Volume Calculator

Select (x) Item Name

Sample Probe
Sample Probe with known tube OD and thickness
Known dimension
Length: 6.000000000 m
Tube OD: 10.000000000 mm
Tube wall: 1.000000000 mm

Calculated volume
Volume: 0.000000000 m3

x Sample Probe with known vol/length


Known dimension
Length: 0.000000000 m
Vol/Length: 46.000000000 cc/ft

Calculated volume
Volume: 0.000000000 m3

Sample Transportation
x Sample Transportation Line with known tube OD and thickness
Known dimension
Length: 19.000000000 m
Tube OD: 0.250000000 inch
Tube wall: 0.040000000 inch

Calculated volume
Volume: 0.000278092 m3

Sample Transportation Line with known vol/length


Known dimension
Length: 6.000000000 m
Vol/Length: 0.000150000 m3/m

Calculated volume
Volume: 0.000000000 m3

Sample Conditioning Tubes


Sample Tube with known tube OD and thickness
Known dimension
Length: 6.000000000 m
Tube OD: 10.000000000 mm
Tube wall: 1.000000000 mm

Calculated volume
Volume: 0.000000000 m3

Sample Tube with known vol/length


Known dimension
Length: 6.000000000 m
Vol/Length: 0.000150000 m3/m

Calculated volume
Volume: 0.000000000 m3

Sample Coalescing Filter


Sample Coalescing Filter (Cylinder)
Known dimension
Height/Length: 75.000000000 mm
Diameter: 60.000000000 mm

Calculated volume
Volume: 0.000000000 m3

Sample Gas Cooler


Sample Gas Cooler (Cylinder)
Known dimension
Height/Length: 75.000000000 mm
Diameter: 60.000000000 mm

Calculated volume
Volume: 0.000000000 m3

Sample Fine Mesh Filter


Sample Fine Mesh Filter (Cylinder)
Known dimension
Height/Length: 75.000000000 mm
Diameter: 60.000000000 mm

Calculated volume
Volume: 0.000000000 m3
Formula used:

𝑉=𝐴 ×𝑙 𝑉=𝑆𝑎𝑚𝑝𝑙𝑒 𝑣𝑜𝑙𝑢𝑚𝑒 (𝑚^3)


𝐴=𝑇𝑢𝑏𝑒 𝑎𝑟𝑒𝑎 (𝑚^2)
𝑉=(𝑉/𝑙) ×𝑙 𝑙=𝑇𝑢𝑏𝑒 𝑙𝑒𝑛𝑔𝑡ℎ (𝑚)
𝐼𝐷=𝑇𝑢𝑏𝑒 𝑖𝑛𝑠𝑖𝑑𝑒 𝑑𝑖𝑎𝑚𝑒𝑡𝑒𝑟 (𝑚)
𝑂𝐷=𝑇𝑢𝑏𝑒 𝑜𝑢𝑡𝑠𝑖𝑑𝑒 𝑑𝑖𝑎𝑚𝑒𝑡𝑒𝑟 (𝑚)
𝐴=𝜋×(𝐷/2)^2

𝐼𝐷=𝑂𝐷 −(2 ×𝑊𝑎𝑙𝑙 𝑇ℎ𝑖𝑐𝑘𝑛𝑒𝑠𝑠)


Weebz Mandiri
Indo Warehouse Blok C1
Jl. Kaliabang Tengah No. 22
System Flow Rate and Lag Time Bekasi Utara 17125 – Indonesia
SCS CEMS - MT - Pertamina telp/fax. +62.21.8838.0008

Pressure
Tubing Wall Additional Time Lag Time
No Item Volume (Nm3) Flow Rate (NL/min) ID (inch) Velocity (m/s) Process Pressure Atmospheric Pressure Order Lag
(inch) (s) (s)
(psia) (psia)
1 Sample Probe *) 0 4 0.000 0.000 0.000 15.7 14.7 1 0 0
2 Sample Transportation **) 0.00027809202446 4 0.500 0.049 0.815 157.7 14.7 1 0 44.7492196
3 Sample Conditioning Tubing *) 0 4 0.250 0.062 8.291 15.7 14.7 1 0 0
- To Fast Loop 0 0.5 0.250 0.062 1.036 15.7 14.7 1 0 0
- To Analyzer 0 3.5 0.250 0.062 7.255 15.7 14.7 1 0 0
4 Sample Coalescing Filter *) 0 4 0.000 0.000 0.000 15.7 14.7 1 0 0
5 Sample Gas Cooler *) 0 4 0.000 0.000 0.000 15.7 14.7 1 0 0
6 Sample Fine Mesh Filter *) 0 4 0.000 0.000 0.000 15.7 14.7 1 0 0

Note: Formula used:


*) volume is currently not available but it can be neglected compared to sample transportation volume 𝑡=𝑉/𝑄×𝑍 ×𝐹𝑖𝑟𝑠𝑡 𝑂𝑟𝑑𝑒𝑟 𝐿𝑎𝑔
**) sample transportation line's volume is calculated based on 15 meters 1/2" OD 0.0035" Thickness SS316 Tube

𝑡=𝐿𝑎𝑔 𝑡𝑖𝑚𝑒 (s)


𝑉=𝑆𝑎𝑚𝑝𝑙𝑒 𝑣𝑜𝑙𝑢𝑚𝑒 (𝑚^3)
𝑄=𝑆𝑎𝑚𝑝𝑙𝑒 𝑓𝑙𝑜𝑤 𝑟𝑎𝑡𝑒 (𝑚^3/𝑠)
𝑍=𝐶𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑖𝑏𝑖𝑙𝑖𝑡𝑦 𝐹𝑎𝑐𝑡𝑜𝑟 (𝑃/𝑃_𝐴 )
𝑃=𝑃𝑟𝑜𝑐𝑒𝑠𝑠 𝑎𝑡𝑚𝑜𝑠𝑝ℎ𝑒𝑟𝑖𝑐 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒
𝑃_𝐴=𝐴𝑡𝑚𝑜𝑠𝑝ℎ𝑒𝑟𝑖𝑐 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒

𝑣=𝑄/𝐴 𝐴=1/4×𝜋×(𝑂𝐷 −(2×𝑊𝑎𝑙𝑙 𝑇ℎ𝑖𝑐𝑘𝑛𝑒𝑠𝑠))^2

𝑣=𝑉𝑒𝑙𝑜𝑐𝑖𝑡𝑦 (m/𝑠)
𝐴=𝐶𝑟𝑜𝑠𝑠−𝑠𝑒𝑐𝑡𝑖𝑜𝑛𝑎𝑙 𝑎𝑟𝑒𝑎 (𝑚^2)
𝑂𝐷=Outside diameter (m)
Convertion
Vol/Length Unit Constant to m3/m Length Unit Convertion Constant to m
m3/m 1 m 1
cc/ft 3.28E-06 ft 0.304785126485827
inch 0.0254
mm 1.00E-03
Flow Rate
Pressure Unit Convertion Constant to psia Time Unit Convertion Constant to Unit
psia 1 s 1 m3/s
bar 0.0689464975179261 minute 60 m3/h
atm 14.6959 cc/min
l/h
l/min
Convertion Convertion
Constant first Constant first
unit Volume Unit unit
1 m3 1
0.000277777778 cc 1.00E-06
1.66666667E-08 l 0.001
2.78E-07 ft3 0.0283168
1.67E-05
Lag Time Calculator
1. Set tube spec and process spec
Length: 50.000000000 m
Tube OD: 8.000000000 mm
Tube wall: 1.000000000 mm
Process Pressure: 0.500000000 psia
Atmospheric Pressure: 15.000000000 psia
Flow Rate: 2.000000000 l/h

2. Calculation of Flow Rate


With known Tubing Spec
Q: 2628.1589747282 s = 43.80265 min
Formula used:

𝑡=𝑉/𝑄×𝑍=(𝐴 ×𝑙)/𝑄× 𝑃/𝑃_𝐴

𝐼𝐷=𝑂𝐷 −(2 ×𝑊𝑎𝑙𝑙 𝑇ℎ𝑖𝑐𝑘𝑛𝑒𝑠𝑠)

𝑡=𝐿𝑎𝑔 𝑡𝑖𝑚𝑒 (s)


𝑉=𝑆𝑎𝑚𝑝𝑙𝑒 𝑣𝑜𝑙𝑢𝑚𝑒 (𝑚^3)
𝑄=𝑆𝑎𝑚𝑝𝑙𝑒 𝑓𝑙𝑜𝑤 𝑟𝑎𝑡𝑒 (𝑚^3/𝑠)
𝐴=𝑇𝑢𝑏𝑒 𝑎𝑟𝑒𝑎 (𝑚^2)
𝑙=𝑇𝑢𝑏𝑒 𝑙𝑒𝑛𝑔𝑡ℎ (𝑚)
𝑃=𝑃𝑟𝑜𝑐𝑒𝑠𝑠 𝑎𝑡𝑚𝑜𝑠𝑝ℎ𝑒𝑟𝑖𝑐 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒
𝑃_𝐴=𝐴𝑡𝑚𝑜𝑠𝑝ℎ𝑒𝑟𝑖𝑐 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒
𝐼𝐷=𝑇𝑢𝑏𝑒 𝑖𝑛𝑠𝑖𝑑𝑒 𝑑𝑖𝑎𝑚𝑒𝑡𝑒𝑟 (𝑚)
𝑂𝐷=𝑇𝑢𝑏𝑒 𝑜𝑢𝑡𝑠𝑖𝑑𝑒 𝑑𝑖𝑎𝑚𝑒𝑡𝑒𝑟 (𝑚)