You are on page 1of 9

PowerFlex 750-Series

Products with TotalFORCE


Control
Catalog Numbers 20G1, 20GE, 20J1, 20JE

Hardware Service Manual Original Instructions


Table of Contents

Power/LCL Filter Module Heatsink Fan Assembly


Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
Remove the Power or LCL Filter Module Heatsink Fan
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
Install the Power or LCL Filter Module Heatsink Fan
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
Torque Accuracy Module Replacement . . . . . . . . . . . . . . . . . . . . . . . . 365
Remove the Torque Accuracy Module . . . . . . . . . . . . . . . . . . . . . 365
Install the Torque Accuracy Module . . . . . . . . . . . . . . . . . . . . . . . 367
DC Bus Conditioner Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
Remove the DC Bus Conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . 370
Install the DC Bus Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . 372

Chapter 10
Frames 8…15 Wire Entry/Exit Wire Entry/Exit Bay Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Bay Components IP54/IP21, 400 mm Wide Door Vent Filters Replacement . . . . . . 375
IP54/IP21, 800 mm Wide Door Vent Filters Replacement . . . . . . 375
IP54/IP21, 400/800 mm Wide Door Vent Exhaust Fan and
Filter Assembly Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
Remove the IP54/IP21, 400/800 mm Wide Door Vent
Exhaust Fan and Filter Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . 375
Install the IP54/IP21, 400/800 mm Wide Door Vent
Exhaust Fan and Filter Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . 376
Thermal Switch Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Remove the Thermal Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Install the Thermal Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379

Chapter 11
Start Up After Repairs Before You Apply Power to the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . 381
Frames 5 and 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
Frames 7…15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
No-load DC Bus Voltage and Output Current Measurements . . . 388
Appendix A
System Schematics List of Schematic Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435

10 Rockwell Automation Publication 750-TG100C-EN-P - March 2021


Appendix A System Schematics

Figure 41 - PowerFlex 755T Frame 7 AC Precharge

400 Rockwell Automation Publication 750-TG100C-EN-P - March 2021


System Schematics Appendix A

Figure 42 - PowerFlex 755TL/TR Drive and PowerFlex 755TM Bus Supply (Frame 7)

Rockwell Automation Publication 750-TG100C-EN-P - March 2021 401


1 2 3 4 5 6 7 8
363
324

A A

IP54 TYPE1
531.3
459

B B

POWER ENTRY TOP


400 X 265
291

C C

332
D 175.4 D

DISPLAY CENTER OF 2292


HUMAN INTERFACE MODULE

1616.3
1247.1
E E

F F

130
148 800
708.5
103 715

G G
0 535
DETAIL A

201 132
ALL UNDIMENSIONED GEOMETRIES CONFIDENTIAL AND PROPRIETARY INFORMATION.
0 ARE CONTROLLED BY THE CAD THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY
INFORMATION OF ROCKWELL AUTOMATION, INC. AND MAY
H MODEL. IN CASE OF DIMENSION
DISCREPANCY, CAD MODEL
NOT BE USED, COPIED OR DISCLOSED TO OTHERS, EXCEPT
WITH THE AUTHORIZED WRITTEN PERMISSION OF ROCKWELL H
AUTOMATION, INC.
OVERRIDES.
DATE:08-23-2021 SHEET 1 OF 1

DESCRIPTION
THIRD ANGLE PROJECTION
STANDARD_PF755TL_TR_FRAME-6 SIZE DIR VER
0
735

D 10006347826 00
SEE DETAIL A CREATED BY: TPS1 CHANGED BY:

1 2 3 4 5 6 7 8
MODICACIÓN DEL SISTEMA DE MANDO Y
SEÑALIZACIÓN
0 1 2 3 4 5 6 7 8 9

F26_006 yhonatan

Soluciones en Control Industrial


y de Procesos S.A.C

Cliente Minera Poderosa S.A.


Designación de instalación Tablero de Fuerza con Variador 755T
Número de diseño 04-2020-PODEROSA-TF-V1.0

Fabricante Soluciones en Control Industrial


y de Procesos S.A.C

Nombre de proyecto Tablero Para Ventilador Tensión de Fuerza 460 VAC


Producto PowerFlex Series 750 Tensión de Control 110 VAC
Lugar de instalación Minera Poderosa S.A. Tipo de Armario Tablero Autosoportado
Responsable del proyecto Ing. Daniel Novario Vargas Grado de Protección IP65

Modificado 29/01/2021 Número de páginas 3

Fecha 29/01/2021 Soluciones en Control Industrial Tablero de Fuerza con Variador 755T =
Diseñado D. Natividad y de Procesos S.A.C Hoja de título / portada +
Revisado 04-2020-PODEROSA-TF-V1.0 Nº Plano 1
Cambio Fecha Nombre Aprobado Cantidad 3
0 1 2 3 4 5 6 7 8 9

T1.L1 T1.L2

1 2

-T2
220VAC/110VAC 3 4

-F3
2

11
-S1
Paro 12
Emergencia

Automático
Run Fwd

Run Rev

Manual
0
13 23 3 13 23
-SL2 -SL1
24 Selector 14 24
14 4
2.7 2.8
-U1.2.R0C -U1.2.R1C
Contacto de Falla
11 21 11 3
1 2.7 2.7 2.8
-KA2 -KA2 -KA3 -S4 -U1.2.R0NO -U1.2.R0NC -U1.2.R1NO
/2.4 /2.4 Reset -S3
14 24 14 12 4
Pulsador 2
Paro

3 13

-U1 -S2 -KA1


Pulsador 4 /2.4 14
Tarjeta E/S-Módulo DI +24V Di 0 Di 1 Di 2 Di 3 Di 4 Di 5 Arranque
20-750-2262D-2R

PowerFlex 750 Series I/O Option Module: TB1

A1 A1 A1 x1 x1 x1
Ai0+ Ai0- 10VC +10V 24VC Di C
-KA2 -KA1 -KA3 -H1 -H2 -H3
Arranque A2 Arranque A2 Arranque A2 Indicador x2 Indicador x2 Indicador x2
Enclavamiento Automático Luminoso de Luminoso de Luminoso de
Arranque Paro Falla

-P1
x1 x3

x2 -U1.2
Tarjeta E/S-Módulo DO PowerFlex 750 Series I/O Option Module: TB2
20-750-2262C-2R

11 14 /2.1 13 14 /2.5 14 R0NO R0C R0NC R1NO R1C R1NC


11 /2.2
21 24 /2.2 12

2.6 2.6 2.6 2.7 2.7


-U1.2.R0NO -U1.2.R0C -U1.2.R0NC -U1.2.R1NO -U1.2.R1C

Fecha 29/01/2021 Soluciones en Control Industrial Tablero de Fuerza con Variador 755T =
Diseñado D. Natividad y de Procesos S.A.C Esquema de Control Variador +
Revisado 04-2020-PODEROSA-TF-V1.0 Nº Plano 2
Cambio Fecha Nombre Aprobado Cantidad 3
0 1 2 3 4 5 6 7 8 9

24
OFF
START
MAN. AUT. FOR. REV.

26 26

5K
STOP
0K 10K

26

EMERG. STOP RESET FAULT

Fecha 29/01/2021 Soluciones en Control Industrial Tablero de Fuerza con Variador 755T =
Diseñado D. Natividad y de Procesos S.A.C Layout Externo +
Revisado 04-2020-PODEROSA-TF-V1.0 Nº Plano 3
Cambio Fecha Nombre Aprobado Cantidad 3