You are on page 1of 2

BUD-40/2

PV DC Surge
Protection Device
Application
PV DC BUD-40/2 Surge Protection Device was designed and
manufactured ,complying the PV standard EN50539-11, It widely used in PV DC
combiner box, inverter, controller and PV DC cabinet. Rated voltage 600V DC,
Maximum discharge current 40KA,High Energy Varistor, high effective for lightning
protection.

Appearance Introduction

1 Brand
2 Type
3 Max. Discharge Current I max
1 7
4 Nominal Discharge Current I n 2
5 Voltage Protection Level U p 3
6 Max. Continuous Operating Voltage U cpv 4
7 Indicator 5 8
8 Standard Code 6 9
9 Certificate Symbol

DC Surge Protection Device


Type Instruction

BUD - 40 / 2 600V RC

Product Max. discharge Rated With


Pole Voltage Remote
code current signalling contact

PV DC Surge RC: With Remote


Protection 40KA 2P 600V signalling contact
Device Non: Without contact

Parameter
PV DC BUD-40/3 Surge Protection Device
Suitable For Use in All Photovoltaic Pole 2P
Systems Standard EN 50539-11
Prewired Modular Complete Unit, Electrical Characteristics
Consisting of A Base Part and Plug-in Category IEC/EN IEC II/EN2
Open Voltage Uoc Max 600V DC
Protection Modules
Max Continuous Operational Voltage Uc 600V DC
Plug-in Protection Module, Easily
Nominal Discharge Current In(8/20)μs 20KA
Installation and Maintainance
Maximum Discharge Current Imax(8/20)μs 40KA
High Energy Varistor, Response Time
Voltage Protection Level Up Up ≤3.8KV
Less Than 25 Nanosecond
Response Time ≤25ns
Optional Remote Signalling
Contol and Indication
Contact(FM) for Monitoring Device
Operating State/fault Indication Green/Red
(Floating Changeover Contact)
Plug-in Protection Module
Din Rail Mounting TH35-7.5/DIN35
Remote Signalling Max. Working Voltage(V) 30V DC
Comply with :EN 50539-11 Contact (Optional) Max. Working Current 1A
Connection And Installation
Hard cable mm2 4~25
Wire
Flexible cable mm 2 4~16
Terminal Screws M5
Main Circuit 2.5
Torque(Nm)
Remote Contact 0.25
Degree of Protection IP20
Installation Environment
Operating Temperature Range (TU) -40℃~+80℃
For Mounting on TH35-7.5/DIN35
Relative Humidity 30%~90%
Weight kg 0.24

01
BUD-40/2
PV DC Surge
Protection Device
Principal Drawing

BUD-40/2 BUD-40/2 Converter


F
L+ AC
Generator

F
L- DC

Wiring Method

L+
L-

Dimensions(mm)
46.5

84
89
35

5.5 44
36
69.5

02