Professional Documents
Culture Documents
INTRODUCTION
1.1 GENERAL:
Buildings & houses are one of the oldest construction activities of human
beings. The construction technology has advanced since the beginning from primitive
construction technology to the present concept of modern house buildings. The present
construction methodology for buildings calls for the best aesthetic look, high quality &
fast construction, cost effective & innovative touch.
1
1.2.2 Steel Buildings:
A steel building is a metal structure fabricated with steel for the internal support
and for exterior cladding, as opposed to steel framed buildings which generally use other
materials for floors, walls, and external envelope. Steel buildings are used for a variety of
purposes including storage, work spaces and living accommodation.
Timber Buildings are more feasible in areas where wood materials are easily
accessible, wood construction is often considered to be the cheapest and best approach for
small housing structures. Wooden or timber buildings are constructed in western
countries where temperatures are too low. In wooden buildings the members such as
beams, columns and roofs are made of wood. The wooden buildings may be in thatched,
gypsum and ply wood sheeting etc.
Steel is the material of choice for design because it is inherently ductile and
flexible. It flexes under extreme loads rather than crushing and crumbling. Structural
steel’s low cost, strength, durability, design flexibility, adaptability and recyclability
continue to make it the material of choice in building construction. Today’s structural
steel framing is bringing grace, art and function together in almost limitless ways and is
offering new solutions and opportunities to create challenging structures, which were
once thought impossible. Steel structures have reserve strength. Simple “stick” design in
the steel framings allows construction to proceed rapidly from the start of erection.
1.3.1 Conventional Steel Buildings:
2
1.3.2 Pre Engineered Steel Buildings:
Pre Engineered Steel Buildings are manufactured or Produced in the plant itself.
The manufacturing of structural members is done on customer requirements. The detailed
structural members are designed for their respective location and are numbered, which
cannot be altered; because members are manufactured with respect to design features.
These components are made in modular or completely knocked condition for
transportation. These materials are transported to the customer site and are erected.
Welding and cutting process are not performed at the customer site. No manufacturing
process takes place at the customer site.
The main objective of the feasibility study is to prepare a report of Pre Engineered
steel building for using Staad Pro V8i Software. The report contains all necessary data,
information collected from field visits, plant visits, company visits. In general scope of
work include the following
In the present study, Pre Engineered buildings concept is relatively new technique
that are used to design from low rise to high rise multilevel parking and Industrial
buildings for manufacturing plants . The ware house are designed using Staad Pro
software for the design results and are executed in Auto cad for the section particulars.
The design is done accordingly the customer requirements.
In the Design Process the frame data is assembled based on number of frame
members, number of joints, number of degrees of freedom, the conditions of restraint and
3
the elastic properties of the members. Based on this, the data is stored and member
section properties are computed.
The feasibility Report prepared at the end of visits and designs of the project
components compiles and presents the data/information collected, findings, projects
layout, main design parameters and economic indicators of the project. The Report has
been organized into separate volumes for easier reference during detailed design phase.
The different volumes are enumerated below.
This volume contains Drawing Layouts, Sections and list of figures and
Drawings.
4
CHAPTER 2
2.1.1 Introduction:
5
manufacturers have developed pre-calculated tables for different structural elements in
order to allow designers to select the most efficient I beams size for their projects.
6
2.1.2 Features and Advantages
Features:
Pre-engineered buildings are generally low rise buildings however the maximum
eave height can go up to 25 to 30 meters. Low rise buildings are ideal for offices, houses,
showrooms, shop fronts etc. The application of pre-engineered buildings concept to low
raise buildings is very economical and speedy. Buildings can be constructed in less than
half the normal time especially when complemented with the other engineered sub
systems.
The most common and economical type of low rise buildings is a building
with ground floor and two intermediate floor plus roof. The roof of low rise buildings
may be flat or sloped. Intermediate floors of low rise buildings are made of mezzanine
systems. Single storied houses for living take minimum time for construction and can be
built in any type of geographical location like extreme cold hilly areas, high rain prone
areas, plain land obviously and extreme hot climatic zones as well.
7
Advantages:
Reduction in Construction Time:
Buildings are typically delivered in just a few weeks after approval of drawings.
Foundation and anchor bolts are cast parallel with finished, ready for the site bolting. In
India the use of PEB will reduce total construction time of the project by at least 50%.
This also allows faster occupancy and earlier realization of revenue.
Lower Cost:
Due to the systems approach, there is a significant saving in design,
manufacturing and on site erection cost. The secondary members and cladding nest
together reducing transportation cost.
Flexibility of Expansion:
Buildings can be easily expanded in length by adding additional bays. Also
expansion in width and height is possible by pre designing for future expansion.
Larger Spans:
Buildings can be supplied to around 80M clear spans.
Quality Control:
As buildings are manufactured completely in the factory under controlled
conditions the quality is assured.
Low Maintenance:
Buildings are supplied with high quality paint systems for cladding and steel to
suit ambient conditions at the site, which results in long durability and low maintenance
costs.
8
Architectural Versatility:
Building can be supplied with various types of fascias, canopies, and curved eaves
and are designed to receive pre cast concrete wall panels, curtain walls, block walls and
other wall systems.
Adding to these, there is no mess of sand and cement, power savings, walkable
ceilings, progressive and non-progressive panel systems for walls. A poor man can be
provided with a home created under strict quality control and having a longer life span,
with greater safety against natural disasters like earthquakes and cyclones.
Moreover, it is possible to create the building in required form and shape. And the
system approach renders a holistic way of thinking at one platform for consultants,
designers, architects, and builders. Thus it tends to achieve a perfect harmony among
various stringent specifications and aesthetic requirements in a most economical way.
9
In nutshell, the benefits may be summarized as under
• Weather proof and fire hazards.
• Optimized design of steel reducing weight.
• International Quality Standards
• Seismic & Wind pressure resistant.
• Quality design, manufacturing and erection, saving around 30-40% of project time. Quick
delivery and Quick turn-key construction.
• Pre-painted and has low maintenance requirement.
• Erection of the building is fast.
• The building can be dismantled and relocated easily.
• Future extensions can be easily accommodated without much hassle.
• Increased Life cycle performance and cost competitiveness
• Environment–friendly structures
• Better rainwater harvesting through gutters and down-take arrangements
• Lighter weight; savings in foundation cost of 10-20 percent
• The building can be dismantled and relocated easily
• Easy integration of all construction materials
• Energy efficient roof and wall system using insulations.
• Suitability for Hilly regions and other geographically difficult areas
• Unlimited architectural possibilities
Almost every conceivable building use has been achieved with PEB, the most
common applications are industrial, institutional and commercial.
10
PEB concept has acted as a catalyst in the infrastructure development of the
country. Single storied houses for living take minimum time for construction and can be
built in any type of geographic location like extreme cold hilly areas, high rain prone
areas, plain land, extreme hot climatic zones etc.
2.2PROFILE OF PEB
All over the world, pre-engineered building system or PEB system is becoming an
eminent segment in pre-engineered construction industry. It has become possible because
pre-engineered building system encompasses all the characteristics that are compatible to
modern demands viz. speed, quality and value for money. Pre-engineered buildings find
many pre-engineered construction applications, which could be intrinsic and high-end.
11
2.2.1 PEB prospect in the world:
PEB concept has been very successful and well established in North America,
Australia and is presently expanding in U.K and European countries. PEB construction is
30 to 40% faster than masonry construction. PEB buildings provide good insulation effect
and would be highly suitable for a tropical country like India. PEB is ideal for
construction in remote & hilly areas. A recent survey by the Metal Building Associations
(MBMA) shows that about 60% of the non-residential low rises building in USA are pre-
engineered buildings.
Although PEB systems are extensively used in industrial and many other non-
residential constructions worldwide, it is relatively a new concept in India. These
concepts were introduced to the Indian markets lately in the late 1990’s with the opening
up of the economy and a number of multi nationals setting up their projects. India has an
installed steel capacity of 35 to 40 million tones & apparent steel consumption is around
27 to 30 million tones. The current pre-engineered steel building manufacturing capacity
is 0.35 million tone’s per annum. The industry is growing at the compound rate of 25 to
30 %.
In Telangana PEB has an extensive growth over the years. Most of the Major
companies had production in our state and extending their standards throughout the
nation. Most of the companies had their production fabrication plants in Hyderabad as
12
their base. Kirby building Systems has supplied 3000 PEB buildings in a short span of 6
years.
PEB systems are extensively used in industrial and many other non-residential
constructions worldwide, it is relatively a new concept in India. These concepts were
introduced to the Indian markets lately in the late 1990’s with the opening up of the
economy and a number of multi nationals setting up their projects. The market potential
of PEB’s is 12 lakh Metric tons per annum. The current pre-engineered steel building
manufacturing capacity is 0.35 million tons per annum. The industry is growing at the
compound rate of 25 to 30 %.
2.4FUTURE OF PEB:
The steel structures (SS) market in India is in excess of 4.5 Mn.MT, growing at a
rapid pace of more than 10% p.a. over the past few years. This market has experienced a
higher growth compared to both Indian steel industry as well as Indian construction GDP.
Overall construction sector accounts for majority (greater than 80%) of the steel
structures market (volume terms) in India.
13
2.5 PRE ENGINEERED BUILDINGS Vs CONVENTIONAL BUILDINGS:
DESIGN Quick and efficient: since PEB’s are Each conventional steel structure is
mainly formed by standard sections designed from scratch with fewer
and connections design, time is design aids available to the engineer.
significantly reduced. Basic design
based on international design codes are
used over and over.
14
Specialized computer analysis design Substantial engineering and detailing
programs optimize material required. work is required from the very basic
Drafting is also computerized using is required by the consultant with
standard details to minimize the use of fewer design aids.
project custom details.
ERECTION Both costs and time of erection are Typically, conventional steel
COST AND accurately known based upon buildings are 20% more expensive
TIME
extensive experience with similar than PEB in most of the cases, the
buildings. erection costs and time are not
estimated accurately.
SEISMIC The low weight flexible frames offer Rigid heavy frames do not perform
RESISTANCE higher resistance to seismic forces. well in seismic zones.
15
OVER ALL Price per square meter may be as low Higher price per square meter.
PRICE as by 30% as the conventional
building.
SOURCING Building is supplied complete with all Many sources of supply are there so
AND accessories including erection for a it becomes difficult to co ordinateand
COORDINATIO single “ONE STOP SOURCE”. handle the things.
N
BUILDING Designed to fit the system with Every project requires different and
ACCESSORIES standardized and inter changeable special design accessories and special
parts. Including pre designed flashing sourcing for each item.
and trims. Building accessories are Flashing and trims must be uniquely
mass produced for economy and are designed and fabricated.
available with the building.
FUTURE
EXPANSIONS
Future expansion is very easy and Future expansion is most tedious and
simple. more costly.
16
SAFETY AND Multiple responsibilities can result in
RESPONSIBILT Single source of responsibility is there question of who is responsible when
Y because the entire job is being done by the components do not fit in properly,
one supplier. insufficient material is supplied or
parts fail to perform particularly at
the supplier/contractor interface.
PERFORMANC
E
All components have been specified Components are custom designed for
and designed specially to act together a specific application on a specific
as a system for maximum efficiency, job. Design and detailing errors are
precise fir and peak performance in possible when assembling the diverse
the field. components into unique buildings.
17
CHAPTER 3
18
locations can go up to 1/30 to 1/60. Any practical roof slope is possible as per customer’s
requirement.
Loads are usually classified into two broad groups as dead loads and live loads.
Dead loads (DL) are essentially constant during the life of the structure and normally
consist of the weight of the structural elements. On the other hand, live loads (LL) usually
vary greatly. The weight of occupants, snow and vehicles, and the forces induced by wind
or earthquakes are examples of live loads. The magnitudes of these loads are not known
with great accuracy and the design values must depend on the intended use of the
structure.
Dead Load:
The structure first of all carries the dead load, which includes its own weight, the
weight of any permanent non-structural partitions, built-in cupboards, floor surfacing
materials and other finishes. It can be worked out precisely from the known weights of
the materials and the dimensions on the working drawings.
Live Load:
All the movable objects in a building such as people, desks, cupboards and filing
cabinets produce an imposed load on the structure. This loading may come and go with
the result that its intensity will vary considerably. At one moment a room may be empty,
yetat another packed with people. Imagine the `extra' live load at a lively party.
19
Wind loads:
Wind has become a very important load in recent years due to the extensive use of
lighter materials and more efficient building techniques. A building built with heavy
masonry, timber tiled roof may not be affected by the wind load, but on the other hand
the structural design of a modern light gauge steel framed building is dominated by the
wind load, which will affect its strength, stability and serviceability. The wind acts both
on the main structure and on the individual cladding units. The structure has to be braced
to resist the horizontal load and anchored to the ground to prevent the whole building
from being blown away, if the dead weight of the building is not sufficient to hold it
down. The cladding has to be securely fixed to prevent the wind from ripping it away
from the structure.
Roof load:
Live loads produced by maintenance activities, rain, erection activities, and other
movable or moving loads by not including wind, snow, seismic, crane, or dead loads.
Collateral loads:
The weight of any non-moving equipment or material such ceilings, electrical or
mechanical equipment, sprinkler system, or plumbing.
Auxiliary loads:
Dynamic loads induced by cranes, conveyers, or other material handling systems.
Seismic loads:
Horizontal loads acting in any direction structural systems due to action of an
earthquake.
Floor Live loads:
Loads induced on a floor system by occupants of a building and their furniture,
equipment, etc.
20
3.6 BAY SPACING:
The distance between the two adjacent frames of a building is called as a Bay
spacing. The spacing between two frames is a bay. End Bay length is the distance from
outside of the outer flange of end wall columns of centre line of the first interior frame
columns. Interior bay length is the distance between the centre lines of two adjacent
interior main frames Columns. The most economical bay spacing is 7.5m to 8.0m.
However bay length up to 10m is possible.
21
Single Slope:
It has two columns with different heights having Roof sloping on both the
columns.
Multi Gable:
Multi gable has two or more spans where no intermediate columns are used. The
columns are added to the extended width and columns are not placed at the ridge lines.
Roof Systems:
It has straight columns with Roof having supports are not by TPCA.
Lean To:
Lean to slopes is used extremely for an extending to a building on either side with
short span. The rafters rest on column designed for lean to on one side and rests on the
main column of the building.
Canopy:
Canopies are used in case of open ends where there is an easy access. There are
columns in straight path having roof extended to a large length.
3.8 SUBSYSTEMS
Major companies use standard components and designs to manufacture a wide
range of structural subsystems according to customers' requirements. These structural
subsystems fulfill the requirements of two type’s viz. Aesthetic and Functional. They
produce a large number of structural subsystems according to exact specifications as the
strength of the pre-engineered building system depends largely on various incorporated
structural subsystems. Subsystems are available for following structures
Endwall roof extensions consist of end wall panel, Roof panel, Gable trim, soffit
panel, and end wall rafter. The endwall is extended to an extent under end wall panel
support.
22
Sidewall Roof Extension:
The sidewall roof extension has the same assembly but the soffit panels are above
the Roof Extension Rafter.
Centre Curved Fascia:
The centre curved fascia consist Backup panel, soffit panel. It is an assembly of
Cap flashing, Fascia panel with valley gutter or eave gutter on the rafter with rigid frame
support.
Bottom Curved Fascia:
The entire assembly of Centre curved fascia contains for the Bottom curved
Fascia a slight change in Connection of wall panel to Frame.
23
CHAPTER 4
COMPONENTS OF PEB
4.1 INTRODUCTION
• Primary components
• Secondary components
• Sheeting (or) cladding
• Accessories
24
4.2 PRIMARY COMPONENTS
Main framing:
Main framing basically includes the rigid steel frames of the building. The PEB
rigid frame comprises of tapered columns and tapered rafters (the fabricated tapered
sections are referred to as built-up members). The tapered sections are fabricated using
the state of art technology wherein the flanges are welded to the web. Splice plates are
welded to the ends of the tapered sections. The frame is erected by bolting the splice
plates of connecting sections together.
All rigid frames shall be welded built-up "I" sections or hot-rolled sections. The
columns and the rafters may be either uniform depth or tapered. Flanges shall be
connected to webs by means of a continuous fillet weld on one side. All endwall roof
beams and endwall columns shall be coldformed "C" sections, mill-rolled sections, or
built-up "I" sections depending on design requirements. Plates, Stiffeners etc., all base
plates splice plates, cap plates, and stiffeners shall be factory welded into place on the
structural members.
Built- up “I” section to build primary structural framing members (Columns and Rafters)
Columns:
The main purpose of the columns is to transfer the vertical loads to the
foundations. However a part of the horizontal actions (wind action) is also transferred
through the columns.
Basically in pre-engineered buildings columns are made up of I sections which are most
economical than others. The width and breadth will go on increasing from bottom to top
of the column. I section consists of flanges and web which are made from plates by
welding.
25
Rafter
Rafter:
A rafter is one of a series of sloped structural members (beams) that extend from the
ridge or hip to the wall-plate, down slope perimeter or eave, and that are designed to support the
roof deck and its associated loads.
Purlins, Grits and Eave struts are secondary structural members used as support
to walls and roof panels. Purlins are used on the roof, Grits are used on the walls and
Eave struts are used at the intersection of the sidewall and the roof. They are supplied
with minimum yield strength of 34.5 KN/m. Secondary members act as struts that help in
resisting part of the longitudinal loads that are applied on the building such as wind and
earthquake loads and provide lateral bracing to the compression flanges of the main
frame members for increasing frame capacity. Purloins, Grits and Eave struts are
available in high grade steel conforming to ASTM 607 Grade 50 or equivalent, available
in 1.5 mm, 1.75 mm. 2.0 mm, 2.25 mm, 2.5 mm and 3.0 mm thickness. They come with a
pre-galvanized finish, or factory painted with a minimum of 35 microns (DFT) of
corrosion protection primer.
Purlins and girts shall be cold-formed "Z" sections with stiffened flanges. Flange
stiffeners shall be sized to comply with the requirements of the latest edition of AISI.
26
Purlins and Girts:
Purlins and girts shall be roll formed Z sections, 200 mm deep with 64 mm
flanges shall have a 16 mm stiffening lip formed at 45˚ to the flange. Purlins and girts
shall be cold-formed "Z" sections with stiffened flanges. Flange stiffeners shall be sized
to comply with the requirements of the latest edition of AISC. Purlin and girt flanges
shall be unequal in width to allow for easier nesting during erection. They shall be pre
punched at the factory to provide for field bolting to the rigid frames. They shall be
simple or continuous span as required by design. Connection bolts will install through
the webs, not flanges
Eave Struts
Eave Struts shall be unequal flange cold-formed "C" sections. Eave struts are 200
mm deep with a 104 mm wide top flange, a 118 mm wide bottom flange, both are formed
parallel to the roof slope. Each flange has a 24 mm stiffener lip.
27
Bracings
The Cable bracing is a primary member that ensures the stability of the building
against forces in the longitudinal direction such as wind, cranes, and earthquakes.
Diagonal bracing in the roof and sidewalls shall be used to remove longitudinal
loads (wind, crane, etc.) from the structure. This bracing will be furnished to length and
equipped with bevel washers and nuts at each end. It may consist of rods threaded each
end or galvanized cable with suitable threaded end anchors.
The sheets used in the construction of pre- engineered buildings are composed of the
following:
Base metal of either Galvalume coated steel conforming to ASTM a 792 M grade
345B or Aluminium conforming to ASTM B 209M .Galvalume coating is 55%
Aluminium and about 45% Zinc by weight. An exterior surface coating on painted sheets
of 25 microns of epoxy primer with a highly durable polyester finish.
28
Figure 4.4: Sheetings
4.5 ACCESSORIES
Anchor bolts:
Bolts used to anchor the structural members to the concrete floor, foundation or
other support. This usually refers to the bolts at the bottom of all columns.
Anchor bolts are manufactured with circular steel rods having threading portion at
the top for bolting and bent up at the bottom for Foundation.
Turbo ventilators:
A Turbo Ventilator is a free spinning roof ventilator that works on free wind
energy. When there is a difference in thermal or wind pressure between the inside and
outside of the building, the air is forced to move through the opening of the Turbo
Ventilator in order to maintain an equilibrium condition.
The benefits of using turbo ventilators are that it improves air circulation and cuts
off the suffocation. Eco friendly turbo ventilator involves no operating cost, are free from
maintenance and are has trouble free operations.
29
Figure 4.5.2: Turbo ventilators
Sky lights may consists of poly carbonate sheets which is translucent sheet that
allows maximum light and minimum heat. High strength translucent panels are glass fiber
reinforced polyester, high strength and may be either and it provides with an estimated
light transmitting capacity of 60%. High strength translucent panels match standard panel
profiles, are 1/16” thick, weigh 8 ounces per square foot, and are white with a granitized
top surface.
Insulated translucent panels are available in type 1, "R" panel and standing seam
profiles only. Damper, Standard size is 3000 mm long with a throat opening of 300 mm.
Louvers:
Standard Louvers shall have a 26 gauge galvanized steel frame, painted, with 26
gauge blades. Heavy Duty Louver frames shall be 18 gauge galvanized steel frame,
painted, with 20 gauge blades. Both Standard and Heavy Duty louvers shall be self-
30
framing and self-flashing. They shall be equipped with adjustable or fixed blades as
specified. Nominal sizes shall be 2’-0" x 2’0" x 2'-
0", 3'-0" x 3'-0" 4'-0" x 3'-0", and 3'-0" x 4'-0 ”
Walking doors:
Walk doors are generally 915 mm or 1830 mm wide x 2134 mm high made of 20
gauge electro galvanised steel with a core of polyurethane insulation. Door fixture is
provided.
Aluminium windows:
Designed for installation with wall panel, double slide, self-flashing with pre-
glazed clear glass and removable half insect screen. Standard size is 1 m x 1 m. multiple
windows can be formed by joining the jamb fins together
31
Roof curbs:
Enclosure for ducts or other roof projections. These are 2 mm thick glass fiber
reinforced plastic fitting roof panels and available in opening sizes 600 mm, 900 mm and
1200 mm square.
Fasteners:
Standard fasteners shall be self-drilling screws with metal and neoprene washers.
All screws shall have hex heads and are zinc plated.
32
CHAPTER 5
WAREHOUSE
5.1 INTRODUCTION
Storing goods and materials that require protection from the elements.
Warehouses must be designed to accommodate the loads of the materials to be stored, the
associated handling equipment, the receiving and shipping operations and associated
trucking, and the needs of the operating personnel. The design of the warehouse space
should be planned to best accommodate business Warehouses, defined here, are facilities
that provide a proper environment for the purpose of service requirements and the
products to be stored/handled. The economics of modern commercial warehouses dictate
that goods are processed in minimal turnaround time.
33
Features already now common in warehouse designs are higher bays,
sophisticated materials-handling equipment, broadband connectivity access, and more
distribution networks. A wide range of storage alternatives, picking alternatives, material
handling equipment and software exist to meet the physical and operational requirements
of the warehouse. Warehouse spaces must also be flexible to accommodate future
operations and storage needs as well as mission changes.
34
• Address material handling technologies and business practice, such as "just-in-time"
storage, which have fundamentally changed operation of warehouses and distribution
centers, and will continue to do so.
• Include roof design with built-in extra structural capacity to handle addition of future
rooftop equipment.
• Be designed with fire protection capacity to accommodate storage of materials with a
greater fire hazard, especially needed with high plastic product content or packaging, and
plastic shrink-wrapped pallets.
• Maximize utilization of space while providing adequate circulation paths for personnel
and material handling equipment such as forklift trucks.
• Use higher bays to take advantage of height allowances in the space.
• Optimize layout and configuration for the warehouse operation, including efficient
circulation and material handling and storage processes.
• Relate interior and exterior receiving and shipping operations to the process flow of
goods through the warehouse.
• Receiving and shipping are best separated to avoid congestion at the loading dock areas
in the building, and in the truck maneuvering areas.
• Alternative material handling methods will determine other building aspects, such as aisle
widths, lighting design, need for mezzanine space, fire protection, and egress design.
Businesses will often use different methods of storage handling simultaneously for
different products.
C. Durable/Functional
• Be planned to accommodate loads of stored materials as well as associated handling
equipment.
• Design of warehouses is to be based on the dead and live load requirements of the
structure as it will be built. Snow, wind, and seismic loads shall be considered where they
are applicable. Racking in seismic areas must be built stronger and be better braced.
• Wind uplift can cause great damage to roofs and metal roof copings at the roof edge.
Building codes recognize that wind velocity is greater across open areas, typical for
warehouse zones.
35
• Wind-driven rain can easily penetrate the vast surface areas of the warehouse walls.
Design walls to permit any infiltrating water to evaporate harmlessly without collecting in
the wall cavities or damaging stored product.
• Proper floor types are an important consideration in the design. General warehouse space
should be floored with a concrete slab to carry wheel loads and withstand the abrasion
generated by the continual use of hard rubber and steel-wheeled forklift trucks. Consider
adding hardeners and dust proofers to protect the concrete. Consider using epoxy coating
on concrete floors near battery charging areas.
• Floor flatness and levelness requirements are critical, especially for high ceilinged space
and safe operation of high-lifting equipment.
• Adequate space must be provided on-site for truck maneuvering, truck storage if the
business owns a fleet, car parking for employees and future office space/population
expansion (which might be driven by higher rent for center-city office space), and
landscaped areas.
• Be designed to ensure that no structural member will interfere with the spacing of rail car
doors or truck berths at dock spaces. Dock heights on the truck side of the terminal
should be approximately 4'-4" above the pavement, with appropriate ramps at each truck
berth to bring the height of the truck bed in line with the dock height. Dock heights on the
rail side of the terminal should be approximately 3'-9" above the top of the rail to ensure
that the rail car floor is even with the dock floor. Dock widths and areas inside exterior
doors leading to dock space must be planned for maneuverability of forklift trucks and
other expected types of material handling equipment.
• Dock heights on the truck side of the terminal should be approximately 4'-40" above the
pavement, with appropriate ramps, scissor lifts, or dock levelers at each truck berth to
safely bring the height of the truck bed in line with the dock height.
• Tops of doors should be high enough to accommodate full height pallet handling from the
highest trucks.
• Dock heights on the rail side of the terminal should be approximately 3'-9" above the top
of the rail to ensure that the rail car floor is even with the dock floor.
• Dock widths and areas inside exterior doors leading to dock space must be planned for
maneuverability of forklift trucks and other expected types of material handling
36
equipment. Consider using a non-slip finish on the concrete floor near loading areas for
safety.
D. Energy-Efficient
• Be designed with passive solar concepts, solar geometry, and building load
requirements in mind.
• Possess light colored roof to reflect a large percentage of solar radiation, reducing HVAC
loads, and energy consumption. First cost is also reduced, due to the smaller plant size
required. When a large roof area is anticipated, this effect can be significant, especially
for temperature controlled warehouses. Greater heat reflection will increase worker
productivity in the summer.
• Be planned with interior dock space in colder climates to reduce energy consumption and
provide more tolerable winter working conditions for dock workers.
• Use ceiling mounted fans to reduce heat stratification and provide air movement, thus
increasing worker comfort in both summer and winter. Mount fans above highest forklift
level for worker safety.
• Consider specifying white painted metal roof decking, thereby increasing ceiling surface
reflectivity, lighting efficiency, and worker comfort without any added energy cost.
• Use energy-efficient fixtures, systems, and appliances, e.g., motion sensor instant-on
lighting systems, wherever feasible.
Address the traditional life-safety and health concerns common to all buildings, including
measures to prevent occupational injuries and illnesses (work-related musculoskeletal disorders
(WMSD), trips, falls, etc.), ensure electrical safety, and eliminate exposure to hazardous
materials.
The following operations have historically contributed to significant numbers of warehouse
injuries and are considered to be the most hazardous: docks, powered industrial trucks,
conveyors, materials storage, manual lifting/handling, roof ladders and hatches, and charging
stations.
37
Other serious operational safety problems include inadequate fire safety provisions,
improper blocking of exits and egress paths, chemical exposure, improper use of lockout
procedures, lack of ergonomics, and failure to wear personal protective equipment.
Incorporate proper signage to clearly warn of hazards or to direct personnel to take
precaution. The specific strategy for the warehouses signs must be determined early in the
facility design process.
Possess non-slip surface treatments on floors subject to wetting, such as outdoor docks, to
eliminate slips and falls to personnel.
Be designed with fire sprinkler systems engineered to cover the specific commodity
classification in the specific storage configuration for the planned warehouse. The
adequacy of the sprinkler system must be evaluated when changes occur that can increase
the hazard classification, such as introducing a new product line, using a different
packaging material, or changing from wood pallets to plastic pallets.
Include appropriate security systems in corporated into the overall warehouse design.
F. Health/Comfort
Provide proper ventilation under all circumstances.
Provide local exhaust for restrooms, kitchens, janitor's closets, copy rooms,
batterycharging areas, etc.
Consider installing CO2 sensors to provide real time monitoring of air quality.
Integrate day lighting with the electric lighting system.
Allow for natural lighting where possible. Provide lighting controls that turn off
lights when sufficient daylight exists. Consider dimming controls that continuously
adjust lighting levels to respond to daylight conditions.
• Consider the different natural lighting designs for warehouses.
• Minimize HVAC system noise in occupied space.
• Use furnishings, chairs, and equipment that are ergonomically designed and
approved for that use.
Design equipment and furnishings reflective of healthy work practices in an effort to
eliminate repetitive motions as well as prevent strains and sprains.
38
• Strive to create a 'sense of place' such that the warehouse has a unique character
that engenders a sense of pride, purpose, and dedication for individual workers and
the workplace community.
G. EMERGING ISSUES
39
• Experts say that new logistical handling systems and greater outsourcing in particular, the
increased use of third-party logistics providers seem to be driving this trend.
• New "flex" warehouses in well landscaped industrial park settings for smaller businesses
is a growing trend. These buildings accommodate small businesses such as contractors,
light industrial fabricators, and mechanics that do not need exposure to heavy retail street
traffic.
• In older industrial areas, small warehouse buildings with low roofs, no longer suitable for
large single commercial users, are being repositioned and renovated as multi-tenant "flex"
warehouse buildings.
• Forces outside the parameters of the normal building project can generate great changes
in warehouse design.
40
CHAPTER 6
DESIGN OF PRE ENGINEERED STEEL BUILDING
6.1 INTRODUCTION
The main framing of PEB systems is analyzed by the stiffness matrix method. The
design is based on allowable stress design (ASD) as per the American institute of Steel
Construction specification or the IS 800. the design program provides an economic and
efficient design of the main frames and allows the user to utilize the program in different
modes to produce the frame design geometry and loading and the desired load
combinations as specified by the building code opted by the user. The program operates
through the maximum number of cycles specified to arrive at an acceptable design. The
program uses the stiffness matrix method to arrive at an acceptable design. The program
uses the stiffness matrix method to arrive at the solution of displacements and forces. The
strain energy method is adopted to calculate the fixed end moments, stiffness and carry
over factors. Numerical integration is used.
41
5. Design the optimum splice location and check to see whether the predicted sizes confirm to
manufacturing constraints.
6. Using the web optimization mode, arrive at the optimum web depths for the next cycle and
update the member data file.
7. At the end of all design cycles, an analysis is run to achieve flange brace optimization.
Frame Geometry:
The program has the capability to handle different types of frame geometry as
follows Frames of different types viz. rigid frames, frames with multiple internal
columns, single slope frames, lean to frames etc; Frames with varying spans, varying
heights and varying slopes etc. Frames with different types of supports viz. pinned
supports, fixed supports, sinking supports, supports with some degrees of freedom
released. Unsymmetrical frames with off centric, unequal modules, varying slopes etc.
User specified purlin and girt spacing and flange brace location.
Frame Loading:
Frame design can handle different types of loadings as described below:
All the building dead loads due to sheeting, purlins etc., and the self-weight of
the frame and Imposed live load on the frame with tributary reductions as well. Wind
loads input such as basic wind speed or basic wind pressure that will be converted to
design wind pressure as per the building code specified by the user and shall be applied to
the different members of the building according to the coefficients mentioned in the codes
prescribed by the user. The standard building codes like MBMA, UBC, ANSI, IS: 875
parts 3 etc are used for this purpose. Crane and non-crane loading can be specified by the
user and the program has the capability to handle these special loads and combine them
with the other loads as required.
Seismic loads corresponding to the different zone categories of various
international codes can also be defined and combined with other load cases as required.
Temperature loads can also be specified in the form of different differential temperature
value on centigrade and specifying the appropriate coefficient for the thermal expansion.
Load combinations with appropriate load factors can be specified by the user as desired.
42
Design of a Pre Engineered Warehouse:
The majority of warehouse buildings are made out of steel for obvious reasons of
high strength/weight ratio. A study, on the Efficient Design of Large span
warehouses/structures, is presented.
Structure with Span larger than 40 m can be regarded as long span structures and
need to be carefully designed keeping a balance of all the aspects like its weight,
deflections (sway) and foundation forces. There are many combinations of designing
large spans, like conventional truss & RCC column combination, truss & steel columns,
Pre-engineered building (PEB) etc.
These days with the concept of PEB, the major advantage we get is the use of high
strength steel plates (usually Fe 350), lighter but high strength cold form purlins, and 550
Map Galvalume profiled sheets. The use of PEB not only reduces the weight of the
structure because high tensile steel grades are used but also ensures quality control of the
structure. In the following study, we have designed a warehouse using this modern
concept of PEB.
STAAD pro features state of the art user interface, visualization tools, powerful
analysis and design engines with advanced finite element (FEM) and dynamic analysis
capabilities. From model generation, analysis and design to visualization and result
verification STAAD pro is the professional first choice. STAAD pro was developed by
43
practicing engineers around the globe. It has evolved over 20 years and meets the
requirements of ISO 9001 certification.
Loads on Structure
Dead load:
Dead loads shall cover unit weight/mass of materials, and parts or components in
a building that apply to the determination of the dead loads in the design of buildings and
shall be considered as per IS: 875 (Part 1) - 1987 according to the densities of the possible
components.
This includes main frames, purlins, girts, cladding, bracing and connections etc.
Live Load:
Imposed loads shall be considered as per IS: 875 (Part 2) – 1987. Live load shall be
considered as 0.75 KN/sum for the analysis and design.
Wind Load:
The basic wind speed and design velocity which shall be modified shall be taken
As per IS: 875 (Part 3) – 1987. The basic wind speed at Hyderabad shall be considered as
44m/sec as per IS: 875 (Part III). This shall be considered for calculating the wind loads.
Analysis shall be carried out by considering future expansions if any which has been
indicated in the building descriptions and critical forces shall be taken for design.
Seismic Load:
Earthquake loads affect the design of structures in areas of great seismic activity.
The proposed structures in this project shall be analyzed for seismic forces.The seismic
zone shall be considered as per IS: 1893-2002 (Part 1). For analysis and design, Zone II
shall be considered as Mysore region falls under this zone as per IS: 1893-2002 (Part 1).
44
Earthquake analysis shall be carried out using STAAD PRO 2007 as per the
provisions of IS: 1893-2002 (Part 1) & IS: 1893-2005 (part 4). The analysis parameters
shall be taken as per the following. The seismic load is considered for Hyderabad location
which falls under Zone II.
• Zone Factor: 0.16
• Importance Factor: 1.00
• Response Reduction Factor: 5
The design under discussion is a 42 meter clear span warehouse for shipping and
docking maintenance. We have designed this warehouse in 3D on STAAD software, for
proper simulation of the load distribution uniformly in three co-ordinates system i.e. X, Y
and Z. Dead, Live, Wind, Temperature, seismic etc have been taken into consideration for
designing of the frames. The structure has been designed under enclosed as well as open
condition for application of wind loads, because of the opening & closing of the large
sized warehouse Door. The Load calculations are done as in the case of a regular frame.
Normally, the critical case governing the designs would be (DL+WL) or (DL+LL)
conditions as the PEB slopes are minor (like 1 in 10).
45
provided with a Bolted connection to the base. All the other Joints would be normally
designed as rigid joints and steel connections are moment connections, transferring the
axial, moment and shear values between the sections connected. In the Wind load
calculations, the design wind pressures should be arrived at after a careful analysis and
combinations of internal and external pressure coefficients or force coefficients, referring
to IS-875 part III latest version. Proper load combinations with Wind, earthquake and
crane loads should be investigated.
Usually, Checking the Combination Stresses and comparing with the limiting
values (in LSD or WSD) is done using interactive software, which calculates the
Exploitation efficiency of the section, i.e., if the Actual Stress/permitted stress is 0.95, it
means that the section is exploited for 95% of its strength. For this, the total weight of the
frame is calculated. A number of trails are done such that sections are designed with
Variables like Flange thickness, Web thickness, Flange Width, Web Depth, so that the
Entire frame becomes theoretically safe, and is of minimum wt checking for deflections is
the next step. Many times sections need to be revised to hold the theoretical maximum
deflections within the permissible ones.
46
subsequently. We need a solution wherein the sway of the frame can be controlled and
the section sizes are also not increased.
The best way we could find is to ‘Brace’ the frame to control the excess
deflection. In the present case we have provided bracing at eave level (braced eave) on
both sides of the structure along the length for this purpose. Span of this Eave bracing is
taken approximately L / 10 of each side. We can observe in the following example that
eave bracing is of a great help in controlling Horizontal deflections and leading to lighter
foundation design. Some Vendors exploit 90% of the section, leaving 10% for probable
lapses in manufacturing, transporting, assembling & erection. But the competition has
made (forced) people believe that there are no lapses anywhere! The Next important step
is to design the welds between the flanges and Webs. Here too, Efficiency of the weld
plays an important part. Hence, PEB manufacturer will avoid any weld at the site,
because a 4.5 mm weld at the shop may be better than 6 or 8 mm weld at the site.
Next step is to design the Field joints (Where the parts are assembled at the site).
The resultant forces are known at the joints; bolted connection, preferably perpendicular
to the plane of frame, to exploit tensile capacity of bolts for BMs rather than the shear
capacities. Hence, Number of bolts required for the connection will reduce. These joints
are also placed at Optimum locations! That is the advantage of pre engineering. The
secondary members like Purlins and Girts are designed as per codes for thin Cold Formed
Sections, with or without lip. One can use many span reducing and Lateral supporting
techniques like sag rods and knee bracings, tie rods to optimize the sections.
47
6.6 WAREHOUSE DESIGN DIMENSIONS
48
Design Dimensions
Length = 60Meters
degrees
Purlins = 7 kg
The total load transferring from these components are 1.0 KN/M2
Live Load is considered from the crane loading and manual loading during erection and is
0.57KN/M2 `according to MBMA code of chapter 4,
49
Risk coefficient, k1 =1
Net wall coefficients (Cp= Cpe+Cpi) for +veCpi and (Cp=Cpe-Cpi) for –veCpi
Net Roof Coefficients (Cp= Cpe+Cpi) for +veCpi and (Cp=Cpe-Cpi) for –veCpi
WINDWARD LEEWARD
1UNI GX 7.4
2 UNI GX 0.411
50
3 UNI Y -6.09, 4 UNI Y -1.64
WINDWARD LEEWARD
MEMBER LOAD
1 UNI GX 4.12
2 UNI GX -3.7
3 UNI Y -9.34
4 UNI Y -4.93
WINDWARD LEEWARD
MEMBER LOAD
1UNI GX -2.47
2UNI GX -2.47
3UNI Y -4.93
4 UNI Y -4.93
51
Wind Load 90degrees–ve internal coefficient
WINDWARD LEEWARD
MEMBER LOAD
1 UNI GX -5.76
2 UNI GX -5.76
Seismic Parameters:
2002) These Load calculations are input into the staad Pro.
52
6.7 STAAD EDITOR:
PAGE NO. 1
****************************************************
*
* STAAD.Pro
* Proprietary Program of
* Time= 17:22:51
* USER ID:
*
****************************************************
1. STAAD SPACE
INPUT FILE: MAAAATV.STD
2. START JOB INFORMATION
3. ENGINEER DATE 22-Feb-2017
53
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 6.37 0.637 0; 3 12.76 1.276 0; 4 25.52 0 0;5
19.15 0.637 0
9. 6 0 -6 0; 7 25.52 -6 0
10. MEMBER INCIDENCES
11. 1 6 1; 2 2 1; 3 2 3; 4 5 3; 5 5 4; 6 7 4
12. DEFINE MATERIAL START
13. ISOTROPIC STEEL
14. E 2.05E+008
15. POISSON 0.3
16. DENSITY 76.8195
17. ALPHA 1.2E-005
18. DAMP 0.03
19. END DEFINE MATERIAL
20. MEMBER PROPERTY AMERICAN
21. 1 6 TAPERED 0.612 0.006 0.9 0.9 0.008 0.612 0.008
22. 2 TO 5 TAPERED 0.612 0.005 0.8 0.8 0.006 0.612 0.006
23. CONSTANTS
24. MATERIAL STEEL ALL
25. SUPPORTS
26. 6 7 FIXED
27. DEFINE WIND LOAD
28. TYPE 1
29. INT 1.004 HEIG 10
30. EXP 1 JOINT 1 TO 7
31. DEFINE 1893 LOAD
32. ZONE 0.1 RF 4 I 1 SS 2 ST 2 DM 3 PX 0.376 PZ 0.376 DT 5
33. SELFWEIGHT 1
34. MEMBER WEIGHT
54
35. 1 TO 6 UNI 8.2 7.61
36. LOAD 1 LOADTYPE SEISMIC TITLE SL +X
Page 1 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 2
38. LOAD 2 LOADTYPE SEISMIC TITLE SL +Z
39. 1893 LOAD Z 1
40. LOAD 3 LOADTYPE DEAD TITLE DL
41. SELFWEIGHT Y -1 LIST 1 TO 6
42. MEMBER LOAD
43. 2 TO 5 UNI GY -8.2
44. LOAD 4 LOADTYPE LIVE REDUCIBLE TITLE LL
45. MEMBER LOAD
46. 2 TO 5 UNI GY -4.6
47. LOAD 5 LOADTYPE WIND TITLE WL +X
48. MEMBER LOAD
49. 1 UNI GX 3.013
50. LOAD 6 LOADTYPE WIND TITLE WL -X
51. MEMBER LOAD
52. 6 UNI GX -0.3012
53. LOAD 7 LOADTYPE WIND TITLE WL+Z
54. MEMBER LOAD
55. 1 6 UNI GZ 4.21
55
56. LOAD 8 LOADTYPE WIND TITLE WL-Z
57. MEMBER LOAD
58. 1 6 UNI GZ -4.21
59. LOAD 9 LOADTYPE WIND TITLE WL +X ROOF
60. MEMBER LOAD
61. 2 3 UNI GX 6.88
62. LOAD 10 LOADTYPE WIND TITLE WL -XROOF
63. MEMBER LOAD
64. 4 5 UNI GX -1.44
65. LOAD 11 LOADTYPE WIND TITLE WL +Z ROOF
66. MEMBER LOAD
67. 2 TO 5 UNI GZ 6.02
68. LOAD 12 LOADTYPE WIND TITLE WL-ZROOF
69. MEMBER LOAD
70. 2 TO 5 UNI GZ -1.44
71. LOAD COMB 13 GENERATED INDIAN CODE STEEL_PLASTIC 1
72. 72. 3 1.7 4 1.7
73. LOAD COMB 14 GENERATED INDIAN CODE STEEL_PLASTIC 2
74. 3 1.7 1 1.7
75. LOAD COMB 15 GENERATED INDIAN CODE STEEL_PLASTIC 3
76. 3 1.7 2 1.7
77. LOAD COMB 16 GENERATED INDIAN CODE STEEL_PLASTIC 4
78. 3 1.7 1 -1.7
79. LOAD COMB 17 GENERATED INDIAN CODE STEEL_PLASTIC 5
80. 3 1.7 2 -1.7
81. LOAD COMB 18 GENERATED INDIAN CODE STEEL_PLASTIC 6
82. 3 1.3 4 1.3 1 1.3
83. LOAD COMB 19 GENERATED INDIAN CODE STEEL_PLASTIC 7
84. 3 1.3 4 1.3 2 1.3
85. LOAD COMB 20 GENERATED INDIAN CODE STEEL_PLASTIC 8
86. 3 1.3 4 1.3 1 -1.3
87. LOAD COMB 21 GENERATED INDIAN CODE STEEL_PLASTIC 9
56
Page 2 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 3
88. 3 1.3 4 1.3 2 -1.3
89. LOAD COMB 22 GENERATED INDIAN CODE STEEL_PLASTIC 10
90. 3 1.7 5 1.7
91. LOAD COMB 23 GENERATED INDIAN CODE STEEL_PLASTIC 11
92. 92. 3 1.7 6 1.7
93. LOAD COMB 24 GENERATED INDIAN CODE STEEL_PLASTIC 12
94. 3 1.7 7 1.7
95. LOAD COMB 25 GENERATED INDIAN CODE STEEL_PLASTIC 13
96. 3 1.7 8 1.7
97. LOAD COMB 26 GENERATED INDIAN CODE STEEL_PLASTIC 14
98. 3 1.7 9 1.7
99. LOAD COMB 27 GENERATED INDIAN CODE STEEL_PLASTIC 15
100. 100. 3 1.7 10 1.7
101. LOAD COMB 28 GENERATED INDIAN CODE STEEL_PLASTIC 16
102. 3 1.7 11 1.7
103. LOAD COMB 29 GENERATED INDIAN CODE STEEL_PLASTIC 17
104. 3 1.7 12 1.7
105. LOAD COMB 30 GENERATED INDIAN CODE STEEL_PLASTIC 18
106. 3 1.7 5 -1.7
107. LOAD COMB 31 GENERATED INDIAN CODE STEEL_PLASTIC 19
108. 3 1.7 6 -1.7
109. LOAD COMB 32 GENERATED INDIAN CODE STEEL_PLASTIC 20
110. 3 1.7 7 -1.7
111. LOAD COMB 33 GENERATED INDIAN CODE STEEL_PLASTIC 21
112. 112. 3 1.7 8 -1.7
57
113. LOAD COMB 34 GENERATED INDIAN CODE STEEL_PLASTIC 22
114. 3 1.7 9 -1.7
58
143. LOAD COMB 49 GENERATED INDIAN CODE STEEL_PLASTIC 37
Page 3 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 4
144. 3 1.3 4 1.3 8 -1.3
145. LOAD COMB 50 GENERATED INDIAN CODE STEEL_PLASTIC 38
146. 146. 3 1.3 4 1.3 9 -1.3
147. LOAD COMB 51 GENERATED INDIAN CODE STEEL_PLASTIC 39
148. 3 1.3 4 1.3 10 -1.3
149. LOAD COMB 52 GENERATED INDIAN CODE STEEL_PLASTIC 40
150. 3 1.3 4 1.3 11 -1.3
151. LOAD COMB 53 GENERATED INDIAN CODE STEEL_PLASTIC 41
152. 3 1.3 4 1.3 12 -1.3
153. PERFORM ANALYSIS PRINT ALL
P R O B L E M S T A T I S T I C S
----------------------------------
NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 7/
6/
2
SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER
ORIGINAL/FINAL BAND-WIDTH= 5/ 5/ 18
DOF TOTAL PRIMARY LOAD CASES = 12, TOTAL DEGREES
OF FREEDOM = 30
SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 32022.3 MB
Page 4 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
59
STAAD SPACE
--
PAGE NO. 5
LOADING 1 LOADTYPE SEISMIC TITLE SL +X --
--------
LOADING 2 LOADTYPE SEISMIC TITLE SL +Z
----------
LOADING 3 LOADTYPE DEAD TITLE DL
----------
SELFWEIGHT Y -1.000
ACTUAL WEIGHT OF THE STRUCTURE = 38.772 KN
MEMBER LOAD - UNIT KN METE
MEMBER UDL L1 L2 CON L LIN1
LIN2
2 -8.2000 GY 0.00 6.40
3 -8.2000 GY 0.00 6.42
4 -8.2000 GY 0.00 6.42
5 -8.2000 GY 0.00 6.40
LOADING 4 LOADTYPE LIVE REDUCIBLE TITLE LL
----------
MEMBER LOAD - UNIT KN METE
MEMBER UDL L1 L2 CON L LIN1
LIN2
2 -4.6000 GY 0.00 6.40
3 -4.6000 GY 0.00 6.42 4
-4.6000 GY 0.00 6.42
5 -4.6000 GY 0.00 6.40
LOADING 5 LOADTYPE WIND TITLE WL +X
----------
MEMBER LOAD - UNIT KN METE
MEMBER UDL L1 L2 CON L LIN1
LIN2
60
1 3.0130 GX 0.00 6.00
LOADING 6 LOADTYPE WIND TITLE WL -X
----------
Page 5 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 6
MEMBER LOAD - UNIT KN METE
MEMBER UDL L1 L2 CON L LIN1
LIN2
6 -0.3012 GX 0.00 6.00
LOADING 7 LOADTYPE WIND TITLE WL+Z
----------
MEMBER LOAD - UNIT KN METE
MEMBER UDL L1 L2 CON L LIN1
LIN2
1 4.2100 GZ 0.00 6.00
6 4.2100 GZ 0.00 6.00
LOADING 8 LOADTYPE WIND TITLE WL-Z
----------
MEMBER LOAD - UNIT KN METE
62
4 -1.4400 GZ 0.00 6.42
5 -1.4400 GZ 0.00 6.40
*********************************************************
*
TIME PERIOD FOR X 1893 LOADING = 0.37600 SEC *
SA/G PER 1893= 1.250, LOAD FACTOR= 1.000 *
FACTOR V PER 1893= 0.0143 X 38.77 *
*********************************************************
*
*********************************************************
Page 7 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 8
JOINT LATERAL TORSIONAL
LOAD - 1
63
LOAD (KN ) MOMENT (KN -METE)
FACTOR
- 1.000
----- ------- --------
1 FX 0.104 MY 0.000
4 FX 0.104 MY 0.000
----------- ----------
TOTAL = 0.207 0.000 AT LEVEL
0.000 METE
2 FX 0.108 MY 0.000
5 FX 0.108 MY 0.000
----------- ----------
TOTAL = 0.215 0.000 AT LEVEL
0.637 METE
3 FX 0.133 MY 0.000
----------- ----------
TOTAL = 0.133 0.000 AT LEVEL
1.276 METE
JOINT LATERAL TORSIONAL
LOAD - 2
LOAD (KN ) MOMENT (KN -METE)
FACTOR
- 1.000
----- ------- --------
1 FZ 0.104 MY 0.000
4 FZ 0.104 MY 0.000
----------- ----------
TOTAL = 0.207 0.000 AT LEVEL
0.000 METE
2 FZ 0.108 MY 0.000
5 FZ 0.108 MY 0.000
----------- ----------
64
TOTAL = 0.215 0.000 AT LEVEL
0.637 METE
3 FZ 0.133 MY 0.000
----------- ----------
TOTAL = 0.133 0.000 AT LEVEL
1.276 METE
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 1.03716E-01 0.00000E+00
0.00000E+000.00000E+000.00000E+000.00000E+00
2 1.07519E-01 0.00000E+00
0.00000E+000.00000E+000.00000E+000.00000E+00
3 1.32854E-01 0.00000E+00
0.00000E+000.00000E+000.00000E+000.00000E+00
4 1.03716E-01 0.00000E+00
0.00000E+000.00000E+000.00000E+000.00000E+00
5 1.07519E-01 0.00000E+00 0.00000E+000.00000E+00
0.00000E+00 0.00000E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO.
1
LOADTYPE SEISMIC TITLE SL +X
Page 8 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, April 22, 2015, 05:24 PM
STAAD SPACE
--
PAGE NO. 9
CENTER OF FORCE BASED ON X FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
65
RESULTS)
X = 0.127600002E+02
Y = 0.551931684E+00
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
1 )
SUMMATION FORCE-X = 0.56
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ= -
0.31 ***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING
1 )
SUMMATION FORCE-X = -0.56
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
0.31
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 1)
MAXIMUMS AT NODE
X = 4.49088E-03 5
Y = 2.34130E-03 5
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= -8.32889E-06 4
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
66
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00
0.00
0.28 0.05 0.00 0.00 0.00
-1.22 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
0.28 -0.05 0.00 0.00 0.00
-1.22 111111
FOR LOADING - 2
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 0.00000E+00 0.00000E+00 1.03716E-01 0.00000E+00
0.00000E+000.00000E+00
2 0.00000E+00 0.00000E+00 1.07519E-01 0.00000E+00
0.00000E+000.00000E+00
3 0.00000E+00 0.00000E+00 1.32854E-01 0.00000E+00
0.00000E+000.00000E+00
4 0.00000E+00 0.00000E+00 1.03716E-01 0.00000E+00
0.00000E+000.00000E+00
5 0.00000E+00 0.00000E+00 1.07519E-01 0.00000E+00
0.00000E+00 0.00000E+00
Page 9 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 10
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO.
67
2
LOADTYPE SEISMIC TITLE SL +Z
CENTER OF FORCE BASED ON Z FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = 0.127600002E+02
Y = 0.551931684E+00
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
2 ) SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.56
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.31 MY= -7.09 MZ=
0.00 ***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING
2 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -0.56
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= -0.31 MY= 7.09 MZ=
0.00
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 2)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = 2.30964E+01 3
RX= 1.79927E-01 3
RY= -1.81329E-02 1
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
68
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.28 1.82 -0.07
0.00 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 0.28 1.82 0.07
0.00 111111
FOR LOADING - 3
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 7.32929E-02-3.42818E+01 0.00000E+00 0.00000E+00
0.00000E+00-3.46549E+01
2- 1.46816E-01-5.61464E+01 0.00000E+00 0.00000E+00
0.00000E+00-1.72955E-01
Page 10 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 11
69
3- 2.35546E-07-6.08668E+01 0.00000E+00
0.00000E+000.00000E+00 3.44802E-06
4- 7.32929E-02-3.42818E+01 0.00000E+00
0.00000E+000.00000E+00 3.46549E+01
5 1.46816E-01-5.61464E+01 0.00000E+00 0.00000E+000.00000E+00
1.72948E-01
6 0.00000E+00-3.67809E+00 0.00000E+00
0.00000E+000.00000E+000.00000E+00
7 0.00000E+00-3.67809E+00 0.00000E+00 0.00000E+00
0.00000E+00 0.00000E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO.
3
LOADTYPE DEAD TITLE DL
CENTER OF FORCE BASED ON X FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = -0.222651949E+05
Y = 0.113925477E+01
Z = 0.000000000E+00
CENTER OF FORCE BASED ON Y FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = 0.127600001E+02
Y = 0.421791084E+00
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
3 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -249.08
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
70
MX= 0.00 MY= 0.00 MZ= -
3178.25 ***TOTAL REACTION LOAD( KN METE ) SUMMARY
(LOADING 3 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 249.08
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
3178.25
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 3)
MAXIMUMS AT NODE
X = -2.92226E-01 1
Y = -3.55342E+00 3
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= -4.12263E-03 2
Page 11 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 12
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 -3.68 0.00 0.00 0.00
0.00
-110.50 -120.86 0.00 0.00 0.00
71
241.24 111111
7 0.00 -3.68 0.00 0.00 0.00
0.00
110.50 -120.86 0.00 0.00 0.00
-
241.24 111111
FOR LOADING - 4
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 3.65972E-02-1.52833E+01 0.00000E+00 0.00000E+00
0.00000E+00-1.74722E+01
2- 7.33095E-02-2.83742E+01 0.00000E+00 0.00000E+00
0.00000E+00-8.73384E-02
3- 1.18461E-07-3.06626E+01 0.00000E+00
0.00000E+000.00000E+00 1.72401E-06
4- 3.65973E-02-1.52833E+01 0.00000E+00
0.00000E+000.00000E+00 1.74722E+01
5 7.33095E-02-2.83742E+01 0.00000E+00 0.00000E+00
0.00000E+00 8.73350E-02
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO.
4
LOADTYPE LIVE REDUCIBLE TITLE LL
CENTER OF FORCE BASED ON X FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = -
0.100992291E+05 Y
= 0.578777480E+00
Z = 0.000000000E+00
72
CENTER OF FORCE BASED ON Y FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = 0.127600000E+02
Y = 0.638037989E+00
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
4 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -117.98
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ= -
1505.39 ***TOTAL REACTION LOAD( KN METE ) SUMMARY
(LOADING 4 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 117.98
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
1505.39
Page 12 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 13
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 4)
MAXIMUMS AT NODE
X = -1.47434E-01 1
Y = -1.79250E+00 3
Z = 0.00000E+00 0
RX= 0.00000E+00 0
73
RY= 0.00000E+00 0
RZ= -2.07999E-03 2
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00
0.00
-55.76 -58.99 0.00 0.00 0.00
121.73 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
55.76 -58.99 0.00 0.00 0.00
-
121.73 111111
FOR LOADING - 5
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 9.53517E+00 0.00000E+00
0.00000E+000.00000E+000.00000E+00 1.05837E+01
6 8.54283E+00 0.00000E+00 0.00000E+000.00000E+00
0.00000E+00-7.60673E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO. 5
74
RESULTS)
X = 0.000000000E+00
Y = -0.283532460E+01
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
5 )
SUMMATION FORCE-X = 18.08
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
54.23
75
RZ= -1.06911E-04 4
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 8.54 0.00 0.00 0.00 0.00 -7.61
6.57 0.41 0.00 0.00 0.00
-
21.87 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
2.97 -0.41 0.00 0.00 0.00
-
14.18 111111
FOR LOADING - 6
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
4-9.53200E-01 0.00000E+00 0.00000E+000.00000E+00
0.00000E+00-1.05802E+00
7-8.54000E-01 0.00000E+00 0.00000E+000.00000E+00
0.00000E+00 7.60421E-01
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO.
6
LOADTYPE WIND TITLE WL -X
CENTER OF FORCE BASED ON X FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
76
X = 0.255200001E+02
Y = -0.283532469E+01
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
6 ) SUMMATION FORCE-X = -1.81
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ= -
5.42 ***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING
6 )
SUMMATION FORCE-X = 1.81
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
5.42
Page 14 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 15
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 6)
MAXIMUMS AT NODE
X = -5.98600E-03 5
Y = 4.13629E-03 2
Z = 0.00000E+00 0 RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= 1.06875E-05 1
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
77
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00
0.00
-0.30 -0.04 0.00 0.00 0.00
1.42 111111
7 -0.85 0.00 0.00 0.00 0.00 0.76
-0.66 0.04 0.00 0.00 0.00
2.19 111111
FOR LOADING - 7
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 0.00000E+00 0.00000E+00 1.26300E+01-1.26300E+01
0.00000E+00 0.00000E+00
4 0.00000E+00 0.00000E+00 1.26300E+01-1.26300E+01
0.00000E+00 0.00000E+00
6 0.00000E+00 0.00000E+00 1.26300E+01 1.26300E+01 0.00000E+00
0.00000E+00
7 0.00000E+00 0.00000E+00 1.26300E+01 1.26300E+01
0.00000E+00 0.00000E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO.
7
LOADTYPE WIND TITLE WL+Z
CENTER OF FORCE BASED ON Z FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = 0.127600001E+02
Y = -0.299999835E+01
78
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
7 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 50.52
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= -151.56 MY= -644.64 MZ=
0.00 ***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING
7 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -50.52
Page 15 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 16
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 151.56 MY= 644.64 MZ=
0.00
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 7)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = 6.72542E-01 3
RX= 1.15731E-03 1
RY= 9.80119E-17 4
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
79
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 0.00 12.63 12.63 0.00 0.00
0.00 0.00 12.63 63.15 0.00
0.00 111111
7 0.00 0.00 12.63 12.63 0.00
0.00
0.00 0.00 12.63 63.15 0.00
0.00 111111
FOR LOADING - 8
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 0.00000E+00 0.00000E+00-1.26300E+01 1.26300E+01
0.00000E+00 0.00000E+00
4 0.00000E+00 0.00000E+00-1.26300E+01 1.26300E+01
0.00000E+00 0.00000E+00
6 0.00000E+00 0.00000E+00-1.26300E+01-1.26300E+01 0.00000E+00
0.00000E+00
7 0.00000E+00 0.00000E+00-1.26300E+01-1.26300E+01
0.00000E+00 0.00000E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE
NO.
8
LOADTYPE WIND TITLE WL-Z
CENTER OF FORCE BASED ON Z FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = 0.127600001E+02
80
Y = -0.299999835E+01
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
8 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -50.52
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 151.56 MY= 644.64 MZ=
0.00
Page 16 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
81
STAAD SPACE
-- PAGE NO. 17
***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING
8 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 50.52
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= -151.56 MY= -644.64 MZ=
0.00
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 8)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = -6.72542E-01 3
RX= -1.15731E-03 1
RY= -9.80119E-17 4
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 0.00 -12.63 -12.63 0.00
0.00
0.00 0.00 -12.63 -63.15 0.00
0.00 111111
7 0.00 0.00 -12.63 -12.63 0.00
0.00
0.00 0.00 -12.63 -63.15 0.00
82
0.00 111111
9
X FORCE- X MOM-
83
SUMMATION FORCE-X = 88.23
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ= -
56.29 ***TOTAL REACTION LOAD( KN METE ) SUMMARY
(LOADING 9 )
SUMMATION FORCE-X = -88.23
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
56.29
MAXIMUM DISPLACEMENTS (CM /RADIANS) (LOADING 9)
MAXIMUMS AT NODE
X = 7.40200E-01 2
Y = 4.26202E-01 5
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= -1.37317E-03 1
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00
0.00
46.80 7.58 0.00 0.00 0.00
-
84
204.48 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
41.43 -7.58 0.00 0.00 0.00
187.80 111111
10
X FORCE- X MOM-
85
X = -0.231733736E+05
Y = 0.231990060E+04
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
10 )
SUMMATION FORCE-X = -18.47
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ=
11.78 ***TOTAL REACTION LOAD( KN METE ) SUMMARY
(LOADING 10 )
SUMMATION FORCE-X = 18.47
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 0.00 MY= 0.00 MZ= -
11.78
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 10)
MAXIMUMS AT NODE
X = -1.54926E-01 5
Y = 8.92051E-02 2
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= 2.87407E-04 4
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/
EXT MZ/
INT FX INT FY INT FZ INT MX INT MY
INT MZ
86
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00
0.00
-8.67 -1.59 0.00 0.00 0.00
39.31 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
-9.79 1.59 0.00 0.00 0.00
42.80 111111
11
X FORCE- X MOM-
87
CENTER OF FORCE BASED ON Z FORCES ONLY (METE).
(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE
RESULTS)
X = 0.127600001E+02
Y = 0.638000003E+00
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
11 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 154.40
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 98.51 MY= -1970.10 MZ=
0.00
88
***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING
11 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -154.40
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= -98.51 MY= 1970.10 MZ=
0.00
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING
11)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = 7.42459E+03 3
RX= 5.78217E+01 3
RY= -5.83200E+00 1
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE
)
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT
MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT
MY
INT MZ
SUPPORT=1
6 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 77.20 512.44 -
23.85 0.00 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 77.20 512.44
23.85
0.00 111111
FOR LOADING - 12
89
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
1 0.00000E+00 0.00000E+00-4.60928E+00-4.89352E-01
4.89352E+00 0.00000E+00
2 0.00000E+00 0.00000E+00-9.23302E+00-3.07767E-03
3.07771E-
02 0.00000E+00
Page 20 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 21
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X
MOM-Y
MOM-Z
3 0.00000E+00 0.00000E+00-9.24750E+00 9.84859E-01-
4.30346E-
07 0.00000E+00
4 0.00000E+00 0.00000E+00-4.60928E+00-4.89352E-01-
4.89352E+00 0.00000E+00
5 0.00000E+00 0.00000E+00-9.23302E+00-3.07760E-03-
3.07758E-
02 0.00000E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR
CASE NO.
12
LOADTYPE WIND TITLE WL-ZROOF
CENTER OF FORCE BASED ON Z FORCES ONLY
(METE). (FORCES IN NON-GLOBAL DIRECTIONS WILL
INVALIDATE
RESULTS)
X = 0.127600000E+02
Y = 0.638000001E+00
90
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING
12 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -36.93
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= -23.56 MY= 471.25 MZ=
0.00 ***TOTAL REACTION LOAD( KN METE ) SUMMARY
(LOADING 12 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 36.93
SUMMATION OF MOMENTS AROUND THE ORIGIN
MX= 23.56 MY= -471.25 MZ=
0.00
MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING
12)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = -1.77598E+03 3
RX= -1.38311E+01 3
RY= 1.39503E+00 1
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE
)
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT
MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT
MY
INT MZ
SUPPORT=1
91
6 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 -18.47 -122.58
5.71 0.00 111111
7 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 -18.47 -122.58 -
5.71
0.00 111111
Page 21 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 22
LOAD COMBINATION NO. 13
GENERATED INDIAN CODE STEEL_PLASTIC 1
LOADING- 3. 4.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 14
GENERATED INDIAN CODE STEEL_PLASTIC 2
LOADING- 3. 1.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 15
GENERATED INDIAN CODE STEEL_PLASTIC 3
LOADING- 3. 2.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 16
GENERATED INDIAN CODE STEEL_PLASTIC 4
LOADING- 3. 1.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 17
GENERATED INDIAN CODE STEEL_PLASTIC 5
LOADING- 3. 2.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 18
92
GENERATED INDIAN CODE STEEL_PLASTIC 6
LOADING- 3. 4. 1.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 19
GENERATED INDIAN CODE STEEL_PLASTIC 7
LOADING- 3. 4. 2.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 20
GENERATED INDIAN CODE STEEL_PLASTIC 8
LOADING- 3. 4. 1.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 21
GENERATED INDIAN CODE STEEL_PLASTIC 9
LOADING- 3. 4. 2.
FACTOR - 1.30 1.30 -1.30
Page 22 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 23
LOAD COMBINATION NO. 22
GENERATED INDIAN CODE STEEL_PLASTIC 10
LOADING- 3. 5.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 23
GENERATED INDIAN CODE STEEL_PLASTIC 11
LOADING- 3. 6.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 24
GENERATED INDIAN CODE STEEL_PLASTIC 12
LOADING- 3. 7.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 25
93
GENERATED INDIAN CODE STEEL_PLASTIC 13
LOADING- 3. 8.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 26
GENERATED INDIAN CODE STEEL_PLASTIC 14
LOADING- 3. 9.
FACTOR - 1.70 1.70
LOAD COMBINATION NO.
27 GENERATED INDIAN
CODE STEEL_PLASTIC
15 LOADING- 3.
10.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 28
GENERATED INDIAN CODE STEEL_PLASTIC
16 LOADING- 3. 11.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 29
GENERATED INDIAN CODE STEEL_PLASTIC 17
LOADING- 3. 12.
FACTOR - 1.70 1.70
LOAD COMBINATION NO. 30
GENERATED INDIAN CODE STEEL_PLASTIC 18
LOADING- 3. 5.
FACTOR - 1.70 -1.70
Page 23 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 24
LOAD COMBINATION NO. 31
GENERATED INDIAN CODE STEEL_PLASTIC 19
LOADING- 3. 6.
FACTOR - 1.70 -1.70
94
LOAD COMBINATION NO. 32
GENERATED INDIAN CODE STEEL_PLASTIC 20
LOADING- 3. 7.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 33
GENERATED INDIAN CODE STEEL_PLASTIC 21
LOADING- 3. 8.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO.
34 GENERATED INDIAN
CODE STEEL_PLASTIC
22 LOADING- 3.
9.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 35
GENERATED INDIAN CODE STEEL_PLASTIC
23 LOADING- 3. 10.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 36
GENERATED INDIAN CODE STEEL_PLASTIC 24
LOADING- 3. 11.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 37
GENERATED INDIAN CODE STEEL_PLASTIC 25
LOADING- 3. 12.
FACTOR - 1.70 -1.70
LOAD COMBINATION NO. 38
GENERATED INDIAN CODE STEEL_PLASTIC 26
LOADING- 3. 4. 5.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 39
GENERATED INDIAN CODE STEEL_PLASTIC 27
LOADING- 3. 4. 6.
FACTOR - 1.30 1.30 1.30
95
Page 24 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, Feb 22, 2017, 05:24 PM
STAAD SPACE
--
PAGE NO. 25
LOAD COMBINATION NO. 40
GENERATED INDIAN CODE STEEL_PLASTIC 28
LOADING- 3. 4. 7.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 41
GENERATED INDIAN CODE STEEL_PLASTIC 29
LOADING- 3. 4. 8.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 42
GENERATED INDIAN CODE STEEL_PLASTIC
30 LOADING- 3. 4. 9.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 43
GENERATED INDIAN CODE STEEL_PLASTIC 31
LOADING- 3. 4. 10.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 44
GENERATED INDIAN CODE STEEL_PLASTIC 32
LOADING- 3. 4. 11.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 45
GENERATED INDIAN CODE STEEL_PLASTIC 33
LOADING- 3. 4. 12.
FACTOR - 1.30 1.30 1.30
LOAD COMBINATION NO. 46
GENERATED INDIAN CODE STEEL_PLASTIC 34
LOADING- 3. 4. 5.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 47
96
GENERATED INDIAN CODE STEEL_PLASTIC 35
LOADING- 3. 4. 6.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 48
GENERATED INDIAN CODE STEEL_PLASTIC 36
LOADING- 3. 4. 7.
FACTOR - 1.30 1.30 -1.30
Page 25 of 28C:\Users\Ranjith\Desktop\MAAAATV.anl
Wednesday, April 22, 2015, 05:24 PM
STAAD SPACE
--
PAGE NO. 26
LOAD COMBINATION NO. 49
GENERATED INDIAN CODE STEEL_PLASTIC 37
LOADING- 3. 4. 8.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 50
GENERATED INDIAN CODE STEEL_PLASTIC 38
LOADING- 3. 4. 9.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 51
GENERATED INDIAN CODE STEEL_PLASTIC 39
LOADING- 3. 4. 10.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 52
GENERATED INDIAN CODE STEEL_PLASTIC 40
LOADING- 3. 4. 11.
FACTOR - 1.30 1.30 -1.30
LOAD COMBINATION NO. 53
GENERATED INDIAN CODE STEEL_PLASTIC 41
LOADING- 3. 4. 12.
FACTOR - 1.30 1.30 -1.30
97
154. FINISH
*********** END OF THE STAAD.Pro RUN
***********
98
CHAPTER 7
PRODUCTION
7.1 INTRODUCTION
Pre Engineered Steel Buildings are tailor made buildings which are those
fully manufactured in the factory after designing. This fabrication is done in a
controlled environment with latest technology. The production is done under
standard conditions. The Raw material required is imported from major companies
like Tata BlueScope to all the companies in India.
99
The design and final processing inspection is done for production, ready for
shipment in completely knocked Down (CKD) conditions.
100
Secondary Framing:
Purlins and girts shall be cold-formed "Z" sections with stiffened flanges.
Flange stiffeners shall be sized to comply with the requirements of the latest edition
of AISI. Purlin and girt flanges shall be unequal in width to allow for easier nesting
during erection. They shall be pre punched at the factory to provide for field bolting
to the rigid frames. They shall be simple or continuous span as required by design.
Connection bolts will install through the webs, not flanges.
Bracing:
Diagonal bracing in the roof and sidewalls shall be used to remove
longitudinal loads (wind, crane, etc.) from the structure. This bracing will be
furnished to length and equipped with bevel washers and nuts at each end. It may
consist of rods threaded each end or galvanized cable with suitable threaded end
anchors. If load requirements so dictate, bracing may be of structural angle and/or
pipe, bolted in place.
Welding:
Welding is a fabrication or sculptural process that joins materials, usually
metals. In Pre Engineered Steel Buildings the hot rolled steel sections are subjected
to submerged arc welding. Shielding gas is used in order to protect the welding
region.
Welding is done by passing the Steel plates into the welding machine, which
welds along the joints. In PEB the Tapered sections are welded, but at some
locations manual welding is done. Double side welding is preferred according to
Indian Code but Single side Welding is much beneficent because it increases the
Quality of steel sections. Single side welding is more economical, all manufactures
follow the American code which states Single side welding.
Base plates are welded to base of columns for the structural strength. These
base plates are provided with bolt holes. Anchor bolt dimensions are taken into
account for Base plate preparation.
101
Anchor Bolts:
Anchor bolts are manufactured with circular steel rods having threading
portion at the top for bolting and bent up at the bottom for Foundation. These are
bent at 90 degrees for embedding into the soil. The dimensions for Anchor bolts are
taken from support reactions of the columns.
Surface Preparation:
The surface of columns and rafters are prepared in order to protect it from
rusting. Abrasive paper is used to scrub the top layers of columns and rafters in order
to remove accumulated rust on the top of the sections. This is old method, it is done
manually. Advancement technologies avoided manual procedure and brought Sand
blasting and short blasting into existence.
Sand blasting:
Sand Blasting is a method in which sand is blown with high velocities to the
members. This is blown with sand particularly with 2 to 4 mm thick sand and surface
is cleared.
Short Blasting:
Short blasting is a latest process in which members are sent into the machine
and hit with iron balls of 3mm thick under a huge velocity. Periodical removal of
rust is done in case of short blasting. Short blasting is observed as more efficient
surface cleaning process
Varnishing or Painting:
Normally the primary and secondary steel are coated with one coat (35
microns) of red oxide paint without any special treatment to steel. However, if some
special paint has to be applied to steel in order to give better anti-corrosion
properties etc. then the steel members have to be shot-blasted and then coated with
the special paints.
102
CHAPTER 8
ERECTION
8.1 INTRODUCTION
Erection Drawings:
Erection drawings provide the field erection crew (raising gang) with the
roadmap of how to erect (put together) the steel assemblies after they are delivered
to the field. Essentially, they are a set of instructions on how to put the puzzle pieces
together. Every assembly shipped to the field is given a shipping piece number to
identify it. This number is noted on the drawing and is also stenciled onto the actual
assembly of steel. Erection drawings illustrate how the connections will be
fabricated in the field.
8.2 CONSTRUCTION OVERVIEW:
Before the PEB Components arrives, the site and foundation should be
prepared. This includes leveling the terrain and constructing the foundation.
A. Remove trees, debris, and other items from the building
location.
B. Smooth and level the ground where the foundation is to
be made.
103
C. Construct the foundation using the materials recommended as per design
parameters.
Transiting on all corners the foundation locations are determined and trenches are
made for foundation. In foundation trenches the Anchor bolts are set along with the
concrete.
Anchor Bolt Setting:
It is extremely important that anchor bolts be placed accurately in accordance
with the anchor bolt setting plan. All anchor bolts should be held in place with a
template or similar means, so that they will remain plumb and in the correct location
during placing of the concrete. Check the concrete forms and anchor bolt locations prior
to the pouring of the concrete. A final check should be made after the completion of the
concrete work and prior to the steel erection. This will allow any necessary corrections
to be made before the costly erection labor and equipment arrives.
Unloading and Preparing Parts assembly:
The vehicle transporting your building parts must gain access to the building
site from the adjacent highway or road. Such access should be studied and prepared
in advance of arrival. When the truck arrives with the building, unload the truck
promptly, stack the steel parts evenly on blocks and protect them from the weather.
Unloading and placing the steel parts of the building in the most convenient places
for assembly will make the process easier and faster.
Blocking under the columns and rafters protects the splice plates and the slab
from damage during the unloading process. Extra care should always be exercised in
the unloading operation to prevent injuries from handling the steel and to prevent
damage to materials.
104
Location of Building Parts:
All the parts are placed around the foundation so that they will be in the most
convenient locations for installation. Bolts and nuts are placed where they will be
accessible to the parts. Purlins and girts, depending on the number of bundles, are
usually stored near the sidewalls clear of other packages or parts. Sheet packages are
usually located along one or both sidewalls off the ground and sloping to one end to
encourage drainage in case of rain. Accessories are usually unloaded on a corner of
the slab or off the slab near one end of the building to keep them as much out of the
way as possible from the active area during steel erection.
The major components comprise of rigid frame, columns and rafter, eave
struts, purlins, girts, flange braces, end-wall columns and bracing systems which
may be cables, rods angles or portals. All materials for the first bay erection are
prepared. The rafter sections required are identified by part number, and then
assembled as near as possible to their lifting positions. Then the first four columns
are erected at the braced bay, meanwhile the part number, Orientation and position
over anchor bolts were verified. Next step is to position the crane for lifting the
assembled rafter sections.
Raising Rigid Frames:
The intermediate or interior frames nearest the bearing end wall are usually
erected first. This bay usually contains the diagonal bracing. The proper completion
and plumbing of this first bay is extremely important to the successful completion of
the building. Although several methods are used to erect rigid frames, it has been
found most satisfactory to erect the columns first, tie them together with the girts and
tighten the anchor bolts. On small spans and short eave heights, columns can often
be set in place by hand without the use of hoisting equipment. Temporary bracing
should always be installed as soon as sections are lifted in place.
Completing and Plumbing the First Bay:
After the first intermediate or interior frames have been set, all purlins, girts,
and eave struts be installed in the braced bay and the entire bay plumbed, aligned
and braced before proceeding further. If the building is designed without cable
bracing, the erector is responsible for providing temporary erection bracing. When
105
this bay is properly and accurately plumbed and braced, the remaining members, to a
large degree, will automatically plumb and align when installed. After the columns
have been erected, the ground-assembled rafter is hoisted into place and connected
to the columns. The size of the rafter that can be safely handled depends on the
equipment available and the experience of the erection foreman. Generally as many
connections as possible are made on the ground.
The flange brace should be bolted to the rafter prior to raising in order to save time.
The hoisting equipment should never be released from the rafter until the frame is
adequately braced, so it cannot buckle or tip in the longitudinal direction of the
building. The same general procedures of erection apply to either clear span or
multiple span frames.
Two words of caution concerning the erection of rigid frames are in order.
The first is that rigid frames, especially free ends or cantilevered sections should
never be left “for the day” in an unsupported, un braced or unguyed condition. Such
practice has resulted in the total loss of considerable amounts of erected steel
because of wind. The second word of caution pertains to the additional care required
in the erection of multiple span frames compared to clear span frames. Frames with
interior columns, because of closer supports, have much lighter sections. They are
much more apt to buckle during erection than clear span frames, and consequently
require greater care in rigging and handling.
Erecting column Beam end walls:
Column and beam end walls of 50 feet or less in span may be raised into
position and set on the anchor bolts as a unit. All rafters, column, girts (except
outside endwall girts which connect to the sidewall girts), door headers, door jambs,
clips, diagonal brace rods, etc. should be assembled on the ground with the bolts left
finger tight. A spreader bar should be used to raise the endwall frame. Because of the
flexibility of the column and beam frames, care must be taken in locating the points
of attachment of the cables, and in raising the frame, to avoid bending about the
minor axis.
For spans of 60 feet and greater, the columns are usually erected first and
then capped with the end wall rafter. Girts, headers, jambs and diagonal brace rods
are then added between the end columns. During this erection process, the frame
must be properly braced or guyed before the lifting lines are disengaged. Final bolt
tightening should be done once the frame is plumb and square.
106
Erecting the remaining frames:
The remaining frames are erected in like manner, initially with only a few
purlins being installed in each bay, as shown below, working from one end of the
building to the other. To lend overall rigidity to the structure, install flange braces to
the purlins at specified locations. All purlin, girt and eave strut connection bolts are
left loose so that the entire skeleton framework can be plumbed without undue
difficulty. The remaining purlins can be positioned on the rafter in each bay to
facilitate the completion of the roof framing.
Installation of Bracing:
Diagonal bracing in metal buildings is critical. They provide support for wind
loads or other longitudinal loads, such as those created by an overhead crane in the
completed structure. Many times additional temporary bracing is needed to stabilize
the structure during erection. On some smaller buildings, diagonal bracing is not
needed for the building design, so the erector must furnish any erection bracing
needed.
Assemble the next brace cable the same way and connect to the next column
to form an “X” with the other cable. To square the building, measure the length of
the diagonal cables and tighten or loosen the turnbuckle/eye-bolt until the cable
lengths are the same. Brace each sidewall frame the same way so that you have an x-
brace on each side. Tighten the column anchor nuts after insuring that the building is
square.
The diagonal bracing is cable. It should always be installed as shown on the erection
drawing and should be tensioned so that the building will not sway or rock when the
wind blows. Care should be taken, however, not to over tighten and bend the
structural members. The workman should watch the structural members carefully as
he tightens the bracing. Occasionally the bracing in the wall of a building cannot be
installed in the specified bay because of doors or other complications. Usually these
can be moved to other bays without affecting the structural integrity of the building.
107
Bolting Procedure in steel structures:
This procedure applies to the permanent fixing of steel structures including
the erection of steel. Construction drawings shall indicate the grade and diameter of
all bolts, nuts and washers required for the construction. Drawings shall indicate
whether a “Friction-Type” or “Bearing-
Type” connection is required. The nominal size of the bolt holes (other than
holes in a base plate) shall be 2mm larger than the nominal bolt diameter for a bolt
not greater than 24mm in diameter and not more than 3mm larger for bolts of
diameter more than 24 mm.
Alignment and assembly
The parts to be joined shall line up in such a way that a drift of equal
diameter to the bolt can pass through the bolt holes. Drifting to align the bolt holes
shall be done is such a 3 way as not to bend or damage the parts nor enlarge the
holes. Packing shall be provided as required to ensure parts have full contact over the
mating surfaces. Prior to inserting the bolts the nut should be run up the threads to
ensure there are no thread defects that would impede the tightening process. Bolts
shall be inserted through the holes after alignment from such a direction that the nut
has easiest access for tightening.
Bolt Tightening (Snug Tightening)
Bolt Tightening is required for all Bearing-Type Connections and as a pre-
requisite to FrictionType connections. The sequence of tightening the bolts shall
proceed from the stiffest part of the connection towards the free edges. High strength
bolts that are to be tensioned may be tightened during erection to facilitate assembly
but they shall not be finally tensioned until all bolts have been snug tightened in the
correct sequence. Bolt tightening is also known as snug-tightening. Bolt or snug
tightening is achieved either by subjecting the nut to a few impacts of an impact
wrench after standard effort tightening with a podger spanner or by the full effort of
a person using a standard podger spanner. The sequence of tightening is to firstly
tighten all nuts with a standard effort and then to snug tighten using a full effort or an
impact wrench.
Wall Insulation
Fiberglass blanket insulation is the most common type used, and these
instructions pertain to this type only. One side of the blanket insulation should have a
108
vapor barrier that must face the inside of the building regardless of whether the
insulation is for heating or cooling.
Cut the insulation to length allowing an additional 6” or more to facilitate
handling. The wall panel can be used as a guide. The first run of wall insulation
should be installed so that its forward edge is just ahead of the leading edge of the
wall panel. This keeps the forward edge of the insulation ahead of the wall panel for
joining the next blanket.
Roof Insulation:
Pre cut roof insulation to reach from eave to eave allowing approximately 2
feet of additional length to facilitate handling. Hold insulation at one sidewall and
roll out insulation across the purlins, vapor barrier to the inside of the building.
Stretch the insulation to provide a tight and smooth inside surface. Double sided tape
or contact adhesives can be used to hold insulation in place while the roof sheets are
being installed. Trim excess insulation to the edge of the eave trim and cut fiberglass
approximately 4 inches from end leaving only facing. Fold facing over end of
blanket insulation to seal the end.
109
Installation of wall Panels:
Adjoining panels are installed with the overlapping rib toward the last
erected panel. Position panel to structural making sure that it is kept plumb and
install fasteners at lapped rib. Check for proper coverage and correct as necessary.
Install remaining fasteners.
Fastener Installation:
Correct fastener installation is one of the most critical steps when installing
roof panels. Drive the fastener in until it is tight and the washer is firmly seated. Do
not overdrive fasteners: A slight extrusion of neoprene around the washer is a good
visual tightness check.
Always use the proper tool to install fasteners. A fastener driver (screw gun)
with and rpm of 1700-2500 is used for self-drilling screws.
After installing the first run of insulation, prepare the eave for the first roof
panel by applying tape sealant along the eave outside of the insulation and leaving
release paper in place. Sealant must be applied in a straight line and without voids.
Splice a full closure to the starting closure and apply along the top of the eave
sealant. If roof is subject to ice and snow build-up, the splice in the closure strip
must be caulked to insure weather tightness.
Once the eave is prepared, the first roof panel may be installed. The roof
panel is set in place over the inside closure (after removing the paper from the
mastic) ensuring the major ribs of the panel nest properly with the inside closure.
Align the center of the major rib of the panel edge with the edge of the endwall
roofline. With the panel properly placed, secure the panel to the structure with
appropriate fasteners.
110
Roof Sheeting Sequence:
Final Installation
While back lapping the last roof panel (to match panel coverage with the
building length) is routinely done, this installation method can compromise the
integrity of the roof by trapping moisture between the panels. This moisture could, in
time, create an environment conducive to rust and metal failure. Manufacturer
recommends field cutting the final panel lengthwise to create the desired panel width
necessary to finish off the building. The cut edge of the panel should always be
installed on the outside edge, not the lap edge. The “narrow” panel should be
handled with care, and foot traffic avoided until the final panel is completely
installed.
Skylight Installation:
Skylight panels are installed using the same procedures as a steel panel. Care
should be taken when installing fasteners in the skylights to avoid cracking the
material. Install roof panels, leaving the light-transmitting panel run open, except for
lower light transmitting panel run panel.
Install tape sealer to panel side laps and across panel width as normal. Lay
light transmitting panel in place overlapping lower metal panel 12”. Apply double
run of tape sealer across light transmitting panel width at lower and middle purlins.
Tape sealer should align with beginning and ending edge of top flange of purlin.
111
Figure 8.4: Rigid frame columns are laid in position for raising
112
CHAPTER 9
Strength Building:
With the country's five year plan catering for infrastructure addition in the
form of airports, metros and bridges sector differentiation is expected to separate
industrial buildings and building systems. These include Design & Engineering,
Manufacture and Construction & Erection. This pattern of restructuring indicates an
industry that sees PEBs coming into its own with experiencing exponential growth
with diversification into various sectors and segments.
113
Preferred Alternative:
PEB has boon to Multi storey Buildings in India. Decking sheets with
concrete over can be used as roofing and raised to any extent above 40 meters.
These have a tracking rate of 80% in western countries.
Almost 100% of PEBs world-wide are insulated for the following reasons.
114
• Minimize energy loss, cooling load and operating cost for air conditioned buildings
• Provide acoustic insulation
• Prevent unwanted moisture condensation
Cellular beams can achieve the same strength as solid I beams of the same
depth with significantly less steel use resulting in Lighter weight. These beams offer
designers a number of opportunities for sizes and sections including varying the
depth of the beam and creating tapered sections.
Standard Seam roofina which is particularly used for sheeting. Sheets are
not punched and rolled to one above the other in order to protect leakage of water
during rains.
115
CHAPTER 10
CONCLUSION
Steel is such a versatile material that every object we see in our daily life
has used steel directly or indirectly. There is no viable substitute to steel in
construction activities. Steel remains and will continue to remain logical and wide
choice for construction purpose, environmentally also, as much of the steel used is
recycled.
Steel building offers more design and architectural flexibility for unique or
conventional styling. Its strength and large clear spans mean the design is not
constrained by the need for intermediate support walls. As your requirements
changes over the years, you can re-use, relocate, & modify the structure.
116
REFERENCES:
Journal Articles
An explanatory handbook on proposed [IS 875 part3] Wind Loads on Buildings and
structures by Department of Civil Engineering IIT Roorkee.
IS: 875 (Part 1) - 1987:- Code of Practice for Design Loads (Other Than Earthquake) for
Buildings and Structures- Dead Loads.
IS: 875 (Part 2) - 1987:- Code of Practice for Design Loads (Other Than Earthquake) for
Buildings and Structures- Live Loads.
IS: 875 (Part 3) - 1987:- Code of Practice for Design Loads (Other Than Earthquake) for
Buildings And Structures- Wind Loads.
John A. Rolphes (2006), “Industrial Building Design - Seismic Issues”, the Iron and Steel
Technology, pp. 282-298.
Books
Design Concept of Pre Engineered Building by Syed Firoz, Sarath Chandra kumar, S.
kanakambarao International Journal of Engineering Research and Applications, [vol2
pp 267272].
117
Figure A1: Frame of an Industrial shed with 25.5 meters span and 6 meters height.
118
Figure A3: Bending moment Diagrams x,y,z
119
Figure A4: Diagram of torsion
120
Figure A6: For the Frame, Shear in X,Y direction
121
Figure A8: Effect of Wind load on Windward and Leeward in 0, 90 degrees.
122
Figure A9: Beam stress
123
124