode Setting 1)
Cool / Heat / Dry / Fan / Auto
Energy-Saving Cooling / Robot Cleaning / Heater / Humidification
Group Control
Auto Swing ○
Vane Control (Louver direction) ○
- Max. 16 Indoor units by one remote controller
E.S.P (External Static Pressure) 2) ○
Reservation Simple / Sleep / On / Off / Weekly / Yearly / Holiday
Time Display ○
Indoor unit 1 Indoor unit 2 Indoor unit 3
Electric Failure Compensation ○
Child Lock ○
Master Slave Slave
Filter Sign ○ (Remain time + Alarm) 1 1
Check Energy Usage 3) / Check Operation Time / Target Setting (Energy, Operation Time)
Energy Management
/ Time Limit Operation / Alarm Popup / Initialization Usage Data
Red (12V)
Operation Status LED ○ Yellow (Sig)
Yellow (Sig) Yellow (Sig)
Black (GND) Black (GND)
Indoor Temperature Display ○ Black (GND)
028 / 029
INDIVIDUAL CONTROL
INDIVIDUAL
CONTROL
REMOTE CONTROLLER REMOTE CONTROLLER
030 / 031
INDIVIDUAL CONTROL
INDIVIDUAL
CONTROL
WI-FI MODEM
PWFMDD200
Installation Scene
Control box
Control panel
USB cable Wi-Fi modem
※ Search “LG ThinQ” on Google play or Appstore then download the app.
※ Internet service with Wi-Fi connection has to be available.
※ The Wi-Fi communication distance and reliability may be vary due to the type of Wi-Fi router and the installation environment, Please refer to the manual.
032 / 033
INDIVIDUAL CONTROL
INDIVIDUAL
CONTROL
WI-FI MODEM
4 LG ThinQ
3
2
1
Easy Management
Reservation Energy Monitoring Smart Diagnosis Filter Management
034 / 035
CENTRALIZED CONTROL
FEATURE FUNCTIONS
CENTRALIZED
CONTROL
Controller Name AC Ez AC Ez Touch AC Smart 5 6) ACP 5 6) ACP LonWorks AC Manager 5 7)
Model Name
CENTRALIZED
PC Access - ○ ○ 5) ○ 5) ○ 5) ○
CONTROL
3) Except for some feature (Individual lock, Limit temp., etc.)
4) Except for some feature (User mode, additional function, etc.)
5) This function is not applied for BMS points.
6) Without additional device, ACP 5 and AC Smart 5 provide BACnet IP and Modbus TCP interface for BMS.
7) ACP 5 or AC Smart 5 is required.
8) Hard Lock
036 / 037
CENTRALIZED CONTROL
AC EZ TOUCH
Features & Benefits
CENTRALIZED
CONTROL
PC Access
PC
Users can control each space efficiently through PC access.
IDU
...
Internet Internet
AC EZ TOUCH
IDU * IPv6 supported
...
- Fixed Public IP is recommended. If not, router’s configuration of NAT is required.
- Open port 80 & 9300
PACEZA000 Statistics of operational status (Time, Power consumption) When using energy mode function, operation Modes from
are provided to help make intelligent system operation cooling to fan or heating to off mode by force.
decisions. (It is available only for operating indoor unit)
Smart management with 5 inch touch screen for small site.
038 / 039
CENTRALIZED CONTROL
AC EZ TOUCH AC EZ
CENTRALIZED
CONTROL
Alarm Indicator
PQCSZ250S0
040 / 041
AC SMART 5
10” WITH HTML5 GUI
AC SMART 5 PACS5A000
Size (W x H x D, mm) : 253.2 x 167.7 x 28.9
TOUCH SCREEN
FOR EASY CONTROL
Lobby
Lobby
AC SMART 5
CENTRALIZED
CONTROL
PC SMARTPHONE TABLET PACS5A000
10-inch touch screen with HTML5 GUI (Graphic User Interface) for easy control.
BMS
INTERNET
AC SMART 5
AC SMART 5
Features & Benefits
CENTRALIZED
CONTROL
Air Purify Total Solution Energy Management
Air Purify Control The energy navigation function allows the air conditioner’s
Air Purify operational energy usage to be manged monthly, weekly
and yearly. By analyzing present energy consumption and
comparing with the plan, overuse of system operational
- Easy setting of Air Purify
costs can be prevented.
function (Set / Clear)
Good
* The Commercial Air purifier must additionally install PI485(PHNFP14A0).
System Air Conditioner Commercial Air Purifier
Building Management System (BMS) Integration
Visual navigation enables controlling and monitoring the unit User can make frequent and multi level group to control and (Air conditioner only → Sensors, Fans, Pumps, Switches…)
on floor plan view for the intuitive management. monitor the device easily. Air Water Hydro Kit IDUs
AC Smart 5 cooled cooled
Building West
West
Temp. CO2 Cooling Emergency
Floor #2 tower
Facilities
Occupancy
Faculty Valve Fan
...
Floor #1
Sensor
East Expansion
West Control Coverage
Floor #2
Temp. Lighting
ACS IO
046 / 047
CENTRALIZED CONTROL
ACP 5
CENTRALIZED
CONTROL
PC SMARTPHONE TABLET PACP5A000
Advanced solution for BMS integration up to 256 units via BACnet and Modbus protocol as well as
its own smart management function with web server interface.
BMS
Model Name PACP5A000
Size (W x H x D, mm) 270 x 155 x 65
INTERNET MULTI V / ERV / ERV DX / Hydro kit /
Interfaceable Products THERMA V / AHU Kit / LG Chiller 1) / Commercial Air Purifier
Maximum number of units 256
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Comfort Cooling / ODU Low Noise / ODU Defrost Mode / Comfort Level
Advanced Function Setting
ACP 5 and Display 2)
display / CO2 Level display (for ERV / ERV DX)
/ Night Time Free Cooling (for ERV / ERV DX)
Error Check ○
Schedule Weekly / Monthly / Yearly / Exception day
CH 5 ~ 6 CH1 ~ 4 Web Access ○
Emergency Stop & Alarm ○
Display
OR OR Power Consumption Monitoring ○
(with PDI)
Auto Changeover / Setback ○
AHU Chiller ACS IO Comm.Kit
rd Temperature Limit ○
Controller Option Kit 3 party interlocking
Operation Time Limit ○
AHU Chiller Facility IDU ERV Commercial Air AHU Visual Navigation ○
Purifier Operation Trend ○
Air Purify Control ○
Air Quality Level ○
Interlock Control ○
Centrifugal Cooling Tower Pump
Virtual Group Control ○
ODU Capacity Control ○
Energy Navigation (with PDI) ○
Daylight Saving Time ○
External IO Port DI 10 / DO 4
Absorption Valve Fan
BMS Integration 3) BACnet IP / Modbus TCP
IPv6 Support ○
Sensor
※ ○ : Applied, - : Not Applied
1) Chiller Option Kit (PCHLLN000) is required.
2) It is only available in some products.
Screw Motion Temp. CO2 3) For the detail point list, please refer to the installation manual.
Etc.
Integrated Management
The Commercial Air Purifier can be used with LG central controller to monitor and control.
Advanced Network Accessibility Energy Navigation BACnet IP & Modbus TCP Air Purify Control / Internet
Monitoring
BACnet over IP BMS
IPv6
ACP 5
Network
Commercial
HTML5 web design Air Purifier
Good
* Fix Public IP is mandatory.
* Router’s Configuration of NAT is mandatory. Open port 80 & 9300.
048 / 049
CENTRALIZED CONTROL
AC MANAGER 5
CENTRALIZED
CONTROL
PC SMARTPHONE TABLET PACM5A000
Multiple ACP and AC Smart integration solution to manage multi sites up to 8,192 units as
a single system.
INTERNET
AC MANAGER 5
Max.
or 32
ACP 5 AC SMART 5
Model Name PACM5A000
Size (W x H x D, mm) 270 x 155 x 65
Interfaceable Products MULTI V / ERV / ERV DX / Hydro kit / THERMA V / AHU Kit / LG Chiller 1) / Commercial Air Purifier
ODU / IDU & ERV Chiller & AHU 3 party Device
rd
Commercial Air Purifier
Maximum number of units 8,192 (Supports 32 ACP 5 or AC Smart 5)
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Chiller AHU Error Check ○
Option Kit Controller ACS IO Module
Schedule Weekly / Monthly / Yearly / Exception day
Web Access ○
Emergency Alarm Display ○
Power Consumption Monitoring (with PDI) ○
Centrifugal Cooling Tower Pump
Auto Changeover / Setback ○
Temperature Limit ○
Operation Time Limit ○
Absorption Valve Fan Visual Navigation ○
Operation Trend ○
Air Purify Control ○
Air Quality Level ○
Screw Motion Temp. CO2 Interlock Control ○
Virtual Group Control ○
ODU Capacity Control ○
AHU Energy Navigation (with PDI) ○
Comm.Kit
Invert Scroll Emergency Lighting
※ ○ : Applied, - : Not Applied
1) Chiller Option Kit (PCHLLN000) is required for ACP 5 or AC Smart 5.
Note : AC Manager 5 required for ACP 5 or AC Smart 5
Max.
AC Manager 5 Control tower AC Manager 5 32
ACP 5 ACP 5 AC Smart 5
050 / 051
CENTRALIZED CONTROL
AC MANAGER 5
Features & Benefits
CENTRALIZED
CONTROL
Up to 8,192 Connections for Indoor Units Advanced Network Accessibility & User Friendly GUI
Administrators can easily and conveniently manage a variety Max. IDU 256 EA As an advanced central controller, AC Manager 5 offers
of LG HVAC equipment. Also, it is available to manage many ... flexible interface for each user by assessing the device
buildings or areas at one place via AC Manager 5. screen and automatically customizing the layout to provide
Max. IDU 128 EA
the most optimized interface.
...
...
...
Max. IDU 256 EA
...
Smart Air Purify Solution Energy Navigation & Energy Usage Graph
Total management of air purify function creates clean environment for everyday. Energy navigation is the function to set the target usage
amount to limit the monthly power consumption and to
Air Quality Multi Status view Air Quality Summary Widget control so that the total accumulated power consumption
5
AIR PURIFIER_1C
AC_01
New
New
93
93
Good
Poor
Peak Control Multi Level Group Composition
6 AIR PURIFIER_1B New 92 Moderate
8 AIR PURIFIER_19 New 90 Moderate This function can reduce electricity use. There are two User can make frequent and multi level group to control and
9 AC_02 New 90 Poor
kinds of control logic. Energy saving effect by indoor unit monitor the device easily.
10 AIR PURIFIER_18 New 89 Moderate
11 AIR PURIFIER_17 New 88 Poor operation rate control. Load management effect by outdoor
unit capacity control.
Building West
Faculty
Robby Office VIP room Compressor Hz Control
Floor #1
West
- Daily (per hour), period (30 days) shows trends
Floor #2
- Excel output / easy to manage
052 / 053
CENTRALIZED CONTROL
CENTRALIZED
CONTROL
PLNWKB000 PI485 converts LG Air conditioners protocol to the RS485 protocol for the central controller.
• Power : C
onnected with the Indoor Units
• 1 for Each Indoor Unit
- Indoor Unit (ERV)
BMS system
CH5
CH1 ~ 4 Indoor unit : Max. 64 units (Air conditioner & Ventilation) / Indoor address : 00 ~ FF
* Master
1)
Internet
AC Smart 5
* Slave • MULTI V 5 • MULTI V • MULTI V S • MULTI SPLIT • ERV • AHU (Control Kit)
• MULTI V IV WATER IV • SINGLE SPLIT
• MULTI V III • MULTI V
Backup Operation • MULTI V II WATER II
1) Assignment of public IP address is required to access central controller through internet. Appropriate PI485 should be used according to PDB (Product Data Book).
054 / 055
CENTRALIZED CONTROL
CENTRALIZED
CONTROL
PMBUSB00A Modbus Gateway Memory Map
Baud Rate : 9,600 bps, Stop Bit : 1 stop bit, Parity : None Parity, Byte size : 8 bits
Providing Modbus RTU connection between LG Air conditioners and BMS. Coil Register (0 x 01)
Data Bit
No. Function Register
Features & Benefits Air Conditioner ERV / DX ERV Hydro Kit & THERMA V
• Function 1 Operate (On / Off) Operate (On / Off) Operate (On / Off) 0 : Stop / 1 : Run
- Modbus RTU communication with Modbus master controller 2 Auto Swing Aircon Operate (On / Off) Hot Water Mode (On / Off) 0 : Disable / 1 : Enable
3 Filter Alarm Release Filter Alarm Release 1) Reserved 0 : Normal / 1 : Alarm Release
- Modbus RTU slave (RS485) / 9,600 bps
4 Lock Remote Controller Lock Remote Controller Lock Remote Controller 0 : UnLock / 1 : Lock
- Applicable for MULTI V 5, MULTI V S, ERV, Heating 5 Lock Operate Mode Lock Operate Mode 1) Reserved 0 : UnLock / 1 : Lock Register = N X 16 + ①
- Size (W x H x D, mm) : 53.6 x 89.7 x 60.7 6 Lock Fan Speed Lock Fan Speed 1) Reserved 0 : UnLock / 1 : Lock (N = Indoor Unit Central Address)
- Max. 16 IDUs with single module / Max. 64 IDUs with 4 modules 7 Lock Target Temp. Lock Target Temp. 1) Reserved 0 : UnLock / 1 : Lock
8 Lock IDU Address Lock IDU Address 1) Reserved 0 : UnLock / 1 : Lock
- Power : DC 12V
9 Reserved Quick Ventilate Reserved 0 : Disable / 1 : Enable
10 Reserved Energy Save Reserved 0 : Disable / 1 : Enable
Modbus RS485 (LGAP 1)) 1) : This register value is applied ‘DX Ventilator’ ONLY.
2) : This value range can be between 0 ~ 127 [°C]. And it would be limited by upper & lower value according to the setting of remote controller.
056 / 057
INTEGRATION DEVICE
INTEGRATION
DEVICE
INTEGRATION
DEVICE
058 / 059
INDIVIDUAL
CONTROL
PDI PDI
(POWER DISTRIBUTION INDICATOR) (POWER DISTRIBUTION INDICATOR) PQNUD1S40 (Premium, 8 ports)
30 kWh PPWRDB000 (Standard, 2 ports)
C Shop
20 kWh Size (W x H x D, mm) : 270 x 155 x 65
PDI SHOWS DISTRIBUTED B Shop
POWER CONSUMPTION OF 30 kWh
A Shop
UP TO 128 INDOOR UNITS
CONNECT TO PULSE TYPE WHM
WHM
(Watt-Hour Meter)
PDI SHOWS
DISTRIBUTED POWER CONSUMPTION
OF UP TO 128 INDOOR UNITS.
INTEGRATION DEVICE
PDI
(POWER DISTRIBUTION INDICATOR)
INTEGRATION
30 kWh PDI shows distributed power consumption of up to 128 indoor units.
DEVICE
A Shop Pulse Line
ACS Central Controller
220 V ~
ACP 5
24 V ~
AC Manager 5 70kW
(00) ~ (03)
SELECT
Power Input PDI : AC 24V, Transformer : AC 220V
D Shop 160kW [00] [01] [02] [03]
※ ○ : Applied, - : Not Applied
ACP 5 50kW
[10] [11] [12] [13]
[ Slave 1]
[ Master ] [20] [21] [22] [23]
AC Smart 5 ACP
Note : 1. Power cable and type could be different from this scene depending on the Outdoor unit’s specification.
2. Measured power consumption could be different between PDI and Watt meter.
3. Applicable Central Controller : ACP 5, ACP LonWorks, AC Smart 5, AC Ez Touch
(Combination : we recommend to connect separated watt meter for Outdoor units to have correct power distribution value)
ACS IO MODULE
PEXPMB000
AC Manager 5 This module can be connected with ACP 5 or AC Smart 5 controller if additional I / O points
such as DI / DO and AI / AO for 3rd party devices control and monitoring are needed.
INTEGRATION
DEVICE
LG Central Control
ACP 5 AC Smart 5
ACS IO Module
Features & Benefits
LG SAC
• Interlocking with 3rd party equipment LG Central controller can make operation scenario with 3rd party equipment by ACS IO Module.
ODU • Control coverage is expanded. (Air conditioner only → Sensors, Fans, Pumps, Switches …)
※ DI : Digital Input, DO : Digital Output, UI : Universal Input, AO : Analog Output / Please contact our regional office to have connectable relay specification for analog output PT 1000 803Ω 1,573Ω
Analog Input Ni 1000 871.7Ω 1,675.2Ω
DC (Voltage) 0V 10V
Supply Fan
Boiler
064 / 065
INTEGRATION DEVICE
This module can be connected with ACP 5 or AC Smart 5 controller if additional I / O points LG central controller 5 series with Chiller Option Kit can provide LG chiller remote control
such as UIO / UI / UO for 3rd party devices control and monitoring are needed. and cycle monitoring.
INTEGRATION
DEVICE
ACU.UIO ACU.UO ACU.UI
• Chiller Option Kit installation of ACP, AC Smart should be Turbo Chiller Cycle information
Value Spec Min. Max. conducted by a specialized installation service engineer. View all Evaporator Compressor Condenser
Analog Input DC (Voltage) 0V 10V • Chiller Option Kit installation can be achieved with a SD Card.
Analog Output DC (Voltage) 0V 10V • The SD Card can install Chiller Option Kit in one ACP, AC
Binary Input
Digital Input (Non Voltage)
- - Smart. Insert the SD Card in the ACP, AC Smart.
Digital Output Normal Open - 30VDC, 1A If a backup SD Card is inserted, replace it with a Chiller
※ ○ : Applied, - : Not Applied Option Kit SD Card.
1) 1 ch is reserved for internal communication.
2) The type of UI (Universal Input) is selectable among Digital Input and Analog Input. Mode COOL Evaporator water out temperature 30.3 °C
Evaporator
066 / 067
INTEGRATION DEVICE
DRY CONTACT
PDRYCB000 PDRYCB500
INTEGRATION
Modbus RTU Communication
Dry Contact
DEVICE
(Contact point linked with 3rd Party)
...
Master
...
Interlocking Device
Contact Point Input
Max. 16 Indoor units per one
Modbus master controller
Indoor Unit
Operation On / Off PCB
Indoor Unit One to one connection between
Status
PCB dry contact and indoor unit
Error Alarm Key Lighting Fire Alarm Timer Motion Door Check CN - CC Indoor Unit
CN - CC Switch Sensor Detect Sensor Sensor
※ Please contact our regional office to check the compatibility with 3rd party room controller.
Specification
Connection between an indoor unit and external devices to control various functions.
PDRYCB400
Model Name PDRYCB000 PDRYCB400 PDRYCB300 PDRYCB320* PDRYCB500
Window Sensor
Case ○ ○ ○ ○ ○
Input Port 1 2 8 8 -
Card key Universal Input port - - - 1 -
Contact Point Input 1
Comm. Protocol - - - - Modbus RTU
Contact Point Input 2 Refrigerant Leakage Detection Alarm Power AC 220V Connect to Indoor unit PCB (CN_CC) : DC 12V
Indoor Unit
PCB Operation On / Off On / Off ○ ○ ○ ○ ○
Status
Operation Mode - ○ ○ ○ ○
Error Alarm
CN - CC Leakage Alarm
Set Temp. - (Select & Fix) (Select & Fix) (Select & Fix) ○
IDU Fan Speed - - ○ ○ ○
Thermo-Off - (Select & Fix) ○ ○ -
Card key Leakage Detector Energy Saving - (Select & Fix) - - -
Lock / Unlock - (Select & Fix) - - -
On / Off ○ - ○ ○ -
DHW On / Off - - ○ ○ -
Control
Thermo-Off - - ○ ○ -
Heating
PDRYCB300 / PDRYCB320* Operation Mode
Silent Mode
-
-
-
-
○
○
○
○
-
-
Emergency Mode - - ○ ○ -
On / Off ○ - - - ○
Dry Contact for Thermostat Operation Mode - - - - ○
ERV Aircon Mode - - - - ○
Additional Mode - - - - ○
Fan Speed - - - - ○
Operation Status ○ ○ ○ ○ ○
Output Error ○ ○ ○ ○ ○
Room Temp. - - - - ○
Target temperature setting* (0 ~ 10V)
Operation On / Off ※ ○ : Applied, - : Not Applied
Thermo On / Off Note : 1. Compatibility of PDRYCB300 / PDRYCB320 2. Compatibility of PDRYCB400
Indoor Unit Operation Mode (Fan / Heat / Cool) - Can use with all types of aircon indoor units after 2010. - Can use with all types of air conditioner indoor units after 2010.
PCB (Cassette, Ducted, Convertible, Applied PAC, Wall mounted, Console) (Cassette, Ducted, Convertible, Applied PAC, Wall mounted, Console)
Fan Speed (Low / Middle / High)
Room controller - Can use with new single package AK-W model after 2020. 1Q - Can use with new single package AK-W model after 2020. 1Q
Operation On / Off Status
CN - CC (The previous version Single package is not compatible) (The previous version Single package is not compatible)
Error Alarm
- Heating : 3 series AWHP split and Monobloc models - Can not use with AWHP, Hydro Kit models.
* Available only for PDRYCB320 ※ Please contact our regional office to have full compatible room controller list. 4 generation Hydro Kit 3. (Select & Fix) : This function is preset by rotary switch.
068 / 069
INTEGRATION DEVICE
REMOTE
GROUP CONTROL WIRE
TEMPERATURE SENSOR
PZCWRCG3 PQRSTA0
Cables used to connect a wired remote controller up to 16 indoor units. Sensor for detecting the room temperature.
INTEGRATION
DEVICE
2
1
Note : 1 Y type Cable assembly is for connecting indoor unit and long cable.
2 Long Cable assembly is for connecting indoor to indoor.
Extension Cable
CN-ROOM Connector
070 / 071
INTEGRATION DEVICE
ABZCA PVDSMN000
Controls air conditioning in up to 4 zones by external thermostat. Interface module between the outdoor unit of system air conditioner and the external device.
INTEGRATION
Features & Benefits Features
DEVICE
• Controls different zones (up to 4 zones) by external Function
thermostat (AC 24V) • Demand control
• Maintain proper air volume of each zone • Low noise operation
• Auto variation of dampers • Output outdoor or indoor unit operation status
• Auto control of fan speed and On / Off operation • Output error status
Description
• IO Module is communication interface module for connection between MULTI V 5 and external IO
(Input / Output Module) devices.
CN - ZONE
Thermostat Thermostat
072 / 073
INTEGRATION DEVICE
Provides variable settings for ODU Capacity Control according to input method to reduce the power consumption. Accessory for controlling the water flow.
IO Module supports 2 types of input signal : Analog Inputs (0 ~ 10V, 10 steps) and contact signals (3 steps)
INTEGRATION
Features
DEVICE
DDC
IO Module (Direct Digital Controller)
Function
Capacity
or Control with • Water pump or valve control (0 ~ 10V)
• Minimum output voltage setting available
Contact Signal
• Operation, error output (AC 250V, Max. 1A)
(3 Points / 3 Steps) • Dry contact input and analog output for demand control
MULTI V 5 MULTI V WATER IV
Range of Operation Rate • Digital output for operation, error status (AC 250V, Max. 1A)
AI 0 ~ 10V : 0%, 40% ~ 100%
Contact signal (3 steps) : 0%, 40% ~ 80%
Description
• Water flow consumption reduction
• Pump electricity consumption reduction
Low Noise Operation • Including IO Module (Dry contact input, Analog input / output, Digital output)
: Using Dry contact and variable water flow control function simultaneously.
To reduce noise level, control outdoor unit’s fan speed by dry contact input.
Cooling Tower
※ 8 HP (22.4kW) model, Sound power level can be changed by outdoor unit operation status and low noise operation input signal.
Inverter Pump
Cooling Tower
Pump / Cooling Tower
For safety, IO module closes refrigerant valve when Pump-down operation. Controller
Variable Water Flow Control Valve
Inverter Pump
⑥ Close Valve
Liquid Pipe Valve
MULTI V 5 Flow
③ Indoor Unit Stop Control
⑤ Outdoor Unit Stop Valve Pressure
& Pump-down
Sensor
④ Buzzer Alarm
Variable Water Flow Control Valve
Dry Contact
Remote Refrigerant
controller Detector ② Error Display ① Leak Detect
From Water Source
※ If the concentration of the refrigerant in the air exceeds 6,000 ppm more than 5 seconds, the function will be activated.
Inverter Pump
(Refer to operation sequence which written in red, 1~6)
074 / 075
INTEGRATION DEVICE
PRVC2 PRDSBM
External integration module for cooling operation with -25 °C low ambient temperature. Cooling only, heating only, and fan mode can be selected.
INTEGRATION
Features Features
DEVICE
• Indoor unit mode control without central controller.
Function
• Select operation mode : Cooling, Heating, Fan mode
• 25 °C Low ambient cooling operation by Low ambient kit and hood with damper
• Mode lock for cooling & heating mixing error-proof during the change of season.
(Analog output 0 ~ 10V)
• Demand control
• Low noise operation
• Output outdoor or indoor unit operation status (AC 250V, Max. 1A)
• Output error status (AC 250V, Max. 1A)
Models Applied
Description • MULTI V 5 • MULTI V WATER II • MULTI V WATER IV
• Low ambient kit supports -25 °C cooling operation by making stable condensing • MULTI V IV • MULTI V S
pressure with reducing air flow rate from hood and damper control given 0 ~ 10V • MULTI V WATER S • MUL TI V PLUS II, MULTI V PLUS
Models Applied proportional to condensing pressure.
• MULTI V 5 • Low ambient kit provides IO Module function.
• External snow hood and air damper are required for this item.
• Transformer and terminal block are included. Fan Mode Mode
AC 220V
Damper Damper
Transformer Actuator Actuator
MULTI V 5 Main PCB
Installation Scene
<Outdoor Main PCB >
Push Button
Terminal Block
• Connect Terminals (1, 2, GND) on the back side of the outdoor dry
DC 0 ~ 10V Insert wire method contact to terminals (1, 2, GND) of outdoor as shown below.
Control Signal
IO Module AC / DC 24V
Push arrow direction
Note
1. Damper Actuator can accept only DC 24V power input. Insert wire to
2. Do not input AC power. Otherwise it will cause a serious damage. • Communication line length can be maximum 300m, use
Field wiring connector
Communication line as thick 1.25mm.
3. The IO Module can control maximum three actuators. Connected wiring
4. Case of one valve, the slave signal connector must not use.
5. The power (AC / DC 24V) and signal (DC 0 ~ 10V) line is recommended by AWG22 (1/32 in, (0.644 mm), 0.016 Ω / ft (0.053 Ω / m)).
076 / 077
INTEGRATION DEVICE
AHU KIT
A solution to connect LG’s high efficiency system to the DX coil of an air handling unit for the Communication Kit
maximum energy savings.
INTEGRATION
LG's DX AHU solutions' superior performance provides a highly efficient heat source system.
DEVICE
• High energy efficiency inverter system
• Large range of expansion application Kit : Max. 168 kW EEV Kit 1)
• Connected to various heat sources : MULTI V, MULTI V WATER, MULTI V S, SINGLE SPLIT
1) Maximum connectable EEV capacity for PAHCMR000, PAHCMC000 is 112 kW.
PAHCMR000 PAHCMS000 PAHCNM000 PRLK048A0
PRLK096A0
CONTROLLER MODULE
PRLK396A0 MULTI V 5
PAHCMM000 PAHCMC000
AHU
+
Specifications
Control Application Kit Diverse Options for Control
Dimensions (mm) IP
Type Model Power Supply Description AHU communication kit can be connected to various control systems such as LG individual / central controller and DDC 1).
W H D Rating
It can be directly connected to DDC without separated controller, so DDC can receive product control and monitor
Return / Room air temperature control by DDC or LG
PAHCMR000 300 300 155 1Ø, 220 ~ 240 V, 50 / 60 Hz IP66
individual / centralized controller.
Communication information through contact signal or Modbus protocol.
Kit Discharge air / Supply air temperature control by DDC
PAHCMS000 380 300 155 1Ø, 220 ~ 240 V, 50 / 60 Hz IP66
or LG individual / centralized controller
PAHCMM000 162 90 61 DC 12V IP20 Main Controller module • LG Individual / Central controller supported LG Controller DDC by Contact Signal DDC by Modbus
Controller
Module - LG controller stand alone or combination with DDC
PAHCMC000 108 90 61 DC 12V IP20 Communication Controller module
• Direct wiring between DDC and
Various AHU control functions with multiple DX coils
Control Kit PAHCNM000 500 500 210 1Ø, 220 ~ 240 V, 50 / 60 Hz
(Maximum connectable ODU is 3 units) AHU communication kit Central Individual
Controller Controller DDC DDC
- Embedded Digital I / O and Analog Input
- Modbus RTU protocol supported AI / DI / DO
Expansion Application Kit signal
1) DDC : Direct Digital Controller
078 / 079
INTEGRATION DEVICE
AHU KIT
INTEGRATION
LG AHU system can be a suitable solution for various sites due to its application flexibility and wide range of line up with Single Split + Return / Room Air Temperature Control
DEVICE
large capacity models. According to the required capacity, a single or multiple module combination is possible due to the AHU
communication kit's modular design.
Temp. Sensors
• Multiple module combination for large capacity AHU Comm. Line
Central Comm. Line to ODU
Ref. Pipe
TE = Evaporator Temperature
(Liquid Pipe / Gas Pipe)
TR = Return Air Temperature
TROOM = Room Air Temperature
DDC
Control Option
TE
SINGLE SPLIT 1)
Centralized Controller
Discharge Air control Return Air control Return Air control Return Air control
AHU DX Coil
TR
OR / AND
ROOM
TROOM PAHCMR000
DDC
OR (Modbus or Contact signal 2))
PAHCMC000
080 / 081
INTEGRATION DEVICE
AHU KIT
Communication Kit & Controller Module Communication Kit & Controller Module
INTEGRATION
Single Split + Discharge Air Temperature Control MULTI V + EEV Kit + IDU + Return / Room Air Temperature Control
DEVICE
Temp. Sensors Temp. Sensors
Comm. Line Comm. Line
Central Comm. Line to ODU Central Comm. Line to ODU
Ref. Pipe Ref. Pipe
EEV Kit 1)
Control Option
TE
SINGLE SPLIT 1)
TD Centralized Controller
Control Option
AHU DX Coil TE
MULTI V
Centralized Controller
AHU DX Coil
OR / AND
TR
ROOM
OR / AND
PAHCMS000 ROOM
TROOM DDC
OR (Modbus or Contact signal 2))
+
TROOM PAHCMR000
PAHCMM000 PAHCMC000 DDC
(Modbus or Contact signal 2))
OR
1) PI485 (PMNFP14A1) is required for centralized controller.
2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC.
Note : For more detail, please refer to the PDB.
PAHCMC000
1) Multiple EEV kits can be applicable with multiple DX Coils and PAHCMR000s.
2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC.
Note : For more detail, please refer to the PDB.
082 / 083
INTEGRATION DEVICE
AHU KIT
INTEGRATION
PAHCMC000)
MULTI V + EEV Kit + Discharge Air Temperature Control Operation On / Off On / Off On / Off Digital Input (Non Voltage) -
DEVICE
Available operation mode can vary depending on
Operation Mode Cooling / Heating Cooling / Heating Digital Input (Non Voltage)
the settings of Communication Kit
Analog Input
Return (Room) Air Temperature 2) 16 ~ 30 °C - -
(DC 0 ~ 10 V / 20mA)
Temp. Sensors Discharge air temperature should be controller
Control 1) Discharge Air Temperature 2) - - -
Comm. Line directly by DDC using 'ODU Capacity Control
Central Comm. Line to ODU Fan Speed 3) - High / Middle / Low Digital Input (Non Voltage) -
Ref. Pipe Forced Thermal On / Off - Digital Input (Non Voltage) -
Comm. Line between modules Analog Input
ODU Capacity - 10 ~ 100% -
(DC 0 ~ 10 V / 20mA)
TE = Evaporator Temperature
Emergency Stop - Stop / Normal Digital Input (Non Voltage) -
(Liquid Pipe / Gas Pipe)
TD = Discharge Air Temperature Digital Output For PACHMR000, dip sw1-3 DO Type
Operation On / Off On / Off (Max. : DC 30 V / 1 A, should be set 'Off' (Status), In this case, '
TROOM = Room Air Temperature AC 250V / 1 A ) fan speed' cannot be monitored by DO ports
Operation Mode - - - It needs to be checked through control signal
Digital Output For PACHMR000, dip sw1-3 DO Type should be
MULTI V Fan Speed High / Middle / Low High / Middle / Low (Max. : DC 30 V / 1 A, set 'On' (Fan Mode) In this case, ‘On / Off, defrost,
AC 250V / 1 A ) error Status' cannot be monitored by DO ports
Monitor Digital Output
Defrost Operation Defrost / Normal Defrost / Normal (Max. : DC 30 V / 1 A,
EEV Kit 1) AC 250V / 1 A ) For PACHMR000, dip sw1-3 DO type
should be set 'OFF' (Status), In this case,
Digital Output, Relay C contact 'fan speed' cannot be monitored by DO ports
Error Alarm Error / Normal Error / Normal (Max. : DC 30 V / 1 A,
AC 250V / 1 A )
Digital Output,
Control Option Compressor On / Off - On / Off (Max. : DC 30 V / 1 A, -
TE AC 250V / 1 A )
1) Control functions for LG individual and central controller are not available in case of using together with DDC via contact signal.
TD Centralized Controller
2) The range of temp. is differ depending on the type of the controller.
3) To control fan speeds, DO port of the fan speed status should be connected to the fan control panel.
AHU DX Coil
Note : For more detail information, please refer to the product data book.
084 / 085
INTEGRATION DEVICE
AHU KIT
INTEGRATION
+ PAHCMC000) (2.5 ~ 5.0 kW) 1) (5.0 ~ 8.0 kW) 1) (7.1 ~ 10.0 kW) 1) (10.0 ~ 15.0 kW) 1)
Operation On / Off On / Off On / Off -
DEVICE
PAHCMR000
- ○ ○ ○
Available operation mode can vary depending on Communication Kit (PAHCMC000)
Operation Mode Cooling / Heating / Fan Cooling / Heating / Fan
the settings of Communication Kit (Controller Module) PAHCMS000
Return (Room) Air Temperature 2) 16 ~ 30 °C - - - ○ ○ ○
(PAHCMM000 + PAHCMC000)
Control 1)
Standard II : 16 ~ 30 °C
○ Control Kit PAHCNM000 - - - -
Discharge Air Temperature 2) - Standard III 4) : 12 ~ 50 °C
Central Controllers : 12 ~ 50 °C
1) When connecting to Single Split outdoor unit, please check the compatibility to the regional sales office.
To control the AHU fan, dip switch 1-3 'DO type'
Fan Speed 3) High / Mid / Low High / Mid / Low
should be set 'On (Fan Speed)' (PAHCMR000)
Operation On / Off On / Off -
Operation Mode Cooling / Heating / Fan Cooling / Heating / Fan -
Return (Room) Air Temperature ○ - - For Medium-Large Size Application (~ 672 kW) - MULTI V
Standard II : 11 ~ 39.5 °C
Discharge Air Temperature ○ Standard III 4) : 0 ~ 100.0 °C MULTI V MULTI V WATER
Monitor Central : -50.0 ~ 100.0 °C Type Model
5 Ⅳ Ⅲ S Ⅳ Ⅱ
Fan Speed High / Middle / Low High / Middle / Low -
Defrost Operation On / Off On / Off Only with Individual Controller PAHCMR000
○ ○ ○ ○ ○ ○
Communication Kit (PAHCMC000)
Error Alarm Error Code Error Code Error code will be displayed on the screen
(Controller Module) PAHCMS000
Compressor On / Off On / Off On / Off Only with Individual Controller ○ ○ ○ ○ ○ ○
(PAHCMM000 + PAHCMC000)
※ ○ : Applied, - : Not Applied Control Kit PAHCNM000 ○ ○ ○ ○ ○ ○
1) Control functions for LG individual and central controller are not available in case of using together with DDC via contact signal.
2) The range of setting temperature is different depending on the type of the controllers. And operation may different from setting range.
3) To control fan speeds, DO port of the fan speed status should be connected to the fan control panel.
4) Standard III wired remote controller after version 2.10.5a.
Note : For more detail information, please refer to the product data book.
086 / 087
INTEGRATION DEVICE
WATER COMMUNICATION
AHU KIT
MODULE
INTEGRATION
- Power : AC 24 V
- Output signal : DC 0 ~ 10 V
3rd party DDC or LG remote controller.
DEVICE
Temperature / Humidity Sensor Supply air duct, Return air duct, Outdoor air duct
- Temperature range : -40 °C ~ 70 °C
- Humidity range : 0 ~ 95 % RH
- Power : AC 24 V
Temperature Sensor - Output signal : DC 0 ~ 10 V Supply air duct, Return air duct, Mixed air duct
- Temperature range : -50 °C ~ 50 °C
- Power : AC 24 V
- Input / output signal : DC 0 ~ 10 V
Damper Actuator - Torque : 15 N·m Outdoor air damper, Exhaust air damper, Mixed damper
- Operation time : 150 s
- Rotation Angle : 90˚
- Power : AC 24 V
Overview
- Output signal : DC 0 ~ 10 V
Filter Differential Pressure Sensor - Range: 0 ~ 1,000 Pa Filter Interlocking with 3rd parties can make various solution with LG MULTI V outdoor unit.
- Switch type : Relay open / close
- Power : AC 24 V 1. EEV
Static Pressure Sensor - Output signal : DC 0 ~ 10 V Supply air duct
- Range : 0 ~ 1,000 Pa 2. Solenoid Valve (NC)
- Power : AC 24 V 3. Non-Return Valve
CO2 Sensor - Output signal : DC 0 ~ 10 V Return air duct
- Range : 0 ~ 2,000 ppm 4. FS : Flow Switch
- Power : AC 24 V 5. TT : DHW Temperature Transmitter
Smoke Detector Return air duct
- Type : Contact
CO2 Sensor 3 5
1 Water Side DHW
Refrigerant Side M TT
Smoke Detector Tank
2
Fan
- Supply / Return
Heat
Connection Pipe Exchanger
AHU HMI Communication Line
Thermistor (Pipe Temp.) • 3rd party solenoid, non-return valve, heat exchanger, flow switch and DHW temperature transmitter (Optional) must be purchased separately. (Field supplied items)
Signal (On / Off, DC 0~10V)
088 / 089
INTEGRATION DEVICE
WATER COMMUNICATION
MODULE
INTEGRATION
CH1 (A+ / B-) Module Comm. Port Communication Port Modbus
RS485
DEVICE
CH2 (A+ / B-) IDU Comm. Port Communication with MULTI V Outdoor
UI1 Flow Switch Flow Switch Input by 3rd party Water side
UNIVERSAL INPUT UI2 0 ~ 10V Set Temp. Target Temp. Setting
DHW On / Off Water Inlet (5m)
(Cooling / Heating Setting) UI3 Cooling Thermostat Signal Thermostat Cooling Signal
UI4 Heating Thermostat Signal Thermostat Heating Signal
3rd Party Water Outlet (5m)
UI1 Flow Switch Flow Switch Input by 3rd party Set Temp. (0 ~ 10V)
Controller
UNIVERSAL INPUT UI2 0-10V Set Temp. Target Temp. Setting
DHW Temperature Measured Water Temp. Input Error / Normal
(DHW Only) UI3 Dry Contact
Transmitter 0 ~ 10V by 3rd party 0 ~ 10 V sensor
UI4 DHW Thermostat Signal DHW Heating Signal (Option) Flow Switch (Field Supply)
Defrost /
RI1 Water Inlet Sensor PHEX Water Inlet Sensor LG Central Controller (Option) DHW Temp. Sensor
NTC Normal
RI2 Water Outlet Sensor PHEX Water Outlet Sensor (0 ~ 10V)
REMO +12V / SIG / GND LG Remote Controller -
SINGLE Reserved - - Filed Supply
DO1 Defrost / Mode Output for defrost signal and / or cool mode Standard III Remote
DIGITAL OUTPUT DO2 Pump Output signal for pump on / off Controller (Option) Ref. side
DO3 Bypass Output signal for PHEX Bypass Valve
LGAP
RI3 Thermistor Pipe In PHEX Ref. Inlet Pipe Sensor
NTC
RI4 Thermistor Pipe Out PHEX Ref. Outlet Pipe Sensor
EEV +12V / 1 / 2 / 3 / 4 Expansion Valve EEV Control
• The 3rd party can select the for best usable version Filed Supply
EEV kit
Solenoid valve for Bypass Flow switch
Capacity
• The nominal flow and cut of flow can be calculated using
Kv Value of
(kW) solenoid and the values below.
EEV type System Pipe size
Non-Return
Min. Max. Valve
Controller Nominal Flow Flow switch Cut off
PAEEVC000
3.6 28 HP / HR 0.95 3 / 8" / 9.52mm L / min*kW 3.29 1.23
PRLK048A0
28 56 PRLK096A0 HP 1.9 1 / 2" / 12.7mm * Example : ODU nominal Cooling Capacity 28 kW,
28 x 3.29 = 92.12 L / min. nominal flow,
28 x 1.23 = 34.44 L / min. flow switch cut off
090 / 091
INTEGRATION DEVICE
WATER COMMUNICATION
MODULE
Installation Scene with Contact Connection Installation Scene with Modbus / LG Control (Optional) Connection
Contact signal + Heating / Cooling Setting Modbus + DHW Only Setting
INTEGRATION
DEVICE
Water Side
Water Side
Pump
Heating On / Off Water Inlet (5m)
Cooling On / Off Modbus Water Outlet (5m)
3rd Party 3rd Party
Set Temp. (0 ~ 10V) Water Inlet (5m)
Controller Controller
Error / Normal Water Outlet (5m)
Dry Contact
Flow Switch (Field Supply)
(Option)
Defrost /
LG Central Controller (Option) LG Central Controller (Option) DHW Temp. Sensor
Normal Flow Switch (Field Supply) (0 ~ 10V)
Filed Supply
Standard III Remote Standard III Remote
Controller (Option) Controller (Option) Ref. Side
LGAP LGAP
Ref. Side
CH2 UI1 UI2 UI3 UI4 RI1 RI2 CH1 CH2 UI1 UI2 UI3 UI4 RI1 RI2
MULTI V MULTI V
CN-CC
DO1 DO2 DO3 RI3 RI4 EEV DO1 DO2 DO3 RI3 RI4 EEV
Pump On / Off
Pipe Out (5m) Pipe Out (5m)
092 / 093
INTEGRATION DEVICE PROPOSAL CASE
WATER COMMUNICATION
MODULE
INTEGRATION
DEVICE
Water Side
Pump
Ref. side
CH1 CH2 UI1 UI2 UI3 UI4 RI1 RI2
MULTI V
Pump On / Off
Pipe Out (5m)
Filed Supply
EEV kit
PROPOSAL
CASE
094 / 095
PROPOSAL CASE
PROPOSAL
CASE
Reception Atrium
Air conditioner control in conjunction Integrated management of AHU applied to large spaces
with check-in or check out
The air conditioner Integrated control of Control with existing Guest safety is Air conditioner control Proportionally distribute Fast problem detection Reduces energy Integrated Chiller and VRF
automatically turns off air conditioner with the hotel thermostat the first priority in conjunction with and manage power and alarms by checking management of AHU integrated control
when guests leave hotel room controller check-in or check out consumption by the tenant operational trends applied to large spaces
WHM
(Watt-Hour Meter) Chiller Option
Error C store
Pulse signal Kit (S / W)
Over
24 °C Cooling
21 °C
ACP 5
Power PDI
100 kWh
096 / 097
PROPOSAL CASE
PROPOSAL
Energy savings based on flexible Maintenance Office
CASE
scheduling
Integrated management of distributed buildings
Lobby
Centralized management of AHU for
Centralized management with multiple interfaces
large spaces
Proper airflow Monitor the comfort level External device Energy savings based on Centralized management Automatically save Central controls Schedule management Integrated management Centralized management
management for patients for each hospital ward interlock control flexible scheduling of AHU for large space energy in the absence prevent students from according to academic plan of distributed buildings with multiple interfaces
of students arbitrary control
Relay
• 4.3 inch color LCD • BMS Integration • BMS Integration • Discharge air • 4.3 inch color LCD
• Touch button (BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • Touch button
098 / 099
PROPOSAL CASE
OFFICE RESIDENTIAL
CONTROL SOLUTION CONTROL SOLUTION
Integrated management of HVAC with BMS system Integrate systems for smart connectivity throughout
PROPOSAL
Reasonable power distribution to
tenants
CASE
Simple interlocking control by remote control
Server Room
24-hour backup management
Apartment / Residence
Meeting Room
Energy savings based on occupancy Stable system operation
detection
Energy savings Integrated Reduce costs by Reasonable power Main equipment Energy savings Control your home air Build a Smart house Use a familiar residential Simple interlocking Stable system
and management management of HVAC replacing BMS distribution to tenants 24 hours back up based on occupancy conditioner anytime, thermostat control by remote control operation when indoor
throughout the building with BMS system management detection anywhere unit power is lost
WHM Human
BMS Protocol Pump Lighting Fan Sensor (Watt-Hour Meter) detection
Pulse signal sensor
Power PDI A B
Fan
BMS System 100 kWh
Forecasting
Radiator
PACS5A000 PLNWKB000 PEXPMB000 PPWRDB000 PACS5A000 PTVSMA0 PWFMDD200 PDRYCB500 PDRYCB300 PREMTB100 PRIP0
AC Smart 5 LonWorks gateway ACS IO Module PDI Standard (2 ports) AC Smart 5 Human detection sensor Wi-Fi modem Modbus RTU (9,600bps) PDRYCB320* Wired remote controller Independent power module
8 contact point
• BMS Integration • Max. 128 IDU • BMS Integration Function Function • 4.3 inch color LCD • EEV full close function
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • On / Off • Operation Input • Touch button
• Fan speed • Indoor temperature • Universal Input*
• Operation mode • Error alarm • Operation On / Off
• Vane control • Set operation mode • Thermo On / Off
• Reservation • Set temperature • Operation mode
(Sleep, Weekly On / Off) • Set fan speed (Fan / Heat / Cool)
• Error check • Fan speed
PACP5A000 PMBUSB00A PEXPM300 PQNUD1S40 PACP5A000 PREMTB100 (Low / Middle / High)
ACP 5 Modbus RTU gateway PEXPM200 PDI Premium (8 ports) ACP 5 Wired remote controller
PEXPM100 Output
• BMS Integration • Max. 128 IDU • BMS Integration • 4.3 inch color LCD • Operation On / Off status
ACU IO Module
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • Touch button • Error alarm
* Available from April 2020
100 / 101
CONTROL SYSTEM ARCHITECTURE STICKER
LG BECON HVAC SOLUTION offers a diverse range of effective control solutions that satisfy specific needs
CONTROL SYSTEM of each building and its user scene. These control systems are equipped with user-friendly interface, flexible
ARCHITECTURE
interlocking environment, energy management and smart individual controller for optimized controlling
conditions and smart building management
Integrated Controller Central Controller Central Controller Power Distribution Indicator CONTROLLER FOR INDOOR UNIT
(Medium / Large) (Small)
Individual Controller Dry Contact
AC Manager 5 ACP 5 AC Ez Touch PDI
Internet Internet Internet Wired R / C
PACM5A000 PACP5A000 PACEZA000
PDI Premium
BACnet IP / Modbus TCP PQNUD1S40 (8 Ports) Card Key
AC Ez
PREMTA000
PDI Standard
PPWRDB000 (2 Ports) PDRYCB000
AC Smart 5
PQCSZ250S0
Internet
PREMTB100
Motion
IO Module for Sensor
Central Controller
PACS5A000
ACS IO Module
BACnet IP / Modbus TCP
IO Module PDRYCB400
PREMTB001
Light
Thermostat
PEXPMB000
Pump
ACU IO Module PQRCVCL0QW(W)
PQRCHCL0QW(W)*
BMS Gateway PVDSMN000 * For Hotel
Fan PDRYCB300
Wireless R / C (For thermostat 3rd party
ACP LonWorks G / W
via contact signal) Home
Internet PEXPMB100 Controller
PEXPMB200 PI485
PEXPMB300 Etc
PLNWKB000
Controller for AHU
PWLSSB21H (Heat Pump) PDRYCB320
PWLSSB21C (Cooling Only) Dry contact for Thermostat
PMNFP14A1 Multi (For using universal input)
(For outdoor unit) Split
BMS
Building Protocol Modbus RTU G / W Wi-Fi Modem
Management AHU Comm.Kit AHU Control Kit
System
Single
AHU Comm.Kit AHU Control Kit Split
PMBUSB00A
PAHCMR000
(Return Air temp. control) PHNFP14A0 PDRYCB500
PAHCNM000 (For indoor unit) ERV (For thermostat
PWFMDD200
PAHCMS000 via Modbus RTU)
(Supply Air temp. control)
MEMO
PRODUCT LINE-UP STICKER
Individual Control
Standard III (White) Standard III (Black) Standard II (White) Standard II (Black) Simple
Centralized Control
스티커 용지 후면
Integration Device
Remote
Group
PDI ACS IO Module Temperature
Chiller Option Kit ACU IO Module Control Wire
(Power Distribution Indicator) (Input / Output Module) Sensor
Communication Kit Communication Kit Controller Module Controller Module EEV Kit
Return / Room Air control Discharge / Supply Air control Main module Communication module (Electronic Expansion Valve)