You are on page 1of 1

CHAPTER 6 - MAINTENANCE AND ADJUSTMENTS

MAINTENANCE FOR NIBBLER/BREAKER


It is necessary to perform the following maintenance
schedule in regard to hydraulic oil and filters along WARNING: Gasses from hydraulic tank may
with the normal inspection and maintenance. be hot. Wear safety equipment. Failure to
comply could result in serious injury or death.
REPLACEMENT SCHEDULE 2. Make certain all hydraulic pressure is released.
1st 2nd Regular Depress air release button to release hydraulic
Item Location
Maintenance Maintenance Maintenance tank pressure.
Every 600
Hyd. Oil Hyd. Tank - -
Hours

Return Every 250


Hyd. Tank 50 Hours 250 Hours
Filter Hours

WARNING: Never change oils or filters on a


machine that has just finished working. Allow
machine to cool first until oils and fluids are
warm not hot. Release hydraulic tank
pressure before working with any hydraulic
components. Failure to comply could result in
serious injury or death. 1
DC04B340 Figure 161

1. MOUNTING BOLTS

WARNING: Slowly remove the mounting


bolts. The filter cover plate is under spring
tension. Failure to comply could result in
serious injury or death.
3. Remove the SIX mounting bolts from the
hydraulic return cover plate.

1
DC04B674 Figure 159 4
1. Keep all unauthorized personnel clear of the 2
area. Move machine to firm level ground and
place attachment in oil level check position.

5
3
3
6

1
BS06H083 Figure 162

1. CAP SCREW 4. SPRING


DC04B339 Figure 160 2. COVER PLATE 5. BYPASS VALVE
3. O-RING 6. RETURN FILTERS
1. AIR RELEASE BUTTON

84138661NA Issued 08-08 Bur 6-57