AC CONCENTRIC WINDING

WINDING DIAGRAM DIRECTION OF ROTATION OF GENERATOR

21 4

22 3

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Y

22 3

21 4

Y -Connection Delta - Connection

SR

SR FB

SR FB SY SB FR FY

FR

CALCULATIONS FB
FY SB
FR

24
Slots per pole per phase, spp =(4*3)
=2 SB
SY FY

Coil span = Pole Pitch = 24


4 =6
SY

1 Pole Pitch =>180o (electrical) => 6 slots


Slot angle = 180 o
6 = 30 (electrical)
Phase difference between start R & Y, Y & B = 120o
Number of coil groups = 24 4 =6 AC CONCENTRIC WINDING
WINDING TABLE (RYB PHASE SEQUENCE) KIRAN P
R : 1 2, 7 8, 13 14, 19 20 S5 EEE - A B180894EE SHEET NO. 4
Y : 5 6, 11 12, 17 18, 23 24 29 - 01 - 2021
B :9 10, 15 16, 21 22, 3 4