SHEETING

A B PURLIN-SHS-50x50

250
SHS-50x50x3.5
1632 B
SHS-150x150x5.7

1650
2
1

1650
2
1

8250
1632

1650
2
150 1500 150
3

CHEKERED
1650
PLATE
2 3 4 3

1500
3

1 1
1650

2
200 200

2
3.6 mm THK. 2
3.6 mm THK. COLUMN TOP PLATE
16 MM THK.
1520

2 50 NB PIPE
1
1520

COLUMN
1
2

7600
1520

50 NB PIPE
3
6 mm THK. 6 mm THK.
1520

SIDE ELEVATION
2

3
1632
1520

2 3.6 mm THK. 3.6 mm THK.

3 MEMBER DETAIL
1520

2
1
MEMBER MARK TYPE MEMBER SIZE
1520

2
1
1. CHANNEL FRONT
TO FRONT BOX ISMC 200 X150X7.5
7600

CHANNEL FRONT
1520

2 2. ISMC 200 X150X7.5


TO FRONT BOX

3
CHANNEL FRONT
LvL. + 500 3. ISMC 150 X150X5.7
1520

2 TO FRONT BOX
3
4. SQUARE
300 MM OD 6 MM THK. SHS 50X50X3.5
1
1520

2 PIPE COLUMN RUNNER PIPE


48600

7 NOS. 500

4 20 DIA BOLT
50 100
450

2 SIDE SECTION
5. SQUARE PIPE
SHS 50X50X3.5
1520

2
1
BP1 BASE PLATE
3.6 mm THK. 16 MM THK.
1520

1
2
16 MM THK.
BASE PLATE BP2 1632
2
7600

150 1500 150


1520

100 50
2
500 20 DIA BOLT
100 7 NOS.
PIPE COLUMN
3 1 300 MM OD 6 MM THK. 6 MM CHEKERED
1520

2
PLATE
3.6 mm THK. 3 4 3
3 DETAILS OF BP1 DETAILS OF BP2
1500
1520

5 1

200 200
1
1650

2
COLUMN TOP PLATE
2
16 MM THK. COLUMN

SECTION A-A
1650

2
1 1
8250
1650

2 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN METRES


UNLESS OTHERWISE SPECIFIED.
5 2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN
DIMENSIONS SHALL BE FOLLOWED.
1650

2
3. ALL SQUARE HOLLOW SECTIONS (SHS) SHALL BE YST 310 GRADE
2000

CONFORMING TO IS:4923-1997.
3 3 RALING PIPE 4. ALL CIRCULAR HOLLOW SECTIONS (CHS) SHALL BE YST 310 GRADE
3 3 3 3 3 CONFORMING TO IS:1161-1998.
5
1650

5. ALL STRUCTURAL STEEL PLATES AND ROLL SECTIONS SHALL BE


1000

2 CONFORMING TO IS 2062-2006.

6
6. THICKNESS OF GUSSET PLATES SHALL BE AS GIVEN BELOW:
a). VERTICAL GUSSET ON INNER FACE OF BOTTOM CHORD
(CONNECTING WITH FLOOR BEAM & OTHER MEMBERS) SHALL
1 2 1 2 1 2 1 2 1 2 1 16 mm THICK.
1650

2 b). ALL OTHER GUSSET PLATES SHALL BE 10 mm THICK.


8250 7. ALL WELDING SHALL CONFORM TO IS: 816-1969. ALL WELDS SHALL
BE SHOP WELDS EXCEPT THE WELDS AT FOLLOWING LOCATIONS:
COVERING LADDER ALL a). WELD OF BOTTOM/TOP BRACING CONNECTIONS.
1650

2 AROUND b). WELD OF FLOOR BEAM/TOP CROSS BEAM CONNECTION.


1 1
WITH PVC SHEET 8. ALL WELDS SHALL BE CONTINOUS FILLED WELDS (UNLESS
6000

NOTED OTHERWISE) AS PER THICKNESS GIVEN BELOW.


8250

a). WELD OF CAP PLATE WITH COLUMN & CAP PLATE STIFFNER
SHALL BE 10mm.
1650

2
1700 b). WELD OF BASE PLATE WITH COLUMN & BASE PLATE STIFFNER
SHALL BE 10mm.
TOOL BOOTH TOOL BOOTH
c). ALL OTHER WELDS SHALL BE 6mm.
1600

1600
9. ALL BOLTS AND NUTS SHALL CONFORM TO IS:1367(PART3):2002.
1650

175
2 10. ALL HOLES FOR BOLT SHALL BE D+1.5mm. WHERE D= DIAMETER
LvL. + 500 OF BOLT.
900 900
3 3 11. THE CONTACT SURFACE AT FOLLOWING LOCATION SHALL BE
MACHINED TO GIVE A PERFECT BEARING.
a). STEEL COLUMN AT BASE/CAP PLATE.
1650

2 b). STEEL TRUSS MEMBERS AT END PLATE (SPLICE LOCATIONS).


12. CUTTING LENGTH OF ALL MEMBERS AND GUSSETS TO BE
8250 7600 7600 7600 8250 FINALIZED BY FULL SCALE SHOP LAYOUT.
13. ALL DIMENSIONS TO BE CONFIRMED TO AT SITE BEFORE CUTTING
OF MEMBERS.
14. OPEN ENDS OF ALL HOLLOW SECTIONS SHALL BE SEALED WITH

B 6 5 SECTION B-B 4 3 2 1 6mm THICK WELDED PLATE.


15. ADDITIONAL BRACING/STIFFENERS MAY HAVE TO BE PROVIDED
PLAN OF FOB PATHWAY FOR MAINTAINING GEOMETRIC STABILITY DURING ERECTION/
CONSTRUCTION AS PER THE CHOSEN SCHEME OF ERECTION
THESE DETAIL SHALL BE INCLUDED IN THE FABRICATION
DRAWINGS TO BE PREPARED BY THE CONSTRUCTION AGENCY.
16. ALL HOLES NECESSARY FOR ERECTION BOLTS SHALL BE PLUGED
FULLY AFTER SUCCESSFUL COMPLETION OF ERECTION WORK.
17. FABRICATION AND ERECTION OF STRUCTURAL STEEL WORKS
SHALL CONFORM TO IS:7205-1974 &AND IS:7215-1974.

Rev. Date Description Authority: Epc Contractor: Authority engineer: proof Consultant: Design Consultant: Project: structural Consultant: Title:
PLAN AND ELEVATION OF TOLL PLAZA AT Km. 39+700
National Highways PNC Infratech Ltd. SA Infrastructure Consultants Pvt. Ltd. Holtec Consulting Pvt. Ltd. Transys Consulting Pvt. Ltd. PR INFRACON PVT.LTD.
Scale:
Koilwar- Bhojpur Section of NH-84 NOT TO SCALE Rev:
Authority of India 3/22-D, Civil Lines, Bypass Road JV A Block, Sushant Lok NM-8, Sona Tower, Old DLF Comm. Complex, Four Laninig of Koilwar to Bhojpur from Km 137.375 of NH-30 to Km
145/1, 4th Floor .
P.R. House Mangal Pandey Nagar
NH-2, (near Omaxe SRK mall) Gurgaon 122001, Haryana, India Sector-14, Gurgaon-122 001
(Ministry of Road Transport & Highways,
Agra - 282 002 VKS Infratech Management Pvt. Ltd. Ph: +91-124-4047900 Fax: 27.37 of NH-84 (Design Chainage Km 33.25 to Km 77.100) in the state Meerut -250001 R0
Government of India) of Bihar under NHDP Phase - III on EPC mode
+91-124-2385114,116 Email:-pristructure@gmail.com Date: 02- 03- 2022 Drg.No: PNC/NH-84/PKG-II/TP/002

You might also like