You are on page 1of 2

Cable MT NFC 33-226 18/30 (36) kV

NF C 33-226 18/30KV 1x240 AL PE

Nexans Ref.: 57270240400

18/30 kV cables in copper or aluminium

DESCRIPTION
Usage
NFC 33­226 cables are for public power distribution network 18/30 (36) kV.

Design
The cable is made of 1 or 3 cores, without mechanic protection

STANDARDS
National NF C 33­226

CHARACTERISTICS
Construction characteristics
Conductor material Aluminum
Conductor exibility Stranded class 2
Conductor shape Circular
Insulation XLPE (chemical)
Material of the external semi­conductor Extruded strippable grooved elastomer
Material of the inner semi­conductor XLPE­SC
Material used for longitudinal water tightness Swelling powder
Outer sheath PE
Screen Longitudinal aluminium tape
Sheath colour Black
Dimensional characteristics
Conductor cross­section 240 mm²
Number of cores 1
Approximate weight 1550 kg/km
Conductor diameter 18.3 mm
Diameter over insulation 34.2 mm

Conductor exibility Rated Voltage Uo/U Mechanical Cable exibility Flame retardant Weather resistance Chemical Water proof


Stranded class 2 (Um) resistance to Rigid C2, NF C 32-070 Good resistance Intermittent
18 / 30 (36) kV impacts Accidental
Good

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 2/17/22 www.nexans.ma Page 1 / 2
Cable MT NFC 33-226 18/30 (36) kV
NF C 33-226 18/30KV 1x240 AL PE

Dimensional characteristics
Maximum outer diameter 41.5 mm
Electrical characteristics
Rated Voltage Uo/U (Um) 18 / 30 (36) kV
A.C. Conductor resist. at 90 °C ­ trefoil formation 0.161 Ohm/km
Conductor AC resistance at 50 Hz 0.11 Ohm/km
Max. DC resistance of the conductor at 20°C 0.125 Ohm/km
Nominal inductance 0.1 mH/km
Nominal phase capacitance 0.23 µF / km
Perm. current rating buried 20°C ­ trefoil formation 399 A
Perm. current rating in air 30°C ­ trefoil formation 494 A
Voltage Drop 0.34 V/A.km
Mechanical characteristics
Mechanical resistance to impacts Good
Cable exibility Rigid
Usage characteristics
Flame retardant C2, NF C 32­070
Weather resistance Good
Chemical resistance Accidental
Water proof Intermittent
Bending factor when laying 15 (xD)
Length 1000 m
Max. conductor temperature in service 90 °C
Short­circuit max. conductor temperature 250 °C

SELLING AND DELIVERY INFORMATION


Contact us for any other options.

Conductor exibility Rated Voltage Uo/U Mechanical Cable exibility Flame retardant Weather resistance Chemical Water proof


Stranded class 2 (Um) resistance to Rigid C2, NF C 32-070 Good resistance Intermittent
18 / 30 (36) kV impacts Accidental
Good

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 2/17/22 www.nexans.ma Page 2 / 2