AIR
CONDITIONERS
LINE-UP
PRODUCT CATALOGUE 2017
SPLIT / WINDOW
50
HZ
ABOUT US
High reliability products High reliability products High Quality Development & Production Facilities
1971 Air conditioner exports to Middle East. Advanced Research Facility and Equipment
Commercial
Sound testing Calorimeter testing Air flow testing
Compressibility testing
Reliability Testing
VRF tropical series
Big Multi
Testing Laboratory
Fujitsu General EMC Laboratory Limited
60 m Height Difference Testing Tower
Objective is to confirm
oil circulation of compressor for reliability
2 3
PREMIUM Wall Mounted Powerful mode is more power-up! Powerful airflow
Powerful airflow
• Possible to cool every corner of the big room immediately. Large LCD display
• High power cooling even if high ambient (52ºC) Easy to operate new square design
• Further improved energy saving performance One touch Powerful cooling mode
ASGA18 / 24 / 30 / 36
Easy to use large cursor key
4 5
Circular Airflow Cassette Circular airflow control
without temperature
• Improved installation in office environments
unevenness.
Ø7mm high density heat exchanger
• Optimum operation by monitoring the room temperature AUGA18 / 25FRTA-U
" " brand air conditioners are selected & loved around the world
" " brand air conditioners promise to make your daily life more comfortable, and are highly valued by customers in more than
100 countries around the world.
Since starting our air conditioner business in the Middle East, our air conditioners have earned
a high reputation for being able to withstand severe high temperatures like those encountered in tropical and desert regions.
We are also developing innovating new technologies, such as the DC inverter, automatic clean filter, and VRF system,
in our pursuit of a more comfortable room. You can feel the difference. Welcome to " "!
Capacity
(BTU/h) Wall Mounted Type Cassette (Compact) Type Cassette Type Duct Type Window Type
NEW
18,000 18,000
24,000 24,000
NEW
25,000 25,000
AUGA25FRTA-UX ARGA25FMTA-UZ
NEW
30,000 30,000
NEW
36,000 36,000
NEW
45,000 45,000
AUGA45FRTA-UX ARGA45FMTA-UZ
NEW
54,000 54,000
AUGA54FRTA-UX
60,000 60,000
ARGA60FHTA-UZ
R407C
90,000 90,000
ARG90ELC3Z
Non stop operation up to 52°C ambient Non stop operation up to 60°C ambient
10 11
WALL MOUNTED TYPE
Unified Chassis
Handy Type
Powerful cooling 30 class standard model
ASGA18/24/30/36FUTB-U
Higher cooling capacity is achieved at the ambient 10 % up 25,600
temperature of 52°C condition.
ASGA18/24FUTB-U (30)
ASGA30/36FETA-U
23,200
*:18 class
:* (18) (24) (30) (36)
setting temp.
New models accelerate to cool air quicker to reach the setting
18 % faster!
SPECIFICATIONS
temperature in the entire room than the current models do.
2.5m Set ASGA18FUTA-UZ ASGA18FUTB-UZ ASGA24FUTA-UZ ASGA24FUTB-UZ ASGA30FUTA-UZ ASGA30FETA-UZ ASGA36FUTA-UZ ASGA36FETA-UZ
than current model Model No. Indoor Unit ASGA18FUTA-U ASGA18FUTB-U ASGA24FUTA-U ASGA24FUTB-U ASGA30FUTA-U ASGA30FETA-U ASGA36FUTA-U ASGA36FETA-U
60cm 10m Outdoor Unit AOGA18FUTAHU AOGA18FUTBRU AOGA24FUTAHU AOGA24FUTBRU AOGA30FUTASU AOGA30FETASU AOGA36FUTASU AOGA36FETASU
Capacity Class Btu/h 18,000 18,000 24,000 24,000 30,000 30,000 36,000 36,000
10m
Power source V/ø/Hz 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
22.0 23.0 24.0 25.0 26.0 27.0
Temperature °C Energy Label 5 4 4 4 4 2 4 3
Cooling kW 5.33 5.65 7.03 7.05 8.17 8.80 10.55 10.55
Capacity
Indoor temperature of 27°C DB, and outdoor temperature of 35°CDB Cooling Btu/h 18,200 19,300 24,000 24,100 27,900 30,000 36,000 36,000
Setting temperature:24°CDB, High airflow mode, 30 class CFD T1 Input power Cooling kW 1.53 1.74 2.06 2.16 2.35 2.85 3.10 3.25
simulation results after 250 seconds from the start. condition Current Cooling A 6.7 8.2 9.2 10.1 10.4 12.6 14.2 14.6
Power Factor Cooling % 99.3 92.3 97.4 93.1 98.2 98.3 94.9 96.8
EER Cooling kW/kW 3.48 3.25 3.41 3.26 3.48 3.09 3.40 3.25
Cooling kW 4.77 4.86 6.25 6.00 7.23 7.50 9.38 9.15
Capacity
Cooling Btu/h 16,300 16,600 21,300 20,500 24,700 25,600 32,000 31,200
T3 Input power Cooling kW 1.80 1.99 2.45 2.46 2.85 3.48 3.85 4.00
New Technology 1 Dual suction design 2 New long cross-flow fan 3 High output DC fan motor condition Current Cooling A 7.9 9.3 10.8 11.3 12.6 15.3 17.3 17.9
Large airflow volume from dual suction Power Factor Cooling % 99.1 93.0 98.6 94.6 98.3 98.9 96.8 97.2
EER Cooling Btu/hW 9.06 8.34 8.69 8.33 8.67 7.36 8.31 7.80
Pints/h 1.8 1.76 3.5 3.52 4.4 5.3 7.9 7.9
1 Moisture Removal
Liter/h (1.0) (1.0) (2.0) (2.0) (2.5) (3.0) (4.5) (4.5)
Fan Output
Optimized airflow design C.F.M 736 736 795 795 895 895 895 895
36% higher! Airflow rate (S-High)
(m3/h) (1,250) (1,250) (1,350) (1,350) (1,520) (1,520) (1,520) (1,520)
than current model mm 340×1,150×280 340×1,150×280 340×1,150×280 340×1,150×280 340×1,150×280 340×1,150×280 340×1,150×280 340×1,150×280
Net Dimensions Indoor
airflow 38%UP!*
Current model kg(lbs) 16.0 (35) 16.0 (35) 16.0 (35) 16.0 (35) 17.0 (37) 17.0 (37) 17.0 (37) 17.0 (37)
H×W×D
2 mm 650×830×320 830 × 900 × 330 650×830×320 830 × 900 × 330 914×970×370 914×970×370 1,290×900×330 1,290×900×330
Net Weight Outdoor
NEW model(+100mm) kg(lbs) 47.0 (103) 64.0 (141) 52.0 (114) 71.0 (157) 77.0 (169) 79.0 (174) 104 (229) 100.0 (220)
1
3 Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Connection Method Flare Flare Flare Flare Flare Flare Flare Flare
*:36 class :* NEW model
• Specifications are based on the following condition.
T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB.
12
12 • All air conditioners are single-phase types. 13
• Specifications and design subject to change without notice for further improvement. Please check with your dealer.
WALL MOUNTED TYPE WINDOW TYPE
15 m!
ASGA18/24FMTB-U Super power, Super quiet, and Super wave
Fan Speed Control Long louver provides wide airflow New long louver
AOGA18/24FMTBHU
Handy Type
SPECIFICATIONS SPECIFICATIONS
Set ASGA18FMTB-UZ ASGA24FMTB-UZ Indoor Unit AXGS18FHTA-U AXGS24APTH
Model No.
Model No. Indoor Unit ASGA18FMTB-U ASGA24FMTB-U Outdoor Unit - -
Outdoor Unit AOGA18FMTBHU AOGA24FMTBHU Capacity Class Btu/h 18,000 24,000
Capacity Class Btu/h 18,000 24,000 Power source V/ø/Hz 240-220/1/50 240-220/1/50
Power source V/ø/Hz 240-220 / 1 / 50 240-220 / 1 / 50 Energy Label 1 1
Energy Label 3 2 Cooling kW 5.30-5.30 6.50-6.35
Capacity
Cooling kW 5.40-5.40 7.15-7.15 Cooling Btu/h 18,100-18,100 22,200-21,700
Capacity T1
Cooling Btu/h 18,400-18,400 24,400-24,400 Input power Cooling kW 1.83-1.75 2.37-2.26
condition
T1 Input power Cooling kW 1.87-1.79 2.60-2.44 Current Cooling A 8.1-8.2 10.0-10.5
condition Current Cooling A 8.2-8.2 12.6-11.8 EER Cooling kW/kW 2.90-3.03 2.74-2.81
Power Factor Cooling % 95.0-99.2 86.0-94.0 Cooling kW 4.20 5.23
Capacity
EER Cooling kW/kW 2.89-3.02 2.75-2.93 Cooling Btu/h 14,300 17,800
T3
Cooling kW 4.70 6.10 Input power Cooling kW 2.18 2.80
Capacity condition
Cooling Btu/h 16,000 20,800 (230V) Current Cooling A 9.9 12.3
T3 Input power Cooling kW 2.15 2.90 EER Cooling Btu/hW 6.56 6.36
condition Current Cooling A 9.6 13.6 Pints/h 4.30 4.6
Moisture Removal
Power Factor Cooling % 97.4 92.7 Liter/h 2.0 2.6
EER Cooling Btu/hW 7.44 7.17 C.F.M 571-512 565-542
Airflow rate (High)
Pints/h 3.2 4.4 (m3/h) (970-870) (960-920)
Moisture Removal
Liter/h (1.8) (2.5) mm 455×670×710 455×670×710
Net Dimensions Indoor
C.F.M 600 676 kg(lbs) 56(124) 61(134)
Airflow rate (High) H×W×D
(m3/h) (1,020) (1,150) mm - -
Net Weight Outdoor
mm 320×998×238 320×998×238 kg(lbs) - -
Net Dimensions Indoor
kg(lbs) 13.0 (29) 13.0 (29) Refrigerant R410A R22
H×W×D
mm 650×830×320 650×830×320 • Specifications are based on the following condition.
Net Weight Outdoor
kg(lbs) 47.0 (104) 55.0 (121) T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
Refrigerant R410A R410A T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB.
• All air conditioners are single-phase types.
Connection Method Flare Flare
• Specifications and design subject to change without notice for further improvement. Please check with your dealer.
• Specifications are based on the following condition.
T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB.
14 • All air conditioners are single-phase types. 15
• Specifications and design subject to change without notice for further improvement. Please check with your dealer.
CASSETTE TYPE
(AUGA45FRTA-U+AOGA45FRTCSU) (AUGA54FRTA-U+AOGA54FRTCSU) 41
35 35
NEW NEW
Hi(dB)
Hi(m3/h)
AOGA18FBTBHU AOGA25FBTBHU AOGA30FBTCSU
OG 30 B CS AOGA36/45/54FRTCSU
Wired Type Wired Type Ʀ NEW model Ʀ Current model
SPECIFICATIONS
Ø7mm high density heat exchanger Set AUGA18FRTA-UX AUGA25FRTA-UX AUGA30FRTA-UX AUGA36FRTA-UX AUGA45FRTA-UX AUGA54FRTA-UX
Indoor Unit AUGA18FRTA-U AUGA25FRTA-U AUGA30FRTA-U AUGA36FRTA-U AUGA45FRTA-U AUGA54FRTA-U
Model No.
Outdoor Unit AOGA18FBTBHU AOGA25FBTBHU AOGA30FBTCSU AOGA36FRTCSU AOGA45FRTCSU AOGA54FRTCSU
Grelle UTG-UKGBUW UTG-UKGBUW UTG-UKGBUW UTG-UKGBUW UTG-UKGBUW UTG-UKGBUW
New DC fan motor
Capacity Class Btu/h 18,000 25,000 30,000 36,000 45,000 54,000
Power source V/ø/Hz 240-220 / 1 / 50 240-220 / 1 / 50 240-220 / 1 / 50 415-380 / 3 / 50 415-380 / 3 / 50 415-380 / 3 / 50
Energy Label 5 4 4 4 2 2
High efficient turbo fan Cooling kW 5.60-5.60 6.68-6.68 8.47-8.47 10.50-10.50 12.70-12.70 13.63-13.63
Capacity
Cooling Btu/h 19,100-19,100 22,800-22,800 28,900-28,900 35,800-35,800 43,300-43,300 46,500-46,500
T1 Input power Cooling kW 1.51-1.47 1.91-1.81 2.39-2.28 2.99-2.99 3.95-3.95 4.35-4.35
condition Current Cooling A 6.3-6.7 8.5-8.4 10.9-11.1 4.8-5.2 6.3-6.7 7.1-7.5
Seamless airflow louver
Power Factor Cooling % 99.9-99.7 93.6-97.9 91.4-93.4 86.7-87.4 87.2-89.6 85.2-88.1
EER Cooling kW/kW 3.71-3.81 3.50-3.69 3.54-3.71 3.51-3.51 3.22-3.22 3.13-3.13
Cooling kW 4.98 5.77 7.47 9.20 10.84 11.8
Capacity
Cooling Btu/h 17,000 19,700 25,500 31,400 37,000 40,200
T3 Input power Cooling kW 1.77 2.20 2.92 3.73 4.83 5.42
condition Current Cooling A 7.8 9.9 13.2 6.0 7.8 8.8
Uniform temperature
(230V)
Power Factor Cooling % 98.7 96.6 96.2 89.7 89.4 88.9
EER Cooling Btu/hW 9.60 8.95 8.73 8.42 7.40 7.42
air conditioning
Pints/h 2.8 4.0 4.0 5.1 8.4 9.8
Moisture Removal
Liter/h 1.6 2.3 2.3 2.9 4.8 5.6
C.F.M 677 677 1006 1177 2136 2136
Airflow rate (High)
Achieve a comfortable air conditioning spread to every corner (m3/h) (1150) (1150) (1710) (2000) (2100) (2100)
of the room by circular flow & wide vertical airflow. mm 246×840×840 246×840×840 288×840×840 288×840×840 288×840×840 288×840×840
Net Dimensions Indoor
ble ! H×W×D
kg(lbs) 24 (53) 24 (53) 26.5 (58) 29 (64) 29 (64) 29 (64)
forta
mm 650 × 830 × 320 830 × 900 × 330 914 × 970 × 370 1,290 × 900 × 330 1,290 × 900 × 330 1,290 × 900 × 330
Net Weight Outdoor
Com
kg(lbs) 50 (110) 63 (139) 77 (170) 103 (227) 102 (224) 107 (236)
Refrigerant R410A R410A R410A R410A R410A R410A
Connection Method Flare Flare Flare Flare Flare Flare
• Specifications are based on the following condition.
T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB.
16 • All air conditioners are single-phase types. 17
• Specifications and design subject to change without notice for further improvement. Please check with your dealer.
DUCT TYPE
ARGA30FMTA-U
25% up 3.42W/W
(11.71Btu/hW) External wiring equipment
32 3.41W/W
% up (11.64Btu/hW) High energy efficiency
Energy efficiency is improved drastically by new airflow design
and R410A refrigerant.
SPECIFICATIONS SPECIFICATIONS
Set ARGA18FMTA-UZ ARGA25FMTA-UZ ARGA30FMTA-UZ Set ARGA36FMTA-UZ ARGA45FMTA-UZ
Model No. Indoor Unit ARGA18FMTA-U ARGA25FMTA-U ARGA30FMTA-U Model No. Indoor Unit ARGA36FMTA-U ARGA45FMTA-U
Outdoor Unit AOGA18FBTAHU AOGA25FBTAHU AOGA30FBTASU Outdoor Unit AOGA36FRTASU AOGA45FRTASU
Capacity Class Btu/h 18,000 25,000 30,000 Capacity Class Btu/h 36,000 45,000
Power source V/ø/Hz 240-220/1/50 240-220/1/50 240-220/1/50 Power source V/ø/Hz 415-380/3/50 415-380/3/50
Cooling kW 5.20-5.20 6.45-6.45 8.30-8.30 Cooling kW 10.3-10.3 13.5-13.5
Capacity Capacity
Cooling Btu/h 17,800-17,800 22,000-22,000 28,400-28,400 Cooling Btu/h 35,000-35,000 46,000-46,000
T1 Input power Cooling kW 1.53-1.51 1.91-1.88 2.46-2.40 T1 Input power Cooling kW 3.01-3.01 4.0-4.0
condition Current Cooling A 6.5-7.0 8.5-8.8 11.1-11.3 condition Current Cooling A 5.0-5.2 6.5-6.9
Power Factor Cooling % 98.1-98.1 93.6-97.1 92.3-96.5 Power Factor Cooling % 83.8-87.9 85.6-88.1
EER Cooling kW/kW 3.40-3.44 3.38-3.43 3.37-3.46 EER Cooling kW/kW 3.42-3.42 3.38-3.38
Cooling kW 4.35 5.45 7.15 Cooling kW 9.2 11.9
Capacity Capacity
Cooling Btu/h 15,000 18,700 24,400 Cooling Btu/h 31,400 40,500
T3 Input power Cooling kW 1.80 2.24 2.91 Input power Cooling kW 3.79 5.00
T3
condition
Current Cooling A 8.0 10.1 13.5 condition Current Cooling A 6.2 8.1
(230V)
(400V)
Power Factor Cooling % 97.8 96.4 93.7 Power Factor Cooling % 88.2 89.1
EER Cooling Btu/hW 8.33 8.35 8.38 EER Cooling Btu/hW 8.28 8.10
Pints/h 1.6 1.9 2.3 Pints/h 3.0 3.3
Moisture Removal Moisture Removal
Liter/h 2.8 3.3 4.0 Liter/h 5.3 5.8
C.F.M 620 705 942 C.F.M 1,177 1,471
Airflow rate (High) Airflow rate (High)
(m3/h) (1,050) (1,200) (1,600) (m3/h) (2,000) (2,500)
mm 270×1,135×700 270×1,135×700 300×1,400×700 mm 300×1,400×700 300×1,400×700
Net Dimensions Indoor Net Dimensions Indoor
kg(lbs) 38.0 (84) 38.0 (84) 35.0(77) kg(lbs) 44.0 (97) 44.0 (97)
H×W×D H×W×D
mm 650×830×320 830×900×330 914×970×370 mm 1,290×900×330 1,290×900×330
Net Weight Outdoor Net Weight Outdoor
kg(lbs) 50.0 (110) 63.0 (139) 77.0 (169) kg(lbs) 100.0 (220) 102.0 (225)
Refrigerant R410A R410A R410A Refrigerant R410A R410A
Connection Method Flare Flare Flare Connection Method Flare Flare
• Specifications are based on the following condition. • Specifications are based on the following condition.
T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB. T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB. T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB.
• All air conditioners are single-phase types. * Air volume is given, when external static pressure is 60Pa. *
18 • Specifications and design subject to change without notice for further improvement. Please check with your dealer. • Specifications and design subject to change without notice for further improvement. Please check with your dealer. 19
DUCT TYPE
ARG 90E
Ø5mm large lambda heat exchanger High efficient large diameter sirocco fan
Airflow
4,300 m3/h
Static Pressure
200 Pa
(Max.300)
AOGA60FRTASU AOG90EPD3L
Wired Type Easy
Eas detachable drain pump Wired Type
(option)
SPECIFICATIONS SPECIFICATIONS
Set ARGA60FHTA-UZ Set ARG90ELC3Z
Model No. Indoor Unit ARGA60FHTA-U Model No. Indoor Unit ARG90ELC3
Outdoor Unit AOGA60FRTASU Outdoor Unit AOG90EPD3L
Capacity Class Btu/h 60,000 Capacity Class Btu/h 90,000
Power source V/ø/Hz 415-380/3/50 Power source V/ø/Hz 415-380/3/50
Cooling kW 15.2-15.2 Cooling 86,700-86,700
Capacity Btu/h
Cooling Btu/h 52,000-52,000 Heating -
Capacity
T1 Input power Cooling kW 4.47-4.47 Cooling 25.4-25.4
condition Current kW
Cooling A 7.5-7.8 Heating -
Power Factor Cooling % 82.9-87.1 Cooling 10.5-10.5
Input power kW
EER Cooling kW/kW 3.40-3.40 Heating -
Cooling kW 13.3 Cooling 2.42-2.42
Capacity EER kW/kW
Cooling Btu/h 45,300 Heating -
T3 Input power Cooling kW 5.47 Cooling 17.0-17.0
condition Current A
(400V) Current Cooling A 9.0 Heating -
Power Factor Cooling % 87.7 Pints/h 16.0
Moisture Removal
EER Cooling Btu/hW 8.28 Liter/h (7.5)
Pints/h 3.4 C.F.M 2537
Moisture Removal Airflow rate (High) Indoor
Liter/h 6.0 (m3/h) (4,300)
C.F.M 1,972 mm 450×1,550×700
Airflow rate (High) Net Dimensions Indoor
(m3/h) (3,350) kg(lbs) 85.0 (187)
H×W×D
mm 360×1,400×850 mm 1,380×1,300×650
Net Dimensions Indoor Net Weight Outdoor
kg(lbs) 67.0 (147) kg(lbs) 243.0 (535)
H×W×D
mm 1,290×900×330 Refrigerant R407C
Net Weight Outdoor
kg(lbs) 107.0 (235) Connection Method Flare(Small), Flange(Large)
Refrigerant R410A
Connection Method Flare • Cooling/Heating capacities are based on the following conditions.
Cooling Heating
• Specifications are based on the following condition.
Indoor temperature : 27°C DB / 19°C WB Indoor temperature : 20°C DB
T1 — Condition : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
Outdoor temperature : 35°C DB / (24°C WB) Outdoor temperature : 7°C DB/6°C WB
T3 — Condition : Indoor temperature of 29ÝCDB / 19ÝCWB, and outdoor temperature of 46ÝCDB / 24ÝCWB.
*Air volume of ARG90E models is given, when external static pressure is 20mm Aq (196Pa). ARG90E
* Air volume is given, when external static pressure is 60Pa. *
20 • Specifications and design subject to change without notice for further improvement. Please check with your dealer.
• Specifications and design subject to change without notice
for further improvement. Please check with your dealer.
21
SPLIT FEATURE SUMMARY
Adoption of environmentally-friendly,
Feature
energy-saving and high-performance air conditioners
Because refrigerant R22 depletes the ozone layer, we adopt new refrigerant R410A for our products. R410A is high-performance
and ODP is 0. In addition, high performance can be maintained even at high outdoor temperature.
Au
Au
M
Au
Do A
Di
oi
to
to
Co t i
Co h
Po
st
to
Pr
ub u t
Sw
st
Fr
m
-S
W
Au an s
rib
nn g
nn ir
og
-C
w
ur
Au
le o m
Up L o u
es
at
Sl
hu
ee
in
er
ha
to p e
u
e
ec D u
e c Du
ra
ee
ic
to
g
Sw a t
/D ve
kl
tL
fu
Re
m ed
ta c t
ta ct
ng
Model
A
n
Lo
y
Re
ow r s
lm
in i c
at
ou
m
bl
bl
Ti
Ti
Ti
eo
uv
g
st
ic
n
ov
e
ve
m
m
od
ve
er
ar
er
er
er
al
rs
e
s
r
ASGA18/24/30/36FUTA-U
ASGA18/24FUTB-U
ASGA30/36FETA-U
Refrigerant characteristics
ASGA18/24FMTB-U
AUGA18/25FRTA-U
ARGA18/25/30/36/45FMTA-U
ARGA60FHTA-U
R22 R410A
Ozone-depleting potential:0.05 Ozone-depleting potential:0
ARG90ELC3
Cool capacity:100 Cool capacity:141
WALL MOUNTED TYPE CASSETTE (COMPACT) TYPE CASSETTE TYPE DUCT TYPE
Super power
More capacity than old models
Double Swing Automatic Up/Down Swing Louvers under overload condition (52°C).
Complex action of flaps enables swing directions
Temperature rise prevention (Window Type: 60°C)
The up/down louvers automatically swing up and
both horizontally and vertically. down.
device (thermal protector) installed
Super low voltage operation
Our Hyper Tropical Compressor
can be operated even at low voltage.
Super Hi-EER
Auto-Shut Louvers Automatic Louvers Gas leak protection and low voltage protection
Highly energy efficiency
The auto shut louvers close or open automatically
OLP (Over Load Protection) device installed
The position of the louvers is set automatically
when the unit stops or starts. to match the operating mode. Super quiet
The Louvers can also be adjusted using the remote Select the lower noise level.
controller.
Distributed by :
http://www.fujitsu-general.com/
Copyright© 2008-2017 Fujitsu General Limited. All rights reserved.