Revision code: R
M517- E429R
Revision Record
Revision Date Content
- Create first edition
Change the installation procedure by changing MPC.
Change the name of unit "PPWS" to "Side Station".
Change the port for the LAN cable of DAR-8000.
Add the description on the installation site for the data logger.
Add the note when the same segment is used in on-site
A 2006.08 network.
Change the procedure for connecting with Remote Desktop.
Change the procedure for DAR-8000 Network Settings.
Add "5-2-10 Setting of PC automatic start when power supply
returns."
Add "3 Preparation for Setup".
B 2007.03
Add "9 Special Operation".
C 2007.08 The remote maintenance supports the broadband.
D 2007.12 Revised according to the change of production system.
E 2009.05 Revised according to the change of MPC.
Change the Xcat setting in "9.3.3. Remote Maintenance Setting".
F 2010.04
Add "11 BBRM Upgrade Procedure".
J - -
M517- E429R
- Add "10.2 How to Upgrade BBRM to Version 3.0.1".
(Move the upgrading method to 2.3.0. to section 12.1.)
Changes the installation procedure of section 8.2.2. "Installing
and setting the UltraVNC in the DAR-8000" according to the
upgrade to UltraVNC1.0.9.6.2.
Correct the setting method in section 1.5 according to installed
OS.
Amendment of the following in accordance with the addition of
UPS made by OMRON.
"2. System Configuration"
Adding the cable (13) made by OMRON on "Table 1-1 Remote
Maintenance Cables and Connection Destinations".
"7.3. Connecting the UPS and MPC (DAR-8000f Only) "
Each connection of UPS made by APC and UPS made by
OMRON is indicated(7.3.1., 7.3.2.).
"8.1.2. Settings and Function of UPS control S/W(DAR-8000f
L 2013.11
Only) "
The title is changed.
Each UPS control SW of UPS made by APC and UPS made
by OMRON is indicated.
"8.1.3. Checking UPS Operation and Restarting the System
(DAR-8000f Only)"
Adding the check steps of UPS made by OMRON.
Clerical error correction, change of the termination parts of
manufacture
Description of UPS is divided to OMRON and APC.
“8.1. Setting and Checking Devices”
Description of temperature logger command is devided to for
M 2015-2
Air-cooling FPD and for Water-cooling FPD.
“10.1. How to Upgrade BBRM to Version 3.0.1”
Note is added. (for the sites BBRM isn’t installed yet)
UPS model change (BN220S to BN220T) and PCU model
change (PCU3 to PCU4)
“1.4 Network (Remote Maintenance) Model”
N 2015-2 Change diagrams.
"2. System Configuration"
Change diagrams, wiring and add LAN cable.
“5 Installing HUB”
M517- E429R
Add section.
“8.3.2 In the case of UPS made by OMRON”
Change photo.
“8.5.1 Connecting the MPC and the DAR-8000 Power
Transformer”
Change the connection destination of MPC power cable.
“8.5.2 Connecting Units to the Network”
Change wiring according to HUB added.
“9.1.2 Settings and Function of UPS control S/W(DAR-8000f
Only)”
Change settings for PCU4.
“9.1.3 Checking UPS Operation and Restarting the System
(DAR-8000f Only)”
Change checking contents and photo for PCU4.
“11.1.3 Install BBRM Version 3.0.1”
Modify UVNC setting.(checking “Allow Loopback Connections”)
Add caution to UPS operation and modify description of UVNC
settings.
“6 Network Setting”
Delete PCAnyware
“6.1. Remote Maintenance Settings”
Modify description.
P 2015-3 “9.1.3 Checking UPS Operation and Restarting the System
(DAR-8000f Only)”
Add caution to UPS operation.
“9.2.2. Installing and Setting the UltraVNC in the DAR-8000”
Modify UVNC settings.
“9.5.8. Installing and Setting the UltraVNC to the Side Station”
Modify UVNC settings.
Supported UD CONT-2002X board.
R 2015-4 “9.1.6. remolog UD Configuration” added.
“10.1.1. Operation in UD150B-40/L-40” revised.
M517- E429R
<This page is intentionally left blank.>
M517- E429R
CONTENTS
1 Introduction .........................................................................1
1.1. Tools Required for Installation .......................................................................................... 1
1.2. Checking the On-Site LAN Settings ................................................................................. 1
1.3. Overview of Installation Procedure ................................................................................... 2
1.4. Network (Remote Maintenance) Model ............................................................................ 3
1.5. Settings for Connecting with the Remote Center ............................................................. 4
2 System Configuration .........................................................8
3 Preparation for Setup .......................................................10
3.1. Add LAN Port (Only for DAR-8000i) ............................................................................... 10
4 MPC Setup ....................................................................... 11
4.1. Installing the Adapter Driver (DAR-8000f Only) ............................................................. 12
4.1.1. Installing of the Adapter Software ....................................................................... 13
4.1.2. Checking after Installation ................................................................................... 19
5 Installing HUB ...................................................................20
6 Network Setting ................................................................22
6.1. Remote Maintenance Settings ....................................................................................... 22
7 Connecting the MPC to X-ray High-Voltage Generator ....24
8 Connecting the Units ........................................................25
8.1. Connecting the Maintenance Cable to the X-ray Diagnostic Table ............................... 25
8.2. Connecting the RS-232C Cable to the X-ray High-Voltage Generator .......................... 26
8.3. Connecting the UPS and MPC (DAR-8000f Only) ......................................................... 27
8.3.1. In the case of UPS made by APC ....................................................................... 27
8.3.2. In the case of UPS made by OMRON ................................................................. 28
8.4. Connecting Room Temperature Gauges (DAR-8000f Only) ......................................... 29
8.5. Connecting Units to the MPC ......................................................................................... 33
8.5.1. Connecting the MPC and the DAR-8000 Power Transformer ............................ 35
8.5.2. Connecting Units to the Network ......................................................................... 37
9 Setting MPC and Checking Operations ............................38
9.1. Setting and Checking Devices........................................................................................ 38
9.1.1. Setting the Room Temperature Gauges and Check Its Operation (DAR-8000f
Only) 38
9.1.2. Settings and Function of UPS control S/W(DAR-8000f Only) ............................ 46
9.1.3. Checking UPS Operation and Restarting the System (DAR-8000f Only) .......... 63
9.1.4. Settings for Remote Maintenance Storage Server ............................................. 68
9.1.5. "Osiris" Installation ............................................................................................... 70
9.1.6. remolog UD Configuration ................................................................................... 70
9.1.7. BB Remote Maintenance Setting and Checking ................................................. 72
M517- E429R i
9.1.8. Checking the UltraVNC ........................................................................................73
9.2. DAR-8000 Settings ..........................................................................................................74
9.2.1. DAR-8000 Network Settings ................................................................................74
9.2.2. Installing and Setting the UltraVNC in the DAR-8000 ..........................................76
9.2.3. Installing the DAR-8000 Automatic Log Transfer Batch File ...............................83
9.2.4. Checking the Storage of DAR-8000 Data ............................................................85
9.3. PCU Settings (DAR-8000f Only) .....................................................................................86
9.3.1. PCU Settings ........................................................................................................86
9.3.2. PCU Network Settings ..........................................................................................93
9.3.3. Remote Maintenance Setting ...............................................................................95
9.4. Side Station Settings (Only Required If Side Station Is Used) .......................................96
9.4.1. Side Station Network Settings ..............................................................................96
9.4.2. Setting the Remote Desktop of the Side Station..................................................98
9.4.3. Installing the Automated log transfer batch file of Side Station ...........................99
9.4.4. Checking the Storage of Side Station Data ...................................................... 101
9.5. Side Station (Windows 7) Settings (Only Required If Side Station Is Used) ............... 102
9.5.1. Side Station (Windows 7) Network Setting ....................................................... 102
9.5.2. Setting the Remote Desktop of the Side Station............................................... 105
9.5.3. Setting the Power Options................................................................................. 107
9.5.4. Turning off the Internet time .............................................................................. 108
9.5.5. Turning off the Windows Auto Update .............................................................. 109
9.5.6. Turning off the Windows Firewall ...................................................................... 110
9.5.7. Turning off the System Restoration................................................................... 111
9.5.8. Installing and Setting the UltraVNC to the Side Station .................................... 112
9.6. Checking after Installation ............................................................................................ 118
10 Special Operation ........................................................... 119
10.1. Operation by TeraTerm .............................................................................................. 119
10.1.1. Operation in UD150B-40/L-40 ........................................................................... 119
10.1.2. Operation in SGIM ............................................................................................. 122
10.1.3. Operation in ZS-100 .......................................................................................... 124
10.2. How to Use Service Tools for BBRM-Agent............................................................... 126
10.2.1. Common Tool .................................................................................................... 126
10.2.2. BBRM Version 2.3.0 or earlier........................................................................... 128
10.2.3. BBRM Version 3.0.1 or Later ............................................................................ 135
11 BBRM Upgrade Procedure ............................................ 140
11.1. How to Upgrade BBRM to Version 3.0.1.................................................................... 140
11.1.1. Confirm Serial Number and Proxy Connection Setting ..................................... 141
11.1.2. Uninstall the already installed version ............................................................... 142
ii M517- E429R
11.1.3. Install BBRM Version 3.0.1................................................................................ 143
11.1.4. Checking Version............................................................................................... 156
11.1.5. Error Window ..................................................................................................... 157
12 Update of PCU Error Monitoring Tool (Only DAR-8000f)
158
12.1. How to Update ............................................................................................................ 158
13 Appendix.........................................................................162
13.1. How to Upgrade BBRM to Version 2.3.0 .................................................................... 162
13.1.1. How to Upgrade ................................................................................................. 162
13.1.2. How to Check BBRM Version............................................................................ 165
13.1.3. Error Window ..................................................................................................... 166
iv M517- E429R
1 Introduction
This manual explains the carry-in, setup, and wiring procedures required to install the
DAR-8000 remote maintenance option. It also provides precautionary information related to
installation. In order to ensure trouble-free, efficient operation that complies with performance
specifications, read this manual carefully before installation.
This manual applies to "Rev 04.00.00" or later versions of the DAR-8000 software and
"DAR-8000 Remote Maintenance S/W Rev 03.00.04" or later.
The setup procedures in this manual may also include items previously set at the
factory prior to shipment.
When starting or re-starting DAR-8000, use [Shimadzu] for the login account name.
M517- E429R 1
1.3. Overview of Installation Procedure
1) Install the MPC and connect it to the power, and then make the additional settings.
2) Make the connections required for remote maintenance between the units.
3) Make the remote maintenance settings for the PCU (DAR-8000f only).
4) Make the remote maintenance settings for the DAR-8000.
5) Make the remote maintenance settings for the Side Station (if a Side Station is used).
6) Check operation.
2 M517- E429R
1.4. Network (Remote Maintenance) Model
Explanations given in this manual are based on the network model shown below.
1) ISDN Line
Hospital
Public Shimadzu MS
Network
ISDN Dialup Router Remote
Maintenance
Center
HUB
2) BB Line
Hospital
Public Shimadzu MS
Network
BB Modem Remote
BB Router Maintenance
Center
HUB
M517- E429R 3
1.5. Settings for Connecting with the Remote Center
In order to connect with the Remote Maintenance Center, input the following settings in the
DAR-8000, MPC, Side Station and PCU.
* For items on the reference pages, refer to the corresponding pages.
For items without reference pages, refer to the following information and enter the settings.
* In the "Corresponding Unit" columns, "Done" indicates setting is completed. "Yes" indicates setting
is required, "No" indicates setting is not required.
Reference
Corresponding Unit
Page
Description Setting Method
DAR-
PCU MPC SS
8000
Click [Start] and right-click
[Computer].
Set [Allow Remote Click [Properties] to display the
Assistance [System] window.
connections to this Click [Remote settings] to
computer] to OFF display the [System Properties]
and [Allow SS(Windo
window.
1 connections from Yes No Done Yes ws7):
computers running In the [Remote] tab, clear [Allow
Page 105
any version of Remote Assistance connections
Remote Desktop to this computer] check box and
(less secure)] to select [Allow connections from
ON. computers running any version
of Remote Desktop (less
secure)] check box.
Select [Control Panel] - [User
Account]. Select "Administrator"
for the account. Select "Make
may password" and enter
"Shimadzu".
(If another password has been
previously set, "Change my
password" is displayed.)
Enter the account * Caution
name If the PC setup fails, -
2 "Administrator" and Yes No Done No
the password
"Administrator" will disappear
"Shimadzu". from the display.
If a different account is then used to
install the software, the software will
need to be re-installed when the
user returns to "Administrator"
mode. Therefore, be sure to set up
the "Administrator" account before
installing software. If this setup
method is unclear, please contact
the remote maintenance center.
Select [Start] - [Run...] and enter
"control userpasswords2".
In the [User Accounts] window,
clear the [Users must enter a
user name and password to use PCU:
Page 86
Set for automatic this computer.]check box and DAR-
3 Yes Yes Done No
login at startup. click [Apply]. 8000: -
In the [Automatically Log On]
window, enter "Administrator"
into [User name], "Shimadzu"
into [Password] and [Confirm
Password].
4 M517- E429R
Reference
Corresponding Unit
Page
Description Setting Method
DAR-
PCU MPC SS
8000
Select [Start] - [Control Panel]. In
the [All Control Panel Items]
Set [Never] as window, click [Power Options].
[Turn off the In the [Power Options] window,
SS(Windo
display] and [Put click [High performance] and
4 Yes Yes Done Yes ws7):
the computer to then click [Change plan settings].
Page 107
sleep] in [Power In the [Edit Plan Settings]
Options]. window, set [Never] as [Turn off
the display] and [Put the
computer to sleep].
Click [Start] - [Control Panel]. In
the [All Control Panel Items]
window, click [Date and Time].
In the [Internet Time] tab of the SS(Windo
Set the Internet
5
clock to OFF.
[Date and Time] window, click Yes No Done Yes ws7):
[Change settings... ]. In the Page 108
[Internet Time settings] window,
clear the [Synchronize with an
Internet time server] check box.
PCU
Click [Start] - [Control
Panel]-[Security Center].
In the [Windows Security Center]
window, click [Automatic
Updates]. In the [Automatic
Updates] window, click [Turn off
Automatic Updates.]. PCU:
Page 78
Set the Windows
6 Automatic Update SS Yes No Done Yes SS(Windo
to OFF. Select [Start] - [Control Panel]. In ws7):
the [All Control Panel Items] Page 108
window, click [Windows
Update]. In the [Windows
Update] window, click [Change
settings]. In the [Change
settings] window, select [Never
check for updates] as [Important
updates].
PCU
Click [Start] - [Control
Panel]-[Security Center]. In the
[Windows Security Center]
window, click [Windows Firewall].
Click the [General] tab and
select [Off (not recommended)]. PCU:
Page 78
Set the Windows SS
7 Yes No Done Yes
Firewall to OFF. Select [Start] - [Control Panel]. SS(Windo
In the [All Control Panel Items] ws7):
window, click [Windows Firewall]. Page 110
In the [Windows Firewall]
window, click [Change
notification settings]. In the
[Customize Settings] window,
click [Turn off Windows
Firewall].
M517- E429R 5
Reference
Corresponding Unit
Page
Description Setting Method
DAR-
PCU MPC SS
8000
Click [Start] and right-click
[Computer]. Then click
[Properties] to display the
[System] window.
Click [System protection] to
SS(Windo
Disable the system display [System Properties]
8 Yes No Done Yes ws7):
recovery feature window.
Page 111
Click [OS (C:)] as [Protection
settings] and then [Configure...].
In the [System Protection for OS
(C:)], click [Turn off system
protection].
Click [Control Panel]-[System].
Click [Advanced] tab and click
Set the display of [Settings] of [Startup and
9 the list of operating Recovery]. No No Done No -
systems to OFF. Turn off [Time to display list of
operating system:] of [System
startup].
DAR-8000
Double-click [My Network
Places] on the desktop, open the
"My Network Places" window,
and click [Network and Dial-up
Connections]. In the [Network
and Dial-up Connections]
window, double-click [Local Area
Connection] to display the [Local
Area Connection Status]
window.
Click [Properties] to display
[Local Area Connection
Properties] window. DAR-
Click [Internet Protocol (TCP/IP)] 8000:
and [Properties] to display
Make [Default [Internet Protocol (TCP/IP) Page 74
Gateway] empty. Properties] window.
(Except when using PCU:
10
Click [Use the following IP Yes Yes Done Yes Page 93
an on-site LAN's
local area
address] and make [Default
connection) gateway] empty. SS(Windo
ws7):
PCU Page 102
Click [Start] - [Control Panel] and
double-click [Network
Connections]. Double-click
[Local Area Connection].
- When connected to the
network: The [Local Area
Connection Status] window is
displayed. Click the [General] tab
and [Properties]. The [Local Area
Connection Properties] window
is displayed.
- When not connected to the
network: The [Local Area
Connection Properties] window
6 M517- E429R
Reference
Corresponding Unit
Page
Description Setting Method
DAR-
PCU MPC SS
8000
is displayed.
Click the [General] tab and
[Internet Protocol (TCP/IP)] -
[Properties] to display the
[Internet Protocol (TCP/IP)
Properties] window. Click [Use
the following IP address], and
make [Default gateway] empty.
SS
Select [Network address setting]
of the [Service Tools] menu .
Double-click [Local Area
Connection] in the [Network
Connections] window. In the
[Local Area Connection Status]
window, select [Properties]. In
the [Networking] tab of the [Local
Area Connection Properties]
window, click the [Internet
Protocol Version 4 (TCP/IPv4)]
and [Properties]. In the [Internet
Protocol Version 4 (TCP/IPv4)
Properties], click [Use the
following IP address] of and
make [Default gateway] empty.
At the American
Power Conversion
Corp. PowerChute Refer to 9.1.2. "Settings and
BusinessEdition
11 Function of UPS control No No Yes No Page 46
login, enter
"service" and S/W(DAR-8000f Only)".
"Shimadzu" for the
password.
Set the room
temperature
thermometer's Refer to step 8 in section 9.1.1.
measurement time
"Setting the Room Temperature
12 period to 30 No No Yes No Page 38
minutes. The Gauges and Check Its Operation
thermometer's time (DAR-8000f Only)".
is set in synch with
the PC.
M517- E429R 7
2 System Configuration
With reference to Figure 2-1 “Remote Maintenance Connections” and Table 2-1 "Remote
Maintenance Cables and Connection Destinations", connect the MPC, the router, the hub, and
all the other units.
Refer to 7 "Connecting the MPC to X-ray High-Voltage Generator", 8 "Connecting the Units"
and 8.5.1. "Connecting the MPC and the DAR-8000 Power Transformer" for details.
*1 Prepare a Router, HUB, or an ISDN and BB line at the site. (They are indicated by dotted line in
the figure below.) (Four LAN ports of the ISDN/BB router is available as the HUB.)
*2 This gauge is required for the Water-cooling FPD.
*2
(4) (5)
(7) *1
(16)
(6) (13)
COM4
(16)
(4) (5) USB2
USB1 ON board
(10)
COM3 (17) ISDN/BB Router ISDN
COM2 BB modem BB
appropriate device
COM1 GND or others
(8)
(9)
DAR-8000
Control cabinet
8 M517- E429R
Table 2-1 Remote Maintenance Cables and Connection Destinations
MPC,
(1) 088-81104-92 CABLE, LD-CT/BU30 30 m HUB
ONboard LAN port
DAR-8000,
(2) 088-81104-87 CABLE, LD-CTT/BU10/RS 10 m HUB
ONboard LAN port
Room
CONNECTOR,
(3) 088-50674-01 CABLE, AOM6S-20 20 m temperature
MODULAR PMJ-6
gauge
CONNECTOR, MODULAR
(4) 070-08127-01
PMJ-6
MPC, Expansion
(6) 511-15196-10 CABLE A, 09-2A-10M-2D 10 m
serial port 4
PCU,
(15) 088-81104-87 CABLE, LD-CTT/BU10/RS 10 m HUB
ONboard LAN port
ISDN/BB
(17) 088-81104-87 LD-CTT/BU10/RS 10 m HUB
Router
[ ]: Option
*1 This cable is used by alternative by UPS to be used.
The case of UPS made by APC is indicated on the uppwer row, and the case of UPS made
by OMRON is indicated in the lower row.
M517- E429R 9
3 Preparation for Setup
There are two type of DAR-8000i; one type has one LAN port and another type has two LAN
ports. The number of LAN port of DAR-8000i depends on the shipment time.
If there is only one LAN port, install an expansion LAN card to PC inside the DAR-8000 cabinet.
Refer to Appendix F "Installing the LAN Card" in "M517-E380 DAR-8000i Installation Manual
(Rev.B or later)" to check the number of LAN port and install it when the LAN port is only one.
10 M517- E429R
4 MPC Setup
In order to set up the MPC alone, use the attached power cable.
The power requirement of the MPC is AC 100V. Make sure that the power source is
AC 100V before connection. If you connect the MPC to other than AC 100V, the MPC
will be damaged.
The attached power cable is not used after the completion of this setup. Disconnect
and keep the cable.
Check that the main switch on the back of the MPC is tuned OFF (0), and connect the MPC to a
commercial power source in the hospital (AC100V).
A display, keyboard, and mouse are not included in the standard equipment.
Connect those of the DAR-8000 to the MPC temporarily to perform settings described below.
This section descries the setup of the adapter driver.
M517- E429R 11
4.1. Installing the Adapter Driver (DAR-8000f Only)
Install additional software after connecting the adapter. Install the driver and software using the
procedures described below. If the USB port to which the adapter is connected is changed after
installation of the driver and software, the software must be installed again. Use the USB port 1 or
2 indicated in the figure below.
USB Port 1
USB Port 2
12 M517- E429R
4.1.1. Installing of the Adapter Software
In cases where the window does not appear, and the COM number is already displayed,
correlation with the driver has been completed normally. Therefore this section is not needed.
Go to the section 5 "Installing HUB
Install the HUB (088-80110-01 HUB, ES1008MTP) in the PSU rack as shown below:
The HUB is magnetic-backed.
M517- E429R 13
14 M517- E429R
The HUB’s power cable is connected to UPS as follows.
M517- E429R 15
Network Setting".
Check the following items, in cases where the window of Step 1 in the next page is
not displayed.
1. Check whether the adapter is attached to MPC.
2. Click [Start]-[Control panel]-[System]-[hardware] Tab. Click [Device
manager]-[Ports (COM&LPT)] to display the list of the COM ports.
16 M517- E429R
- Connecting "BSUSRC0610BS" (088-50892-73) to USB Port 1
M517- E429R 17
- Connecting "BSUSRC0610BS" (088-50892-73) to USB Port 2 (for Water Cooling FPD)
18 M517- E429R
4.1.2. Checking after Installation
Check that the driver and software for the adapter have been installed properly.
1 Click [Start].
2 Right-click [My Computer] on the
Start menu, and click [Properties].
The [System Properties] window is
displayed.
3 Click the [Hardware] tab and click
[Device Manager]. The window on
the left is displayed.
4 Double-click [Ports (COM & LPT)]
and check that the item shown
below is displayed.
"USB Serial Port (COM5)"
"USB Serial Port (COM6)"
*The Air-cooling FPD has one
temperature-and-humidity logger, so
only one COM number is recognized.
*The COM number differs depending
on the environment.
5 After checking the display, close
the [Device Manager] window.
6 Shutdown MPC.
M517- E429R 19
5 Installing HUB
Install the HUB (088-80110-01 HUB, ES1008MTP) in the PSU rack as shown below:
The HUB is magnetic-backed.
20 M517- E429R
The HUB’s power cable is connected to UPS as follows.
To HUB
M517- E429R 21
6 Network Setting
Refer to section 9.2.1. "DAR-8000 Network Settings", 9.3.2. "PCU Network Settings", 9.4.1.
"Side Station Network Settings", 9.5.1. "Side Station (Windows 7) Network Setting" and the
Remote Maintenance Center manual for the router.
Table 6-1 Remote Maintenance Settings
Item Router MPC*1 PCU*2 DAR-8000 Side Station*3
ISDN - - - - -
Default
gateway (192.168.100.1)
BB
*4
ISDN - - - - -
Priority
DNS (192.168.100.1)
BB
*4
Windows XP or
Windows 2000 or
Windows XP Windows 7
OS - Windows XP Windows XP
English version English version
English version
*6
*1: MPC settings have been completed based on the settings in the table as standard.
*2: DAR-8000f only.
*3: Option
*4: It is need to be set to connect to the BB.
*5: Refer to the Remote Maintenance Center manual.
*6: It is Windows 7 English version when the Side Station is Revision. 03.00.00 or later.
22 M517- E429R
■ Connecting Two or More DAR-Units to the Same Network
Specify the last digits of the IP addresses as shown in the table below. Settings other than IP
addresses are the same as those shown in the table above. Even if two or more DAR-8000
units are installed, no more than one router is used in the same network. If the number of ports
on the router is insufficient, add hubs as appropriate and connect all units to the network.
Item Router MPC PCU*1 DAR-8000 Side Station*2
IP address:
192.168.100.1 192.168.100.10 192.168.100.11 192.168.100.13 192.168.100.14
first unit
IP address:
- 192.168.100.20 192.168.100.21 192.168.100.23 192.168.100.24
second unit
IP address:
- 192.168.100.30 192.168.100.31 192.168.100.33 192.168.100.34
third unit
■When the same segment has been used in the existing on-site network.
When the same segment (192.168.*.*) has been used in the existing on-site network, the said
IP address may not be available for the remote maintenance. In this case, ask the administrator
of the on-site network to assign a proper IP address.
■IP address setting for the software displaying the temperature warning. (Only for DAR-8000f)
IP address is set to the above described address as a default setting. In case that more than
two DAR-8000 are connected in the same network or the IP address is changed to the specified
address, please change the IP address setting in “C:\PCUErrSend\PCUErrorSend.ini “ on MPC.
"PcuErrorSend.ini"
[Network]
IP=192.168.100.13 Change the IP address.
PORT=3000
M517- E429R 23
7 Connecting the MPC to X-ray High-Voltage Generator
Top cover
Eyebolt 1 Remove the two eyebolts and then
remove the top cover from the X-ray
high-voltage generator's control
cabinet.
Legs
Spikey hooks
(P/N: 502-25866)
PC mounting board
(P/N: 502-23936)
24 M517- E429R
8 Connecting the Units
Connect the MPC and each unit by following section 2 "System Configuration" and 8.5.
"Connecting Units to the MPC".
Maintenance cable
M517- E429R 25
8.2. Connecting the RS-232C Cable to the X-ray High-Voltage Generator
Connect the RS-232C cable to the X-ray high-voltage generator's control cabinet. Refer to 8.5.
"Connecting Units to the MPC" for details on connecting to the MPC.
RS-232C cable
UDCONT-2002
SGIM board
26 M517- E429R
8.3. Connecting the UPS and MPC (DAR-8000f Only)
8.3.1. In the case of UPS made by APC
Attach an expansion board (made by APC) to the UPS and connect the MPC connection cable.
Interface cable
M517- E429R 27
8.3.2. In the case of UPS made by OMRON
Attach an expansion board (made by OMRON) to the UPS and connect the MPC connection cable.
Spacers The attached cable of UPS 1 Attach two "SPACER, SBA-305(E)"
(Maker P/N: BUC26)
((7) ;037-38785-18) to the connector at
the male end of "CABLE A,
09-2A-10M-2D" ((6) ;511-15196-10).
Cable A, 09-2A-10M-2D, male end
2 Connect " The attached cable of
UPS"(Maker’s P/N:BUC26) to the male
end of "CABLE A, 09-2A-10M-2D"
((6) ;511-15196-10).
28 M517- E429R
8.4. Connecting Room Temperature Gauges (DAR-8000f Only)
Set up TH-101 room temperature gauges (made by Microtechno Corporation) and set them to
record data every 30 minutes.
■ Names and Functions of Parts
1 Power Switch
This is the TH-101 room temperature gauge's power switch. The knob of the switch is inside a
window on the side of the case. Slide it with the tip of a ballpoint pen or some other appropriate
implement.
2 Record Switch
Used as the execution switch for each mode.
3 Interval Switch
Used to change parameters for each mode.
4 Mode Switch
Used to switch between TH-101 modes.
5 COM Connector
Used to connect to the PC. Connect it with the cable provided and set times, measurement
conditions or retrieve data as necessary.
6 Alarm Output
If any two parameters out of the temperature, the humidity, or the dew point become equal to
previously set upper or lower limits, a contact turns ON, and an alarm is output.
7 LCD
Indicates the temperature and humidity. It also indicates the status of data recording, displays
messages indicating that, for example, the battery is being replaced or that measurement is in
progress, and indicates alarms (upper/lower limit).
8 Sensor
Incorporates temperature and humidity sensors.
M517- E429R 29
■ Connection and Setup
3 Insert batteries.
a. Remove the battery cover on the back of the
gauge by sliding it in the direction indicated by
the arrow.
b. Insert AAA alkaline batteries as shown on the
right. Be sure to insert the batteries with the
correct orientation. The orientation is the same
for both batteries.
c. Attach the battery cover.
1
* COM6 is connected only for the Water-cooling
FPD.
30 M517- E429R
7 Place this gauge in an appropriate location.
Set one unit around the FPD.
Set the another unit around the Water Cooler unit
for the Water Cooling FPD.
Secure the gauge with Velcro attached to the
position arrowed as shown on the right.
When installing a room temperature gauge near
the FPD, be sure it is installed at approximately
the same height.
Run the cable so that it does not interfere with
examinations.
The service life of the batteries is approximately 3 months. When the batteries near the end
of their service life, a battery symbol is displayed in the gauge's LCD. Replace both AAA
alkaline batteries with reference to the procedure described in "Connection and Setup".
The Air-cooling FPD has 1 gauge and the Water-cooling FPD has 2 gauges.
M517- E429R 31
■ Installation Site(For around the FPD)
The data logger installed for around FPD is installed near the pole of ZS-100 as shown below to
measure the temperature around the ZS-100.
Pole of ZS-100
The another data logger installed for around the cooling unit is installed on the cooling unit
inside the sub cabinet as shown below to measure the temperature around the cooling unit.
32 M517- E429R
8.5. Connecting Units to the MPC
Connect the serial port and USB port of MPC to each device. The connectors correspond to
each port as follows:
MPC Connected to
COM1 UD CONT-2002 board in X-ray high-voltage generator’s control cabinet
COM2 SGIM board in X-ray high-voltage generator’s control cabinet
COM3 NEX SH board in X-ray diagnostic table’s control cabinet
COM4 UPS
USB Port 1 (COM5) Room temperature gauge for vicinity of FPD Unit
USB Port 2 (COM6) Room temperature gauge for vicinity of Water Cooler Unit
M517- E429R 33
To SGIM board in X-ray high-voltage To X-ray diagnostic table’s 3 Connect UD CONT-2002
generator’s control cabinet control cabinet board in X-ray high-voltage
UPS generator's control cabinet
To UD CONT-2002 board for X-ray
high-voltage generator’s control cabinet and onboard COM1 port of
MPC with "CABLE,
RS232C-09FEMALE-5M"
((8) ;070-02160-19).
*Refer to 8.2. "Connecting the
RS-232C Cable to the X-ray
High-Voltage Generator" for
details.
4 Connect SGIM board in X-ray
high-voltage generator’s
control cabinet and onboard
COM2 port of MPC with
"CABLE,
RS232C-09FEMALE-5M"
((9) ;070-02160-19).
*Refer to 8.2. "Connecting the
RS-232C Cable to the X-ray
High-Voltage Generator" for
details.
5 Connect NEX SH board in
X-ray diagnostic table’s
control cabinet and onboard
COM3 port in MPC with
"Maintenance cable
"((10) ;502-24345-01). *Refer
to 8.1. "Connecting the
Maintenance Cable to the
X-ray Diagnostic Table" for
details.
6 Connect UPS and onboard
COM4 port of MPC with
"CABLE A, 09-4A-10M-4D"
((6) ;070-02273-08).
*Refer to 8.3. "Connecting the
UPS and MPC (DAR-8000f
Only)" for details.
34 M517- E429R
8.5.1. Connecting the MPC and the DAR-8000 Power Transformer
This section describes how to connect MPC's AC power cable. Follow the procedure below
according to the UPS to be used.
- UPS by APC
With reference to the procedure described below, connect MPC's "AC power cable"
((11) ;502-24966-20) and "Ground cable, #10" ((12) ;502-24426-03) to the DAR-8000 power
transformer. The AC power cable's three terminals are respectively marked with the characters
"0V", "100V", and "G". Be sure to connect the cable correctly.
1. Be sure to check that the breaker of the power switchboard of the unit is
turned off to prevent electric shock.
2. Be sure to check that the breaker of each unit is turned off.
When it is tuned ON, be sure to turn it off before starting connection.
Check that the main switch on the back of the MPC is turned OFF (0). If it is turned ON,
be sure to turn it off before starting connection.
M517- E429R 35
3 Use any screw from the back of
MPC, and secure "Ground cable,
#10" ((12) ;502-24426-03) to
MPC.
1. After the power transformer ASSY installation, if the breaker of the power
switchboard of unit is turned off, the MPC does not work.
2. When the breaker of the power switchboard is turned off unavoidably, turn on
the MPC again to restart it.
Be sure to inform a customer about this note.
- UPS by OMRON
Connect MPC's power cable (511-15134 CORD SET, KP300CLS16FS) to the power socket on
the UPS as shown below:
36 M517- E429R
8.5.2. Connecting Units to the Network
When the connections between the units are completed, connect the Hub and the LAN ports of
the units and then connect the HUB and ISDN/BB router. Refer to the connection diagram in
section 2 "System Configuration".
The LAN ports of the units and the HUB are shown below:
MPC
② ③ ④
(for Maintenance) (for Maintenance)
LAN LAN
(Expansion Board) (Expansion Board)
(for DICOM) (for DICOM)
①
④ ③ ② ④ To router
へ
M517- E429R 37
9 Setting MPC and Checking Operations
Set devices and check the operation of them that connect to the MPC.
9.1.1. Setting the Room Temperature Gauges and Check Its Operation (DAR-8000f
Only)
Set the room temperature gauge near FPD unit, and if Water Cooler Unit is used, also set the
gauge near the unit.
1 Turn on the gauge's power switch.
2 Turn on MPC. The Windows starts.
38 M517- E429R
4 Select [Communication(C)] on the main
menu and then select [Serial port
setting(M)…]. The [Communication port]
window is displayed.
M517- E429R 39
7 Click the [Time] tab and input the
correct date and time. Select the [Adjust
to the PC time] check box. Click
[Setting].
40 M517- E429R
10 Click the [Dew point alarm] tab, make
the setting shown below, and click
[Setting].
Upper limit: No
11 When all the settings are completed,
click [Close]. The window closes.
M517- E429R 41
■ Checking Operation of the Room Temperature Gauges and Starting Recording
After checking the operation of the room temperature gauges, start recording. Perform this for
each instrument. With reference to "Setting the Room Temperature Gauges", select the COM
ports to which the gauges are connected.
1 Select [Communication] on the main
menu and then select [Realtime
indication]. The temperature and
humidity are indicated as graphs.
*The display interval setting is fixed at 2 sec.
*When the graphs reach the right-hand side,
they automatically shift to the left.
*Observe the temperature graph for a few
minutes to check that the correct
temperature is displayed, and then click
[Stop]. A dialog box is displayed to confirm
that the real-time display data is to be
↓
saved. Click [No].
2 Start recording.
Click [Communication(C)] on the main
menu and then click [Start
recording(S)].
Click [Yes] in [Do you want to
Proceed ?].
Click [OK] in [A measurement condition
was set.].
The gauges start recording immediately.
42 M517- E429R
■ Installing the Automatic Storage Tool of Room Temperature Logs
Note that the command differs between the Air-cooling FPD and the Water-cooling FPD.
- Air-cooling FPD
- Water-cooling FPD
M517- E429R 43
■Operation Confirmation of the Automatic Storage Tool of the Room Temperature Logs
Click the [Start] button, and point to [All Programs]. Open the [TempLog-1] menu to select the
[Loading the Data]". Check the following items:
The log is created under the "C: \Temp_rlog\No1\logs" folder.
Then, after a while, this log is transmitted to the server of the RMC, and is
moved to the "sent_log" folder.
Click the [Start] button, and point to [All Programs]. Open the [TempLog-2] menu to select the
"Loading the Data". Check the following items:
The log is created under the "C: \Temp_rlog\No2\logs" folder.
Then, after a while, this log is transmitted to the server of the RMC, and is moved to the
"sent_log" folder.
44 M517- E429R
■Confirming the Task Schedule
Click the [Start] button, and point to [All Programs]. Open the [Scheduled Tasks] folder and
check that there are the following tasks.
M517- E429R 45
9.1.2. Settings and Function of UPS control S/W(DAR-8000f Only)
This section describes how to configure the UPS control S/W and check its function. Please
check the desktop icon in order to confirm which type of UPS control S/W is installed .
・ Settings and Function of PowerChute Business Edition windows (In the case of UPS made by
APC)
Function of Power Chute Business Edition windows
The PowerChute Business Edition windows are explained here. Double-click the [APC
PowerChute Business Edition] icon on the MPC desktop to start APC PowerChute Business
Edition.
46 M517- E429R
● Device Properties
Check the device settings and change them if necessary. In the APCPowerChute Business
Edition Basic, on "view" menu, click [Device Properties]. The [Device Properties] list is
displayed. Click an item on the left to display the settings. Select the [Show advanced items]
check box at the bottom left of the window to display the [Diagnostics] and [Communications]
items.
[Summary]
No setting is required.
[Admin Information]
No setting is required.
M517- E429R 47
[UPS Identification]
No setting is required.
[UPS Status]
The UPS status is displayed. No setting is
required.
[Battery Status]
The battery status is displayed. Check that
the [Battery Status] is "Normal".
48 M517- E429R
[Power Parameters]
Make the following settings and click
[Apply].
High-Transfer Voltage: 110
Low-Transfer Voltage: 090
Sensitivity: Medium
Nominal Output Voltage: 100
Audible Warning: On Battery
[Shutdown Sequence]
Click [Configure Shutdown Sequence] to
display the setting window. No setting is
required.
Setting window
M517- E429R 49
[Shutdown Schedule]
No setting is required.
[Power Failure]
- Select [After UPS has been on battery
for]
- Set [6] minutes
[Shutdown Type]
Select [Shutdown] and click [Apply].
50 M517- E429R
[Self-Test]
The self-test results are displayed. No
setting is required.
[UPS Calibration]
No setting is required.
[Data Log]
The recorded data is displayed. Nothing is
displayed if the UPS is not operating.
M517- E429R 51
[Event Log]
The recorded events are displayed.
Nothing is displayed if the UPS is not
operating.
[Log Options]
Make the following settings and click
[Apply].
Max. Log Size: 1000
Delete Entries After: 3 Months
Data Logging Interval: 10 minutes
[UPS Communications]
The communication port settings are
displayed. No setting is required.
52 M517- E429R
[SNMP Communications]
No setting is required.
When the settings and changes are completed for all the windows, click [Close].
M517- E429R 53
● Power Event Summary
54 M517- E429R
● Voltage Analysis
M517- E429R 55
● Status
The operating status of the host and the failure status are displayed. Click the [Status] icon on
the left of the window.
The status of the host is displayed.
[System Shutdown]
When the time set in the device properties
([Shutdown] – [Power Failure]) is reached,
system shutdown starts. In this state, the
shutdown procedure continues even if
power is restored. The shutdown signal is
output continuously for approximately
2 minutes.
56 M517- E429R
・ Settings and Function of Power windows (In the case of UPS made by OMRON)
Please perform this section After checking that the units connected to UPS is turned off.
When equipment is not turned OFF, the electric supply from UPS stops during a setup,
and there is a danger that equipment will break down.
1 Double Click[ConfigShutdownParameter]
icon on the MPC desktop.
M517- E429R 57
3 Click [Boot/Reboot] Tab.
Set following settings.
●Output Start Time of UPS Boot Up
・Send Outlet Delay Command : Enable
・Outlet A(Control) : 0 Sec
・Outlet B(Control) : 0 Sec
・Outlet C(Control) : 0 Sec
●UPS Reboot Setting
・UPS Start Delay Time : 0 Sec
・Battery Capacity : 0%
●UPS Cold Start
・UPS Cold Start Function : Disable
58 M517- E429R
6 Right Screen of Console is displayed.
① [NetSearch Window Menu]
Enter "2" and Press Enter key. ①
② [Input ID and Password Menu]
Enter "3" and Press Enter key.
Enter "127.0.0.1" and Press Enter key.
③ [User Login Window]
②
Enter following value.
Login ID: Admin
Press Enter key.
Enter following value.
Password: Shimadzu ③
Press Enter key.
M517- E429R 59
9 This step is settings of UPS Battery
Change Date.
・Screen of step 8
Enter "2" and Press Enter key.
・[Reconfirm The “UPS” Setting] Screeen 9-1
Enter "4" and Press Enter key.
・[Reconfirm The “UPS” Battery Change
Date]
[Reconfirm The “UPS” Battery Change
①
Date] is displayed.(Screen 9-1)。
1 Start Date of UPS
2 New battery replace date
3 Last battery replace date(Read
Only)
②
4 Next battery replace date(Plan)
60 M517- E429R
10 This step is settings of EventLog Option.
・Screen of step8 (Screen 10-1)
①Enter "1" and Press Enter key.
・[“System” menu of PowerAct Pro
Monitor(MPC10)] (Screen 10-1) ①
②Enter "1" and Press Enter key.
Screen 10-1
・[“Log Option” menu of PowerAct Pro
Monitor(MPC10)] (Screen10-2)
②Enter "1" and Press Enter key.
①
・[“Event Log Option” menu of PowerAct
Pro Monitor(MPC10)] (Screen10-2)
Set the settings in the [2. The maximum
Event Log Record Time(Week):].
②
Set the following settings.
③Enter "2" and Press Enter key.
④Enter "12" and Press Enter key.
③
⑤[“Event Log Option” menu of PowerAct
Pro Monitor(MPC10)] is displayed again. ④
Check that the value in the [“Event Log
Option” menu of PowerAct Pro
Monitor(MPC10)] is [2. The maximum
Event Log Record Time(Week):12]. ⑤
Screen 10-2
M517- E429R 61
11 The following steps are repeated and are
performed until the screen of [“Log Option” ①
menu of PowerAct Pro Monitor(MPC10)] in
step 10 is displayed.
Enter "0" and Press Enter key.
・[“Log Option” menu of PowerAct Pro
②
Monitor(MPC10)]
①Enter "2" and Press Enter key. ③
・[“Data Log Option” menu of PowerAct Pro
Monitor(MPC10)]
The following menu is displayed.
1. Maximum Data Log Record Time(Week)
2.The record interval time <On line><Sec> ④
3.The record interval time <On
⑤
Battery><Sec>
⑦
Set [2.The record interval time <On
line><Sec>].
Set the following settings.
④Enter "2" and Press Enter key. ⑧
⑤Enter "600" and Press Enter key.
62 M517- E429R
9.1.3. Checking UPS Operation and Restarting the System (DAR-8000f Only)
When the connection between the MPC and the UPS control S/W and configuration check of
the UPS are completed, check the UPS operation using the either procedure described below:
After checking the UPS operation, return to the original status within 10 minutes irrespective of
whether the UPS operation is normal or not. If not, the system may be damaged.
1) Turn ON the power to the system (i.e., X-ray high-voltage generator and DAR-8000).
2) From the PCU Xcat "power control", check that the HV and DC power supplies are both
ON.
3) With the "power control" window displayed, turn OFF the power supply on the side of the
PSU rack. (See photo below.) (The power supply from "200 / 220 / 230 / 240 V" * to
100 VAC is turned OFF.)
4) Check that the HV and DC power are turned OFF. The UPS operates and an audible
warning is generated.
*The power voltage is different according to region.
1) Turn ON the power to the system (i.e., X-ray high-voltage generator and DAR-8000).
2) From the PCU Xcat "power control", check that the HV and DC power supplies are both
ON.
3) With the "power control" window displayed, turn OFF the power supply on the side of the
PSU rack. (See photo below.) (The power supply from "200 / 220 / 230 / 240 V" * to
100 VAC is turned OFF.) The UPS operates and an audible warning is generated.
4) Check that the PCU and MPC automatically shuts down and the HV and DC power are
turned OFF 10 minutes after turning off the power supply.
5) Check that the UPS automatically shuts down 12 minutes after turning off the power
supply.
M517- E429R 63
The trans may make oscillation noise in case UPS has no loads, but it isn’t problem.
Its noise ceases if loads are applied. (Any loads are applied under normal use.)
電源
Plugs
64 M517- E429R
Plugs
Power supply Power supply
Plugs
Water-cooling FPD PSU RACK (PSU RACK2)
(33-a) (33-b)
To DC MAIN (30-b)
D
B D (34-a)
To HV MAIN (33-a) To PCU
C
Overcurrent Protection Overcurrent Protection
Reset button To DC MAIN Reset button
(33-b)
INPUT INPUT
To PS CTRL 120V 50/60Hz 120V 50/60Hz
Board To PSU TRANS To PSU TRANS
(33-c) (33-c)
M517- E429R 65
To PS Ctrl To PCU
To PCU (33-b) (34-a)
(34-d)+(34-e)
To HUB
To DC Main(48)
To PSU Trans
To MPC
(33-c)
In 10 minutes after checking the operation, restore the state of power to what it was
before the check regardless of whether the operation is correct or wrong.
If you do not so, the system may be damaged.
66 M517- E429R
■ Restarting the System
After checking UPS operation, restart the system using the following procedure.
M517- E429R 67
After installation, contact the Remote Maintenance Center to request connection and
operation confirmation.
After the following network settings are entered in a notebook PC, remote desktop
connection from this PC is possible.
IP Address: 192.168.100.200
Subnet mask: 255.255.255.0
Default gateway: ___. ___. ___ . ___ (Empty spaces, no numbers)
68 M517- E429R
(2) From the Start menu, select [All Programs] – [Startup] – [Simple_Storage] to execute the
program.
*With the MPC factory setting, when the power is turned on, [Simple_Storage] starts
automatically. The task of [Simple_Storage] appears in the task bar.
M517- E429R 69
9.1.5. "Osiris" Installation
Send images of DAR-8000 to MPC and display it on the screen of MPC in order to capture a
problematic image on MPC.
(1) Send images of DAR-8000 to the MPC. (Select the Simple_MPC to send images.)
(2) Check that there are files that are sent from DAR-8000 in the C:\Image\XRF folder of the MPC.
(3) Start the Osiris4 and check that the image file in the C:\Image\XRF folder is displayed.
UD CONT-2002 UD CONT-2002X
70 M517- E429R
(2) Run configuration tool in ‘C:\B40_rlog\ChangeUdRemolog’ folder.
For UD CONT-2002X: Run ‘ChangeUdRemolog_2002X.exe’.
For UD CONT-2002: Run ’ChangeUdRemolog_2002.exe’.
(3) The serial port configuration is changed and following screen appeares. Press [OK] to close.
(4) Click [X] to close TeraTerm window named ‘UD Terminal – COM1 VT’.
(5) Restart ‘C:\B40_rlog\remolog.exe’ from Windows Explorer.
(6) Click [UD Terminal – COM1 VT] on the task bar to show TeraTerm window.
(7) Press [Enter] key and check the prompt "UD>" is displayed.
M517- E429R 71
9.1.7. BB Remote Maintenance Setting and Checking
This setting is required only for the BB remote maintenance. Do not set it for the
ISDN remote maintenance.
72 M517- E429R
9.1.8. Checking the UltraVNC
VNC icon
When all installations are finished, request connection confirmation to the remote maintenance
center.
M517- E429R 73
9.2. DAR-8000 Settings
9.2.1. DAR-8000 Network Settings
(DAR-8000f)
5 Double-click [Local Area Connection]. The [Local
Area Connection Status] window opens.
(DAR-8000i)
5 Double-click [Local Area Connection2]. The
[Local Area Connection2 Status] window opens.
(DAR-8000f)
6 Click [Properties]. The [Local Area Connection
Properties] window opens.
(DAR-8000i)
6 Click [Properties]. The [Local Area Connection2
Properties] window opens.
74 M517- E429R
7 Select [Internet Protocol (TCP/IP)] and click
[Properties]. The [Internet Protocol (TCP/IP)
Properties] window opens.
M517- E429R 75
9.2.2. Installing and Setting the UltraVNC in the DAR-8000
Install the UltraVNC in the DAR-8000 and make the required settings.
■ Preparation
76 M517- E429R
■ Install UltraVNC
1 Click [Next>].
3 Click [Next>].
M517- E429R 77
4 Click [Next>].
6 Click [Next>].
78 M517- E429R
7 Clear the[Download Vista addons files
now]check box and click [Next>].
10 Click [Install].
M517- E429R 79
11 The installation is started and the
window below appears. Wait for a
while.
80 M517- E429R
15 Click [Admin Properties]. The
[UltraVNC Server Property Page]
window is displayed.
M517- E429R 81
■Confirmation
(1) The VNC icon is displayed on the Task bar.
(2) After the set-up is completed, the "UltraVNC Server" and "UltraVNC Viewer" icons are
displayed on the desktop.
(3) Drag and drop the "UltraVNC Server" and "UltraVNC Viewer" icons into the "VNC" folder in
the My Documents folder.
(4) When each terminal installation is completed and checked, access to the remote
maintenance center to check the connection.
82 M517- E429R
9.2.3. Installing the DAR-8000 Automatic Log Transfer Batch File
At startup, the automatic log transfer batch file (D8K_logcopy.bat) automatically connects the
MPC and the DAR-8000, and creates a folder named using the current day's date/time in the
MPC's C:\Diag\DAR8k folder. It copies the entire contents of the DAR-8000's C:\Diag folder to
this folder. This makes it easy, in subsequent maintenance, to refer to logs for days on which
problems occur.
(1) Close all applications and return to the Windows display. (If the auto log-off and auto
power-off settings are enabled, display the system settings window from the [Start] dialog
box and disable these settings. Refer to Appendix B "Various Basic Settings" in DAR-8000f
Installation Manual / M517-E383.)
(2) Set the setup CD "DAR-8000, Remote Maintenance S/W (502-24707)" in the DAR-8000
and open the [D8_LogCopy] folder in setup CD using Windows Explorer.
(3) Double-click [InstLogcopy.bat] to run the installation program. The following window is
displayed.
(4) Type the MPC's IP address (usually "192.168.100.10") and press the ENTER key.
[LogCopy has installed!] is displayed in the window.
M517- E429R 83
(5) When [LogCopy has installed!] is displayed, press any key. Installation is completed.
(6) Press the key (corresponds to the (Windows) key) to display the task bar. Select
[Programs] – [Startup] on the Start menu and check that [D8K_logcopy.bat] is displayed on
the [Startup] menu.
(7) After restarting the system and DAR-8000 starts, check that the log file is copied to the
MPC with reference to the description [Checking the Copying of DAR-8000 Log Files].
The log file is not copied over if connection to the MPC is not possible via the network.
84 M517- E429R
9.2.4. Checking the Storage of DAR-8000 Data
Check that data is sent from the DAR-8000 to the MPC's storage server.
■ Registration at the DAR-8000
With reference to "Settings for DICOM Transmission and DICOM CD Writing" in the DAR-8000i
Installation Manual (M517-2135 (Japanese)/M517-E380 (English)) or the DAR-8000f Installation
Manual (M517-2139 (Japanese)/M517-E383 (English)), register [SimpleStorage], which is
installed in the MPC, at the DAR-8000 using the information given in the following table.
M517- E429R 85
9.3. PCU Settings (DAR-8000f Only)
9.3.1. PCU Settings
86 M517- E429R
5 Click [Change my password]. The next
window is displayed.
M517- E429R 87
8 Click [Run] on the Start menu. The
next window is displayed.
88 M517- E429R
■ Extension Display Settings
M517- E429R 89
■ Stopping the Display of Security Center Alerts
90 M517- E429R
■ Disabling the Security Center Settings
If [Firewall] and [Automatic Updates] in the Windows Security Center settings are set to [ON],
use the procedure described below to set them to [OFF].
1 Click [Automatic Updates] in the
[Windows Security Center]
window. The [Automatic Updates]
window is displayed.
M517- E429R 91
4 Click the [General] tab and select
[Off (not recommended)].
5 Click [OK].
92 M517- E429R
9.3.2. PCU Network Settings
1 Turn on the power to the PCU. The
Windows starts.
2 Open the [Control Panel] window and
double-click [Network Connections].
The [Network Connections] window is
displayed.
M517- E429R 93
4 Click the [General] tab and select
[Internet Protocol (TCP/IP)].
5 Click [Properties]. The [Internet Protocol
(TCP/IP) Properties] window is
displayed.
94 M517- E429R
9.3.3. Remote Maintenance Setting
1 Turn on the PCU.
The Windows starts.
2 Click the [Start] button, point to [All
Program] -> [Shimadzu PCU Tools], and
then click [Remote Maintenance
Config]. "Remote Maintenance Config
Tool" is displayed.
3 Input as follows:
・ PCU Unit No: 1
・ Host Name: MPC address
Example 192.168.100.10
・ User Name: Administrator
・ Password: Shimadzu
4 Click the "Check" button to check the
connection with MPC. The dialog of
"Check completed [OK]." is displayed.
Click [OK] to close the dialog.
M517- E429R 95
9.4. Side Station Settings (Only Required If Side Station Is Used)
When the OS of the Side Station is Windows 7, refer to section 9.5. "Side Station
(Windows 7) Settings (Only Required If Side Station Is Used)".
96 M517- E429R
3 Double-click [Local Area Connection].
M517- E429R 97
9.4.2. Setting the Remote Desktop of the Side Station
For the connection establishment, the computer accessed from remote locations must
open port 3389 to the outside. If the firewall or broadband router of the company
exclusive line blocks this port, or if the firewall function of Windows XP or other
commercially available firewall software does not allow data to pass through the port
3389, user cannot access the computer from remote locations using the Remote
Desktop function. In those cases, ask the network administrator to open the port 3389
or change the firewall settings to open it.
98 M517- E429R
9.4.3. Installing the Automated log transfer batch file of Side Station
Automated log transfer batch file(PPWS_logcopy.bat)automatically connects the MPC and the
Side Station on startup and create a folder named using the current day's date/time in
C:\Diag\ PPWS folder in the MPC. To this folder, all contents of D:\Shimadzu\Log folder in the
Side Station is copied, making it easier on maintenance later to find out the log of the day when
an error occurs.
(1) Log on the Side Station as user "shimadzu". Refer to section 4.4.1 "Logging On" in
"M517-E078 Side Station Installation Manual".
(2) Insert the setup CD "DAR-8000 Remote Maintenance S/W" (502-24707)into the CD drive
of Side Station. Open the "PPWS_LogCopy" folder inside this CD using Windows Explore.
(3) Double click [InstLogcopyPPWS.bat] to execute it.
The following window is displayed.
M517- E429R 99
(5) Press any key after [LogCopy has installed!] is displayed.
The install is done.
(6) After restarting the system, confirm the log file is copied to MPC on the startup of the Side
Station, referring the following "Checking the Copying of Side Station Log Files".
1)
The log file is not copied over if connection to the MPC is not possible via the network.
Check that data is sent from the Side Station to the MPC's storage server.
■ Registration at the Side Station
With reference to "Settings for DICOM Transmission" in "M517-E078 Side Station Installation
Manual", register [SimpleStorage], which is installed in the MPC, at the Side Station using the
information given in the following table.
(*1) This IP address is a standard. Specify the IP address assigned to the MPC at the installation site.
When the OS of the Side Station is Windows XP, refer to section 9.4. Side Station
Settings (Only Required If Side Station Is Used)".
Settings of 8.5.3, 8.5.4, 8.5.5, and 8.5.7 were completed at the time of shipment of the
Side Station. Perform these setting, only when a change is made.
4 Click [Properties].
The [Local Area Connection
Properties] window is displayed.
For the connection establishment, the computer accessed from remote locations must
open port 3389 to the outside. If the firewall or broadband router of the company
exclusive line blocks this port, or if the firewall function of Windows XP or other
commercially available firewall software does not allow data to pass through the port
3389, user cannot access the computer from remote locations using the Remote
Desktop function. In those cases, ask the network administrator to open the port 3389
or change the firewall settings to open it.
5. Click [OK].
5. Click [OK].
5. Click [OK].
6. Click [OK].
The confirmation dialog is displayed.
8. Click [OK].
1 Click [Next].
3 Click [Next].
4 Click [Next].
6 Click [Next].
10 Click [OK].
*The right window is the error
displayed when not downloading the
mirror driver.
11 Click [Next].
■ Confirmation
(1) Display the VNC icon on [Show hidden icons] of the task bar.
2)
(2) The "UltraVNC Server" and "UltraVNC Viewer" icons are displayed on the desktop after the
setup is completed.
3)
(3) Dragging and dropping the "UltraVNC Server" and "UltraVNC Viewer" icons to the VNC
folder created in the My documents.
4)
(4) After installation and confirmation are completed, contact the Remote Maintenance Center
to request connection and operation confirmation.
-LEDs of LAN and ISDN/BB of the ISDN/BB router are turned on.
-The Windows authentication of MPC is completed. (Contact to Microsoft Corp. and input
authentication ID.)
This section describes how to set UD150B-40/L-40, ZS-100, and SGIM connected to MPC with
the serial cable to use them other than the normal operation.
When the shortcut to Ttermpro is not on the desktop, create the shortcut to C:\Program
files\TTERMPRO\ttermpro.exe and move it to the desktop.
This book describes the connection procedures. Refer to each document about the
operation of each unit.
(5) [Network Connection] is displayed. Click [Serial] and select [COM1] from the list as "Port".
Click [OK].
(7) In "Serial port setup" window, set as follows and click [OK].
(8) Press [Enter] key and check the prompt "UD>" is displayed.
Make sure to start "remolog.exe". If "remolog.exe" does not start, the log of
UD150B-40/L-40 will be not stored until MPC restarts.
(2) In [New Connection] window, click [Serial] and select [COM2] from the list as "Port".
Click [OK].
(4) In "Serial port setup" window, set as follows and click [OK].
Do not forget the start of SGIMRlog.exe. If you do not start it, SGIM log is not saved
until the MPC restarts.
(2) In [New Connection] window, click [Serial] and select [COM3] from the list as "Port".
Click [OK].
(4) In "Serial port setup" window, set as follows and click [OK].
Do not forget the start of RF_LOG_Start.exe. If you do not start it, RF_Table log is not
saved until the MPC restarts.
Do not perform "Start Agent" until you submit "Site-ViewBB Customer Registration /
Connection Consent Request".
This section describes the common tool used for all version of BBRM.
At the time of shipment of the MPC, the proxy connection conditions under the LAN
environment where MPC is installed are unknown. Therefore, the BBRM-Agent is unavailable.
When installing the MPC, the proxy connection setting may be needed before starting the
BBRM-Agent. If proxy connection is needed, set up the proxy connection settings by referring to
the section below according to the BBRM version installed.
To start the BBRM-Agent, double-click the "Start Agent" shortcut in the Start menu. As shown in
the following figure, the command prompt appears and disappears after a while.
After that, In the case of BBRM Version 2.3.0 or earlier, both the Axeda-Connector and the
Axeda-Remote will be available and started automatically at the time of starting the system.
In the case of BBRM Version 3.0.1 or later, only the Axeda-Connector will be available and
started automatically at the time of starting the system.
Refer to the table below for the function of Axeda-Connector and the Axeda-Remote.
Title Function
Axeda-Connector Used in BBRM "2.3.0 or earlier" and "3.0.1 or later".
Notify the status of MPC to the BBRM-Server periodically.
Axeda-Remote Used in BBRM "2.3.0 or earlier".
Allow user to refer the console window of MPC from the
outside via the BBRM-Server.
Double-click the "Stop Agent" shortcut in the Start menu. In the case of BBRM Version 2.3.0 or
earlier, both the Axeda-Connector and the Axeda-Remote, in the case of BBRM Version 3.0.1 or
later, the Axeda-Connector will be stopped.
The following command prompt appears and disappears after a while.
Both the Axeda-Connector and the Axeda-Remote will not be started at the time of starting the
system.
The operation methods of the tools except the common above differ depending on the BBRM
versions installed. Refer to either section in the table below according to the BBRM version.
You can see starting icons of various services tools, including the proxy connection conditioning
settings, for performing introduction, operation, and administration of the BBRM-Agent in the
Start menu of the MPC. (Refer to the following figure.)
To display the Start menu, click the [Start] button at the lower left corner of the window, and then
point to the "All Programs".
When the line for remote maintenance is available, no setting in this section is needed.
Please go to next section (9.2.2.2.).
The current proxy setting status and buttons are displayed. (Refer to above figure.)
Clicking [No] does not change the proxy setting, and exit the tool.
Clicking [Yes] will open the proxy setting. (Refer to the following figure.)
When clicking [No], the proxy setting will not be used (Disable), and the proxy setting
confirmation window will be displayed.
When clicking [Yes], the proxy setting will be used (Enabled), and the following proxy IP
address setting window will be displayed.
When clicking [Cancel], the proxy setting will not be changed, and the proxy setting tool will be
closed.
The proxy setting above will be applied to the BBRM-Server communication in both the
Axeda-Connector and the Axeda-Remote.
Double-click the "DisplaySerialNumber" shortcut in the Start menu. The model name and serial
numbers as the Agent station of MPC are displayed.
Clicking [OK] will close the serial number display window (above figure).
The serial number as the Agent station of MPC was set at the time of shipment of MPC. When
you need to change the serial number when replacing the MPC or with other reasons, follow
procedures below.
Double-click the [Change SerialNumber] shortcut in the Start menu. The serial number of the
current Agent station is displayed.
Clicking [NO] does not change the serial number, and exit the tool.
Clicking [YES] will open the following window to input the serial number.
In normal operation, proxy setting will be common between the Axeda-Connector function and
the Axeda-Remote function by execution of "Change ProxyAddress" at the time of installation.
However, the proxy setting to the Axeda-Remote can be changed in the properties during
operation. Therefore, when the Axeda-Remote does not work correctly, the actual setting detail
can be checked.
To check the setting detail, double-click the "Display ProxyAddress for RemoteAccess" shortcut
in the Start menu. The current proxy settings in current Axeda-Remote and copy instruction
button are displayed. (Refer to the following figure.) If the settings displayed differ from those
set in section 10.2.2.1. "Setting Proxy Connection Condition for BBRM-Agent (Change
ProxyAddress)", repeat the setting in section 10.2.2.1.
When clicking [No], the proxy setting will not be changed, and the proxy setting tool will be
closed.
When clicking [Yes], copy the displayed proxy settings of Axeda-Remote to the proxy setting of
the Axeda-Connector.
The Axeda-attached tool, Deployment, is used for various setting for introduction, operation, and
administration of the BBRM-Agent. Click [Axeda] of the Start menu -> [Deployment] -> [Axeda
Deployment] to start the Deployment. (Refer to the figure below.)
The start screen of the Axeda Deployment appears. Please wait for a while.
The window below appears. Click [Agent is installed on this computer], and [OK].
The BBRM-Agent communicates with the BBRM-Server via the Internet. When the proxy exists for
connection to the Internet, proxy connection setting is necessary on MPC. (The browser setting is
also required.) Follow the procedure below.
(2) Click [Basic Information] and select the "Update the Agent's identification" check box.
(5) Move the cursor to "Serial" of Deployment and press [Ctrl]+[v] of the Keyboard.
Press [Ctrl]+[v].
When the line for remote maintenance is available, the proxy setting here is not need.
(6) Click [Enterprise Servers] and select [Enable HTTP Proxy] check box.
(9) The window asking whether to continue processing or not appears. Clicks [Yes].
*When clicking [Yes], the changes are saved, and the Agent is restarted
and connected with the BBRM-Server. When neither the router nor
others are set up, or when connection with the remote maintenance
center is not established, the "connection failed" message appears.
Click [OK] to close it. (Even in this case, the changes are saved.)
The PCU Xcat must be 1.20.513.0 or later. If the Xcat is earlier than it, upgrade the
Xcat.
2) The following window will display. Write down the value of Serial Number (S/N).
(1) Insert "DAR8000 Remote Maintenance Master CD" (Revision.03.00.01 or later) in the drive
of the MPC. Execute "D:\BBRM\Install Service Link 5.2 for DAR-8000f.vbs".
(2) Execution of the Install Service Link 5.2 for DAR-8000f.vbs will display the following
window. Click [OK] to continue processings and [Cancel] to stop it.
(3) The following window appears when [OK] is selected in step (2). Wait for a while until the
next window appears.
(5) The window to check the license appears. Click [I accept the terms of the License
Agreement], and [Next].
(7) The window to specify the location of the shortcut appears. Just click [Next].
(9) After starting the installation, the window below appears. Wait for a while.
(11) After a while, the window to start the installation of UltraVNC appears. Click [Next>].
The window above may be hidden behind other window. Check the task bar and click
the UltraVNC icon.
Click it.
(15) The window to select the component to be installed appears. Just click [Next>].
(The "Full installation" is selected in the example below.)
(17) The window to install the add-on appears. Clear the check box and click [Next>].
(19) The window to select the additional function appears. Just click [Next>].
(21) The installation is started and the window below appears. Wait for a while.
The window below may appear after starting the installation. Click [Yes].
(23) When installation is completed, the window below appears. Click [Finish] to close the
window.
(24) The window below appears when all the processings are completed normally. Click [OK] to
close the window.
(27) The window below appears. Check [Allow Loopback Connections] check box and clear
[User impersonation (for Service only)]. Then click [Apply] and close this dialog.
Check
Clear
The version of BBRM installed in the MPC can be checked in the procedure below.
(1) Open the "C:\Axeda\BBRMVersion.dat" file in the Notepad.
Agent Version
The error window below appears to notify an application that has not been installed. Nothing is
displayed when all the applications have been installed normally.
* When this error occurs, it is necessary to install only the application not installed again. Select
the execution file in the table below according to the application name displayed on the window
and execute it to again install it.
(1) From the Start menu of PCU, select [All Programs] - [Accessories] - [Communications] -
[Remote Desktop Connection].
(4) Exit the running PCU Error Monitoring Tool. Right-click the "PCU" icon displayed on the
right side of the task bar, and then click [Exit] on the popup menu to exit the program.
(5) With the Windows Explorer, move to "C:\PCUErrSend" and delete all the files in the folder.
(6) Insert "DAR8000 Remote Maintenance Master CD" (Revision.02.50.00 or later) in the drive
of the MPC. Execute "\MPC_PCU_ALERT_TOOL\PCUErrSendInst.bat".
(7) The next window appears. Click [Yes] for the Water-cooling FPD and click [No] for the
Air-cooling FPD.
(9) From the Start menu of PCU, select [All Programs] - [Startup] - [PCU Error Send] to start
the PCU Error Monitoring Tool.
(10) Check that the "PCU" icon is displayed on the right side of the task bar. When it is not
displayed, repeat from the step (5).
For the Air-cooling FPD, execute the steps (13) and (14). Move to step (15) for the
Water-cooling FPD.
(13) Click the [Start] button, and point to [All Programs]. Open the [TempLog-1] menu to select
the [Stop Scheduling].
The scheduler of No1 is canceled.
(14) Click the [Start] button, and point to [All Programs]. Open the [TempLog-1] menu to select
the [Start Scheduling Daily].
The scheduler of No1 is registered. (Executed early on every morning.)
For the Water-cooling FPD, execute the steps (15) and (16).
(15) Click the [Start] button, and point to [All Programs]. Open the [TempLog-1] menu to
select the "Stop Scheduling".
The scheduler of No1 is canceled.
(16) Click the [Start] button, and point to [All Programs]. Open the [TempLog-1] menu to
select the [Start Scheduling Weekly].
The scheduler of No1 is registered. (Executed early on every Sunday.)
(1) Execute the VERSIONUP.vbs in the status with the BBRM installed. The Agent may run at
the execution.
(2) Execution of VERSIONUP.vbs will display the following window. Click [Yes] to upgrade.
Click [No] to cancel upgrade.
(3) The following window appears when [Yes] is selected in step (2). Click [Close] at the
bottom of the window to complete the processing as early as possible. You may not click it.
(After predetermined time (15 seconds), the next processing will automatically start.)
(5) The following window appears when all the processings are completed normally. Click [OK]
to exit upgrade processing.
Click [Start] -> [All Programs] -> [Display BBRM version] to check the version of BBRM installed
in the MPC.
* The BBRM may not be installed in the PC when this error occurs. When the BBRM is not
installed, execute the SETUP.bat file to set up it. In addition, when setup is performed with
SETUP.bat, execution of the VERSIONUP.vbs is unnecessary.
The error windows below are the example for absence of a file required for upgrade in the
MPC.
* When a window above appears, an error may have occurred during the upgrade
processing, resulting in data mismatching.
Therefore, once execute the UNINSTALL.bat manually to clear data, then, execute
SETUP.bat. In this case, re-execution of the VERSIONUP.vbs is unnecessary.