1: Title Page 38: VUV-5 Sequence Of Operation
2: Table of Contents 39: Water Source Heat Pumps
3: Symbol Legend 40: Water Source Heat Pump Sequence
4: Abbreviation/Installation Notes 41: Radiant Ceiling Panel Loop Control
5: Cable Specification Chart 42: Cabinet Unit Heaters
6: Installation Details 1 43: Exhaust Fans Serving Pre-School Wing
7: Installation Details 2 44: Exhaust Fans Serving Northwest Rooms
8: Installation Details 3 45: Additional Exhaust Fans
9: Installation Details 4 46: Summary Bill of Materials
10: Installation Details 5
11: Network Riser
12: LGR & OAT Controller Wiring
13: Heat Pump Loop System Schematic
14: Heat Pump Loop System Controller Wiring
15: Heat Pump Loop System Sequence
16: Multi-Zone MZ-1 Control
17: Multi-Zone MZ-1 Sequence Of Operation
18: Multi-Zone MZ-1 Zone Control
19: AHU-1 Control
20: AHU-1 Sequence Of Operation
21: AHU-1 Sequence Continued
22: AHU-2, 3 & 4 Control
23: AHU-2, 3 & 4 Sequence Of Operation
24: AHU-5 & Sequence Of Operation
25: AHU-5 Sequence Continued
26: AHU-5 VAV Terminal Unit
27: RTU-1 Control
28: RTU-1 Sequence of Operation
29: RTU-1 Sequence of Operation Continued
30: RTU-2 Control
31: RTU-2 Sequence of Operation
32: RTU-2 Sequence of Operation Continued
Elementary School
33: Supply Fan SF-1 With Reheat Coil
Michigan 48xxx
34: Supply Fan SF-1 Sequence of Operation Metro Environmental, Inc.
35: VUV-1, 2, 3 & 4 Control Table of Contents
36: VUV-1, 2, 3 & 4 Sequence Of Operation REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
CHECKED BY : TS
2 of 46
Symbol Notes
LO
1 120 VAC POWER TO PANELS AND CONDUIT BY DIV.
120 VAC 16. POWER SUPPLY DEDICATED PER PANEL.
DX
120 VAC UPS POWER AND CONDUIT TO FIELD
HI 120 VAC MODULE PANELS (FMPs) BY CONTROLS
Parallel Blade 2
DX Cooling Coil High Static Pressure Switch UPS INSTALLATION SUBCONTRACTOR. POWER SUPPLY
Damper with Actuator Pump DEDICATED PER PANEL.
AUTOMATED LOGIC
Exhaust Fan
120 VAC UPS POWER AND CONDUIT TO FIELD
RSBASIC Zone 120 VAC MODULE PANELS (FMPs) BY DIV. 16. ONE DEDICATED
3
Temperature Sensor UPS UPS CIRCUIT PER FMP. THESE CIRCUITS ARE
INTENDED FOR MISSION CRITICAL OPERATIONS.
Manual Valve ...--.-.
-..--|-.:
Current :::|-||--.
V. ADJ
Electrical Connection
Steam Coil Immersion Temperature INSTALLATION DETAILS REFERENCE (REFER TO THE
DM-1
Sensor w/ Well INSTALLATION DETAILS PAGES FOR THE APPROPRIATE DETAIL)
T
PAGE NOTE REFERENCE (THE NUMBER IN THE
Zone Temperature Sensor Power Supply 1 OVAL REFERS TO THE APPROPRIATE NOTE
NUMBER IN THE NOTES TEXT BLOCK)
Air Cooled Chiller
PANEL NOMENCLATURE (THE FIRST # IS THE LANGATE NUMBER
Piping Connection FMP # - #
Duct Humidity Sensor AND THE SECOND NUMBER IS THE SEQUENTIAL PANEL NUMBER)
Humidifier
T/H
Alarm Horn
Combination Zone VAV Box
FreezeStat
Temperature/Humidity Sensor
Hot Water Boiler
Filter
Occupied
T STM
Smoke Detector PIU
COOL WARM
Alarm Light
Logistat Plus Room
Temperature Sensor Steam Converter
Air Flow Station
Elementary School
1 2 3 4 5 6 Michigan 48xxx
75 HI LO
Detector
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
Logistat Pro Room Opposed Blade
Temperature Sensor Damper with Actuator DRAWN BY : TL
Relay
HI LO
CHECKED BY : TS
A30010 18/4 AWG TWISTED, PLENUM RATED, MAGNUM CABLE CORPORATION I/O WIRING BLACK *Abbreviation is specific for the Logistat device. Do not confuse
8 002380 UNSHIELDED PHONE: 800.421.0820 CLASS 2 WIRING ONLY WHITE with the switch (SW) abbreviation on the Abbreviation/Installation
OR EQUIVALENT WEB: http://www.magnumcable.com RED
Notes page.
GREEN
A3ARC156 22/2 AWG TWISTED/SHIELDED PLENUM MAGNUM CABLE CORPORATION ARC156, NET+ WHITE
9
043006 RATED PHONE: 800.421.0820 UNET COMMUNICATION (NO POWER WIRE) NET- BLACK
OR EQUIVALENT WEB: http://www.magnumcable.com WITH GREEN JACKET
A30004 22/4 AWG TWISTED, UNSHIELDED FOR MAGNUM CABLE CORPORATION LOGISTAT, RS, RS PLUS, RS PRO, RS PRO F LOGISTAT RS / Rnet BLACK
10 0043830 LOGISTAT, SHIELDED FOR RS, RS PLUS, PHONE: 800.421.0820 GND GRD BLACK
Rnet + WHITE
WHITE Cable Jacket Colors
OR EQUIVALENT RS PRO, RS PRO F, PLENUM RATED, WEB: http://www.magnumcable.com TEMP GREEN
STRANDED SW Rnet - GREEN RED 24vac = Gray
LS5V +12v RED WITH WHITE JACKET
Comm = Green
A30111 18/4 AWG TWISTED/SHIELDED, DOUBLE MAGNUM CABLE CORPORATION RS ZONE SENSOR PAIR1
60100 PAIR, PLENUM RATED PHONE: 800.421.0820 12V RED AI = Yellow
11 OR EQUIVALENT WEB: http://www.magnumcable.com GND BLACK
PAIR 2
AO = Tan
NET+ WHITE DI = Orange
NET- GREEN
WITH WHITE JACKET DO = Violet
A30101 22/4 AWG TWISTED/SHIELDED, DOUBLE MAGNUM CABLE CORPORATION PORTAL 4 WIRE COMMUNICATION EIA-485-4W EIA-232-4W PAIR 1
004340 PAIR, PLENUM RATED PHONE: 800.421.0820 TX+ TX RED
12
OR EQUIVALENT WEB: http://www.magnumcable.com TX- RX BLACK
PAIR 2
RX+ DTR/RTS WHITE
RX- DCD/CTS GREEN
WITH WHITE JACKET
A3U-LINE (1) PAIR 14AWG FOR POWER & (1) PAIR MAGNUM CABLE CORPORATION UNET (WITH POWER WIRE) PAIR 1 (18 GA)
007960+043006 22AWG FOR COMMUNICATIONS PHONE: 800.421.0820 24 VAC RED
13 OR EQUIVALENT (PLENUM RATED) WEB: http://www.magnumcable.com GND GREEN
PAIR 2 (22 GA)
UNET+ WHITE
UNET- BLACK
WITH PINK JACKET
A3ZNB-156 (1) PAIR 14AWG FOR POWER & (1) PAIR MAGNUM CABLE CORPORATION ARC156 (WITH POWER WIRE) PAIR 1 (14 GA)
007960+043006 22AWG FOR COMMUNICATIONS PHONE: 800.421.0820 24 VAC RED
14 OR EQUIVALENT (PLENUM RATED) WEB: http://www.magnumcable.com GND GREEN
PAIR 2 (22 GA)
NET+ WHITE
NET- BLACK
WITH GREEN JACKET
Elementary School
A50089BLU 24/8 AWG CAT 5 ENHANCED, PLENUM MAGNUM CABLE CORPORATION ETHERNET NETWORK COMMUNICATIONS PR.1 WHITE/BLUE & BLUE Michigan 48xxx
15 555619 RATED 100MHz PHONE: 800.421.0820 PR.2 WHITE/ORANGE & ORANGE
OR EQUIVALENT WEB: http://www.magnumcable.com PR.3 WHITE/GREEN & GREEN Metro Environmental, Inc.
PR.4 WHITE/BROWN & BROWN
WITH BLUE JACKET Cable Specification Chart
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
Notes: DRAWN BY : TL
1. If a wire substitution is made consult ALC for approval.
CHECKED BY : TS
5 of 46
RIB-1 RIB- OAT-
RELAY IN A BOX - PILOT SERIES (RIBU24C-FA) 2 RELAY IN A BOX - PILOT SERIES (RIBU1C & RIBU2C) 1 OUTDOOR AIR TEMPERATURE SENSOR
OUTSIDE
BUILDING
RELAY IN A BOX RELAY IN A BOX
LED STATUS INDICATOR
LED STATUS INDICATOR CONDUIT SLEEVE,
SCREW HOLES SCREW HOLES FIRE PROOF
(2) TYP. (2) TYP. WIRE NUT PENETRATION
LOCKNUT LOCKNUT JUNCTION BOX
1/2" CONDUIT NIPPLE 1/2" CONDUIT NIPPLE MOUNTED FLUSH TO
INSIDE WALL
BLUE (NC) BLUE (NC) NORTH
YELLOW (C) YELLOW (C) SEAL PENETRATION
RELAY RELAY #1
ORANGE (NO) ORANGE (NO) WITH FIRE SEAL
GRAY (NC)
RELAY COIL DRIVE DATA RELAY #2 PURPLE (C)
WHITE/YELLOW COMMON (IF RIBU2C) BROWN (NO)
COIL WHITE/BLUE 24VAC/DC IN CONDUIT
RELAY COIL DRIVE DATA
WHITE/YELLOW COMMON
WHITE/BLUE 10-30 VAC/DC
RELAY #1 WHITE/BLACK 120 VAC
WHITE/BROWN 208-277 VAC AI TO MODULE
TERMINAL STRIP
WHITE/PURPLE COMMON
RELAY #2 GRAY/WHITE 10-30 VAC/DC
(IF RIBU2C) WHITE/RED 120 VAC
WHITE/ORANGE 208-277 VAC
MOUNTING INSTRUCTIONS
1. A SMALL WEEP HOLE (1/8" OR LESS) MUST BE DRILLED INTO THE BOTTOM (PROBE) SIDE OF THE ENCLOSURE TO ALLOW ANY
CONDENSATION WITHIN THE ENCLOSURE TO ESCAPE. CAUTION MUST BE TAKEN TO AVOID DAMAGING THE LEAD WIRES AND
ANY ELECTRICAL CONNECTIONS WHEN DRILLING THE WEEP HOLE.
MOUNTING INSTRUCTIONS: MOUNTING INSTRUCTIONS: 2. ATTACH THE MOUNTING TABS TO OPPOSITE CORNERS OF THE BELL BOX WITH SELF TAPPING SCREWS.
THE RIB PILOT SERIES HAS A 1/2" NPT NIPPLE FROM WHICH ALL WIRES EXIT. THE RIB PILOT SERIES HAS A 1/2" NPT NIPPLE FROM WHICH ALL WIRES EXIT. 3. MOUNT THE OUTSIDE AIR UNIT OUT OF DIRECT SUNLIGHT WITH THE PVC SENSOR COVER POINTING DOWN. MOUNT THE
SENSOR ON THE WALL WITH THE NORTH MOST EXPOSURE.
JUNCTION BOX OR EQUIPMENT MOUNTING INSTRUCTIONS JUNCTION BOX OR EQUIPMENT MOUNTING INSTRUCTIONS 4. TERMINATE THE UNIT AS SHOWN ABOVE. BE SURE TO INCORPORATE A "J-LOOP" INTO THE TERMINATION. A "J-LOOP" IS
REMOVE A 1/2" CONDUIT KNOCKOUT IN THE EQUIPMENT, INSERT THE WIRES & NIPPLE THROUGH THE HOLE, TIGHTEN THE REMOVE A 1/2" CONDUIT KNOCKOUT IN THE EQUIPMENT, INSERT THE WIRES & NIPPLE THROUGH THE HOLE, TIGHTEN THE FORMED BY POINTING THE WIRE NUTS OF A TERMINATION UP CREATING A "J" IN THE CABLE IN ORDER TO REDUCE THE
LOCKNUT, AND CONNECT THE WIRES. LOCKNUT, AND CONNECT THE WIRES. PROBABILITY OF CONDENSATION COLLECTING IN THE WIRE NUT.
5. ATTACH THE COVER. MAKE SURE THE GASKET SEALS ON ALL SIDES. DO NOT OVER TIGHTEN THE COVER. IF
SURFACE MOUNTING INSTRUCTIONS SURFACE MOUNTING INSTRUCTIONS OVER TIGHTENED, THE BELL BOX WILL CUT THE GASKET AND ALLOW MOISTURE TO ENTER THE ENCLOSURE.
FASTEN THE RELAY TO THE DESIRED LOCATION USING THE (2) SCREW HOLES IN THE HOUSING. FASTEN THE RELAY TO THE DESIRED LOCATION USING THE (2) SCREW HOLES IN THE HOUSING. 6. SEAL ALL CONDUIT HOLES WITH THE PLUGS PROVIDED AND AN APPROPRIATE SILICON SEALANT.
NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE
CONDUIT SHOULD NOT EXCEED 18". CONDUIT SHOULD NOT EXCEED 18". CONDUIT SHOULD NOT EXCEED 18".
RTS- JCK-
2 ROOM TEMPERATURE SENSOR - RS SENSORS 1 MINI-JACK TX-5e MODULAR JACK JB-1 END DEVICE TERMINATION BOX DETAIL
COLOR CODE
(IF USING A, REFER TO THE COLOR CODE ON ROW 3 & 4)
(IF USING B, REFER TO THE COLOR CODE ON ROW 1 & 2)
TO MODULE
COLUMN
CONDUIT FOR RELATED
1 2 3 4
END DEVICE WIRING ONLY
ROW 1
B
ROW 2
ROW 3
A
AUTOMATED LOGIC
ROW 4
B
MODULAR JACK
A
RETENTION SLOT CONTACTS
(2) CONDUCTOR WIRE (BEHIND WALL)
ROOM TEMP. SENSOR ROW COLOR CODE DESIGNATION
WALL
RED
Rnet+
Rnet-
+12V
TO MODULE TO MODULE
TERMINAL STRIP TERMINAL STRIP AI TO MODULE
TERMINAL STRIP
DUCT
COPPER RADIUS
DUCT AVERAGING MOUNTING CLIPS
DUCT
TEMPERATURE SENSOR PROVIDED WITH SENSOR
DUCT TEMPERATURE DUCT
ENCLOSURE
SENSOR ENCLOSURE
DP TRANSMITTER
WIRE NUT
WIRE NUT 1 in
AI TO MODULE 2.5 in
5 in
TERMINAL STRIP 10 in
4-20mA
- - A
AI TO MODULE + + B TO MODULE
TERMINAL STRIP ZERO TERMINAL STRIP
5V 10V
mA
Volts
BI/UN
MOUNTING INSTRUCTIONS
MOUNTING INSTRUCTIONS 1. SECURE THE MOUNTING FLANGE TO THE DUCT USING SELF-TAPPING SHEET METAL SCREWS.
1. DRILL A 3/8" HOLE IN THE DUCT WALL FOR THE PROBE. 2. INCORPORATE A "J-LOOP" INTO THE TERMINATION. A "J-LOOP" IS FORMED BY POINTING THE WIRE NUTS OF A TERMINATION
MOUNTING INSTRUCTIONS
2. SECURE THE MOUNTING FLANGE TO THE DUCT USING SELF-TAPPING SHEET METAL SCREWS (NOT PROVIDED). UP CREATING A "J" IN THE CABLE IN ORDER TO REDUCE THE PROBABILITY OF CONDENSATION COLLECTING IN THE WIRE
1. DRILL A 3/8" HOLE IN THE DUCT WALL FOR THE STATIC PRESSURE PROBE.
3. TERMINATE THE UNIT AS SHOWN ABOVE. NUT.
2. SECURE THE DEVICE TO THE DUCT USING SELF-TAPPING SHEET METAL SCREWS.
4. BE SURE TO USE SEALANT FILLED CONNECTIONS AND INCORPORATE A "J-LOOP" INTO THE TERMINATION. A "J-LOOP" IS 3. EVENLY SPACE THE AVERAGING ELEMENT ACROSS THE AIR FLOW.
3. INSTALL STATIC PRESSURE PROBE HORIZONTALLY SO THE ENCLOSURE IS IN A VERTICAL PLANE AND THE NAMEPLATE AND
FORMED BY POINTING THE WIRE NUTS OF A TERMINATION UP CREATING A "J" IN THE CABLE IN ORDER TO REDUCE THE 4. SECURE THE AVERAGING ELEMENT USING RADIUS MOUNTING CLIPS.
LETTERING IS IN AN UPRIGHT POSITION.
PROBABILITY OF CONDENSATION COLLECTING IN THE WIRE NUT. 4. CONNECT TRANSMITTER TO CONTROL SYSTEM.
5. SEAL ALL CONDUIT HOLES WITH THE PLUGS PROVIDED AND APPROPRIATE SILICON SEALANT NOTE: WHEN FORMING THE AVERAGING ELEMENT TO THE DESIRED SHAPE, BE SURE THE BEND DIAMETER IS GREATER THAN
5. CONFIGURE ALL JUMPERS AND SWITCHES TO APPROPRIATE POSITIONS.
6". DO NOT USE SENSOR BOX AS A JUNCTION BOX FOR OTHER WIRING.
NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE
NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT
CONDUIT SHOULD NOT EXCEED 18". CONDUIT SHOULD NOT EXCEED 18".
TO END DEVICE FROM JUNCTION BOX. FLEXIBLE CONDUIT SHOULD NOT EXCEED 18".
DAMPER SHAFT
High
(with filter) DI TO MODULE
Flow
TERMINAL STRIP
L
CAUTION:
To Reduce the Risk of Fire
or Electric Shock, Do Not
Low
Interconnect the Outputs of
Different Class 2 Circuits.
CAUTION:
Rnet
LogiStat
POWER
Made in USA U.S. Patent No. 6,715,690 B2
This product was designed
to be mounted inside the
IN-2 0-5Vdc SOURCE
building envelope. Warranty
voided if mounted outside.
IN-1
Therm/dry
0-5Vdc
INPUT JUMPERS (2) CONDUCTOR WIRE
Damper release button inside
Therm/dry
Format N
Short pins
LStat =
or IN-3 =
ADDRESS IN CONDUIT
NO
ARC156
ZN341v+ MSTP
Batt
2 3 23
CR2032 1 4
456
901
10's 0 5
9 6 78
8 7
+ -
MSTP Baud 1
2 3
4
23
MOUNTING BRACKET
90 1
456
1's 0 5
9 6 78
9600 19.2k 38.4k 76.8k 8 7
On
Error 4
2
4
3
Run
2
1
3
Power for D.O.s
Power
O
N
Outputs
24V Max,
1A Max
AO: 0-10 Vdc Inputs 3 & 4
ZASF
Rx Tx
Class 2
24Vac, 50-60 Hz
14VA, 0.58A
26Vdc, 0.1A, 3W
Sense
+12V
Rnet- CURRENT SWITCH COPPER RADIUS
FAN
5mA Max Inputs 1 & 2 Therm, dry Use Copper
Rnet+
24V ac
Shield
Net +
Rnet +
Access
Net -
Rnet -
DO-2
DO-3
DO-1
BUS
+12V
AO-1
IN-1
Gnd
IN-2
Gnd
Gnd
IN-3
IN-4
LED
Gnd
Gnd
CONDUCTOR
MOUNTING INSTRUCTIONS - ZN141v+ & ZN341v+
1. PLACE THE MODULE HORIZONTALLY ON THE VAV BOX BY FEEDING THE DAMPER SHAFT THROUGH THE SHAFT SLOT. Or Pump TO SAFETY CIRCUIT OF
N.C. N.O.
DI TO MODULE
CAUTION: DO NOT POSITION THE MODULE SO THE SHAFT SLOT IS IN THE UPPER RIGHT OF THE MODULE. THIS POSITION MAY CONTROLLED EQUIPMENT TERMINAL STRIP
CAUSE CONDENSATION FROM THE VAV SHAFT TO DRIP ON THE ELECTRONIC COMPONENTS OF THE ZN-LINE CONTROLLER.
2. INSERT A MOUNTING SCREW INTO THE STABILIZING SLOT AND TIGHTEN IT TO SECURE THE MODULE.
3. LIGHTLY PULL OUT 2 PLASTIC TABS ON RIGHT SIDE OF CONTROLLER TO REMOVE TETHERED PLASTIC COVER. MOUNTING INSTRUCTIONS
4. ROTATE THE DAMPER SHAFT TO THE FULL CLOSED POSITION. 1. LOW LIMIT MUST BE MOUNTED IN A VERTICAL POSITION. FOR THE LOW LIMIT SWITCH AND CAPILLARY TUBES, AVOID
5. LOCATE THE DAMPER CLUTCH BUTTON ON THE CONTROLLER, PUSH AND ROTATE THE DRIVE IN THE SAME FULL DIRECTION LOCATIONS SUBJECT TO EXCESSIVE VIBRATION.
AS THAT TO CLOSE THE DAMPER. MOUNTING INSTRUCTIONS
2. ON MANUAL RESET MODELS, POSITION THE CONTROL TO PERMIT CONVENIENT ACCESS TO THE RESET BUTTON.
6. TIGHTEN THE (2) NUTS ON THE CLAMP USING A 10MM WRENCH OR SOCKET USING 6-8 FT LB OF TORQUE. 1. ENSURE POWER CONDUCTOR TO BE MONITORED IS DISCONNECTED AND LOCKED OUT FROM THE POWER SOURCE.
3. USE THE MOUNTING HOLES IN THE REAR OF THE CASE FOR FLUSH MOUNTING TO THE DUCT OR FLAT SURFACE.
7. PUSH THE DAMPER CLUTCH BUTTON AGAIN AND ROTATE THE DAMPER TO THE FULL OPEN POSITION. 2. INSTALL THE ADJUSTABLE MOUNTING BRACKET TO THE BACK OF THE MOTOR CONTROL CENTER/STARTER. THE SENSOR
4. DRILL A 3/8" HOLE IN THE DUCT WALL FOR THE CAPILLARY ELEMENT.
8. RE-ATTACH THE TETHERED PLASTIC COVER BY “HOOKING” ON LEFT SIDE AND SNAPPING ON RIGHT SIDE. MAY BE LOCATED AT ANY POINT ON THE CONDUCTOR BETWEEN THE MOTOR AND THE MOTOR STARTER.
5. SECURE THE MOUNTING FLANGE TO THE DUCT USING SELF-TAPPING SHEET METAL SCREWS.
3. ALIGN TO PERMIT THE CONDUCTOR TO FIT THROUGH THE HOLE. SLIDE THE CONDUCTOR THROUGH THE CENTER HOLE IN
6. INSTALL CAPILLARY ELEMENT IN A HORIZONTAL SERPENTINE PATTERN ACROSS THE DUCT AS SHOWN ON THE ABOVE
TUBING INSTALLATION INSTRUCTIONS TO STANDARD FLOW CROSS THE SENSOR AND CONNECT THE CONDUCTOR TO THE LUGS ON THE MOTOR STARTER.
DETAIL
USE ¼" POLYETHYLENE OR VINYL TUBING. LEAVE SLACK IN THE TUBING. NOTE: LOW AMPERAGE (<1.5A) AND HIGH AMPERAGE (>200A) APPLICATIONS MAY REQUIRE SPECIAL INSTALLATION:
SO IT IS EXPOSED TO AREAS TO PROTECT THE COIL. DO NOT KINK OR APPLY EXCESSIVE FORCE TO THE CAPILLARY
1. CONNECT THE HI PRESSURE PORT TO THE HIGH OR VELOCITY PRESSURE PORT ON THE FLOW CROSS. A. LOW AMPERAGE - TO PROVIDE ADEQUATE CURRENT, WRAP CONDUCTOR THROUGH THE CENTER HOLE AND AROUND
ELEMENT.
2. CONNECT THE LO PRESSURE PORT TO THE LOW OR STATIC PRESSURE PORT ON THE FLOW CROSS. THE SENSOR BODY TO PRODUCE MULTIPLE TURNS AND INCREASE CURRENT FLOW. EACH PASS THROUGH THE
7. INSTALL RADIUS MOUNTING CLIPS AT EVERY BEND.
TRANSDUCER INCREASES THE AMPERAGE BY THE ORIGINAL VALUE.
8. THE LOW TEMPERATURE LIMIT SWITCH MUST BE MOUNTED IN A MANNER WHICH PROVIDES PROTECTION TO THE ENTIRE
STANDARD WIRING & CONFIGURATION INSTRUCTIONS B. HIGH AMPERAGE - CURRENT FLOWS IN EXCESS OF 200A REQUIRE THE USE OF AN APPROPRIATELY SIZED EXTERNAL
SURFACE OF COIL WITH A MAXIMUM OF 1.5' BETWEEN CAPILLARY PASSES. USE MULTIPLE DEVICES IF COIL IS NOT
1. TIE THE COMMUNICATION WIRING SHIELD TOGETHER AND ISOLATE WITH TAPE OR HEAT SHRINK. CURRENT TRANSFORMER (CT). INSTALL THE EXTERNAL CT ON THE CONDUCTOR AND RUN THE CT SECONDARY WIRE
SUFFICIENTLY COVERED.
2. MAINTAIN POLARITY WHEN MULTIPLE DEVICES ARE CONNECTED TO A COMMON POWER SUPPLY. THROUGH CURRENT SENSOR.
9. THE CONTROL ENCLOSURE SHALL BE COMPLETELY MOUNTED ON THE EXTERIOR OF THE AIR HANDLING UNIT AND THE
3. SET THE DEVICE ADDRESS WITH THE ROTARY SWITCHES. CAUTION: CT's CAN CONTAIN HAZARDOUS VOLTAGES. INSTALL CT's IN ACCORDANCE TO MANUFACTURERS'
CONTROL ENCLOSURE SHALL NOT BE MOUNTED LOWER THAN THE CAPILLARY TUBING.
4. POSITION JUMPERS ON THE INPUT POINTS TO CONFIGURE THE SIGNAL TYPE. SPECIFICATIONS AND INSTRUCTIONS.
NOTE: DO NOT USE SENSOR BOX AS A JUNCTION BOX FOR OTHER WIRING.
NOTE: MODULES SHOULD BE MOUNTED INDOORS IN A DRY, CLEAN ENVIRONMENT FREE OF CORROSIVE FUMES. A PROTECTIVE 4. WIRE AS SHOWN ABOVE.
ENCLOSURE MUST BE USED WHEN MOUNTED OUTDOORS. THE MODULES ARE CLASS 2 DEVICES (>30VAC). TAKE NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM
NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE
APPROPRIATE ISOLATION MEASURES WHEN MOUNTING IN A CONTROL PANEL WHERE CLASS 1 WIRING OR DEVICES ARE
PRESENT. CONDUIT SHOULD NOT EXCEED 18".
JUNCTION BOX. FLEXIBLE CONDUIT SHOULD NOT EXCEED 18". 7 of 46
AF SERIES NF SERIES ONLY
DM-1 DAMPER MOTOR - BELIMO AF SERIES ACTUATORS IF MORE TORQUE IS NEEDED, A DM-2 DAMPER MOTOR - BELIMO LF & NF SERIES ACTUATORS IF MORE TORQUE IS NEEDED, A
SECOND ACTUATOR MAY BE MOUNTED SECOND ACTUATOR MAY BE MOUNTED ACTUATOR
TO THE SHAFT USING THE ZG-102 ACTUATOR TO THE SHAFT USING THE ZG-102
RETAINING CLIP RETAINING CLIP
MULTIPLE MOUNTING BRACKET MULTIPLE MOUNTING BRACKET
UNIVERSAL CLAMP UNIVERSAL CLAMP
JUNCTION BOX & JUNCTION BOX &
FLEXIBLE CONDUIT FLEXIBLE CONDUIT
PROVIDED BY PROVIDED BY
INSTALLER INSTALLER
ANTI-ROTATION STRAP ANTI-ROTATION STRAP
2 MODULATING MOTOR
MODULATING MOTOR APPROPRIATE
1 2 + HOT
2 + HOT WIRING TO MODULE
2 3 1 COMMON
APPROPRIATE 1 COMMON TERMINAL STRIP
1 5 3 Y1 INPUT,0-10V
WIRING TO MODULE 3 Y1 INPUT,0-10V POWER AND
3 5 U OUTPUT 2-10V 5 U OUTPUT 2-10V
TERMINAL STRIP SIGNAL WIRING IN
5
FLEXIBLE CONDUIT 1
TWO POS. MOTOR TWO POS. MOTOR
1 NOTE: IF THE ACTUATOR IS 2 2 + HOT (SWITCHED)
POWER AND SIGNAL WIRING IN 2 + HOT (SWITCHED) EQUIPPED WITH END APPROPRIATE
2 S1 1 COMMON
FLEXIBLE CONDUIT. ZG-102 MOUNTING 1 COMMON SWITCHES OR POSITION WIRING TO MODULE
APPROPRIATE S1 S2 S1 COMMON FOR 5 - 85 END SWITCH
NOTE: IF THE ACTUATOR IS BRACKET S1 COMMON FOR 5 END SWITCH INDICATION A SECOND TERMINAL STRIP
WIRING TO MODULE S2 ACTUATOR S3 S2 NC, S3 NO.
EQUIPPED WITH END SWITCHES ACTUATOR S2 NC, S3 NO. WHIP IS REQUIRED
TERMINAL STRIP S3
OR POSITION INDICATION A S4 COMMON FOR 25-85 END SWITCH ZG-102 MOUNTING BRACKET MULTIPLE ACTUATOR MOUNTING
MULTIPLE ACTUATOR MOUNTING S4
SECOND WHIP IS REQUIRED S5 NC, S6 NO.
S5
S6 STANDARD MOUNTING INSTRUCTIONS - BELIMO LF & NF SERIES ACTUATORS
STANDARD MOUNTING INSTRUCTIONS - BELIMO AF SERIES ACTUATORS 1. MANUALLY MOVE THE DAMPER TO THE FAIL-SAFE POSITION. IF THE SHAFT ROTATED CCW, THIS IS A CCW INSTALLATION ("CCW" FACES OUT). IF THE SHAFT ROTATED
1. MANUALLY MOVE THE DAMPER TO THE FAIL-SAFE POSITION. IF THE SHAFT ROTATED CCW, THIS IS A CCW INSTALLATION ("CCW" FACES OUT). IF THE SHAFT ROTATED CW, THIS IS A CW INSTALLATION ("CW" FACES OUT).
CW, THIS IS A CW INSTALLATION ("CW" FACES OUT). 2. TO TEST FOR ADEQUATE SHAFT LENGTH, SLIDE THE ACTUATOR OVER THE SHAFT WITH THE SIDE WITH THE CLAMP. IF THE SHAFT DOES NOT EXTEND AT LEAST 1/8" THROUGH THE
2. TO TEST FOR ADEQUATE SHAFT LENGTH, SLIDE THE ACTUATOR OVER THE SHAFT WITH THE SIDE WITH THE CLAMP FACING OUT. IF THE SHAFT DOES NOT EXTEND AT LEAST 1/8" THROUGH CLAMP, SEE THE SHORT SHAFT MOUNTING INSTRUCTIONS.
THE CLAMP, SEE THE SHORT SHAFT MOUNTING INSTRUCTIONS. 3. IF THE CLAMP IS NOT ON THE CORRECT SIDE AS DETERMINED IN STEP 1, RE-MOUNT THE CLAMP AS FOLLOWS. IF IT IS ON THE CORRECT SIDE, PROCEED TO STEP 5. LOOK AT THE
3. IF THE CLAMP IS NOT ON THE CORRECT SIDE AS DETERMINED IN STEP 1, RE-MOUNT THE CLAMP AS FOLLOWS. IF IT IS ON THE CORRECT SIDE, PROCEED TO STEP 5. LOOK AT THE UNIVERSAL CLAMP. IF YOU ARE MOUNTING THE ACTUATOR WITH THE "CCW" SIDE OUT, POSITION THE CLAMP SO THAT THE POINTER SECTION OF THE TAB IS POINTING TO 0 AND THE
UNIVERSAL CLAMP. IF YOU ARE MOUNTING THE ACTUATOR WITH THE "CCW" SIDE OUT, POSITION THE CLAMP SO THAT THE POINTER SECTION OF THE TAB IS POINTING TO 0 AND THE SPLINE PATTERN OF THE CLAMP MATES WITH THE SPLINE OF THE ACTUATOR. SLIP THE CLAMP OVER THE SPLINE.
SPLINE PATTERN OF THE CLAMP MATES WITH THE SPLINE OF THE ACTUATOR. SLIP THE CLAMP OVER THE SPLINE. 4. LOCK THE CLAMP TO THE ACTUATOR USING THE RETAINING CLIP.
4. LOCK THE CLAMP TO THE ACTUATOR USING THE RETAINING CLIP. 5. VERIFY THE DAMPER IS STILL IN ITS FULL FAIL-SAFE POSITION.
5. VERIFY THE DAMPER IS STILL IN ITS FAIL-SAFE POSITION. 6. MOUNT THE SPRING RETURN ACTUATOR TO THE SHAFT. TIGHTEN THE UNIVERSAL CLAMP, FINGER TIGHT ONLY.
6. SLIDE THE ACTUATOR OVER THE SHAFT. 7. MOUNT THE ANTI-ROTATION STRAP AT THE BASE OF THE ACTUATOR. SLIP THE STOP OF THE ANTI-ROTATION STRAP IN THE SLOT OF THE BASE OF THE ACTUATOR. THE STUD SHOULD BE
7. POSITION THE ACTUATOR IN THE DESIRED LOCATION. CENTERED APPROXIMATELY 1/4" FROM THE END OF THE SLOT. DO NOT TIGHTEN THE SCREWS.
8. REMOVE THE SCREW FROM ONE END OF THE MOUNTING BRACKET AND PIVOT IT AWAY FROM THE ACTUATOR. 8. REMOVE THE SCREW FROM ONE END OF THE MOUNTING BRACKET AND PIVOT IT AWAY FROM THE ACTUATOR.
9. LOOSEN THE UNIVERSAL CLAMP AND, MAKING SURE NOT TO MOVE THE DAMPER SHAFT, ROTATE THE ACTUATOR APPROXIMATELY 5 IN THE DIRECTION WHICH WOULD OPEN THE 9. LOOSEN THE UNIVERSAL CLAMP AND, MAKING SURE NOT TO MOVE THE DAMPER SHAFT, ROTATE THE ACTUATOR APPROXIMATELY 5 IN THE DIRECTION WHICH WOULD OPEN THE
DAMPER. DAMPER.
10. TIGHTEN THE (2) NUTS ON THE CLAMP USING A 10mm WRENCH OR SOCKET USING 6-8ft-lb OF TORQUE. 10. TIGHTEN THE UNIVERSAL CLAMP TO THE SHAFT USING A 10mm WRENCH OR SOCKET USING 6-8 ft-lb OF TORQUE.
11. SLIP THE STUD OF THE ANTI-ROTATION STRAP INTO THE SLOT AT THE BASE OF THE ACTUATOR. THE STUD SHOULD BE POSITIONED 1/16" FROM THE CLOSED END OF THE SLOT. BEND 11. ROTATE THE ACTUATOR TO APPLY PRESSURE TO THE DAMPER SEALS AND RE-ENGAGE THE ANTI-ROTATION STRAP.
THE STRAP AS NEEDED TO REACH THE DUCT. ATTACH THE STRAP TO THE DUCT WITH #8 SELF TAPPING SCREWS. 12 TIGHTEN ALL FASTENERS.
SHORT SHAFT MOUNTING INSTRUCTIONS - BELIMO AF SERIES ACTUATORS SHORT SHAFT MOUNTING INSTRUCTIONS - BELIMO AF SERIES ACTUATORS
1. DETERMINE THE BEST ORIENTATION FOR THE UNIVERSAL CLAMP ON THE BACK OF THE ACTUATOR (WHERE YOU HAVE THE EASIEST ACCESS TO THE V-BOLT NUTS ON THE CLAMP). 1. DETERMINE THE BEST ORIENTATION FOR THE UNIVERSAL CLAMP ON THE BACK OF THE ACTUATOR (WHERE YOU HAVE THE EASIEST ACCESS TO THE V-BOLT NUTS ON THE CLAMP).
2. ENGAGE THE CLAMP TO THE ACTUATOR AS CLOSE AS POSSIBLE TO THE DETERMINED LOCATION. 2. ENGAGE THE CLAMP TO THE ACTUATOR AS CLOSE AS POSSIBLE TO THE DETERMINED LOCATION.
3. LOCK THE CLAMP IN PLACE USING THE REMAINING RETAINER CLIP. 3. LOCK THE CLAMP IN PLACE USING THE REMAINING RETAINER CLIP.
4. FOLLOW STEPS 5-9 OF THE STANDARD MOUNTING INSTRUCTIONS TO COMPLETE THE SHORT SHAFT INSTALLATION. 4. FOLLOW STEPS 5-12 OF THE STANDARD MOUNTING INSTRUCTIONS TO COMPLETE THE SHORT SHAFT INSTALLATION.
NOTE: ACTUATORS SHOULD BE MOUNTED INDOORS IN A DRY, CLEAN ENVIRONMENT FREE OF CORROSIVE FUMES. A PROTECTIVE ENCLOSURE MUST BE USED WHEN MOUNTED OUTDOORS. . NOTE: ACTUATORS SHOULD BE MOUNTED INDOORS IN A DRY, CLEAN ENVIRONMENT FREE OF CORROSIVE FUMES. A PROTECTIVE ENCLOSURE MUST BE USED WHEN MOUNTED OUTDOORS.
INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE CONDUIT SHOULD NOT EXCEED 18". INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE CONDUIT SHOULD NOT EXCEED 18".
GM SERIES ONLY
DAMPER MOTOR - BELIMO GM, AM, LF & NM SERIES DPS-
DM-3 IF MORE TORQUE IS NEEDED, A
1 AIR DIFFERENTIAL PRESSURE SWITCH
ACTUATORS SECOND ACTUATOR MAY BE MOUNTED
UNIVERSAL CLAMP 1/4" OD POLYETHYLENE TUBING
TO THE SHAFT USING THE ZG-102
RETAINING CLIP (TO STATIC PRESSURE PROBES)
MULTIPLE MOUNTING BRACKET
TO MODULE
JUNCTION BOX & TERMINAL STRIP
ACTUATOR
FLEXIBLE
CONDUIT. ANTI-ROTATION STRAP
PROVIDED BY
INSTALLER 2
APPROPRIATE 2 + HOT
1
WIRING TO MODULE 1 COMMON
3 (2) CONDUCTOR WIRE
TERMINAL STRIP 3 Y1 INPUT,0-10V
5 IN CONDUIT
5 U OUTPUT 2-10V
DUCT
1 TWO POS. OR FLOATING MOTOR
POWER AND 2 1 COMMON DIFFERENTIAL
SIGNAL WIRING IN 3 2 DRIVE CLOCKWISE PRESSURE SWITCH
APPROPRIATE
FLEXIBLE CONDUIT 3 DRIVE COUNTER CLOCKWISE
WIRING TO MODULE C
NOTE: IF THE ACTUATOR IS TERMINAL STRIP S1 S1 COMMON FOR 5 - 85 END SWITCH FILTER
NC
EQUIPPED WITH END S2 S2 NC, S3 NO. NO
SWITCHES OR POSITION ZG-102 MOUNTING S3
DI TO MODULE
INDICATION A SECOND BRACKET TERMINAL STRIP
WHIP IS REQUIRED
ACTUATOR MULTIPLE ACTUATOR MOUNTING
STANDARD MOUNTING INSTRUCTIONS - BELIMO GM & NM SERIES ACTUATORS MOUNTING INSTRUCTIONS - DP SWITCH
1. SLIP THE ACTUATOR'S UNIVERSAL CLAMP OVER THE DAMPER SHAFT. MAKE SURE THAT THE BOTTOM OF THE ACTUATOR (METAL SIDE) IS TOWARD THE DUCT AND THE CONTROLS ON THE 1. SELECT A LOCATION THAT IS FREE FROM VIBRATION, CORROSIVE ATMOSPHERE AND WHERE THE AMBIENT
COVER ARE ACCESSIBLE. PLACE THE ACTUATOR IN THE DESIRED MOUNTING POSITION. TEMPERATURE IS WITHIN THE LIMITS FOR THE SWITCH.
2. TURN THE DAMPER SHAFT UNTIL THE BLADES ARE FULLY CLOSED. 2. MOUNT STANDARD SWITCHES WITH THE DIAPHRAGM IN A VERTICAL PLANE AND WITH SWITCH LETTERING AND NAMEPLATE
3. HAND TIGHTEN THE (2) NUTS ON THE UNIVERSAL CLAMP. IN AN UPRIGHT POSITION. SOME SWITCHES MAY NOT RESET PROPERLY IF MOUNTED IN THE WRONG POSITION.
4. SLIDE THE STUD OF THE ANTI-ROTATION BRACKET INTO THE SLOT IN THE BOTTOM OF THE ACTUATOR. BEND THE STRAP AS NEEDED TO SUPPORT THE REAR OF THE ACTUATOR. 3. CONNECT SWITCH TO SOURCE OF PRESSURE, VACUUM OR DIFFERENTIAL PRESSURE. POLYETHYLENE TUBING WITH 1/4" O.D.
5. FASTEN THE STRAP TO THE DUCT WITH (2) SCREWS (#8 SELF TAPPING SHEET METAL SCREWS). IS RECOMMENDED. CONNECT TO THE (2) 1/8" NPT
6. LOOSEN THE (2) NUTS ON THE UNIVERSAL CLAMP. DISENGAGE THE ACTUATOR GEAR TRAIN BY PRESSING THE "MANUAL OVERRIDE BUTTON." KEEPING THE GEARS DISENGAGED, AND THE FEMALE PRESSURE PORTS AS NOTED BELOW:
DAMPER FULLY CLOSED, ROTATE THE CLAMP UNTIL IT IS ABOUT 5 FROM THE CLOSED POSITION. A. DIFFERENTIAL PRESSURES-CONNECT PIPES OR TUBES FROM SOURCE OF GREATER PRESSURE TO HIGH PRESSURE PORT
7. TIGHTEN THE (2) NUTS ON THE CLAMP WITH A 10mm WRENCH. USE 9-11 ft-lb OF TORQUE. MARKED HI-PR AND FROM SOURCE OF LOWER PRESSURE TO LOW PRESSURE PORT MARKED LO-PR.
B. PRESSURE ONLY-CONNECT TUBE FROM SOURCE OF PRESSURE TO HIGH PRESSURE PORT. THE LOW PRESSURE PORT IS
SHORT SHAFT MOUNTING INSTRUCTIONS - BELIMO GM & NM SERIES ACTUATORS LEFT OPEN TO ATMOSPHERE.
1. DISENGAGE THE GEARS WITH THE MANUAL RELEASE BUTTON ON THE CASING. C. VACUUM ONLY-CONNECT TUBE FROM SOURCE OF VACUUM TO LOW PRESSURE PORT. THE HIGH PRESSURE PORT IS LEFT
2. TURN THE ACTUATOR CLAMP BACK TO 5 DEGREES BEFORE CLOSED POSITION AND ALLOW GEARS TO RE-ENGAGE. OPEN TO ATMOSPHERE.
3. PULL OUT THE UNIVERSAL CLAMP AFTER REMOVING THE RETAINING CLIP. 4. ELECTRICAL CONNECTION TO THE SPDT SNAP SWITCH ARE PROVIDED BY MEANS OF SCREW TERMINALS.
4. FIX THE UNIVERSAL CLAMP ONTO THE DAMPER SHAFT.
5. MOVE THE DAMPER INTO THE CLOSED POSITION. MOUNTING INSTRUCTIONS - STATIC PRESSURE PROBES
6. POSITION THE ACTUATOR ONTO THE UNIVERSAL CLAMP. 1. INSTALLATION IS COMPLETED BY DRILLING A 1/4" HOLE IN THE SHEET METAL, INSERTING THE PROBE AND SECURING THE
7. REFIT THE RETAINING CLIP. ASSEMBLY BY USING THE MOUNTING FLANGE AS A TEMPLATE TO MARK AND DRILL (2) HOLES FOR THE SELF TAPPING SHEET
8. IF NECESSARY, BEND OR CUT THE ANTI-ROTATION STRAP ON EITHER SIDE TO FIT THE DAMPER FRAME. METAL SCREWS.
9. SLIDE THE STUD OF THE ANTI-ROTATION STRAP INTO THE SLOT ON THE ACTUATOR BASE AND FIX IT WITH THE SCREWS TO THE DAMPER FRAME.
NOTE: ACTUATORS SHOULD BE MOUNTED INDOORS IN A DRY, CLEAN ENVIRONMENT FREE OF CORROSIVE FUMES. A PROTECTIVE ENCLOSURE MUST BE USED WHEN MOUNTED OUTDOORS.
INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE CONDUIT SHOULD NOT EXCEED 18".
NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE
CONDUIT SHOULD NOT EXCEED 18".
8 of 46
DPS-
FS
2 PUMP DIFFERENTIAL PRESSURE SWITCH
VALVES
(BY INSTALLER)
Adjusting the Flow Switch Paddle
DI TO MODULE
TERMINAL STRIP
HI LO Pump
(2) CONDUCTOR
1.5 WIRE
1 in. 2 in. 2.5 in. 3 in. 4 in. 5 in. 6 in.
in. Original DP SWITCH
Paddle 1/4" NPT BRASS
Size HOUSING
A +
TO ALC CONTROL MODULE INPUT TERMINALS B -
- The F61 comes with a 3-piece paddle (1", 2" & 3" segments)
MOUNTING INSTRUCTIONS
installed. Each piece is removable. Adjust the paddle size of the pipe MOUNT UNIT IN ANY POSITION. LOCATE WHERE SHOCK AND VIBRATION ARE MINIMAL AND AMBIENT TEMPERATURE IS BELOW
161 F (71 C).
in which it will be installed. For 1", 2" or 3" pipe, use the paddle
SURFACE MOUNTING - INSERT (2) #6 SCREWS THROUGH HOLES ON 2" CENTERS.
segments as supplied.
SUSPENDED UNIT MOUNTING - MOUNT UNIT FROM ITS (2) PORTS. ALWAYS HOLD A WRENCH ON PRESSURE PORT WHEN
- If longer paddle is required, the extra paddle may be trimmed to MAKING PRESSURE CONNECTION.
fit 6" or smaller diameter pipe. Use Figure 5 to trim the paddle at the MAKING PRESSURE CONNECTION - CONNECT HIGH SIDE PRESSURE TO THE PORT LABELED HIGH. USE A WRENCH ON
PRESSURE PORT AND HOLD THE UNIT STEADY. THREAD A ¼ NPTM FITTING INTO THE PORT.
arc corresponding with the pipe size.
CAUTION: NEVER TIGHTEN BY TURNING THE CONTROL INTO THE FITTING.
Paddle
Screw WIRING - BACK OUT THE SCREW TERMINAL JUST ENOUGH TO PUT THE STRIPPED WIRE UNDER THE TERMINAL BLOCK CLAMP.
MOUNTING: MAXIMUM WIRE SIZE IS 16AWG.
Remove paddles - Mount the F61 in a section of pipe where there is a straight run SET POINT ADJUSTMENT - USE A SCREWDRIVER TO TURN THE EXTERNAL ADJUSTING SCREW. TURN “IN” (CLOCKWISE) TO
Direction of INCREASE DIFFERENTIAL PRESSURE SETTING (1 TURN = 1.5 PSID). FOR BEST SETTING ACCURACY, SET THE SWITCH USING THE
Flow that are too large of atleast 5 pipe diameters on each side of the flow switch. ACTUAL WORKING PRESSURE ENCOUNTERED IN THE APPLICATION.
for pipe diameter
- The switch should be mounted so the terminals or wire leads are NOTE: ISOLATION VALVES MUST BE INSTALLED AT THE PIPE TAP. VALVES TO BE FURNISHED BY OTHERS.
- Mount the flow switch in a standard 1" x 1" x 1" tee for 1" pipe TOP OF PIPE
1/2" NPT THREADOLET, FURNISHED AND
F61MB Pictured installation. Use a reducing tee for larger sizes of pipe to keep the flow INSTALLED BY MECH CONTRACTOR.
switch close to the pipe and provide adequate paddle length in the flow
Tee or Welded stream.
Half Coupling
- Screw the flow switch in position so the flat of the paddle is at a
1/2" NPT, (3) TYP.
Flow right angle to the flow. The arrow on the side of the case must point in
A A the direction of the flow.
Dimension “A” must be at least five pipe diameters - The F61 flow switch may be mounted on a horizontal pipe line or NEMA 3R WEATHERPROOF
From the nearest elbow, valve, or pipe restriction ENCLOSURE
a vertical pipe line with upward liquid flow. It is not recommended for THERMOWELL
Flow
IMMERSION PROBE
installations with downward flow. WIRE NUT
J-LOOP
Figure 7: Typical Installation
WIRING:
AI TO MODULE
- Make all wiring connections using proper copper conductors TERMINAL STRIP
1/2" NPT THREADOLET, FURNISHED AND
Flow only. INSTALLED BY MECH CONTRACTOR.
Flow Switch Arrestor
- Install all wiring in accordance with NEC and local regulations. MOUNTING INSTRUCTIONS - IMMERSION UNIT
1. THE THERMOWELL THREADS INTO A 1/2" FNPT THREADOLET FURNISHED AND INSTALLED BY THE MECHANICAL
Valve - On F61KB and F61LB models, use the terminal screws CONTRACTOR.
2. THE IMMERSION UNIT THREADS INTO A 1/2" FNPT THERMOWELL, NO EXTERNAL HARDWARE IS NEEDED. THERMALLY
furnished (8-32 x ¼” binder head) Substitution of other screws will void CONDUCTIVE GREASE MUST BE APPLIED TO THE PROBE PRIOR TO INSERTION TO OPTIMIZE HEAT TRANSFER.
NOTE: THE THERMOWELLS ARE DESIGNED TO CONNECT THE 1 1/8" HEX NUT TO THE IMMERSION FITTING ON THE UNIT, DO
Figure 8: Arrestor Location Schematic warranty. NOT OVER TIGHTEN OR DAMAGE TO THE FITTING MAY OCCUR.
3. TERMINATE THE UNIT AS SHOWN ABOVE.
- On F61MB models, use external wire leads. 4. INCORPORATE A "J-LOOP" INTO THE TERMINATION. A "J-LOOP" IS FORMED BY POINTING THE WIRE NUTS OF A TERMINATION
UP CREATING A "J" IN THE CABLE IN ORDER TO REDUCE THE PROBABILITY OF CONDENSATION COLLECTING IN THE WIRE
NUT.
5. USE LIQUID TIGHT FITTINGS WITH THE NEMA 3R WEATHERPROOF ENCLOSURE.
NOTE: INSTALL FLEXIBLE CONDUIT FOR ALL CABLE OR WIRE BROUGHT TO END DEVICE FROM JUNCTION BOX. FLEXIBLE
CONDUIT SHOULD NOT EXCEED 18".
9 of 46
SMK SS H548 FRACTIONAL HP MOTOR STATUS SENSOR /
SMOKE DETECTOR BRUSHED ALUMINUM OR STAINLESS STEEL
COMMAND RELAY
WALL PLATE TEMPERATURE SENSOR
1. OPEN B (NULL)
LOW HIGH
2. OPEN D (BLEED OR
PURGE)
4. CLOSE D (BLEED OR
PURGE)
6. CLOSE D (BLEED OR
PURGE)
D C A
10 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
BT485 END OF LINE SEGMENT CONDITIONER AUTOMATED LOGIC BT485 6 ea
DIAG485 ARC156 DIAGNOSTIC DEVICE AUTOMATED LOGIC DIAG485 1 ea
LGR25 LGR25 AUTOMATED LOGIC LGR25 1 ea
M8102 M8102 DDC CONTROLLER AUTOMATED LOGIC M8102 1 ea
MX4106 MX4106 AUTOMATED LOGIC MX4106 1 ea
PROT485 ARC156 PROTECTION DEVICE AUTOMATED LOGIC PROT485 2 ea
REP485 REPEATER AUTOMATED LOGIC REP485 2 ea
RSPL ROOM SENSOR WITH ADJUSTMENT AND OVERRIDE AUTOMATED LOGIC RSPL 37 ea
SE6104a SE6104A AUTOMATED LOGIC SE6104A 9 ea
SSP STAINLESS STEEL WALL PLATE SENSOR BAPI ALC/10K-2-SP 13 ea
ZN141v+ ZN141V+ AUTOMATED LOGIC ZN141V+ 1 ea
ZN220 ZN220 AUTOMATED LOGIC ZN220 18 ea
ZN253 ZN253 AUTOMATED LOGIC ZN253 1 ea
ZN551 ZN551 AUTOMATED LOGIC ZN551 32 ea
RTU-2 RTU-1
Central Office Media Center
CM-63 E
SE6104A O
RTU-1 L
Existing
Wiring
Panel “B” Panel “E” Panel “F” Panel “G” Panel “H” Panel “I” Panel “J”
TR-1 100va TR-1 100va TR-1 100va TR-1 100va TR-1 100va TR-2 75va TR-2 75va 9 ARCnet 156K
CM-50 CM-51 CM-52 CM-53 CM-54 CM-55 CM-56 CM-57 CM-58 CM-59 CM-60 CM-61 CM-62 E E
SE6104A SE6104A SE6104A SE6104A ZN253 ZN141v+ SE6104a ZN551 ZN551 ZN551 ZN551 SE6104a SE6104a O REP485 O PROT485
AHU-4 L L
AHU-1 AHU-2 AHU-3 AHU-5 VAV-1 RTU-2 VUV-1 VUV-2 VUV-3 VUV-4 VUV-5 SF-1
&
Gym / East Mech West Mech RADIANT Pre-School Pre-School Pre-School Pre-School Pre-School Pre-School Art Room Kindergarten
Multi Purpose Room Near Room Near CEILING Central Area West Area
PANEL LOOP
Room Classroom Classroom CONTROL
201 304
East Mech
Room Near
9 ARCnet 156K Classroom
105
Panel “C”
Panel “D”
TR-2 75va TR-1 100va TR-1 100va
CM-49 CM-48 CM-47 CM-46 CM-45 CM-44 CM-43 CM-42 CM-41 CM-40 CM-39 CM-38 CM-37 CM-36 CM-35 CM-34 CM-33 CM-32 CM-31 E E
CM-30 CM-29 CM-28 CM-27 CM-26 CM-25
ZN220 ZN220 ZN220 ZN220 ZN551 ZN551 ZN551 ZN551 ZN551 SE6104A ZN220 ZN220 ZN220 ZN220 ZN220 ZN220 ZN220 ZN220 ZN220 O REP485 O ZN220 ZN220 ZN220 ZN220 ZN551 ZN551
L L
1 EF 1 EF 1 EF 1 EF 3 EF’s 4 EF’s MZ ZONE 3 MZ ZONE 2 MZ ZONE 1 MZ-1 CUH-13 CUH-12 CUH-11 CUH-10 CUH-09 CUH-08 CUH-07 CUH-06 CUH-05 CUH-04 CUH-03 CUH-02 CUH-01 HP-13 HP-12
TBD Toilets South Art Room Pre-School Pre-School Northwest Area TBD TBD TBD Music TBD TBD TBD TBD TBD TBD TBD TBD TBD Repeater TBD TBD TBD TBD Classroom Classroom
Of Teachers Storage West Toilet EF Circuit 26 Teachers Lounge 205 206
Toilets Serving Existing
Lounge EF Circuit 28 Classrooms
EF Circuit 29 301/302 Wiring
303/304
305/306
ARCnet 156K 9
SSP
Panel “A”
Typical Of 13
TR-3 100va
TR-1 100va TR-4 100va TR-2 100va
CM-2 CM-3 CM-4 CM-5 CM-6 CM-7 CM-8 CM-9 CM-10 CM-11 CM-12 CM-13 CM-14 CM-15 CM-16 CM-17 CM-18 CM-19 CM-20 CM-21 CM-22 CM-23 CM-24
E CM-1 M8102
O
LGR 25 DIAG PROT ZN220 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551 ZN551
L Prim Pmps/
Evap Clr/ Vlvs OAT HP-21 HP-19 HP-20 HP-04 HP-03 HP-01 HP-14 HP-15 HP-16 HP-17 HP-23 HP-24 HP-06 HP-22 HP-18 HP-09 HP-10 HP-11 HP-07 HP-02 HP-05
Expander Library Classroom Classroom Classroom Classroom Classroom Classroom Classroom Classroom Classroom Classroom Classroom Classroom Office Classroom Classroom Classroom Classroom Teachers Classroom Classroom
MX4106 104 105 302 303 304 204 203 202 201 102 101 301 103 106 107 108 Lounge 305 306
Sec Pmps/
E 15 Vlvs/Blr
School Districts
Ethernet LAN 6 Rnet
15 15
District COOLER
E E
WebCTRL Located
At Receiving Office
OCCUPIED
MANUAL
ON
Typical Of 37
Elementary School
Michigan 48xxx
Metro Environmental, Inc.
Network Riser
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
Note: Actual communications network layout to modules will be shown on the “As Built” drawings. 6 See page 5 for cable identification 11 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
DIAG485 ARC156 DIAGNOSTIC DEVICE AUTOMATED LOGIC DIAG485 0 ea
LGR25 LGR25 AUTOMATED LOGIC LGR25 0 ea
LGR25 Without Keypad Display:
24Vac, 24VA, 1A, 50-60 Hz
OAT/H OUTSIDE AIR TEMPERATURE AND HUMIDITY SENSOR BAPI ALC/10K-2-H300-O-WP 1 ea
26Vdc, 10W, 0.4A
PANEL A 36X30 ENCLOSURE+PERF+KEYLOCKKIT HOFFMAN A-36N30ALP+A36N30MPP+AL12 1 ea
Use Copper Conductors Only
TR-1
Provided by
Class 2
H N G PROT485 ARC156 PROTECTION DEVICE AUTOMATED LOGIC PROT485 0 ea
School District PS POWER SUPPLY 24VAC IN 24VDC OUT KELE DCP-1.5W 1 ea
3V Lithium Battery Ground T2
24V ac/dc T1 TR-1,2,3,4 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 4 ea
10/100 BaseT CR-123A
Ethernet LAN connection Ethernet Port E1
Power ZN220 ZN220 AUTOMATED LOGIC ZN220 0 ea
On Off
100 LAN LINK External Gnd ZN220
Battery +3V TR-2
Lstat Rnet
H N G
Bias Rx Format
®
BACnet
Over ARCNET156 KBaud Ext. Batt. Tx Jumper: Gain1
Ground
T4
Net +
24 Vac
LGR25 T3
CMnet
BT485 Int. Batt. Net - Batt
Pwr
Net +
Control Module BT485
Shield - +
Run
Tens
456
90 1
2 wire 4 wire EIA-232
456
IN-1
901
Shield 2032 Thermistor/dry contact
CM-01
23 23
Signal Ground 0-5Vdc
78 78 IN-2
Sense
Ones
Thermistor/dry contact
Rnet n/c Rx- DCD
456
901
456
90 1
+12V 0-5Vdc
Local Access 23 23 On
n/c Rx+ DTR Rnet-
Port S1 Rnet+
4
4
3
3
Net- Tx- Rx OAT/H Gnd
2
2
1
1
O
N
Gnd Net+ Tx+ Tx Gnd Communications Selection
Rnet +
Rnet
Rnet + MSTP
Rnet EIA-232 Black - ARC156
Rnet - Rnet -
+12V Error Codes: EIA-485 Red + +12V 9600 19.2k 38.4k 76.8k
Port S2 IN-1
EIA- Tx
Chase = OK
0 = Download required
Yellow IN-1 Outside Air Temp Gnd
Inputs: 5V Max MSTP Baud
485 232
Net+ Tx
Cmnet transmit 1 = Control Program Error 485-2w Yellow IN-2
Net- Rx
Cmnet receive 2 = RAM full
3 = Comm setup error
Enhanced Access
Port on S2 IP Addr Address
MSTP
on S1
PTP
on S2
485-4w
White IN-2 Outside Air Humd 0/5vdc Gnd
4 = System error
n/c DTR Rx Archive Valid
On Assigned +100 Enable Enable
8 = Formatting
n/c
Signal Ground
DCD Port S1 transmit
Port S1 receive Off Default 0 Disable Disable
Option
CM-03 Class 2
24 Vac, 50-60 Hz
ARCnet 156 Battery low
Module Comm CAUTION:
ZN220
20VA, 0.83A
24Vdc, 0.2A, 5W
EIA-232 To Reduce the Risk of Fire Use Copper
Status Blinking Dot = “Run” or Electric Shock, Do Not CONTROLLER Conductors Only
Module Interconnect the Outputs of
EIA-485 Different Class 2 Circuits.
Address
BT485 Power DO-2
LED Format 10's 1's
CAUTION: DO-1
901 901
1 2 3 4 5 6 7 8
This product was designed
O
Power for D.O.'s BUSS
78
78
23
23
North Wall to be mounted inside the
N
456 456
building envelope. Warranty ®
voided if mounted outside. BACnet
ARCnet
Shield
Net-
Net+
PROT485 Fused
Wiring coming
from outside
of building
Unfused
Shared Connection Use for inside
wiring
Fused or unfused
Net+ Shield
Net- Net-
Shield
failure, an alternate outside air conditions sensor shall be
Panel “A”
made available to the system without interruption in
sensor readings.
30" If an OA Temp Sensor cannot be read, a default value of
Refer to Network Riser DIAG485
65°F will be used.
Drawing Sheet # 11 LGR, Boiler Room Control Panel If an OA Humidity Sensor cannot be read, a default value
of 50 % will be used.
ZN220
LGR-25 Outside Air Temperature History:
CM-03 T3 DIAG485
CM-01 The controller shall monitor and record the high and low
OAT T4
TR-1 temperature readings for the outside air. These readings
From TR-2 24VAC
DRAWN BY : TL
DIAG CHECKED BY : TS
12 of 46
Existing HWR
From Fine Arts Htg System CM-2-0 IN2 – HPWR Temp
10
Existing HWR T T2
HPWR
From Building Htg Systems
Existing relay
& wiring
L
M 1
CM-2-0 DO1 – CP-1 S/S PDT
CM-2-1 AO1 – Fine Arts Sys Vlv CM-2-1 IN3 PFA Status 23 Blue #18
H
Red #14
18 Existing
Blk #14 CM-2-1 IN1 – Fine Arts HWS Temp C C
CM-2-0 DO5 Isolation Vlv V-2
24 VAC T8 T8
Wht 22
Existing valve Blu Existing relay 6
& wiring
T T5 Existing relay & wiring Blue #18
1 2 4 5 & wiring H
PFA N
A AB
B
To Fine Arts Htg System CM-2-0 AO1 – CP-1 VSD Speed
H N
1 HPWS
CM-2-1 DO1 P-1 S/S C
VSD Black Tape
43 T8 V-2
CM-2-0 IN6 CP-1 Stat Existing valve T T3
Blue #14 9
Existing relay 1 & wiring
& wiring CM-2-0 IN3 – HPWS Temp to System
Red Tape M
Red #14 M
Blk #14 41 CM-2-1 IN4 P-1 Status CP-1
Existing
Red #14 24 VAC 19 M
Red #14 Existing valve
39
CM-2-2 AO2– Bldg Sys Vlv & wiring
V-3
H N
Existing valve CM-2-0 IN4 – Boiler HWS Temp T1 T 8
Wht
29 P-1
& wiring
T4 T
1 2 4 5
CP-2 Close Looped Evaporative
To Bldg Htg Systems N Cooling Tower
A AB
H
B T6 T M
P-2
Blue #14 CM-2-0 IN7 CP-2 Stat CM-2-0 DO6 Isolation Vlv V-3 5
T8 C
38 CM-2-1 IN5 P-2 Stat
2 Blue #18
40 Blue #14 Red Tape VSD
M Existing relay
CM-2-0 AO2 – CP-2 VSD Speed & wiring
CM-2-1 IN2 – Bldg HWS Temp
Existing relay 2
39 & wiring T8 C
Black Tape
CM-2-0 DO4 Div Vlv V-1 Existing relay
T8 C T8 C & wiring CM-2-0 DO7 Evap Cooler Enable
CM-2-1 DO2 P-2 S/S 8 CM-2-0 DO2 – CP-2 S/S
H T8 C 2 Blue #18
Blue #18
42 Blue #14
Existing relay
& wiring N CM-2-0 IN1 – HPWS Temp to Pumps
NH
Boiler U L
Existing valve
& wiring C
V-1
20 T8
CM-2-0 DO3 P-8 S/S CHECKED BY : TS
C
Blue #18 28 10 Note: Typical Existing Wire Tag Number
Blue #14 13 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
E-CS EXISTING CURRENT SWITCH SOLID CORE VERIS E112-708 6 ea
E-R EXISTING 24VAC CONTROL RELAY CORE CVR-11C 11 ea
M8102 M8102 DDC CONTROLLER AUTOMATED LOGIC M8102 0 ea
MX4106 MX4106 AUTOMATED LOGIC MX4106 0 ea
PDT DIFF PRESS TRANSMITTER 0-50 PS1, 0-5 VDC OUT, 24 VDC IN VERIS PWLX03S 1 ea
PS POWER SUPPLY 24VAC IN 24VDC OUT KELE DCP-1.5W 0 ea
T1 to T6 IMMERSION TEMP SENSOR BAPI ALC/10K-2-I-4'' 6 ea
TR-1,2,3,4 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 0 ea
I/O
M8102 Expansion
Rx Tx Run Error Power TR-3 H N G TR-4
TM H N G
Net +
CMnet BACnet
Net - Over ARCNET156 KBaud
On Off
Gnd T6 T8
Shield
Class 2 24 Vac T5 T7
24Vac, 50-60 Hz
20VA, 0.83A
Use Copper
Conductors Only
Auxiliary
Device
Port Access Port
CMnet Mode
9600/
38.4k
Inputs
ARC156
M8102
CONTROL MODULE
5V Max, 20mA Max
White #18 White #18
T1 HPWS Temp to Pumps 1 A Gnd 4 CP-2 VFD Signal 0/10vdc 2 Black Tape 2
8 2 B
IN1 AO2
+ 3
Blue #18 Blue #18
5A Typical Connections
HPWR Temp White #18 White #18 VFD TB1
10 A 2M Gnd 2 CP-1 VFD Signal 0/10vdc Black Tape 2
T2 3
4 B
IN2 CM-02 Caution:
AO1
+ 1
Blue #18 1 Blue #18 5A
5
HPWS Temp to System Boiler Enable Blue #18
T3 9
5 A
IN3
To Reduce the Risk of Fire
or Electrical Shock, Do Not
interconnect the Outputs of
DO8
16
20 E-R T8
6 B Universal Input 15
Different Class 2 Circuits.
Boiler HWS Temp 7 A
Mode Select Evaporative Cooler Enable White/Purple White/Red
PDT T4 29 IN4 DO7
14
E-R T8
0-5 VDC 8 B 13
Diff Pressure Isolation Valve V-3 Blue #18
0-50 PSI
- + S
9 A
IN5 0-5Vdc NC NO DO6
12
5 E-R T8
10 B Thermistor/ 0-20 mA 11
CP-1 Status dry-contact Isolation Valve V-2 Blue #18
White Existing CS 1 Red Tape 11 A
IN6 DO5
10 6 E-R T8
12 B 9
CP-2 Status Diverting Valve V-1 Blue #18
Existing CS 2 Red Tape 13 A
IN7 A - Input Signal 24V Max. DO4
8
8 E-R T8
14 B 3A Max. 7
Blue #14 CP-8 Status
B - Gnd/Loop Power CP-8 S/S Blue #14
Existing CS Blue #14 14 15 A
IN8 DO3
6 28 E-R T8
16 B 5
CP-2 S/S Blue #18
17 A
IN9 DO2
4 2 E-R T8
18 B 3
Red 38.4k
CP-1 S/S Blue #18
Black
+
24 VDC
19 A
IN10 Cmnet Baud
Module
Address DO1
2 1 E-R T8
- 20 B T7
G
PS 9600 Format 10's 1's
1
24 VAC 1 2 3 4
901 901
H I/O O
78
78
N
23
23
Expansion 456 456
T5
I/O
MX4106 Expansion
T6 Expander Run Power
I/O
On Off
Gnd T6
24 Vac T5
MX4106
Access Port
POINT EXPANDER
5 A Gnd 8
Fine Arts Pump Status
Existing DPS 23 6 B
IN3
Universal Input
AO4
+ 7
Red #14 Mode Select
Existing DPS
39 P-1 Status
7 A
IN4 AO3
Gnd 6
Red #14 B +
Blue #14 41 8
Caution:
5
White #18
Existing DPS Blue #14
38 P-2 Status
9 A
IN5 0-5Vdc
To Reduce the Risk of Fire
or Electrical Shock, Do Not AO2
Gnd 4
Blue #18
3 Way Valve to Bldg Systems 0/10vdc
19
40 10 B Thermistor/
dry-contact
0-20 mA interconnect the Outputs of Different
Class 2 Circuits.
Gnd
+ 3
2 White #18
11 A 3 Way Valve to Fine Arts 0/10vdc
12 B
IN6 AO1
+ 1 Blue #18 18
13 A 24V Max. 8
Red #18 Unknown Use
14 B
IN7 A - Input Signal 3A Max.
DO4
7
Black #18 ?
B - Gnd/Loop Signal
Fine Arts Pump S/S Blue #14
15 A
IN8 DO3
6 33 E-R T8
16 B 5
NO
P-2 S/S Blue #14 Blu #14
17 A
IN9 DO2
4 42 E-R 44 T8
18 B 3
NC P-1 S/S Black #14 Blk #14 T8
19 A Expander 2
43 E-R 45
20 B
IN10
Address
1's
DO1
1 T7 Elementary School
I/O 901
Michigan 48xxx
78
23
Expansion 456
DRAWN BY : TL
CHECKED BY : TS
15 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CDT COLD DECK AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 1 ea
CR1,2 COOLING RELAY 24VAC DPDT WITH INDICATING LIGHT IDEC RH2B-ULAC24V + SH2B-05 SOCKET 2 ea
E-CS EXISTING CURRENT SWITCH VERIS E112-700 2 ea
E-DA1 EXISTING DAMPER ACTUATOR 120VAC 2/15VDC CONTROL INVENSYS MP-5430 1 ea
IN-1 Return Air Temperature E-DA2 EXISTING DAMPER ACTUATOR 120VAC 2/15VDC CONTROL INVENSYS MM-500-0-0-1 1 ea
E-DPS EXISTING CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH INVENSYS PC-301 1 ea
E-FRZ EXISTING FREEZESTAT DPST INVENSYS TC-5232 1 ea
T RAT
E-V1 MZ EXISTING 3-WAY 1-1/4'' CV20 GPM 27 0/15VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 1 ea
RF ER1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
EA N.C. RA HDT HOT DECK AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 1 ea
MAT MIXED AIR AVG. TEMP. SENSOR BAPI ALC/10K-2-A-24' 1 ea
RAT RETURN AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 1 ea
E-DA2 M SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
Red (Not Used) EXISTING
E-CS
IN-6 – Return Fan Status
Yellow + HWR HWS
AO-1 Mixing Dampers 5/10vdc _
Blue Interlock Wires To Supply Fan Starter
DO-2 – Return Fan Start/Stop Red (Not Used)
Black Starter
120vac AO-2 – Hot Deck Valve Control 5/10vdc Yellow +
White
Blue _
IN7 - Freezestat
Black
E-DA1 120vac White Trips @ 38F IN-3 Hot Deck Temperature
Red (Not Used) EXISTING Auto Reset
E-V1 MZ
AO-1 Mixing Dampers 5/10vdc Yellow + LLS-1 DTS-1
Blue
_ N.O.
IN-8 – Clogged Filter Switch Interlock Wires To Supply Fan Starter Pg-7 Pg-7
Black E-FRZ T HDT
120vac White
IN-2 – Mixed Air Temp Hot N.O.
Deck
HW
DAS-1
Pg-7
E-DPS T MAT1 E-SMK
SF
HI LO
OA N.C. Typical of Zone 3 Total DA
® Class 2 On Off
+ Gnd
+
Gnd
Aux Power Out BACnet
Over ARCNET156 KBaud
24Vac, 50-60 Hz
20VA, 0.83A 24V ac TR1 H N G
Gnd +5V Use Copper
Conductors Only
Select Power
1 IN-1 T2
Return Air Temperature +24V
Batt
-
T1
2 IN-2 IN-1, IN-2: Pulse Count Ability
Mixed Air Temperature CR2032
+
3 Gnd 1 + IN-1 Tx
4 IN-3 2 + IN-2 BACnet
Hot Deck Air Temperature 3 Gnd CM-40
5 IN-4 Shield
Cold Deck Air Temperature 4 + IN-3 Rx To Or From Next
6 Gnd
5 + IN-4
Net-
ARCnet Network Module
7 IN-5 Net+
6 Gnd
Supply Fan Status
IN-6 7 + IN-5 BT485
SE6104a
8
Return Fan Status Spare
9 Gnd 8 + IN-6 12
9 Gnd DO-6
10 IN-7 12 11
Freezestat - Open Contact Is Alarm 10 + IN-7 CONTROL MODULE DO-6 Spare
11 IN-8 11 10
Clogged Filter Alarm 11 + IN-8 DO-5
10 9
12 Gnd 12 Gnd Universal Input
DO-5 Cooling 2nd Stage CR2 Cooling Stage 2
Mode Select 9 8
1 IN-9 1 + IN-9 mA
Outputs
24V Max, 3A Max
DO-4 Condenser Interlock
2 + IN-10 Thermistor/ 8 7
Cooling 1st Stage T2 Wiring
2 IN-10
3 Gnd dry contact/ DO-4
6
Cooling Stage 1
7
3 Gnd RTD
Caution: DO-3 Condenser Control Circuit (field verify)
Inputs: All Volts To Reduce the Risk of Fire 6 5 T2
10V Max, 20mA Max
Odd Even
or Electrical Shock, Do Not DO-3 Return Fan Start / Stop CR1
interconnect the Outputs of 5 4
Different Class 2 Circuits. DO-2
4 3
Supply Fan Start / Stop
Auto Off On DO-2
3
2
DO-1
2
1 T1
Elementary School
DO-1
1 Michigan 48xxx
1 Gnd
Logistat
Stat
MSTP Baud
8
Metro Environmental, Inc.
2 Temp 76.8k
Select AO-4
7
Sw Gnd Rnet
3
4 LS5v
Temp
38.4k
BACnet Mode AO-4 +
Gnd 8
7 6 Multi-Zone MZ-1 Control
AO-3
Sw LogiStat 19.2k MSTP 5
Gnd Run Gnd 6
5
LS5v Port AO-3 + 5
6 Rn+ Gnd
9600 ARC156
AO-2
4
5/10vdc Hot Deck HW Valve REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
Gnd 4
7 Rn- Rnet+ AO-2 + 3
3
Local Access Error
2
8 +12V Rnet- Gnd 2 AO-1 5/10vdc Mixing Dampers DRAWN BY : TL
Sense
AO-1 + 1
Rnet+
Rnet-
+12V
Gnd
78
N
23
23
16 of 46
The heating will be enabled whenever: High Return Air Humidity: If the return air humidity is greater than 70% (adj.).
Run Conditions - Scheduled:
The unit will run based upon an operator adjustable schedule. Outside air temperature is less than 65°F (adj.). Low Return Air Humidity: If the return air humidity is less than 5% (adj.).
The cooling will be enabled whenever: The economizer will close whenever:
Outside air temperature is greater than 60°F (adj.). Mixed air temperature drops from 55°F to 46°F (adj.)
AND the economizer (if present) is disabled or fully open. OR on loss of supply fan status.
AND the supply fan status is on. OR the freezestat (if present) is on.
The cooling coil valve will open to 50% (adj.) whenever the freezestat (if present) is The outside and gravity relief air dampers will close and the return air damper will open
on. when the unit is off. If Optimal Start Up is available the mixed air damper will operate as
described in the occupied mode except that the outside air damper will modulate to fully
Alarms will be provided as follows: closed.
High Cooling Supply Air Temp: If the cooling supply air temperature is 5°F Mixed Air Temperature:
(adj.) greater than setpoint. The controller will monitor the mixed air temperature and use as required for economizer Elementary School
control (if active).
Michigan 48xxx
Hot Deck - Heating Supply Air Temperature Setpoint - Outside Air Reset:
The heating supply air temperature setpoint will reset based on outside air temperature. Alarms will be provided as follows: Metro Environmental, Inc.
As outside air temperature drops from 55°F (adj.) to 30°F (adj.) the heating supply air Multi-Zone MZ-1 Sequence Of Operation
temperature setpoint will reset upwards from 70°F (adj.) to 110°F (adj.). High Mixed Air Temp: If the mixed air temperature is greater than 90°F (adj.).
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
Hot Deck - Heating Coil Valve: Low Mixed Air Temp: If the mixed air temperature is less than 45°F (adj.). DRAWN BY : TL
The controller will measure the heating supply air temperature and modulate the CHECKED BY : TS
heating coil valve to maintain its setpoint. Return Air Humidity:
The controller will monitor the return air humidity and use as required for economizer
control (if active).
17 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
PANEL C 24'' X 24'' ENCLOSURE+PERF PANEL HOFFMAN A24N24ALP + A24N24MPP 1 ea
RSPL ZONE SENSOR WITH ADJUSTMENT AND OVERRIDE BUTTON AUTOMATED LOGIC RSPL 0 ea
TR-1,2 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 2 ea
Red (Not Used) ZDA EXISTING DAMPER ACTUATOR 120VAC 2/15VDC INVENSYS MP-5430-0-0-3 3 ea
ZDAT ZONE DISCHARGE AIR TEMPERATURE BAPI ALC/10K-T2-D-8'' 3 ea
Black Yellow +
_ AO-1 – Zone Damper Control 5/10vdc
120vac Blue ZN551 ZN551 AUTOMATED LOGIC ZN551 0 ea
White
ZDA Existing
IN-1 – Zone Discharge Air Temp
Hot
N.O. DTS-1
Deck ZDAT Pg-7
T
Typical of DA
3 Zone
Zone Temperature Control Run Conditions - Scheduled:
Cold The unit will run according to a user definable time schedule in the following modes:
N.C. BI - Zone Override
Deck
AI - Zone Temp Occupied Mode: The unit will maintain
T
CM-41 Zone 1 Unoccupied Mode (night setback): The unit will maintain
CM-42 Zone 2
CM-42 Zone 3
To Or From Next
Net +
Gnd T2 o A 85°F (adj.) cooling setpoint.
Network Module ARCnet Net -
T1
RSPL Shield
24 Vac
Rnet+
Gnd o
COOLER Rnet AO-1
ZN551
Rnet-
+12V
OCCUPIED
MANUAL
ON
IN-1 Zone Discharge Air Temperature
Alarms will be provided as follows:
AUTOMATED LOGIC
IN-1
IN-2
Gnd
DO-3 setpoint by a user definable amount (adj.).
Gnd DO-2
IN-4
IN-5
DO-1
Low Zone Temp: If the zone temperature is less than the heating setpoint by
LED
BUS
a user definable amount (adj.).
Class 2
High Discharge Air Temp: If the discharge air temperature is greater than
Multi-Zone MZ-1 Temperature Control Panel 24Vac, 50-
120°F (adj.).
60 Hz
Gn
TM 20VA, On Off
Gn+ Aux Power Out OverBACnet
ARCNET156 24V-
d
d Sele 0.83A ac
KBaud Use
+5 ct +24 Power
V V Copper
Batt -
Conductor
1 +
Gn IN-1
CR20
s Only
32 +
CMnet
Tx CR1 CR2
2 Shie
d
3 + ld R
Gn IN-2 Net- x
4 Net
d
5 +
6
7 +
Gn IN-3
d
Gn IN-4
SE6104 +
Bias
12
8 CONTROL MODULE DO-6
d Inputs: All 11
9 +
1 Gn IN-5 10V Max, 20mA Outputs 10
0 d Max 24V Max, DO-5
11 + Caution:3A Max 9
Low Discharge Air Temp: If the discharge air temperature is less than 40°F
Gn IN-6 To Reduce the Risk ofDO-4 8
12 IN-1, IN-2: Pulse
d Fire 7
13 + Count Ability
Gn IN-7 or Electrical Shock, Do 6
14
d Not interconnect the DO-3 5
15 +
Gn IN-8 Outputs of 4
16 Different DO-2
d Universal Auto Class
Off 2
17 + 3
Gn IN-9 Input Circuits.On
18 2
d Mode Select DO-1
19 + Thermi 1
GnIN-10 ster/
(adj.).
20 0-
d dry 0-10V- MSTP
20mA contact dc Gn
76.8Baud 8
Gnd / k AO-4 d
Tem 38.4 + 7
LogiStat RTD Cmnet Gn
p k 6
Sw Port Mode AO-3 d
LS5 Ru 19.2 MST
+ 5
v LogiStat (IN-9, n k P Gn
Gnd 960 ARC 4
Rne 10 disabled)
Stat Rnet 0 156 AO-2 d
Rne
t+ Erro + 3
Local Gn
+12
t- Rn Select r 2
Access Module AO-1 d
Gnd
Rne
Rne
Sen
For
+12
V et + 1
se
t+
78
23
23
456 N
456 20m
10V
A
Fo Lstat
Bias Rx rm Rnet
Jumper:Ground
Net + Tx at
Gain1 24 Vac
CM
net
Shield - +
CR ErrThermist
78 78
On Ten
456
203 IN-1or/dry
456
901
901
23 23
2 Thermist
78 78 Sen
+12 IN-2contact
or/dry
456
0-5Vdc
es
456
se
901
contactO
901
23 23 Rne
V
Rne
t- 4 n
0-5Vdc
3
t+
1
O2
N3
4
Gnd Communic 2
M 1
Gnd
Rne ations
AR
Rnet
Rne 9 ST
t+ 19Selection
C13 7
+12
t- 6 P
.2 8.
56 6.
V Inputs: 0
IN-1 k MSTP
Gnd 5V Max 0
IN-2
Gnd
Baud
4k 8k
Class 2 ZONE 1
24 Vac,
CAUTION: 50-60 Hz
To Reduce the 20VA,
Risk of Fire 0.83A
or Electric Shock, ZN220 24Vdc,
Do Not CONTROLL 0.2A, 5W
CAUTION: the
Interconnect ER Use
This product
Outputs of was Copper
Elementary School
DO-2
designedClass 2
Different Conductor
DO-1
to be mounted
Circuits. s Only
Power for D.O.'sBUSS
inside the ®
building envelope.
BACnet
Warranty voided if
mounted outside.
Fo Lstat Fo Lstat
Bias Rx rm Rnet Bias Rx rm Rnet
Michigan 48xxx
Ground
Jumper: Jumper:
Ground
Net + Tx at Net + Tx at
Gain1 24 Vac Gain1 24 Vac
CM
CM
net
net
456
203 IN-1or/dry
456
203 IN-1or/dry
456
456
901
901
s
901
901
23 23 Thermist 23 23
2 Thermist
2
Sen contact Sen contact
78 78 +12 IN-2or/dry 78 78 +12 IN-2or/dry
456
0-5Vdc
456
es
0-5Vdc
es
456
456
se contactO
901
se
901
contactO
901
901
23 23 Rne 23 23 Rne
V
V
Rne Rne 4 n
t- 4 n
0-5Vdc t- 0-5Vdc
3
3 t+
1
O2
N3
4
t+
1
O2
N3
4
Rne 9 ST Rne 9 ST
t+ 19Selection
C13 7 t+ 19Selection
C13 7
+12
t- 6 P +12
t- 6 P
.2 8.
56 6. .2 568. 6.
V Inputs: 0 V Inputs: 0
18 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CO2 RETURN AIR DUCT MOUNTED CO2 SENSOR VERIS CDE 1 ea
E RIB-1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
E RIB-3,4 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
E-CS EXISTING CURRENT SWITCH VERIS E112-700 2 ea
E-DM1 EXISTING DAMPER MOTOR 120VAC 2/15VDC CONTROL INVENSYS MP-5430 1 ea
E-DM2 EXISTING DAMPER MOTOR 120VAC 2/15VDC CONTROL INVENSYS MM-500-0-0-1 1 ea
E-DPS EXISTING CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH INVENSYS PC-301 1 ea
RA
IN-6 – Filter Differential Pressure Sw. E-FRZ EXISTING FREEZESTAT DPST INVENSYS TC-5232 1 ea
E-V1 AHU1 EXISTING 3-WAY 1-1/4'' 6/9VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 1 ea
AO-3 Face & By-Pass Dampers
MAT MIXED AIR AVG. TEMP. SENSOR BAPI ALC/10K-2-A-24' 1 ea
CO2
IN-1 Return Air Co2 Interlock Wiring To Fan Starter PANEL B EXISTING INVENSYS COMMUNICATIONS PANEL INVENSYS N/A 1 ea
C RSPL ZONE SENSOR WITH ADJUSTMENT AND OVERRIDE BUTTON AUTOMATED LOGIC RSPL 0 ea
IN-7 Freezestat SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
TR-1 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 1 ea
+ - T1 DO-3 – Cooling 1st Stage
E-DM2
E-DM1
3 1 2
DO-4 – Cooling 2nd Stage
N.O. IN-3 – Discharge Air Temperature
AO-1 OA & RA Dampers + 3
- 1 E-DPS N.C.
T1 2 PDS
E-FRZ T DAT
HW SF
OA N.C. N.O. DX SA
MS OL'S
MAT M Existing 208/230
L1
Smoke Detector VAC L2 MTR
IN-4 – Fan Status L3
IN-2 – Mixed Air Temp E-CS
Interlock Wiring To Fan Starter IN-4 Fan Status
Black / Blue
DO-1 – Fan Start/Stop E-CS
24v Starter FUSE
Com Black
O 120VAC
E-CS
IN-5 – Pump Status H A E-FZ
OL'S
AO-2 Heating Valve 0/20mA + Yellow
_ / White
Set 38F
MS
Red E-V1 Motor MS OL'S
Smoke
AHU1 Starter L1 Detector
208/230
L2 MTR DO-1- Fan S/S
HWHR
C NC
DO-2 – Pump Status
VAC
L3
T2 Supply Fan Motor
BI - Zone Override E-Rib #1 Starter Control
NO IN-5 Pump Status
AHU-1 Multi Purpose Room Temperature Control Panel Gn+ Aux Power Out OverBACnet
TM
ARCNET156
24Vac, 50-
60 Hz
20VA,
0.83A
On Off
Gn
24V-
d
d Sele KBaud ac
+5 ct +24 Use
Power
V V Copper
Batt -
Conductor
CR20
s Only
1 + 32 + Tx
Gn IN-1 CMnet
2 Shie
d
3 + ld R
Gn IN-2 Net- x
4 Net
d
5 +
Gn IN-3
SE6104 +
Bias
Pump Motor
6
d
T2
1 Gn IN-5 10V Max, 20mA Outputs 10
0 d Max 24V Max, DO-5
11 + Caution:3A Max 9
Gn IN-6
12 IN-1, IN-2: Pulse To Reduce the Risk ofDO-4 8
d Fire 7
13 + Count Ability
Gn IN-7 or Electrical Shock, Do 6
14 DO-3
d Not interconnect the
Starter Control
15 + 5
Gn IN-8 Outputs of 4
16 Different DO-2
d Universal Auto Class
Off 2
17 + 3
Gn IN-9 Input Circuits.On
E-Rib #2
18 2
d Mode Select DO-1
19 + Thermi 1
GnIN-10 ster/
20 0-
d dry 0-10V- MSTP
20mA contact dc Gn
76.8Baud 8
Gnd / k AO-4 d
Tem 38.4 + 7
LogiStat RTD Cmnet Gn
p k 6
Sw Port Mode AO-3 d
LS5 Ru 19.2 MST
+ 5
v LogiStat (IN-9, n k P Gn
Gnd 960 ARC 4
Rne 10 disabled)
Stat Rnet 0 156 AO-2 d
Rne
t+ Erro + 3
Local Gn
+12
t- Rn Select r 2
Access Module AO-1 d
Gnd
Rne
Rne
Sen
For
+12
V et + 1
se
t+
Rnet Address mat
V
t-
10's01 1's 1 2 AO Mode0-
9 901 O
3 4 0- Select
78
78
23
23
456 456 N 20m
10V
A
24"
® Class 2 On Off
+ Gnd
+
Gnd
Aux Power Out BACnet
Over ARCNET156 KBaud
24Vac, 50-60 Hz
20VA, 0.83A 24V ac TR-1 L1 L2 G
Gnd +5V Use Copper
Conductors Only
Select Power
1 IN-1 T2
Return Air CO2 +24V - Cable 10
2 IN-2
Batt T1
Mixed Air Temperature IN-1, IN-2: Pulse Count Ability CR2032
+ With Red Tape
3 Gnd 1 + IN-1 Tx
4 IN-3 2 + IN-2 BACnet
Discharge Air Temperature 3 Gnd Shield
CM-50
5 IN-4
Supply Fan Status 4 + IN-3 Rx To Or From Next
6 Gnd
5 + IN-4
Net-
ARCnet Network Module
7 IN-5 Net+
6 Gnd
Pump Status IN-6 7 + IN-5 BT485
SE6104a
8
Clogged Filter Alarm 9 Gnd 8 + IN-6 12
9 Gnd DO-6
10 IN-7 12 11
Freezestat - Open Contact Is Alarm 10 + IN-7 CONTROL MODULE DO-6
11 IN-8 11 10
11 + IN-8 DO-5
12 Gnd 12 Gnd Universal Input
DO-5
10 9
2nd Stage Cooling Start / Stop E-Rib #4
1 + IN-9
Mode Select
Outputs 9 8 Wire To Enable 2nd Stage Cooling TR1
1 IN-9 mA DO-4
2 + IN-10 Thermistor/
24V Max, 3A Max
8 7 E-Rib #3 T2
2 IN-10 DO-4 1st Stage Cooling Start / Stop
3 Gnd dry contact/
RTD 7 6 Wire To Enable 1st Stage Cooling
3 Gnd Caution: DO-3
Inputs: All Volts To Reduce the Risk of Fire 6 5
E-Rib #2 T2
10V Max, 20mA Max
or Electrical Shock, Do Not DO-3 Heating Pump Start /Start
Odd Even
interconnect the Outputs of 5 4 Wire To Enable Heating Pump
Different Class 2 Circuits.
Auto Off On DO-2
4
DO-2
3
2
SF Fan Start / Stop E-Rib #1 T2
Wire To Enable Supply Fan Motor Starter
Elementary School
3
DO-1
DO-1
2 1 T1 T2 Michigan 48xxx
1
Gnd Rnet
Select AO-4
7
AHU-1 Control
3 Sw 38.4k Gnd 8
4 LS5v
Temp BACnet Mode AO-4 + 7 6 Face and By-Pass Dampers 2/10vdc
AO-3
WARMER
Gnd
Sw LogiStat Run
19.2k MSTP
Gnd 6 5 REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
5
LS5v Port AO-3 + 5
6 Rn+ 9600 ARC156
4 Heating Valve 0/20mA
AO-2
COOLER
Rnet 7 Rn-
Gnd
Rnet+
Error
Gnd 4
AO-2 + 3 3
DRAWN BY : TL
Local Access
8 +12V Rnet- Gnd 2 AO-1
2 Mixing Dampers 2/10vdc
Sense
AO-1 + 1
Rnet+
MANUAL
Rnet-
+12V
Gnd
78
N
23
23
Supply Fan:
Continued On Next Page
The supply fan shall run anytime the unit is commanded to run, unless shutdown on safeties. To prevent short
cycling, the supply fan shall have a user definable (adj.) minimum runtime. Existing motor starter current switch
will monitor the fan status.
Alarms shall be provided as follows:
Supply Fan Failure: Commanded on, but the status is off.
Supply Fan in Hand: Commanded off, but the status is on.
Supply Fan Runtime Exceeded: Status runtime exceeds a user definable limit (adj.).
DRAWN BY : TL
CHECKED BY : TS
20 of 46
Economizer:
The controller shall measure the zone temperature and modulate the economizer dampers in sequence to
maintain a setpoint 2°F less than the zone cooling setpoint. The outside air dampers shall maintain a minimum
adjustable position of 20% (adj.) open whenever occupied.
The economizer shall be enabled whenever:
Outside air temperature is less than 65°F (adj.).
AND the outside air temperature is less than the return air temperature.
AND the supply fan status is on.
The economizer shall close whenever:
Mixed air temperature drops from 50°F to 45°F (adj.).
OR on loss of supply fan status.
OR the freezestat (if present) is on.
The outside air dampers shall close and the return air damper shall open when the unit is off. If Optimal Start Up is
available, the mixed air damper shall operate as described in the occupied mode except that the outside
air damper shall modulate to fully closed.
CHECKED BY : TS
21 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
E-CS EXISTING CURRENT SWITCH VERIS E112-700 2 ea
E-DM1 EXISTING DAMPER MOTOR 24VAC 2-POSITION W/ AUX SW. BELIMO AF24-S-US 1 ea
E-DM2 EXISTING DAMPER MOTOR 24V 2/10VDC CONTROL BELIMO AF24-SR-US 1 ea
E-DPS EXISTING CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH INVENSYS PC-301 1 ea
E-FRZ EXISTING FREEZESTAT DPST INVENSYS TC-5232 1 ea
E-RIB1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
E-V1 AHU EXISTING 3-WAY 1-1/4'' 6/9VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 3 ea
PANEL E 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
IN-4 – Filter Differential Pressure Sw. PANEL F 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
PANEL G 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
AO-1 Face & By-Pass Dampers
SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
Interlock Wiring To Fan Starter
IN-5 Freezestat
M
Existing
Smoke Detector
E-CS
IN-2 – Fan Status
Interlock Wiring To Fan Starter
Black / Blue
DO-2 – Fan Start/Stop
24v Starter
Black MS OL'S
Com
L1
IN-3 – Pump Status 208/230
E-CS L2 MTR
AO-2 Heating Valve 0/20mA + Yellow
_ / White
VAC
Red MS OL'S L3
E-V1 AHU Motor
Starter L1 IN-2 Fan Status
208/230
C NC VAC L2 MTR
HWHR DO-3 – Pump Start/Stop L3 FUSE
E-CS
1 IN-1
Select
Conductors Only
Power
T2 12"
Discharge Air Temperature +24V
Batt
-
T1
2 IN-2 IN-1, IN-2: Pulse Count Ability
Supply Fan Status CR2032
+ CM-51 AHU-2
3 Gnd 1 + IN-1 Tx
4 IN-3 2 + IN-2 BACnet CM-52 AHU-3
Pump Status 3 Gnd CM-53 AHU-4 +
Aux Power+5V Over ®
BACnet
Class 2
24Vac, 50-
60 Hz
20VA, On Off Gnd
To Or From Next
Use
+ IN-3
Copper
4
ct Batt
Rx
-
IN-1, IN-2: Pulse
+24 Conductor
ARCnet
CR20
Count
V Ability s Only
1 + IN-1 32 + Tx
6 Gnd Net- 2 Gn
3
+ IN-2
BACn
Shie
et
IN-4
ld
5 +
d
Network Module
4 + IN-3 R
5 + IN-4 Net- x
Gn
6 BT48
d IN-5 Net+
7 IN-5 Net+ 7 +
8 + IN-6
SE6104a 5
6 Gnd
Gn
9
12"
1 d 12
+ IN-5
1 + IN-9
SE6104a
2 + IN-10 8
8 Gn dry
3Inputs: All contact
3A Max
Risk of Fire DO-4
OA Damper Status
d 7
or Electrical
10V Max, 20mA/ VoltsOd Eve 6
Shock, Do Not DO-3
Max RTD 5
IN-6
d n interconnect the
9 Gnd 8 + 12 OutputsAuto
of Off
On
Different Class
2 Circuits.
DO-2
DO-1
4
3
2
10 IN-7 12 11
Tem
p
Sw
Stat
Select
76.8Baud
k
38.4 Gn
DO-6
BACnet 8
10 + IN-7
AO-4 +
d 7
CONTROL MODULE
k Mode
LS5 Rnet
v LogiStat Ru 19.2 MST Gn
6
n k P AO-3 +
d 5
Port 960 ARC
Gn
11 IN-8 11 10 Gnd
Local Erro
0 156
AO-2 d 4
+ 3
IN-8
Sense
Rne Gn
Rnet+
11 + Access r
Rnet-
+12V
t+ Module For 2
Gnd
DO-5 Rne
Rnet
t-
Address mat
10's 1
90 901
1's O
1
3
2
4
AO-1 +
d 1
AO Mode0-
10
0- Select
78
78
23
23
N
9 20m
456 456
2
Open OA Damper Motor T2
Elementary School
2 1 T1
DO-1
1
Michigan 48xxx
1 Gnd
Logistat MSTP Baud
Metro Environmental, Inc.
Stat 76.8k
8
2 Temp AO-4
Select
3 Sw Gnd Rnet
38.4k Gnd 8
7 AHU-2, 3 & 4 Control
Temp BACnet Mode AO-4 + 7 6
4 LS5v AO-3
Sw LogiStat 19.2k MSTP 5
Gnd Run Gnd 6
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
5
LS5v Port AO-3 +
6 Rn+ 9600 ARC156
5 4 Heating Valve 0/20mA
Gnd Gnd 4 AO-2
7 Rn- Rnet+ AO-2 + 3
3
Rnet-
Local Access Error
2 Face and By-Pass Dampers 2/10vdc DRAWN BY : TL
8 +12V Gnd 2 AO-1
Sense
AO-1 +
Rnet+
Rnet-
+12V
Gnd
78
N
23
23
22 of 46
Makeup Air Unit - Supply Air Temp (typical of 3)
Heating Coil Valve:
Run Conditions - Interlocked:
Below 55F (adj.) and above 38F (adj.) outdoor air temperature the controller shall measure the supply air
The AHU-2, 3 & 4 units run via the DDC occupied mode time schedule unless shutdown on safeties.
temperature and modulate the heating coil valve to maintain its discharge air 55F (adj.) heating setpoint.
Below 38F outdoor air temperature the heating coil valve will remain full open to the coil.
Freeze Protection:
The unit shall shut down and generate an alarm upon receiving a freezestat status. The setpoint for the
Prefilter Status:
existing freezestat is 35F adjustable at the freezestat. The heating coil valve shall open to 100% (adj.)
The controller shall monitor the prefilter status.
whenever the freezestat is on.
Alarms shall be provided as follows:
Prefilter Change Required: Existing prefilter differential pressure switch exceeds a user definable
Outside Air Damper:
limit (adj.).
The outside air damper shall open anytime the unit runs and shall close anytime the unit stops. The supply
fan shall start only after the damper status has proven the damper is open. The outside air damper shall close
Supply Air Temperature:
10 sec (adj.) after the supply fan stops.
The controller shall monitor the supply air temperature.
Alarms shall be provided as follows:
Alarms shall be provided as follows:
Outside Air Damper Failure: Commanded open, but the status is closed.
High Supply Air Temp: If the supply air temperature is greater than 120°F (adj.).
Outside Air Damper in Hand: Commanded closed, but the status is open.
Low Supply Air Temp: If the supply air temperature is less than 45°F (adj.).
Supply Fan:
Unoccupied Mode:
The supply fan shall run anytime the unit is commanded to run. To prevent short cycling, the supply fan
During the unoccupied mode the fans remain off, outdoor dampers are closed and mechanical cooling is
shall have a user definable (adj.) minimum runtime, unless shutdown on safeties. The status of the fan is
disabled. Fan cycles with the modulating heating valve to maintain the unoccupied zone setpoint. Below
monitored via existing motor starter current switch.
40F outdoor air temperature the heating coil valve will modulate and the heating pump will cycle to
Alarms shall be provided as follows:
maintain a low limit plenum temperature of 50F (adj.).
Supply Fan Failure: Commanded on, but the status is off.
Supply Fan in Hand: Commanded off, but the status is on.
Note: The heating system piping is filled with an unknown glycol mixture.
Supply Fan Runtime Exceeded: Status runtime exceeds a user definable limit (adj.).
Pump in Hand: Commanded off, but the status is on. AHU-2, 3 & 4 Sequence Of Operation
Pump Runtime Exceeded: Status runtime exceeds a user definable limit REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
23 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CFS CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH CLEVELAND AFS-222 1 ea
E-CS CR EXISTING CURRENT SWITCH WITH COMMAND RELAY VERIS H948 1 ea
E-DAT EXISTING DISCHARGE AIR TEMPERATURE SENSOR ALERTON TS-2008BT 1 ea
E-DM1,2 EXISTING DAMPER MOTOR 24VAC 2/10VDC CONTROL BELIMO LF24-SR 2 ea
RA E-FRZ FREEZESTAT ALCO FS50 1 ea
E-MAT EXISTING MIXED AIR TEMPERATURE SENSOR ALERTON TS-2008BT 1 ea
E-TR 120/24VAC 75VA TRANSFORMER HONEYWELL AT175F1023 1 ea
IN-4 Clogged Filter Switch E-V1 AHU5 EXISITNG 3-WAY VALVE 24VAC 2/10VDC CONTROL - FAILS OPEN BELIMO B217B+LF-SR 1 ea
PANEL H EXISTING 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
Wired To Fan Starter
E-DM1 N.O. IN-2 Mixed Air Temp IN-1 Discharge Air Temperature RSPL ROOM SENSOR WITH REMOTE ADJUSTMENT AND OVERRIDE AUTOMATED LOGIC RSPL 0 ea
IN-5 Freezestat Alarm
T1 2 ZN253 ZN253 AUTOMATED LOGIC ZN253 0 ea
AO-1 – Mixing Dampers 1
DAS-1
-
3 Pg-7 DTS-1
+ Pg-7
CFS T E-MAT E-FRZ E-DAT T
HW SF
OA N.C. HI LO DX DA Single Zone Unit (typical of 1)
Run Conditions - Scheduled:
2 1 3
E-DM2 Filter M The unit shall run according to a user definable time schedule in the following modes:
T1 E-V1 AHU-5 A Occupied Mode: The unit shall maintain
Starter
AO-1 – Mixing Dampers T1 2 B
AO-2 – Heating Valve - 1 o A 74°F (adj.) cooling setpoint
3
+
AB
o A 70°F (adj.) heating setpoint.
HWHR Unoccupied Mode (night setback): The unit shall maintain
Existing Relay
HWHS Located @ o A 85°F (adj.) cooling setpoint.
Cooling Unit
DO-2 – Cooling Start /Stop
T2
o A 55°F (adj.) heating setpoint.
Alarms shall be provided as follows:
High Zone Temp: If the zone temperature is greater than the cooling setpoint by
MS OL'S a user definable amount (adj.).
L1
L2
SF
Motor
Low Zone Temp: If the zone temperature is less than the heating setpoint by a
L3
user definable amount (adj.).
FUSE IN-3 Supply Fan Status Demand Limiting - Zone Setpoint Optimization:
E-CS
O 120VAC To lower power consumption, the zone setpoints shall automatically relax when the
H A
E-FRZ
MS
OL'S facility power consumption exceeds definable thresholds. The amount of relaxation
11 12
shall be individually configurable for each zone. The zone setpoints shall automatically
DO-1 Fan Start/Stop CR T2 return to their previous settings when the facility power consumption drops below the
Existing
thresholds.
Supply Fan Motor Starter Control Circuit Zone Setpoint Adjust:
The occupant shall be able to adjust the zone temperature heating and cooling setpoints
at the zone sensor.
Zone Optimal Start:
ZN253 The unit shall use an optimal start algorithm for morning start-up. This algorithm shall
E-TR H N G
Bias Rx Format
Lstat Rnet
minimize the unoccupied warm-up or cool-down period while still achieving comfort
CM-54 Ground T2
To Or From Next
Net + Tx Jumper: Gain1
24 Vac
T1 conditions by the start of scheduled occupied period.
CMnet
Network Module
ARCnet Net - Batt
Pwr
78
Shield
78
- +
Run
Err
Zone Unoccupied Override:
CR
Tens
456
90 1
A timed local override control shall allow an occupant to override the schedule and
456
IN-1
901
78 78 IN-2
Sense
Ones
Thermistor/dry contact
456
901
456
90 1
place the unit into an occupied mode for an adjustable period of time. At the expiration
+12V 0-5Vdc
23 23 On
Rnet-
RSPL Rnet+
4
4
3
3
Gnd
2
2
WARMER
1
of this time, control of the unit shall automatically return to the schedule.
O
N
ARC156
Gnd
Elementary School
AUTOMATED LOGIC
Gnd Gnd AO-1 Mixing Dampers Actuator
IN-3
Mixed Air Temperature - Gnd
AO-1
Panel “H” Michigan 48xxx
E-CS Supply Fan Status - 12"
CAUTION:
To Reduce the Risk of Fire
ZN253 Class 2
24 Vac, 50-60 Hz Metro Environmental, Inc.
or Electric Shock, Do Not CONTROLLER 20VA, 0.83A
Interconnect the Outputs of 24Vdc, 0.2A, 5W
Different Class 2 Circuits. Use Copper
Gnd Conductors Only DO-2 Cooling Start / Stop AHU-5 & Sequence Of Operation
CFS Clogged Filter Alarm - DO-2
IN-4
CAUTION: DO-1 DO-1 Supply Fan Start / Stop
IN-5 This product was designed Fo Lstat
E-FRZ
Net + Tx
Freezestat - Open Contact Is Alarm - REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
Gain1 24 Vac
LED to be mounted inside the
T1
CM
net
Net - Batt Pwr
Shield - + Run
BACnet
78 78
On Ten
203
456
IN-1or/dry
456
901
901
s
23
23
2 Thermist
Sen contact
IN-2or/dry
78 78 +12
voided if mounted outside.
456
0-5Vdc
es
456
se contactO
901
901
23 23 Rne
V
12"
Rne
t- 4 n
0-5Vdc
3
1
O2
N3
4
t+
Gnd 2
Communic 1
Gnd M
ations
Rne AR
Rnet
Rne 9 ST Gnd
t+ 19Selection
3
C1 7
+12
t- 6 P
.2 8.
56 6. AO-3
V Inputs: 0
IN-1 k MSTP 4k 8k Gnd
DRAWN BY : TL
Gnd 5V Max 0 Baud
IN-2 AO-2
Gnd Gnd
IN-3 Class 2 AO-1
Gnd CAUTION:
24 Vac,
To Reduce the
50-60 Hz
Risk of Fire
20VA,
Re-Use Existing
or Electric Shock, ZN253
Do Not CONTROLL 0.83A
CAUTION: the ER 24Vdc,
Interconnect
This product 0.2A, 5W
Gnd Outputs of was DO-2
IN-4 Different
designedClass 2 Use
IN-5 to be mounted Copper DO-1
LED Circuits. Power for D.O.'s
Conductor ®
BUSS
inside the
building envelope.
BACnet
s Only
Warranty voided if
CHECKED BY : TS
Locate ZN253 In Existing AHU-5 Temperature
mounted outside.
Economizer:
The controller shall measure the zone temperature and modulate the economizer dampers in sequence to
maintain a setpoint 2°F less than the zone cooling setpoint. The outside air dampers shall maintain a minimum
adjustable position of 20% (adj.) open whenever occupied.
The economizer shall be enabled whenever:
Outside air temperature is less than 65°F (adj.).
AND the outside air temperature is less than the return air temperature.
AND the supply fan status is on.
The economizer shall close whenever:
Mixed air temperature drops from 45°F to 40°F (adj.).
Elementary School
OR on loss of supply fan status.
Michigan 48xxx
OR the freezestat (if present) is on.
Metro Environmental, Inc.
AHU-5 Sequence Continued
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
25 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
E-SAT EXISTING SUPPLY AIR TEMPERATURE SENSOR ALERTON TS2020BT 1 ea
E-TR 120 / 24VAC 100VA TRANSFORMER W/ CIRCUIT BREAKER FUNCTIONAL DEVICES TR100VA001 1 ea
RSPL WALL TEMP SENSOR WITH ADJUSTMENT AUTOMATED LOGIC RSPL 0 ea
ZN141v+ VAV TERMINAL BOX CONTROLLER AUTOMATED LOGIC ZN141V+ 0 ea
Sequence Of Operation
Run Conditions - Scheduled:
The unit shall run according to a user definable time schedule in the following modes:
AO - Zone Damper
Occupied Mode: The unit shall maintain
AI - Airflow
IN-3 Discharge Air Temperature
Monitor Only o A 74°F (adj.) cooling setpoint
M BI - Zone Override
T E-SAT
o A 70°F (adj.) heating setpoint.
AI - Zone Temp
VAV Terminal T
AHU-5 Supply Air (Typical of One) DA Unoccupied Mode (night setback): The unit shall maintain
AI - Zone Setpoint Adjust
o A 84°F (adj.) cooling setpoint.
Serves West Area Of
Pre-School Wing o A 60°F (adj.) heating setpoint.
High Zone Temp: If the zone temperature is greater than the cooling setpoint by a user definable
amount (adj.).
Low Zone Temp: If the zone temperature is less than the heating setpoint by a user definable
High
amount (adj.).
(with filter)
CAUTION:
Flow
Zone Setpoint Adjust:
To Reduce the Risk of Fire
or Electric Shock, Do Not
Interconnect the Outputs of
Low
The occupant shall be able to adjust the zone temperature heating and cooling setpoints at the zone sensor.
Different Class 2 Circuits.
Rnet
LogiStat
CAUTION:
IN-1 0-5Vdc
The unit shall maintain zone setpoints by controlling the airflow through one of the following:
Therm/dry
456
901
10's 0 5
9 6
between the minimum occupied airflow (adj.) and the maximum cooling airflow (adj.) until the zone is
78
8 7
+ -
2 3 23
MSTP Baud 1 4
456
90 1
1's 0 5
9600 19.2k 38.4k 76.8k
9
8 7
6 78
satisfied.
On
Error 4
4
3
Run
3
2
When the zone temperature is less than the cooling setpoint, the zone damper shall maintain the
Power for D.O.s
Power
®
O
N
Sense
Output
24V Max,
1A Max
AO: 0-10 Vdc
5mA Max Inputs 1 & 2
0-5V, therm, dry
Inputs 3 & 4
Therm, dry
Rx Tx
14VA, 0.58A
26Vdc, 0.1A, 3W
Use Copper
Conductors Only
+12V
Rnet-
Rnet+
minimum required zone ventilation (adj.).
Analog LStat/ZASF CW CCW
24V ac
Shield
Net +
Rnet +
Access
Net -
Rnet -
DO-1
Unoccupied:
+12V
BUS
AO-1
LED
IN-1
Gnd
IN-2
Gnd
Gnd
IN-3
IN-4
Gnd
Gnd
When the zone is unoccupied the zone damper shall control to its minimum unoccupied airflow
(adj.).
When the zone temperature is greater than its cooling setpoint, the zone damper shall modulate
E-TR H N G
between the minimum unoccupied airflow (adj.) and the maximum cooling airflow (adj.) until the zone is
11 4 satisfied.
T2
T1
DRAWN BY : TL
CHECKED BY : TS
26 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
DAT DISCHARGE AIR TEMPERATURE SENSOR BAPI ALC/10K-T2-D-18'' 1 ea
E RIB1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
E-CS EXISTING CURRENT SWITCH VERIS E112-700 3 ea
E-DM-1,2 EXISTING DAMPER ACTUATOR 24VAC 2/10VDC CONTROL BELIMO AF24 MFT US 2 ea
IN-1 Return Air Temperature E-RIB-3,4,5 EXISTING 24VAC CONTROL RELAY FUNCTIONAL DEVICES RIBU1C 3 ea
E-TR EXISTING 24VAC TRANSFORMER HONEYWELL N/A 1 ea
E-V1 RTU1 EXISTING 3-WAY 1-1/4'' 6/9VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 1 ea
T RAT
E-ZDM EXISTING ZONE DAMPER ACTUATOR 24VAC 2/10VDC CONTROL BELIMO NB24 MFT US 3 ea
RF RAT RETURN AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 1 ea
EA N.C. RA RSPL ZONE SENSOR WITH ADJUSTMENT AND OVERRIDE BUTTON AUTOMATED LOGIC RSPL 0 ea
SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
E-DM-2 M E-SMK
3 1 2
E-CS
IN-7 – Return Fan Status Interlock Wiring By Unit Mfr. 277 AO-4 – Zone 2 Control 2/10vdc
R\W
AO-1 Mixing Dampers 2/10vdc 72 + 5 Typical of 2 Zones
R/W DO-2 – Return Fan Start/Stop E-ZDM Controlled As 1
Starter 3 1 2
24V
177 AO-3 – Zone 1 Control 2/10vdc
R\W
E-DM-1 5
3 1 2 DO-4 – Cooling 2nd Stage E-ZDM 3 1 2 177
DO-3 – Cooling 1st Stage R\W
AO-1 Mixing Dampers 2/10vdc 72 + 5
N.O.
R/W
3 1 2 E-ZDM
24V
DX
Cold N.C. IN3 – Discharge Air Temperature
Deck
T
SF
Typical of 2 Zones
OA N.C.
Controlled As 1 DA
Trips @ 38F
M Auto Reset
MS OL'S
L1 E-CS
IN-6 – Supply Fan Status HW
208/230 Hot
VAC L2 MTR
L3 Deck N.O.
DO-1 – Supply Fan Start/Stop
Starter BI - Zone Override
IN-8 Pump Status
+
T1 HWHS
3 Gnd 1 + IN-1 Tx
2 + IN-2 BACnet
Discharge Air Temperature
4 IN-3
3 Gnd
CM-63
5 IN-4 Shield
4 + IN-3 Rx To Or From Next
6 Gnd
5 + IN-4
Net-
ARCnet Network Module
7 IN-5 Net+
6 Gnd
IN-6 7 + IN-5 BT485
SE6104a
8
Supply Fan Status 8 + IN-6 12
9 Gnd
9 Gnd DO-6
10 IN-7 12 11
Heating Pump Start / Stop E-Rib #5
Return Fan Status 10 + IN-7 CONTROL MODULE DO-6
10 Wire To Enable Heating Pump
11 IN-8 11
Heating Pump Status 11 + IN-8 DO-5
12 Gnd 12 Gnd Universal Input 10 9 E-Rib #4 T2
DO-5 2nd Stage Cooling Start / Stop
1 + IN-9
Mode Select
Outputs 9 8 Wire To Enable 2nd Stage Cooling Y2
1 IN-9 mA DO-4
2 + IN-10
24V Max, 3A Max
8 7 E-Rib #3 T2 Rc
2 IN-10
Thermistor/
DO-4 1st Stage Cooling Start / Stop
3 Gnd dry contact/
RTD 7 6 Wire To Enable 1st Stage Cooling Y1
3 Gnd Caution: DO-3
Inputs: All Volts To Reduce the Risk of Fire 6 5
E-Rib #2 T2 Rc
10V Max, 20mA Max
or Electrical Shock, Do Not DO-3 R/F Start /Start
Odd Even
interconnect the Outputs of 5 4 Wire To Enable Return Fan G1
Different Class 2 Circuits. DO-2
T2 T
S/F Fan Start / Stop E-Rib #1
4 3
Auto Off On DO-2
3
2
DO-1
2
1 T1 T2
Wire To Enable Supply Fan
T
G Elementary School
DO-1
1 Michigan 48xxx
1 Gnd
Logistat
Stat
MSTP Baud
8
Metro Environmental, Inc.
76.8k
2 Temp
Select AO-4
7
Zone 2 Damper actuator 2/10vdc
Sw Gnd Rnet
3
Temp
38.4k
BACnet Mode AO-4 +
Gnd 8
7 6 RTU-1 Control
WARMER
4 LS5v
Sw 19.2k MSTP
AO-3 Zone 1 Damper actuators 2/10vdc
LogiStat Run Gnd 6 5
5 Gnd AO-3 +
LS5v Port 5
6 Rn+ 9600 ARC156
AO-2
4
Heating Valve 0/20mA REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
COOLER
Rnet 7 Rn-
Gnd
Rnet+ AO-2 + 3
Gnd 4 3
Local Access Error
2
8 +12V Rnet- Gnd 2 AO-1 Mixing Dampers 2/10vdc DRAWN BY : TL
Sense
MANUAL
AO-1 + 1
Rnet+
Rnet-
+12V
OCCUPIED ON
Gnd
78
N
23
23
Unoccupied Mode:
During the unoccupied mode the fan remains off. Below 40F outdoor air temperature the heating coil valve
will modulate and the heating pump will cycle to maintain a low limit plenum temperature of 50F (adj.).
Note: The heating system piping is filled with an unknown glycol mixture.
Elementary School
Michigan 48xxx
Metro Environmental, Inc.
RTU-1 Sequence of Operation Continued
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
29 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
DAT DISCHARGE AIR TEMPERATURE SENSOR BAPI ALC/10K-2-D-8'' 1 ea
DM DAMPER MOTOR 24VAC 2/10VDC CONTROL - FAIL CLOSED BELIMO LF24-SR US 1 ea
E RIB1,2,3 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 3 ea
E-CS EXISTING CURRENT SWITCH VERIS E112-800 2 ea
E-FRZ EXISTING FREEZESTAT INVENSYS TC-5232 1 ea
In-1 – Return Air Temperature E-TR EXISTING 24VAC TRANSFORMER HONEYWELL N/A 1 ea
Gravity Relief E-V1 RTU2 EXISTING VALVE ACTUATOR INVENSYS MP-5210 1 ea
Damper MAT MIXED AIR TEMPERATURE SENSOR BAPI ALC/10K-2-D-8'' 1 ea
N.C. PANEL I 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
T RSPL ROOM SENSOR WITH ADJUSTMENT AND OVERRIDE AUTOMATED LOGIC RSPL 0 ea
SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
EA RA BI - Zone Override
AI - Zone Temp
T
SF HW
OA DX SA
Filter M
N.C.
IN-4 Fan Status
E-CS
Black
120v
Com White
DO-1 Fan Start / Start Red
Starter
(Not Used)
E-CS
IN-5 – Pump Status
AO-2 Heating Valve 5/10vdc Yellow + E-V1
Blue _ Motor
RTU-2 Starter
C NC
HWHR DO-2 Pump Start /Stop
NO
MS OL'S
L1
208/230
HWHS VAC L2 MTR
L3
E-CS
® Class 2 On Off
208/24vac FUSE
+ Gnd
+
Gnd
Aux Power Out BACnet
Over ARCNET156 KBaud
24Vac, 50-60 Hz
20VA, 0.83A 24V ac E-TR L1 L2 G
Gnd +5V Use Copper
Conductors Only
O 120VAC
Select Power
1 IN-1 T2 H A
Return Air Temperature +24V
Batt -
T1 OL'S
2 IN-2
Mixed Air Temperature IN-1, IN-2: Pulse Count Ability CR2032
+ MS
3 Gnd 1 + IN-1 Tx
4 IN-3 2 + IN-2 BACnet CM-56
Discharge Air Temperature 3 Gnd Shield
Supply Fan Status
5
6
IN-4
Gnd
4
5
+ IN-3
+ IN-4
Net-
Rx
ARCnet
To Or From Next DO-2- Pump S/S
T2
Pump Motor
Network Module
Pump Status
7 IN-5
IN-6
6
7
Gnd
+ IN-5
Net+
BT485 E-Rib #2
Starter Control
SE6104a
8
Freezestat - Open Contact Is Alarm 8 + IN-6 12
9 Gnd
9 Gnd DO-6
10 IN-7 12 11
10 + IN-7 CONTROL MODULE DO-6
11 IN-8 11 10
11 + IN-8 DO-5
12 Gnd 12 Gnd Universal Input 10 9
Stat 76.8k
MSTP Baud
8
12"
AO-4
3 Sw Gnd Rnet
Select
Gnd 8
7 Metro Environmental, Inc.
RSPL 4 LS5v
Temp
38.4k
BACnet Mode AO-4 + 7 AO-3
6
Sw 19.2k MSTP
RTU-2 Control
WARMER Class 2
5 Gnd AO-3 + 5 +
Gnd
Aux Power+5V
Out Over ®
BACnet
ARCNET156
20VA,
0.83A
On Off Gnd
24V ac
LS5v Port 4 Heating Valve 5/10vdc Sele
ct
IN-1, IN-2: Pulse
+24
KBaud Use
Copper
Batt
Conductor
-
Power
Rnet
+ IN-2
2 Gn
Gnd 4
Shie
et
3 ld
d R
COOLER 4 + IN-3
12"
1 d 12
+ IN-7 CONTROL MODULE DO-6
Rnet- 2 0 + IN-8
11
Gn Universal
11
10
Gnd 2
12 Thermi Input DO-5
Outputs
8 +12V
d
1 + IN-9 Mode Select Caution: 9
AO-1 stor/ mA 24V Max,
Sense
AO-1 + 1
Rnet+
Gn 3A Max DO-4
+12V
or Electrical
OCCUPIED ON +12V Module Address 1 10V Max, 20mA/ VoltsOd Eve 6
Format Max RTD
d n
Shock, Do Not
interconnect the
DO-3
5
4
OutputsAuto
of Off DO-2
10's 1's On 3
DRAWN BY : TL
Different Class
2 Circuits. 2
DO-1
1 2 3 4
901 901
p Stat 76.8Baud
O
AO Mode Select Sw Select k
38.4
k
BACnet
Gn
AO-4 +
8
d 7
SE6104A
78
78
N
23
23
Sense
Rne Gn
Rnet+
Access r
Rnet-
+12V
t+ Module For 2
Gnd
AO-1 +
d 1
78
78
23
23
456 456 N 20m
Made in USA+12 10V
A
V
30 of 46
Cooling Stage:
Single Zone Unit (typical of 1)
The controller shall measure the zone temperature and stage the cooling to maintain its cooling setpoint. To
Run Conditions - Scheduled:
prevent short cycling, the stage shall have a user definable (adj.) minimum runtime.
The unit shall run according to a user definable time schedule in the following modes:
Occupied Mode: The unit shall maintain
The cooling shall be enabled whenever:
o A 74°F (adj.) cooling setpoint
Outside air temperature is greater than 60°F (adj.).
o A 70°F (adj.) heating setpoint.
AND the economizer (if present) is disabled or fully open.
Unoccupied Mode (night setback): The unit shall maintain
AND the zone temperature is above cooling setpoint.
o A 85°F (adj.) cooling setpoint.
AND the supply fan status is on.
o A 55°F (adj.) heating setpoint.
AND the heating is not active.
Alarms shall be provided as follows:
High Zone Temp: If the zone temperature is greater than the cooling setpoint by a user definable Heating Coil Pump
amount (adj.). During the occupied mode the heating coil pump will be enabled anytime the outdoor temperature falls below
Low Zone Temp: If the zone temperature is less than the heating setpoint by a user definable 55F (adj.). Pump status is monitored via existing motor starter current switch. An alarm will be generated if an
amount (adj.). abnormal condition occurs.
Alarms shall be provided as follows:
Zone Setpoint Adjust: Pump Failure: Commanded on, but the status is off.
The occupant shall be able to adjust the zone temperature heating and cooling setpoints at the zone sensor.
Pump in Hand: Commanded off, but the status is on.
Zone Optimal Start: Pump Runtime Exceeded: Status runtime exceeds a user definable limit
The unit shall use an optimal start algorithm for morning start-up. This algorithm shall minimize the
unoccupied warm-up or cool-down period while still achieving comfort conditions by the start of Heating Coil Valve:
scheduled occupied period. The controller shall measure the zone temperature and modulate the heating coil valve to maintain its heating
setpoint.
Zone Unoccupied Override: The heating shall be enabled whenever:
A timed local override control shall allow an occupant to override the schedule and place the unit into an Outside air temperature is less than 65°F (adj.).
occupied mode for an adjustable period of time. At the expiration of this time, control of the unit shall AND the zone temperature is below heating setpoint.
automatically return to the schedule. AND the supply fan status is on.
AND the cooling is not active.
Freeze Protection: The heating coil valve shall open whenever the freezestat (if present) is on.
If a freezestat condition occurs the fan will shut down and the controller will generate an alarm. The
freezestat is set at 35F (adj.) if tripped manual reset is required to return the rooftop unit to normal Economizer:
service. The controller shall measure the zone temperature and modulate the economizer dampers in sequence to
maintain a setpoint 2°F less than the zone cooling setpoint. The outside air dampers shall maintain a minimum
Supply Fan : adjustable position of 20% (adj.) open whenever occupied.
The supply fan shall run anytime the unit is commanded to run, unless shutdown on safeties. To prevent The economizer shall be enabled whenever:
short cycling, the supply fan shall have a user definable (adj.) minimum runtime. Existing current switch Outside air temperature is less than 65°F (adj.).
monitors fan status. AND the outside air temperature is less than the return air temperature.
Alarms shall be provided as follows: AND the supply fan status is on.
Supply Fan Failure: Commanded on, but the status is off. The economizer shall close whenever:
Supply Fan in Hand: Commanded off, but the status is on. Mixed air temperature drops from 45°F to 40°F (adj.).
Supply Fan Runtime Exceeded: Status runtime exceeds a user definable limit (adj.). OR on loss of supply fan status.
OR the freezestat (if present) is on.
The outside and exhaust air dampers shall close and the return air damper shall open when the unit is off. If
Optimal Start Up is available, the mixed air damper shall operate as described in the occupied mode except that
the outside air damper shall modulate to fully closed.
31 of 46
Minimum Outside Air Ventilation - Fixed Percentage:
The outside air dampers shall maintain a minimum position (adj.) during building occupied hours and be
closed during unoccupied hours.
Unoccupied Mode:
During the unoccupied mode the fan remains off. Below 40F outdoor air temperature the heating coil valve
will modulate and the heating pump will cycle to maintain a low limit plenum temperature of 50F (adj.).
Note: The heating system piping is filled with an unknown glycol mixture.
Elementary School
Michigan 48xxx
Metro Environmental, Inc.
RTU-2 Sequence of Operation Continued
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
32 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
DAT DISCHARGE AIR TEMPERATURE SENSOR BAPI ALC/10K-2-D-8'' 1 ea
E-CS EXISTING CURRENT SWITCH VERIS E112-700 2 ea
E-DM1 EXISTING DAMPER MOTOR 24VAC 2-POSITION W/ AUX SW. BELIMO AF24-S-US 1 ea
E-DPS EXISTING CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH INVENSYS PC-301 1 ea
E-FRZ EXISTING FREEZESTAT DPST INVENSYS TC-5232 1 ea
E-RIB1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
E-V1 SF-1 EXISTING 3-WAY 3/4'' VALVE 0/20MA CONTROL INVENSYS MPR-5413 1 ea
E-V1SF1 EXISTING 24VAC 3-WAY 3/4'' 4/20MA CONTROL INVENSYS MP-5413 1 ea
PANEL J 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
DO-1 OA Dampers
IN-1 – Discharge Air Temperature
E-DM1 E-DPS
T2 PDS
1 2 T DAT
SF HW
OA N.C. SA
E-CS
IN-3 – Fan Status
O 120VAC
HWHR DO-3 – Pump Start/Stop L3
® Class 2 On Off
208/24vac
+ Gnd
+
Gnd
Aux Power Out BACnet
Over ARCNET156 KBaud
24Vac, 50-60 Hz
20VA, 0.83A 24V ac E-TR L1 L2 G
Gnd +5V Use Copper
Conductors Only
Select Power
1 IN-1 T2
Discharge Air Temperature +24V
Batt -
T1
2 IN-2 IN-1, IN-2: Pulse Count Ability
OA Damper Status CR2032
+
3 Gnd 1 + IN-1 Tx
2 + IN-2 BACnet
Supply Fan Status
4 IN-3
3 Gnd
CM-62
5 IN-4 Shield
Pump Status 4 + IN-3 Rx To Or From Next
6 Gnd
5 + IN-4
Net-
ARCnet Network Module
7 IN-5 Net+
6 Gnd
Clogged Filter Switch
IN-6 7 + IN-5 BT485
SE6104a
8
9 Gnd 8 + IN-6 12
9 Gnd DO-6
10 IN-7 12 11
10 + IN-7 CONTROL MODULE DO-6
11 IN-8 11 10
11 + IN-8 DO-5
12 Gnd 12 Gnd Universal Input 10 9
5 Gnd
LS5v Port
Run AO-3 + 5 4
+
Gnd
Aux Power+5V
Out
Sele
ct
IN-1, IN-2: Pulse
+24
Over
BACnet
ARCNET156
KBaud
®
60 Hz
20VA,
0.83A
Use
Copper
Batt
Conductor
-
Power
On Off Gnd
24V ac
Supply Fan SF-1 With Reheat Coil
6 Rn+ 9600 ARC156 Count
V
1 + IN-1Ability
CR20
s Only
32 + Tx
Gnd
Gnd 4 AO-2 2 +
3
Gn IN-2
d
4 + IN-3
BACn
Shie
et
ld R
12"
1 d 12
+ IN-7 CONTROL MODULE DO-6
Rnet- 2 0 + IN-8
11
Gn Universal
11
10
Gnd 2
12 Thermi Input DO-5
Outputs
8 +12V
d
1 + IN-9 Mode Select Caution: 9
AO-1 stor/ mA 24V Max,
Sense
AO-1 +
Rnet+
Gn 3A Max DO-4
+12V
Volts or Electrical
+12V 1 1 6
Module Address Format 10V Max, 20mA/
Max RTD
Od Eve
d n
Shock, Do Not
interconnect the
DO-3
5
4
OutputsAuto
of Off DO-2
10's 1's On
Different Class
2 Circuits.
3
2
DRAWN BY : TL
DO-1
Rnet Gnd
Tem
Logist
at MSTP
1
1 2 3 4
901 901
p Stat 76.8Baud
O
AO Mode Select Sw Select k
38.4
k
BACnet
Gn
AO-4 +
8
d 7
SE6104A
78
78
N
23
23
Sense
Rne Gn
Rnet+
Access r
Rnet-
+12V
t+ Module For 2
Gnd
AO-1 +
d 1
Address mat
Made in USA Rne
CHECKED BY : TS
Rnet 10's 1 1's 1 2 AO Mode0-
t- 90 901 O
3 4 0- Select
78
78
23
23
456 456 N 20m
Made in USA+12 10V
A
V
33 of 46
Supply Fan SF-1 with Reheat (Typical of One)
Supply fan will be started and stopped from the DDC controller based on occupied and unoccupied
schedules.
Existing current switch will monitor the Supply fan status. If an abnormal condition occurs an alarm will be
generated by the controller.
Outside inlet air damper motor will be interlocked with the DDC controller to prove open before the fan is
started.
When the outdoor temperature drops below 55F (adj.) the heating coil pump will start. Existing current
switch will monitor the pump. If an abnormal condition occurs the controller will generate an alarm.
Reheat coil 3-way mixing valve will be controlled to maintain 55F discharge discharge air temperature.
Filter status will be monitored by the DDC controller. An alarm will be generated when the filer is clogged.
When the fan stops the outdoor damper will close. Below 40F (adj.) the heating coil valve will modulate
and the heating pump will cycle to maintain a low limit plenum temperature of 50F (adj.)
Note: The heating system piping is filled with an unknown amount of glycol.
Elementary School
Michigan 48xxx
Metro Environmental, Inc.
Supply Fan SF-1 Sequence of Operation
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
34 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CS CURRENT SENSOR SENVA C-1200 8 ea
E-V1 VUV EXISITNG VALVE FLOATING CONTROL BELIMO N/A 4 ea
Remove 3K Sensor & Install
R3 24VAC DPDT WITH INDICATING LIGHT IDEC RH2B-ULAC24V + SH2B-05 SOCKET 4 ea
New 10k Sensor RSPL RSPL ROOM SENSOR W/SETPOINT AND OVERIDE,RNET AUTOMATED LOGIC RSPL 0 ea
SA SUPPLY AIR TEMPERATURE SENSOR BAPI ALC/10K-2-D-8'' 4 ea
DA ZN551 ZONE CONTROLLER BAPI ZN551 0 ea
803 IN-1 SA Temperature
804
SA
IN-3 SF Status
CS2
SF
500 24c
502 24v
DO-3 HW Valve Open
871
Wired To Packaged Freezestat Low Limit DO-4 HW Valve Close
802
Controls By Unit Mfr. E-V1 1 2 3 4 Valve Supplied With VUV
HWHR
HW
HWHS
DO-2 Cooling
DX
DO-5 Exhaust / Condenser Fan
DO-1 Supply Fan
EF WARMER
EA COOLER
Rnet
OCCUPIED
MANUAL
ON
Self Contained
Mechanical Valve
Existing Perimeter Fin Tube Radiation
IN-4 EF Status AUTOMATED LOGIC
M
CS HWS HWR
Existing
RA
CM-57 VUV-1
CM-58 VUV-2
Mount in VUV
CM-59 VUV-3
CM-60 VUV-4 TX
From Prior Panel per
Lstat Rnet
Tx Jumper: Gain1
Ground 500 201 208-230v
Net +
24 Vac
To Next Panel per 507 202
CMnet
Net - Batt
Pwr
Network Diagram Shield Run
- +
Err
24vac Supplied From
78 78
CR
Unit Ventilator
Tens
456
90 1
456
IN-1
901
78 78 IN-2
Sense
Ones
Thermistor/dry contact
456
901
456
90 1
+12V 0-5Vdc
23 23 On
Rnet-
4
Rnet+
4
3
3
Gnd
2
WARMER 2
1
1
O
N
Rnet + MSTP
COOLER
Rnet Rnet - ARC156
MANUAL
OCCUPIED ON
IN-1
Inputs: 5V Max MSTP Baud
Gnd
AUTOMATED LOGIC
SA Temp 802 IN-2
871 Gnd Gnd
OA/RA Damper 2/10VDC
SF Status IN-3
Gnd
AO-1 812
Outdoor Fan
EF / CF Status Class 2 500
14
R3-1 5
521 CDI 500
Elementary School
24 Vac, 50-60 Hz DO-5 Ex Fan / Cond Fan Start / Stop
CAUTION:
To Reduce the Risk of Fire
ZN551 20VA, 0.83A
24Vdc, 0.2A, 5W
DO-5 813 DO-4 HW Valve Close 13 9 502 Michigan 48xxx
or Electric Shock, Do Not
Interconnect the Outputs of
CONTROLLER Use Copper
Conductors Only
DO-4 802 DO-3 HW Valve Open
Comp Hi Press Lock Out 809
Different Class 2 Circuits. DO-3
871
Gnd Outputs
DO-2 DO-2 Cooling Start / Stop Metro Environmental, Inc.
810 IN-4
24V Max,
1A Max
831 DO-1 Supply Fan
CAUTION: DO-1
IN-5 This product was designed
Power for D.O.'s BUSS
811
LED to be mounted inside the
building envelope. Warranty ® 507 VUV-1, 2, 3 & 4 Control
voided if mounted outside. BACnet TX
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
35 of 46
Unit Ventilator (typical of 4) Compressor Status: Discharge Air Temperature:
Run Conditions - Scheduled: The controller shall monitor the compressor status. The controller shall monitor the discharge air temperature.
The unit shall run according to a user definable time schedule in the Alarms shall be provided as follows: Alarms shall be provided as follows:
following modes: Compressor Failure: Commanded on, but the status is off. High Discharge Air Temp: If the discharge air temperature is
Occupied Mode: The unit shall maintain Compressor in Hand: Commanded off, but the status is on. greater than 120°F (adj.).
A 74°F (adj.) cooling setpoint Compressor Runtime Exceeded: Compressor status runtime Low Discharge Air Temp: If the discharge air temperature is
A 70°F (adj.) heating setpoint. exceeds a user definable limit (adj.). less than 40°F (adj.).
Unoccupied Mode (night setback): The unit shall maintain Condenser Exhaust / Exhaust Air Fan Status: Fan Status:
A 85°F (adj.) cooling setpoint. VUV cooling to remain “Off” The controller shall monitor the CE/EA status. The controller shall monitor the fan status.
A 62°F (adj.) heating setpoint. Alarms shall be provided as follows: Alarms shall be provided as follows:
Alarms shall be provided as follows: CE/EA Failure: Commanded on, but the status is off. Fan Failure: Commanded on, but the status is off.
High Zone Temp: If the zone temperature is greater than the CE/EA in Hand: Commanded off, but the status is on. Fan in Hand: Commanded off, but the status is on.
cooling setpoint by a user definable amount (adj.). CE/EA Runtime Exceeded: Compressor status runtime Fan Runtime Exceeded: Fan status runtime exceeds a user
Low Zone Temp: If the zone temperature is less than the exceeds a user definable limit (adj.). definable limit (adj.).
heating setpoint by a user definable amount (adj.). Heating Coil Valve:
Zone Setpoint Adjust: The controller shall measure the zone temperature and modulate the
The occupant shall be able to adjust the zone temperature heating and heating coil valve to maintain its heating setpoint.
cooling setpoints at the zone sensor. The heating shall be enabled whenever:
Zone Optimal Start: Outside air temperature is less than 65°F (adj.).
The unit shall use an optimal start algorithm for morning start-up. This AND the zone temperature is below heating setpoint.
algorithm shall minimize the unoccupied warm-up or cool-down AND the fan is on.
period while still achieving comfort conditions by the start of The heating coil valve shall open whenever the freezestat (if present)
scheduled occupied period. is on.
Zone Unoccupied Override: Economizer (ASHRAE Cycle II):
A timed local override control shall allow an occupant to override the The controller shall measure the zone temperature and modulate the
schedule and place the unit into an occupied mode for an adjustable mixed air dampers in sequence to maintain the zone cooling setpoint.
period of time. At the expiration of this time, control of the unit shall The outside air dampers shall maintain a minimum adjustable
automatically return to the schedule. position of 20% (adj.) open during heating and ventilation whenever
Freeze Protection: occupied.
The unit shall shut down via unit packaged controls when a low
temperature condition occurs. The economizer shall be enabled whenever:
Supply and Exhaust Fans: Outside air temperature is at least 3°F (adj.) less than the
The supply and exhaust fans shall run on low or medium speeds Zone Temperature.
(adjusted by air balbancer) anytime the unit is commanded to run AND the outside air temperature is less than 65°F (adj.)
unless shutdown on safeties. When the space temperature is 2F (Adj.) The economizer shall close whenever the freezestat (if present) is on.
or higher above the setpoint the supply and exhaust fans will be at high The outside air dampers shall close and the return air damper shall
speed. open when the unit is off. If Optimal Start Up is available the mixed
Cooling: air damper shall operate as described in the occupied mode except
The controller shall measure the zone temperature and energize the that the outside air damper shall modulate to fully closed.
compressor to maintain its cooling setpoint. To prevent short cycling The controller shall monitor the discharge air temperature. Should
the compressor there is a user definable (adj.) minimum runtime. discharge temperature drop below a user definable temperature (adj.), Elementary School
The cooling shall be enabled whenever: the controller shall enable the heating, close the outside damper and Michigan 48xxx
Outside air temperature is greater than 60°F (adj.). open the return damper. Metro Environmental, Inc.
AND the zone temperature is above cooling setpoint. Minimum Outside Air Ventilation - Fixed Percentage: VUV-1, 2, 3 & 4 Sequence Of Operation
AND the fan is on. The outside air dampers shall maintain a minimum position (adj.) REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
during building occupied hours and be closed during unoccupied
DRAWN BY : TL
hours.
CHECKED BY : TS
36 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CS CURRENT SENSOR SENVA C-1200 1 ea
DAT DISCHARGE AIR TEMPERATURE SENSOR BAPI ALC/10K-2-D-8'' 1 ea
DA E-CS2 EXISTING CURRENT SENSOR VERIS E112-708 1 ea
E-FRZ EXISTING FREEZESTAT INVENSYS TC-5232 1 ea
E-DAT E-V1 VUV5 EXISTING VALVE 0/20 MA CONTROL INVENSYS MPR-5613-0-0-3 1 ea
IN-1 Discharge Air Temperature – Cable 4 MAT MIXED AIR TEMPERATURE SENSOR 12' BAPI ALC-10K-2-A-12' 1 ea
RSPL RSPL ROOM SENSOR W/SETPOINT AND OVERIDE,RNET AUTOMATED LOGIC RSPL 0 ea
SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
E-CS2
IN-3 SF Status – Cable 9
SF
Black / Blue
24v
Black E-TR
Com
Cable 10 With Red Tape
IN-5 Freezestat Low Limit – Cable 12 Yellow / White + AO-2 HW Valve 0/20 mA – Cable 7
Red _
Interlock Wires To Fan S/S
E-V1 E-V1
EXISTING
E-FRZ HWHR
HW
HWHS
DX
DO-3 Exhaust Fan – Cable 2
DO-1 Supply Fan – Cable 3
E-MAT
E-DA 1 2 3 4
C NO
HWHR
NC
EF WARMER
HWHS
EA COOLER
Rnet
OCCUPIED
MANUAL
ON Existing Abandoned Unit Ventilator
IN-4 EF Status – Cable 11
(Typical Of Two)
AUTOMATED LOGIC
CS
RA
® Class 2 On Off
208/24vac
+ Gnd
+
Gnd
Aux Power Out BACnet
Over ARCNET156 KBaud
24Vac, 50-60 Hz
20VA, 0.83A 24V ac E-TR L1 L2 G
Gnd +5V Use Copper
Conductors Only
Select Power
1 IN-1 T2
Discharge Air Temperature - Cable 4 +24V - Cable 10
2 IN-2
Batt T1
Mixed Air Temperature - Cable 6 IN-1, IN-2: Pulse Count Ability CR2032
+ With Red Tape
3 Gnd 1 + IN-1 Tx
4 IN-3 2 + IN-2 BACnet
Supply Fan Status - Cable 9 3 Gnd CM-60
5 IN-4 Shield
Exhaust Fan Status - Cable 11 4 + IN-3 Rx To Or From Next
Re-label Cable 10 6 Gnd
5 + IN-4
Net-
ARCnet Network Module
7 IN-5 Net+
6 Gnd
With Black Tape Freezestat - Open Contact Is Alarm - Cable 12 IN-6 7 + IN-5 BT485
SE6104a
8
To Cable 12 9 Gnd 8 + IN-6 12
9 Gnd DO-6
10 IN-7 12 11
10 + IN-7 CONTROL MODULE DO-6
11 IN-8 11 10
11 + IN-8 DO-5
12 Gnd 12 Gnd Universal Input 10 9
Mode Select DO-5
9 8
1 IN-9 1 + IN-9 mA
Outputs
DO-4
24V Max, 3A Max
2 + IN-10 Thermistor/ 8 7
Exhaust Fan Start / Stop - Cable 2 E-Rib #2
2 IN-10 DO-4
3 Gnd dry contact/
RTD 7 6 Wire To Enable Unit Relay R3
3 Gnd Caution: DO-3
Inputs: All Volts To Reduce the Risk of Fire 6 5
E-Rib #1 T2
10V Max, 20mA Max
or Electrical Shock, Do Not DO-3 Cooling Start / Stop - Cable 1
Odd Even
interconnect the Outputs of 5 4 Wire To Enable Unit Relays R11 And R12
Different Class 2 Circuits. DO-2
4 3
SF Fan Start / Stop - Cable 3 E-Rib #3 T2
Auto Off On DO-2
3 2 Wire To Enable Unit Relay R1
DO-1
2 1 T1 T2
DO-1
1
Elementary School
1 Gnd
Logistat
Stat
MSTP Baud
8
Michigan 48xxx
2 Temp 76.8k
Select AO-4
7
3 Sw Gnd
Temp
Rnet
38.4k
BACnet Mode AO-4 +
Gnd 8
7 6
Metro Environmental, Inc.
4 LS5v AO-3
WARMER Sw 19.2k MSTP
LogiStat Run Gnd 6 5
5 Gnd AO-3 +
6 Rn+
LS5v Port
9600 ARC156
5
AO-2
4 Heating Valve Damper 0/20mA - Cable 7 VUV-5 Control
COOLER
Rnet 7 Rn-
Gnd
Rnet+
Error
AO-2 +
Gnd 4
3
3
Local Access
8 +12V Rnet- Gnd 2 AO-1
2 OA/RA Damper 2/10VDC - Cable 8 REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
Sense
AO-1 + 1
Rnet+
MANUAL
Rnet-
+12V
Gnd
78
N
23
23
hours. CHECKED BY : TS
38 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
DAT DISCHARGE AIR SENSOR BAPI ALC/10K-2-D-8'' 23 ea
E-CS EXISTING CURRENT SWITCH VERIS E112-700 46 ea
R1,2,3,4,5 24VAC SPDT RELAYS CORE CVR-11C 115 ea
RSPL ZONE SENSOR WITH ADJUSTMENT AND OVERRIDE BUTTON AUTOMATED LOGIC RSPL 0 ea
ZN551 ZN551 AUTOMATED LOGIC ZN551 0 ea
RA DA
M
IN-2 Compressor Status
DO-4 HPLS Valve
DO-3 Reversing Valve
Existing BI - Zone Override
1 2
HPLS HP HPLS
NC AI - Zone Temp
T
DO-2 Compressor Enable
AI - Zone Setpoint Adjust
IN-1 Fan Status
Existing
1 2
HWS HWR
NO
Network Module
ARCnet Net - Batt
Pwr
Run
Shield - +
78 Err
78 CR
Tens
456
901
456
IN-1
90 1
78 78 IN-2
Sense
Ones
Thermistor/dry contact
456
90 1
456
901
+12V 0-5Vdc
23 23 On
Rnet-
4
Rnet+
RSPL
4
3
3
Gnd
Gnd
2
2
1
1
O
N
Gnd
Rnet + Communications Selection
Rnet
Rnet +
Rnet - Rnet Rnet -
MSTP
ARC156
IN-1
Inputs: 5V Max MSTP Baud
Gnd
DAT Class 2
24 Vac, 50-60 Hz
CAUTION:
To Reduce the Risk of Fire
ZN551 20VA, 0.83A
24Vdc, 0.2A, 5W
DO-5 DO5 Close Perimeter Heating Valve R4 T2
or Electric Shock, Do Not
Interconnect the Outputs of
CONTROLLER Use Copper DO-4 DO4 Open HPLS Water Isolation Valve R5 T2
Conductors Only
DO-3
DO3 Reversing Valve Heat/Cool Mode
Gnd
IN-4
Different Class 2 Circuits.
Outputs
24V Max,
1A Max
DO-2
DO-1
DO2 Compressor S/S Relay R3
R2
T2
T2
Elementary School
CAUTION:
IN-5 This product was designed DO1 Fan S/S Relay R1 T2
Power for D.O.'s BUSS
Michigan 48xxx
Existing
LED to be mounted inside the
building envelope. Warranty ® T1
voided if mounted outside. BACnet
Relays Metro Environmental, Inc.
Water Source Heat Pumps
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
39 of 46
Water Source Heat Pump (typical of 23)
Run Conditions - Scheduled: The heating shall be enabled whenever: Perimeter radiation heating valve will open whenever:
The unit shall run according to a user definable time schedule in the Outside air temperature is less than 65°F (adj.). Outside air temperature is less than 55°F (adj.) and there is a call
following modes: AND the fan is on. for heat greater than 10% in either occupied or unoccupied mode.
Occupied Mode: The unit shall maintain AND the reversing valve is in heat mode.
o A 75°F (adj.) cooling setpoint The cooling shall be enabled whenever:
o A 72°F (adj.) heating setpoint Outside air temperature is greater than 60°F (adj.).
AND the fan is on.
Unoccupied Mode (night setback): The unit shall maintain AND the reversing valve is in cool mode.
o A 85°F (adj.) cooling setpoint. On mode change, the compressor shall be disabled and remain off until
o A 62°F (adj.) heating setpoint. after the reversing valve has changed position.
Alarms shall be provided as follows: Alarms shall be provided as follows:
High Zone Temp: If the zone temperature is greater than the Compressor Runtime Exceeded: The compressor runtime
cooling setpoint by a user definable amount (adj.). exceeds a user definable limit (adj.).
Low Zone Temp: If the zone temperature is less than the heating Compressor Status:
setpoint by a user definable amount (adj.). The controller shall monitor the compressor status.
Zone Setpoint Adjust: Alarms shall be provided as follows:
The occupant shall be able to adjust the zone temperature heating and Compressor Failure: Commanded on, but the status is off.
cooling setpoints at the zone sensor. Compressor in Hand: Commanded off, but the status is on.
Zone Optimal Start: Compressor Runtime Exceeded: Compressor status runtime
The unit shall use an optimal start algorithm for morning start-up. This exceeds a user definable limit (adj.).
algorithm shall minimize the unoccupied warm-up or cool-down period Filter Hours:
while still achieving comfort conditions by the start of scheduled The controller shall monitor the fan runtime.
occupied period. Alarms shall be provided as follows:
Zone Unoccupied Override: Filter Change Required: Filter has been in use for more
A timed local override control shall allow an occupant to override the than 2200hr (adj.).
schedule and place the unit into an occupied mode for an adjustable Discharge Air Temperature:
period of time. At the expiration of this time, control of the unit shall The controller shall monitor the discharge air temperature.
automatically return to the schedule. Alarms shall be provided as follows:
Fan: High Discharge Air Temp: If the discharge air temperature is
The fan shall run anytime the unit is occupied, cycles during unoccupied greater than 120°F (adj.).
with a call for heat and cool unless shutdown on safeties. Low Discharge Air Temp: If the discharge air temperature is less
Heating and Cooling - 1 Compressor Stage: than 40°F (adj.).
The controller shall receive a signal from the loop water source monitor Fan Status:
indicating that there is water flow and that the water temperature is The controller shall monitor the fan status.
within acceptable limits for a minimum of two minutes. Alarms shall be provided as follows:
The controller shall measure the zone temperature, open the isolation Fan Failure: Commanded on, but the status is off.
valve and cycle the compressor to maintain its setpoint. To prevent short Fan in Hand: Commanded off, but the status is on.
cycling, the stage shall have a user definable (adj.) minimum runtime. Fan Runtime Exceeded: Fan status runtime exceeds a user
The compressor shall run subject to its own internal safeties and definable limit (adj.). Elementary School
controls. The isolation valve will close when the compressor cycles off. Michigan 48xxx
Metro Environmental, Inc.
Water Source Heat Pump Sequence
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
40 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
E-CS EXISTING CURRENT SWITCH VERIS E112-800 1 ea
E-V1 EXISTING 1-1/2'' 3-WAY MIXING VALVE HONEYWELL N/A 1 ea
HWS HOT WATER SUPPLY TEMPERATURE SENSOR BAPI ALC/10K-2-I-4'' 1 ea
SE6104a SE6104A AUTOMATED LOGIC SE6104A 0 ea
T2
2 1 3 E-V1 HWS
NC C
HWHS MS OL'S
L1
NO To Radiant 208/230
VAC L2 MTR
M Ceiling Panels L3
E-CS
IN-8 – Pump Status
IN-7 Pump Status
E-CS
FUSE
HWS Starter
O 120VAC
H A
OL'S
DO-4 – Radiant Ceiling Loop Pump Start /Stop MS
HWR HWHR
DO-4- Pump S/S
T2 Pump Motor
From Radiant E-Rib #3 Starter Control
Ceiling Panels
AHU-4 Controller
® Class 2 On Off
208/24vac
+ Gnd
+
Gnd
Aux Power Out BACnet
Over ARCNET156 KBaud
24Vac, 50-60 Hz
20VA, 0.83A 24V ac E-TR L1 L2 G
Gnd +5V Use Copper
Conductors Only
Select Power
1 IN-1 T2
Discharge Air Temperature +24V
Batt
-
T1
2 IN-2 IN-1, IN-2: Pulse Count Ability
Supply Fan Status CR2032
+
3 Gnd 1 + IN-1 Tx
4 IN-3 2 + IN-2 BACnet
Pump Status 3 Gnd
5 IN-4 Shield
Clogged Filter Alarm 4 + IN-3 Rx To Or From Next
6 Gnd
5 + IN-4
Net-
ARCnet Network Module
7 IN-5 Net+
6 Gnd
Freezestat Alarm IN-6 7 + IN-5 BT485
SE6104a
8
OA Damper Status 9 Gnd 8 + IN-6 12
9 Gnd DO-6
10 IN-7 12 11
Radiant Ceiling Loop HWS Temperature 10 + IN-7 CONTROL MODULE DO-6
11 IN-8 11 10
Radiant Ceiling Panel Loop Pump Status 11 + IN-8 DO-5
12 Gnd 12 Gnd Universal Input
DO-5
10 9
Radiant Ceiling Panel Loop Pump Start / Stop E-Rib #3
1 IN-9 1 + IN-9 mA
Mode Select
Outputs 9
DO-4
8 Wire To Enable Pump Starter
24V Max, 3A Max
2 + IN-10 Thermistor/ 8 7
E-Rib #2 T2
2 IN-10
3 Gnd dry contact/ DO-4 Heating Pump Start /Start
3 Gnd RTD
Caution:
7
DO-3
6 Wire To Enable Heating Pump
Inputs: All Volts
10V Max, 20mA Max
To Reduce the Risk of Fire
or Electrical Shock, Do Not DO-3
6 5
SF Fan Start / Stop E-Rib #1 T2
Odd Even
interconnect the Outputs of 5 4 Wire To Enable Supply Fan Motor Starter
Different Class 2 Circuits.
Auto Off On DO-2
4
DO-2
3
2
Open OA Damper Motor T2 Elementary School
3
DO-1
DO-1
2 1 T1 Michigan 48xxx
1
Gnd Rnet
Select AO-4
7
Radiant Ceiling Panel Loop Control
3 Sw 38.4k Gnd 8
Temp BACnet Mode AO-4 + 7 6 Radiant Ceiling Heating Valve 2/10vdc
4 LS5v AO-3
Gnd
Sw LogiStat Run
19.2k MSTP
Gnd 6 5 REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
5 AO-3 + 5
6 Rn+
LS5v Port
9600 ARC156
4 Heating Valve 0/20mA
Gnd Gnd 4 AO-2
7 Rn- Rnet+ AO-2 + 3 3
DRAWN BY : TL
Error
8 +12V Rnet-
Local Access
Gnd 2
2 Face and By-Pass Dampers 2/10vdc
AO-1
Sense
AO-1 + 1
Rnet+
Rnet-
+12V
Gnd
Rnet
10's 1's CHECKED BY : TS
1 2 3 4
901 901 O
AO Mode Select
SE6104A
78
78
N
23
23
HWR HWS
E-AQS
M
HW
Cabinet Unit Heater (typical of 13)
Ceiling
RA E-CS DA Run Conditions - Scheduled:
IN-2 Fan Status
The unit shall run according to a user definable time schedule in the following modes:
Starter DO-1 Fan Start/Stop
Occupied Mode: The unit shall maintain a heating setpoint of 68°F (adj.).
E-SSP
IN-1 Space Sensor
T
Unoccupied Mode (night setback): The unit shall maintain a heating setpoint of
55°F (adj.).
Low Zone Temp: If the zone temperature is less than the heating setpoint by a
user definable amount (adj.).
L 120VAC N
Zone Optimal Start:
The unit shall use an optimal start algorithm for morning start-up. This algorithm shall
Existing HWR Pipe minimize the unoccupied warm-up or cool-down period while still achieving comfort
Strap-On
On / Off
Switch
E-R Aquastat conditions by the start of scheduled occupied period.
BLU
YEL E-AQS
FAN
ORN Fan:
Set To Make
@110F (Adj.) The fan will run anytime the zone temperature drops below the heating setpoint and hot
water is available as sensed by the pipe mounted aquastat after relay R is enabled. When
Existing Cabinet Unit Heater Control relay R is disabled the fan will stop.
(Typical of 13)
Heating Coil Valve:
The cabinet unit heaters do not have valves.
CM-27 CM-35
CM-28 CM-36
CM-29 CM-37
CM-30 CM-38
CM-31 CM-39
CM-32
From Prior ARCnet CM-33
Network Controller CM-34 Controller Mounted At CUH
Net +
To Next ARCnet Net - Gnd T2
Network Controller E-TR
Shield 24 Vac T1
Gnd
Rnet+
ZN220
Rnet-
E-SSP +12V
DRAWN BY : TL
CHECKED BY : TS
42 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CS CURRENT SWITCH SENVA C-1200 3 ea
E RIB1 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 3 ea
E-TR EXISTING 24VAC TRANSFORMER HONEYWELL N/A 1 ea
PANEL D 16''X12''X6'' NEMA 1 ENCLOSUE WITH PERF PANEL HOFFMAN A16N126 W/ A16N12PP 1 ea
ZN551 ZONE CONTROLLER AUTOMATED LOGIC ZN551 0 ea
Sequence of Operation
Exhaust fans are started and stopped based on an occupied time schedule.
DDC controller will monitor the exhaust fan statuses via current switches. If an
CS CS CS
abnormal condition occurs the controller will generate an alarm.
Exhaust Fan Circuit 26 Status Exhaust Fan Circuit 28 Status Exhaust Fan Circuit 29 Status
Panel “D”
From Prior ARCnet
12"
Network Controller
CM-45
Net +
To Next ARCnet Gnd T2
Net - E-TR BT485
Net +
Rx
Tx
Fo Lstat
rm Rnet
Jumper:
at
Ground
Network Controller
Gain1 24 Vac
T1
CM
net
Net - Batt Pwr
24 Vac 78
Shield - +
78
CR
Run
ErrThermist
On Ten
Shield 203
456
IN-1or/dry
456
901
901
s
23
23
2 Thermist
Sen contact
IN-2or/dry
78 78 +12
456
0-5Vdc
es
456
se contactO
901
901
23 23 Rne
V
Rne
t- 4 n
0-5Vdc
3
1
O2
N3
4
t+
Gnd 2
Communic 1
Gnd M
ations
Rne AR
Rnet
Rne 9 ST
Gnd t+ 19Selection
3 7
ZN551
CAUTION: the
Interconnect ER
16"
DO-3
Rnet- This product
Gnd Outputs
IN-4 Different
of was
designedClass 2
IN-5 to be mounted
Use
24V
Copper
Max,
Conductor
DO-2
DO-1
LED Circuits. 1A for D.O.'s
Power BUSS
inside the s Only
Max ®
BACnet
RIB T2
building envelope.
Warranty voided if
+12V mounted outside.
WHT/RED WHT/PURP
CS
IN-1 Exhaust Fan Status Circuit 26 IN-1
LED
BUS T1 Locate Control Panel In Electrical Room
Serving The Exhaust Fans
Exhaust Fan
Circuit 26
RIB T2
WHT/RED WHT/PURP Elementary School
Michigan 48xxx
Metro Environmental, Inc.
Exhaust Fans Serving Pre-School Wing
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
DRAWN BY : TL
CHECKED BY : TS
43 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
CS CURRENT SWITCH SENVA C-1200 3 ea
E RIB1 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 1 ea
E-TR EXISTING 24VAC TRANSFORMER HONEYWELL N/A 1 ea
ZN551 ZONE CONTROLLER AUTOMATED LOGIC ZN551 0 ea
Sequence of Operation
Exhaust fans are started and stopped based on an occupied time schedule.
DDC controller will monitor the exhaust fan statuses via current switches. If an
CS CS CS CS
abnormal condition occurs the controller will generate an alarm.
Exhaust Fan Circuit 30 Status Exhaust Fan Circuit 33 Status Exhaust Fan Circuit 31 Status Exhaust Fan Circuit 32 Status
H 120VAC N G H 120VAC N G
Circuit 30 Circuit 31
Existing Existing Toilets
Teachers Classrooms
Manual Starter Lounge Manual Starter
C1-1 C2-1 301 / 302
OL OL
EF EF
H 120VAC N G H 120VAC N G
Circuit 33 Circuit 32
Toilets Toilets
Existing Existing
Classrooms Classrooms
Manual Starter Manual Starter
C1-2 305 / 306 C2-2 303 / 304
OL OL
EF EF
ZN551
Rnet-
+12V
CS
IN-1 Exhaust Fan Status Circuit 30 IN-1
DRAWN BY : TL
CHECKED BY : TS
44 of 46
Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY
H548 COMMAND RELAY WITH CURRENT SWITCH VERIS H548 4 ea
TR3 120/24VAC TRANSFORMER 50VA FUNCTIONAL DEVICES TR50VA005 4 ea
ZN220 DIGITAL CONTROLLER AUTOMATED LOGIC ZN220 0 ea
EF-x
Sequence of Operation
Starter Exhaust fans are started and stopped based on an occupied time schedule.
NC
Gravity
DDC controller will monitor the exhaust fan status via current switch. If an
Damper abnormal condition occurs the controller will generate an alarm.
General Exhaust
H 120VAC N G
Existing
Typical Exhaust Fan Control In The Following Areas:
Manual Starter
Hand EF
OL
Off
Auto
Jumper
1) Preschool West Bathroom.
IN-1 EF-x STATUS 2) Toilets South of Teachers Lounge
TR3 24V
T1
DO-1 EF-x T2
3) Art Room Storage
H548 4) To Be Determined (TBD).
ZN220 CM-xx
Rnet+
ZN220
Rnet-
+12V
Gnd DEV:
IN-2
Gnd EF-xx
DO-2 Elementary School
DO-1 EF-x Start/Stop
DO-1 Michigan 48xxx
BUS T1
Metro Environmental, Inc.
DRAWN BY : TL
CHECKED BY : TS
45 of 46
Summary Bill of Materials Summary Bill of Materials
DID DESCRIPTION MANUFACTURER PART NUMBER QTY DID DESCRIPTION MANUFACTURER PART NUMBER QTY
BT485 END OF LINE SEGMENT CONDITIONER AUTOMATED LOGIC BT485 6 ea SA SUPPLY AIR TEMPERATURE SENSOR BAPI ALC/10K-2-D-8'' 4 ea
CDT COLD DECK AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 1 ea SE6104a SE6104A AUTOMATED LOGIC SE6104A 9 ea
CFS CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH CLEVELAND AFS-222 1 ea SSP STAINLESS STEEL WALL PLATE SENSOR BAPI ALC/10K-2-SP 13 ea
CO2 RETURN AIR DUCT MOUNTED CO2 SENSOR VERIS CDE 1 ea T1 to T6 IMMERSION TEMP SENSOR BAPI ALC/10K-2-I-4'' 6 ea
CR1,2 COOLING RELAY 24VAC DPDT WITH INDICATING LIGHT IDEC RH2B-ULAC24V + SH2B-05 SOCKET 2 ea TR-1 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 1 ea
CS CURRENT SENSOR SENVA C-1200 14 ea TR-1,2 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 2 ea
CS CURRENT SENSOR SENVA C-1200 1 ea TR-1,2,3,4 TRANSFORMER 120/24VAC 100VA FUNCTIONAL DEVICES TR100VA001-28 4 ea
DAT DISCHARGE AIR TEMPERATURE SENSOR BAPI ALC/10K-T2-D-18'' 4 ea TR3 120/24VAC TRANSFORMER 50VA FUNCTIONAL DEVICES TR50VA005 4 ea
DAT DISCHARGE AIR SENSOR BAPI ALC/10K-2-D-8'' 23 ea ZDA EXISTING DAMPER ACTUATOR 120VAC 2/15VDC INVENSYS MP-5430-0-0-3 3 ea
DIAG485 ARC156 DIAGNOSTIC DEVICE AUTOMATED LOGIC DIAG485 1 ea ZDAT ZONE DISCHARGE AIR TEMPERATURE BAPI ALC/10K-T2-D-8'' 3 ea
DM DAMPER MOTOR 24VAC 2/10VDC CONTROL - FAIL CLOSED BELIMO LF24-SR US 1 ea ZN141v+ ZN141V+ AUTOMATED LOGIC ZN141V+ 1 ea
E RIB-1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea ZN220 ZN220 AUTOMATED LOGIC ZN220 18 ea
E RIB-3,4 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea ZN253 ZN253 AUTOMATED LOGIC ZN253 1 ea
E RIB1 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 4 ea ZN551 ZN551 AUTOMATED LOGIC ZN551 32 ea
E RIB1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
E RIB1,2,3 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 3 ea
E-AQS EXISTING STRAP ON AQUASTAT INVENSYS TC-2974 13 ea
E-CS EXISTING CURRENT SWITCH SOLID CORE VERIS E112-708 79 ea
E-CS CR EXISTING CURRENT SWITCH WITH COMMAND RELAY VERIS H948 1 ea
E-CS2 EXISTING CURRENT SENSOR VERIS E112-708 1 ea
E-DA1 EXISTING DAMPER ACTUATOR 120VAC 2/15VDC CONTROL INVENSYS MP-5430 1 ea
E-DA2 EXISTING DAMPER ACTUATOR 120VAC 2/15VDC CONTROL INVENSYS MM-500-0-0-1 1 ea
E-DAT EXISTING DISCHARGE AIR TEMPERATURE SENSOR ALERTON TS-2008BT 1 ea
E-DM-1,2 EXISTING DAMPER ACTUATOR 24VAC 2/10VDC CONTROL BELIMO AF24 MFT US 2 ea
E-DM1 EXISTING DAMPER MOTOR 120VAC 2/15VDC CONTROL INVENSYS MP-5430 3 ea
E-DM1,2 EXISTING DAMPER MOTOR 24VAC 2/10VDC CONTROL BELIMO LF24-SR 2 ea
E-DM2 EXISTING DAMPER MOTOR 120VAC 2/15VDC CONTROL INVENSYS MM-500-0-0-1 2 ea
E-DPS EXISTING CLOGGED FILER DIFFERENTIAL PRESSURE SWITCH INVENSYS PC-301 4 ea
E-FRZ EXISTING FREEZESTAT DPST INVENSYS TC-5232 7 ea
E-MAT EXISTING MIXED AIR TEMPERATURE SENSOR ALERTON TS-2008BT 1 ea
E-R EXISTING 24VAC CONTROL RELAY CORE CVR-11C 24 ea
E-RIB-3,4,5 EXISTING 24VAC CONTROL RELAY FUNCTIONAL DEVICES RIBU1C 3 ea
E-RIB1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 4 ea
E-SAT EXISTING SUPPLY AIR TEMPERATURE SENSOR ALERTON TS2020BT 1 ea
E-SSP ZONE SENSOR STAINLESS STEEL WALL PLATE EXISTING EXISTING 13 ea
E-TR 120/24VAC 75VA TRANSFORMER HONEYWELL AT175F1023 19 ea
E-V1 EXISTING 1-1/2'' 3-WAY MIXING VALVE HONEYWELL N/A 1 ea
E-V1 AHU EXISTING 3-WAY 1-1/4'' 6/9VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 3 ea
E-V1 AHU1 EXISTING 3-WAY 1-1/4'' 6/9VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 1 ea
E-V1 AHU5 EXISITNG 3-WAY VALVE 24VAC 2/10VDC CONTROL - FAILS OPEN BELIMO B217B+LF-SR 1 ea
E-V1 MZ EXISTING 3-WAY 1-1/4'' CV20 GPM 27 0/15VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 1 ea
E-V1 RTU1 EXISTING 3-WAY 1-1/4'' 6/9VDC CONTROL INVENSYS VS-7313-267-4-9 MP-5430-0-0-3 1 ea
E-V1 RTU2 EXISTING VALVE ACTUATOR INVENSYS MP-5210 1 ea
E-V1 SF-1 EXISTING 3-WAY 3/4'' VALVE 0/20MA CONTROL INVENSYS MPR-5413 1 ea
E-V1 VUV EXISITNG VALVE FLOATING CONTROL BELIMO N/A 4 ea
E-V1 VUV5 EXISTING VALVE 0/20 MA CONTROL INVENSYS MPR-5613-0-0-3 1 ea
E-V1SF1 EXISTING 24VAC 3-WAY 3/4'' 4/20MA CONTROL INVENSYS MP-5413 1 ea
E-ZDM EXISTING ZONE DAMPER ACTUATOR 24VAC 2/10VDC CONTROL BELIMO NB24 MFT US 3 ea
ER1,2 EXISTING 24VAC CONTROL RELAY CORE CVR-11C 2 ea
H548 COMMAND RELAY WITH CURRENT SWITCH VERIS H548 4 ea
HDT HOT DECK AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 1 ea
HWS HOT WATER SUPPLY TEMPERATURE SENSOR BAPI ALC/10K-2-I-4'' 1 ea
LGR25 LGR25 AUTOMATED LOGIC LGR25 1 ea
M8102 M8102 DDC CONTROLLER AUTOMATED LOGIC M8102 1 ea
MAT MIXED AIR AVG. TEMP. SENSOR BAPI ALC/10K-2-A-24' 4 ea
MX4106 MX4106 AUTOMATED LOGIC MX4106 1 ea
OAT/H OUTSIDE AIR TEMPERATURE AND HUMIDITY SENSOR BAPI ALC/10K-2-H300-O-WP 1 ea
PANEL A 36X30 ENCLOSURE+PERF+KEYLOCKKIT HOFFMAN A-36N30ALP+A36N30MPP+AL12 1 ea
PANEL B EXISTING INVENSYS COMMUNICATIONS PANEL INVENSYS N/A 1 ea
PANEL C 24'' X 24'' ENCLOSURE+PERF PANEL HOFFMAN A24N24ALP + A24N24MPP 1 ea
PANEL D 16''X12''X6'' NEMA 1 ENCLOSUE WITH PERF PANEL HOFFMAN A16N126 W/ A16N12PP 1 ea
PANEL E 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
PANEL F 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea Elementary School
PANEL G 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
Michigan 48xxx
PANEL H EXISTING 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
PANEL I 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea Metro Environmental, Inc.
PANEL J 12' 'X 12'' X 3'' NEMA 1 ENCLOSURE WITH PERF PANEL HOFFMAN B12-P 1 ea
PDT DIFF PRESS TRANSMITTER 0-50 PS1, 0-5 VDC OUT, 24 VDC IN VERIS PWLX03S 1 ea Summary Bill of Materials
PROT485 ARC156 PROTECTION DEVICE AUTOMATED LOGIC PROT485 2 ea
REV: 0 Submittal 2/08/10 JOB NO: Cxxxx
PS POWER SUPPLY 24VAC IN 24VDC OUT KELE DCP-1.5W 1 ea
R1,2,3,4,5 24VAC SPDT RELAYS CORE CVR-11C 115 ea DRAWN BY : TL
R3 24VAC DPDT WITH INDICATING LIGHT IDEC RH2B-ULAC24V + SH2B-05 SOCKET 4 ea
RAT RETURN AIR TEMPERATURE BAPI ALC/10K-T2-D-18'' 2 ea CHECKED BY : TS
REP485 REPEATER AUTOMATED LOGIC REP485 2 ea
RSPL ROOM SENSOR WITH ADJUSTMENT AND OVERRIDE AUTOMATED LOGIC RSPL 37 ea
46 of 46