1. BLOWER Selection of proper blower is most important step in the set-up of cupola. Blower
must be purchased from a reputed manufacturer. Before taking the delivery of the
blower, its air pressure and air volume must be checked as per BIS standard tests.
2.wrong installation,
B. The blower does not develop design pressure 1.Check blower running backward 2.Operating at high altitude
6. Low voltage 7.Lower cycle current than for which the motor is rated 8.Drive belt loose
C.Noise
1.Checkimpellerhitting inlet ring cutoff, pulleys not tight on shaft, belts too loose Belts too tight, pulleys is aligned, motor
and fan belt s loose.
2.Bearings defective, needs lubrication, 3.Impeller loose on shaft, defective impeller, unbalanced impeller, worn out
impeller
5.Leak in ducting
D.CFM low
1.Forward curved impeller installed back ward,Fan running back ward, cutoff missing or i improperlyinstalled, fan speed
too low
3. Elbows or other obstructions restrict air flow no straight duct at fan outlet,
E. CFM high
1.Obstruction in system,
I. HP High
3. Oversized duct
Maintenance of Blower
Remove dust from impeller and casing once a year in general and more frequentlywhere environment is dust laden Motor
bearings may require lubrication, jackshaft bearings should be greased every six months
Replace V-belts once a year, check V-belts tension daily, Loose V-belts will reduce blower speed, increase belt friction
causing heating of motor and bearings
2.Blast Pipe
Blast pipes supply air from blower to cupola. For minimum loss of air in the system,1.the size of the pipe should be
adequate. 2.Pipes should be straight and 3.with minimum bends andbranches 4.Butterfly valves shouldbe provided inthe
pipesfor controlling air 5.There should be no leakages in the blast pipe to avoid loss of pressure.
The purpose of wind box is to nullify the pulsations of the air and to supply air