5

Insert the handle included in the erase lamp unit pack-


6

Hold the handle and lift it up, then pull out the erase
9

1. Close the cover for the erase lamp unit.
10

Close the front cover. Replaced the erase lamp unit
age into the upper and lower holes of the erase lamp lamp unit gently. 2. Tighten the screw underneath the cover for the will be tested.
unit. erase lamp unit.
3. Unlock the optical and erase parts.
Pull the blue knob up to unlock.

Hold the handle, with


Tapped hole, large
the mark  facing up. "Did you change lamp?" "Y:operation N:erase" message is
Fit the tapped hole (large)
displayed on the message display window. Push the "op-
to the blue screw and lift
eration" switch if replaced, "erase" switch if not replaced.
the erase lamp unit in the
direction indicated by
arrow 1 using the handle.

Immediately after the lamp has been


removed, the erase lamp unit is very hot. To
avoid burns, do not touch the lamp unit.

7
8

1. Tighten the upper screw fixing the erase lamp unit.
11

Insert the new erase lamp unit gently by using the Press the "operation" switch of the REGIUS MODEL
handle. 2. Tighten the lower screw fixing the erase lamp unit. 110.
3. Connect the connector underneath the blue cover
for the erase lamp unit.

operation erase

"operation" Switch Caution


Please contact Konica Minolta technical
"INITIALIZING" message is displayed on the message representatives on how to dispose the
display window. Upon completion of initialization, "READY" removed erase lamp unit.
will be shown and the REGIUS MODEL 110 is ready for
operation. 0902YC221A
Connect the connector
so that it clicks, turning 070525YM

Do not touch the yellow lamp of the erase the side with mark  
Manufacturer:
toward you.
lamp unit.
2970 Ishikawa-machi, Hachioji-shi Tokyo 192-8505 Japan