RCC CHECKLIST

PROJECT/FACILITY NAME:

CONTRACTOR: DATE: TIME:

DOCUMENT NUMBER: AFS/QMS/C/08/00 REVISION NO.:


REF. DRAWING/SPECIFICATION: GRID/LOCATION:

ITEM CHECKLIST YES NO NA


A Before start of work Check and Verify the following:
A-1 Reinforcement / Stark Steel
1 Availability of test reports of steel and reviewed
2 Bar Bending Schedule (BBS) is prepared, reviewed and approved.
3 Reinforcement / Stark steel placed as per approved structural drawing
A-2 Shuttering
1 Shuttering scheme drawing is available
2 All the shuttering materials , components available and in good condition
A-3 Concrete
1 Concrete Grade mix design is approved , Grade M-____
2 Raw material Test reports are available and reviewed
B During work process Check and Verify the following:
B-1 Reinforcement / Stark Steel
1 Cover of the specified size of cover is being fixed properly
2 Is Tying of reinforcement / stark steel done properly?
B-2 Shuttering
1 Check line , level , Size and verticality of the structure
2 Application of shuttering oil to the shuttering boards.
3 Does the shuttering have any holes or gaps and if so, are the holes or gaps
plugged ?
4 The rigidity of the Supporting system to avoid any failure.
B-3 Concreting
1 Sampling of the concrete taken at site ( 150 mm cubes) as per ITP
2 Workability ( slump) of the concrete as per the requirement
3 Are the Needle’s / Vibrators (25,40,60 mm) , available ,and are the spares
available ?
4 Batch sheet of the RMC is available and is verified as per the required grade.
C Final Inspection Check and Verify the following:
Reinforcement / Stark Steel
1 The loose concrete on the reinforcement is cleaned properly by the wire brush
2 Are there any defects Honeycombing, bulging , pin holes etc.
3 Check and Verify for any edges/corners of structure damaged during de-
shuttering.
4 Are the dimensions of the casted structure as per the drawing?
5 Is the Curing period of minimum 7 days from the casting date completed and
the records maintained?
Observations:
Whether the above points checked and in order? YES / NO

Corrective Action Proposed and Enclosures

Checked by: Contractor Witnessed by: PMC Reviewed


by: AFS

Sign:

Issue Date: 01/05/2022 Page 1 of 1