Impack Pratama Laboratory&Testing

PERFORMANCE TEST REPORT

Report No: A002.220814


Test Dates: 20/08/14
Through: 21/08/14
Report Date: 22/08/14

Sample : Aluminum Composite Panel, found in market with brand Good Sense

Test purpose : to evaluate some critical parameter and compare with Alcotuff-
Alcolite

Test result :

Brand
parameters side Unit
Good
Alcolite Alcotuff
Sense
top coil mm 0.24 0.32 0.53
thickness of skin
back
coil
mm 0.24 0.32 0.53

top coil alloy 1100 3003 3003


alloy serie of Aluminum
back
coil
alloy 1100 3003 3003

top coil µm 20 25 32
thickness of coating
back
coil
µm 10 10 10

coating type top coil polyester pvdf pvdf


back
coil
polyester polyester polyester
adhesion strength of skin to N.mm/
110 110
top coil
mm
66
core,
back N.mm/
coil mm
66 110 110

top coil µm 30 100 100


thickness of adhesive layer
back
coil
µm 30 100 100
type of Fire Retardant Mineral,
ATH more sensitive to heat, core MDH MDH ATH
ATH activate at 220 ‘C, MDH at 330’C

Results obtained are tested values and were secured using the designated test methods. This report does
not constitute certification of this product nor an opinion or endorsement by this laboratory. This report
may not be reproduced, except in full, without the approval of Impack Pratama Laboratory.