DESIGN CALCULATION OF DOC NO.

: PMW/DES/05
2 KL LIN STORAGE REV. NO. : 0
MANF SI. NO.: VS/ASME/03 DATE: 24 SEPTEMBER, 2021
LINDE INDIA LIMITED,PMW
Reinforcement Calculation for N1,N3,N4,N5 (for TOP D’END) as per UG-37
(Size 25 DN x 3.38mm Thk)
Fig. UG-37.1

P=Internal Design Pressure=0.68 MPa


d=Finished diameter of circular opening= (33.4-2 x 3.38)mm=26.67mm
tr=Required Thickness of seamless Head,( using E=1) (as per UG-32(f))
={(P x L)/ (2 x S x E - 0.2 x P)} (the 80% of the shell ID= (1030 x 0.8)mm=824mm,
so for all the nozzles (maximum nozzle offset from the centre of the D’End is 125mm)
are within the circle having the centre coinciding with the centre of the D’End and radius = (824/2)=412mm>125mm)
0.356 x L=(0.356 x 927)mm=330.012mm> t
0.665x Sv x E=(0.665 x 138 x1)MPa=91.77MPa>P
= {(0.68 x K1 x D)/(2 x 138 x 1 – 0.2 x 0.68)}mm (K1=0.9 as per Table UG-37)
={(0.68 x 0.9 x 1030)/275.864}mm
2.28504
=2.285mm
t=Specified D’end thickness=4mm
D= Shell ID=1030mm
tn=Nozzle wall nominal thickness (nominal)=3.38mm
trn=required thickness of seamless nozzle wall=0.099mm (ref page 17)
F= Correction factor that compensates for internal pressure stresses on different planes
with respect to the axis of a vessel. A value of 1.00 shall be used for nozzle attached to D’End.
E1=1 (for opening on the solid plate)
fr1=1 for nozzle wall abutting the vessel wall
Sn=Allowable stress in nozzle=115MPa
Sv=Allowable stress in Vessel=138MPa
fr2=Sn/Sv=0.833
A=total cross-sectional area of reinforcement required in the plane under consideration
= d x tr x F + 2 x tn x tr x F x(1-fr1)
= {(26.67 x 2.285 x 1) + 2 x 3.38 x 2.285 x 1 x (1-1)}mm2
=(60.941 + 0) mm2
=60.914mm2
A1=Area Available in D’End {Maximum of (i) & (ii)}
=d x(E1 x t - F x tr) - 2 x tn (E1 x t – F x tr)(1-fr1)

PAGE NO.: APPROVED BY


PREPARED BY
P. DUTTA S. RUDRA
Engineer-Design Head-Design