ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 1/ 43
BERLIN Date: Nov. 8, 02
GeN2
Trouble Shooting Guide
Document Revision :
CONTENTS
INTRODUCTION
The trouble shooting guide helps to analyze the failure when disturbances are occurring and
describe the way how to proceed to repair the failure. The guide includes several parts con-
cerning the different sub-components being part of the GeN2 system.
The different parts of the trouble shooting guide are listed below.
Part Title
9 Glossary
In case of failures which are not handled in this document and if the trouble is not located, then:
Fill out the event logging report for: TCBC and/or MCBIII and/or SPBC and/or DCSS5
Note all remarks concerning the disturbance
Send the report back for root cause analysis
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 5/ 43
BERLIN Date: Nov. 8, 02
Status Observation
elevator is running with failure _________________________________________________
elevator is blocked _________________________________________________
1) Floor: _________________________________________________
a) Hoistway and car door opened _________________________________________________
b) Hoistway door closed _________________________________________________
2) Between the floors and _________________________________________________
The list given below shows the possible failures related to the GeN2 electrical system. The
failures are classified according to the corresponding root cause.
Defective parts:
PCB, speed encoder, EPROM, EEPROM DEF
Switch, Sensor
Wrong wiring WIR
SPBC
SERVICE PANEL BOARD with CAN
SPBC
SERVICE PANEL BOARD with CAN
SPBC
SERVICE PANEL BOARD with CAN
SPBC
SERVICE PANEL BOARD with CAN
7 6
6 5 Battery failure BAT
5
4 4 E2PROM failure DEF
3
2
3 Measured direction does not match dictated direction MEA
1 2 Encoder B failure DEF
0
1 Encoder A failure DEF
0 Task timing error MEA
SDI blinking in both directions while stopping. TEST shows event ‘01’
Possible reason What to do
check rescue encoder wiring WIR
no signals from encoder-track A
replace rescue encoder DEF
Learn Run
Possible reason What to do
The drive package is performing its wait until the learn run is completed.
Learn Run
The drive package is adjusting the
encoder.
DoorBridge DW or DFC input has not been low while the door was opened.
Possible reason What to do
bridged door lock. check safety chain
This event is stored into EEPROM so that the ONLY SIG
way to bring the elevator into operation again is by using
INS.
TCI-lock
Possible reason What to do
The sequence to leave TCI-mode was Correct steps are:
not correctly followed 1. open door
OPE
2. switch TCI off
3. close door
1LS+2LS on
Possible reason What to do
Limit switches 1LS and 2LS are active Check power supply of the position reference system.
POW
at the same time.
Adr-Check
Possible reason What to do
Some RSL I/Os have to be pro- Set I/O 691 to a valid address
grammed to a valid address and are
not allowed to be set to 00-0 or 01-0. SIG
Currently only one I/O is checked:
691 – TCI
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 16/ 43
BERLIN Date: Nov. 8, 02
SE-Fault
Possible reason What to do
The car cannot start due to missing Check the door bypass
SIG
SE-signal
1TH-Fault
Possible reason What to do
The DBR-contact which is connected The drive is powered down to allow cooling.
SIG
to the input 1TH is opened.
2TH-Fault
Possible reason What to do
One of the contacts which is con- The drive is powered down to allow cooling.
SIG
nected to the 2TH is opened.
PowerSave
The drive package is currently switched off to save energy.
start DCS!
Possible reason What to do
Normal operation is not allowed until Enter M-1-3-5 to start the DCS!
the Door Check Sequence has been
completed successfully.
OPE
The DCS is required again if one of
the parameters TOP or BOTTOM is
changed.
Shutdown
Possible reason What to do
The drive reports a Shutdown See event logging of MCBIII. OPE
CAN-Communication not working check CAN-wiring
COM
check CAN-LEDs
MCLS/SKL-3
Possible reason What to do
Car Light Switch in Machine Room Switch on the car light switch/related setup: MCLS (697)
OPE
has been switched off
Car Light Relay on top of car is Check the car light relay/related setup: CLR (1000)
PAR
dropped.
LBG/CSP-2
Possible reason What to do
Light Beam Gate has been active. check related setup: LBG (967) PAR
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 17/ 43
BERLIN Date: Nov. 8, 02
SPB: HTS
Possible reason What to do
Hall Temperature Sensor from Ser- Wait until the temperature is lower than parameter SPB-
vice Panel Board is activated. Car is temperature
shutdown at next commitable floor
and taken out of service
SPB-Comm.
Possible reason What to do
CAN-Communication to SPBC is not check CAN-wiring
working. COM
check CAN-LEDs
Task Timing
software entered endless loop
W_Dog Reset
watchdog circuit on LCBII was triggered
Illegal Int
illegal interupt was executed
CanTxFull
CAN messages cannot be sent
CanBusOff
CAN communication has been restarted
MCB-Comm.
No CAN connection to the drive
SPB-Comm.
No CAN connection to the SPBC
Note: the above information (wrong software run and communication) is for engineering only
6.3 Operational control subsystem related failures
OpMode NAV
OCSS is not available due to drive fault (e.g. drive-fault (NR). This mode is also active after INS before the
COR starts
EPO shutd.
Possible reason What to do
car is not able to run during EPO; the related setup:
next car is allowed to recover NU (017)
OPE
NUSD (018)
NUSG (019)
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 18/ 43
BERLIN Date: Nov. 8, 02
OpMode DTC
Possible reason What to do
door was not able to close (missing related setup
DCL, DFC or DW) within timeout DCL (694)
RDCL (695) SIG
DOOR, REAR
DTC-T
OpMode DTO
Possible reason What to do
door was not able to open (missing related setup
DOL) within timeout DOL (000)
RDOL (544) PAR
DOOR, REAR
DTO-T
OpMode DCP
Possible reason What to do
car was not able to answer a call related setup
within timeout (e.g. door was held DCP-T PAR
open manually)
PDS active
Possible reason What to do
partition door switch is opened related setup
PAR
PDD (784)
DS bypass
Possible reason What to do
Malfunction of Disable Door Switch related setup
Relays (DDSR) for Generic Firemen DDSRC (970) PAR
Service.
EEC bypass
Possible reason What to do
Malfunction of Disable Emergency related setup
Exit Contact Relay (DEMERC) for DEMERC (971) PAR
Generic Firemen Service.
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 19/ 43
BERLIN Date: Nov. 8, 02
/DZ in NST DZ-signal was lost or not detected at all after having stopped
Possible reason What to do
The inputs signals 1LV, 2LV on Check the input signals on MCBIII
SIG
MCBIII are missing
CAN-Communication not working check CAN-wiring
COM
check CAN-LEDs
DrvShutdown
Possible reason What to do
The drive reports a Shutdown See event logging of MCBIII. OPE
CAN-Communication not working check CAN-wiring
COM
check CAN-LEDs
1TH-Fault
Possible reason What to do
The DBR-contact which is connected The drive is powered down to allow cooling.
SIG
to the input 1TH is opened.
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 20/ 43
BERLIN Date: Nov. 8, 02
2TH-Fault
Possible reason What to do
One of the contacts which is con- The drive is powered down to allow cooling.
SIG
nected to the 2TH is opened.
PowerSave
Possible reason What to do
The drive package has been powered related setup: PDR-D
PAR
on
DBP: dfc_SE
Possible reason What to do
While the door was opening or fully related setup:
opened, the door bypass was found to EN-RLV, PAR
be inactive (DFC low or SE high) EN-ADO
DCL in [ ]
Possible reason What to do
(R)DCL was active while the door was related setup
fully opened DCL (694) PAR
RDCL (695
DoorBridge DW or DFC was not low during the last door cycle
Possible reason What to do
the safety chain is bridged remove the bridge SAF
the Door Bypass is defect check the door bypass DEF
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 21/ 43
BERLIN Date: Nov. 8, 02
DOL:alw. on
Possible reason What to do
(R)DOL was active while the door was related setup
fully closed. This event is also logged DOL (000)
when the fuses of the door system are RDOL (544)
PAR
burned.
This event is not logged within the first
40 seconds after system startup.
Hwy Access
Possible reason What to do
Landing Door was opened. see description for blinking message 'Switch INS' OPE
RSL parity Two remote stations with the same address are connected to the same link
Possible reason What to do
Wrong connection Check the RS connections WIR
RNG1 msg
data error on Duplex/Triplex ring
RNG1 time
no ring messages received from other car for a specific time
RNG1 sio
framing error on Duplex/Triplex ring
RNG1 tx
ring messages couldn't be sent in an appropriate time
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 22/ 43
BERLIN Date: Nov. 8, 02
The Service Panel Board detected a malfunction which hinders a manual rescue
SPB-Alert
operation with SPBC and SDI.
Possible reason What to do
defective speed encoders for SDI Press the SPBC-buttons REB + DDO simultaneously to DEF
defective E2PROM on SPBC locate the error. DEF
Missing battery for SPBC BAT
SPB:TempHTS
Possible reason What to do
The Service Panel Board detected an related setup
PAR
over temperature. SPB-Temp
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 23/ 43
BERLIN Date: Nov. 8, 02
SYS : Shut down A run was interrupted because of a shut down error.
Possible reason What to do
the error which caused the shut down Message allows a quick overview over the last shut
is displayed with <shift> <down> downs, for further information refer to the concerned OPE
event.
SYS : E2P Default All parameters are set to their default values.
Possible reason What to do
The unit is not able to run with default If the parameters were stored by SVT (M-3-7) the setup
values. can be reload by SVT (M-3-8). Otherwise the unit has to PAR
be readjusted again.
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 24/ 43
BERLIN Date: Nov. 8, 02
SYS : E2P InvPara Any parameters stored in the EEPROM are outside the range of their minimal or max-
imal values.
Possible reason What to do
error occurs when the EEPROM is re- Note all parameters, set DEFAULT parameters, readjust
PAR
moved and replaced with new one the parameters again.
EEPROM self test (M-2-3) failed Change EEPROM. DEF
Sub-code for further information: Press <Down> or <Shift-3>
p number of parameter which is out of range (EEPROM(p): information for Engineering only
SYS : Power fail The line voltage was outside its specified range for a short time (e.g. one phase is lost).
Possible reason What to do
voltage loss (line) check line connections L1 to L3 POW
short voltage drop or voltage variation verification of line voltages with recorder necessary POW
SYS : Inv-Relay Inverter relay dropped, will logged at switch off of the inverter each time
Possible reason What to do
Power save mode is active: The error information only
is logged every time when the inverter
OPE
is switched off by removing HL1 or
110V.
The drive blocks if one inverter or refer to error 1 ”SYS: Shut Down”
safety error occurs several times in OPE
series.
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 25/ 43
BERLIN Date: Nov. 8, 02
SYS : not all err Not all events have been stored during last power-OFF
Possible reason What to do
Too much errors have been logged Notify all saved error events and clear error logging.
before power has been switched off. MEA
Some events and/or maintenance in-
formation may be lost.
INV : > Heat Packg IGBT heat sink temperature exceeded, fault message occurs 10°C before shut down
(err. = 80°C, fatal e. = 90°C).
Possible reason What to do
test fan: M-2-7
- The fan should run with fast speed for one minute
defective fan DEF
after activating this test.
change the fan if necessary
dusty / clogged air filters clean / exchange air filters DEF
defective temperature sensor change inverter DEF
INV : > Curr Motor Motor current exceeds 240% of the inverter current.
Possible reason What to do
power of inverter is too low check inverter power: reduction of acceleration rate may
PAR
help (<M> <3> <2> <GOON> ACC)
short circuit in the motor or earth leak- check motor and motor cable
WIR
age
faulty encoder signals check encoder, encoder cable WIR
INV : Temp meas Temperature measurement at the heat sink does not work correctly
Possible reason What to do
ambient temperature is very low Check monitored IGBT heat sink temperature: M-2-1
MEA
(< 5°C) verify temperature in machine room
defective Temp. sensor (error occurs change inverter, danger of overheating for MCBIII or in-
DEF
permanently) verter
INV : brake chopp Brake IGBT has a short circuit or is not connected
Possible reason What to do
DBR not properly connected check connection of DBR WIR
defective Brake IGBT change Inverter DEF
MC: FR w/o Learn Normal run is not possible without previous successfully learn run.
Possible reason What to do
learn run not performed learn run has to be performed OPE
MC: MC + Safety Ch Motion Command of TCBC does not fit to feedback UIB, DIB
Possible reason What to do
faulty wiring correct wiring WIR
defective MCBIII input change MCBIII DEF
The input signal change was to fast at ignore MEA
inspection mode
Inspection runs are allowed w/o TCBC support, normal runs are prohibited. Fatal error
MC: OCSS disabld
because UIB/DIB signals available but no commands from TCBC for normal run
Possible reason What to do
Parameter 'MCB operate' is set to 1 set parameter 'MCB operate' (M-3-1-goon) to 0 PAR
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 28/ 43
BERLIN Date: Nov. 8, 02
MC: Chk SW Sig incorrect state of SW signal, SW-signal indicates switching state of main contacts
Possible reason What to do
faulty SW contactor check inputs SW SIG
faulty wiring check wiring WIR
defective MCBIII change MCBIII DEF
MC: Chk DBD Sig incorrect state of DBD signal (1 = Stop , 0 = run)
Possible reason What to do
faulty SW1, BR or BY check inputs, SW, BR or BY SIG
faulty wiring check wiring WIR
defective MCBIII change MCBIII DEF
Load weighing calibration not performed at start of a run. Run is started with
ALW:No LoadW Cal
pre-torque for balanced load.
Possible reason What to do
LW calibration not performed perform load weighing calibration OPE
MLS : < ACC Dist The car did not reach the nominal speed.
Possible reason What to do
secondary effect of Emergency Stop, check other occurred errors
OPE
Shut Downs, Correction runs
MLS : < Dec Dist The distance for the deceleration is too short. The car stops without creep speed.
Possible reason What to do
secondary effect of Emergency Stop, check other occurred errors
OPE
Shut Downs, Correction runs
it is possible that the MCBIII has check other occurred errors
MEA
miscount
The actual floor distance does not start learn run again
correspond to the learned floor OPE
distance.
Parameter 'T_creep' too small increase parameter 'T_creep' (M-3-3- goon) PAR
MLS : TCB Inp Error TCBC command GOTO floor: Target < Bottom floor or Target > TOP floor
Possible reason What to do
parameter mismatch check TOP FLOOR, BOTTOM FLOOR on MCB_III and
PAR
TCBC
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 30/ 43
BERLIN Date: Nov. 8, 02
MLS : 1LS Ini Dec Deceleration in the bottom landing initiated by 1LS.
Possible reason What to do
correction run ignore
Parameter '1LS DLY' is too small. Increase parameter '1LS DLY' (M-3-3-goon). After that
the deceleration distance for a correction run is to be
PAR
checked, if it is still sufficient. A correction run is released
after an inspection run.
MLS : 2LS Ini Dec Deceleration in the top landing initiated by 2LS.
Possible reason What to do
correction run ignore
Parameter '2LS DLY' is too small. Increase parameter '2LS DLY' (M-3-3- goon). After
that the deceleration distance for a correction run is to be
PAR
checked, if it is still sufficient. A correction run is released
after an inspection run.
UIS or DIS missed passing a door zone. The message is generated in the moment
MLS:UIS/DIS miss
when the relevelling conditions are fulfilled. Relevelling run is not performed.
Possible reason What to do
missing UIS or DIS sensor or wiring check sensors and wiring SIG
LV signal was not detected during creeping, although the creep time reached 67% of
MLS : LV Missed
DDP time. The message is displayed when the error is occurring eight times
Possible reason What to do
secondary effect of Emergency Stop, check other occurred errors
OPE
Shut Downs, Correction runs
it is possible that the MCBIII has mis- check other occurred errors MEA
count
missing LV magnet or defective sen- check magnets and sensors by an INS RUN
DEF
sors
only one LV signal was detected at check LV1, LV2 relays and LVCT time using a slow INS
SIG
units with 1LV and 2LV RUN (CREEP SPE has to be reduced too).
defective MCBIII change MCBIII DEF
Levelling zone lost, deceleration distance too short, see error 'MLS <Dec Dist'. The
MLS : LV Lost
message is displayed when the error is occurring eight times
Possible reason What to do
secondary effect of Emergency Stop, check other occurred errors
OPE
Shut Downs, Correction runs
it is possible that the MCBIII has check other occurred errors
MEA
miscount
LV DLY too large decrease LV DLY (M-3-3-goon) PAR
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 31/ 43
BERLIN Date: Nov. 8, 02
Over speed: the motor turns 10% faster than the dictated speed profile. The message
DRV : > Speed
is displayed when the error is occurring four times
Possible reason What to do
parameter is incorrect Check the parameter 'Sys Inert' (M-3-1-goon) PAR
DRV : < Speed Low speed : the motor turns 45% slower than the dictated speed profile.
Possible reason What to do
defective encoder Check encoder, use SVT-Menu ”PVT” (M-2-6). DEF
defective MCBIII Change MCBIII DEF
Inertia of the whole system is too big. Check the guide and distance between guides, check MEA
the inertia of motor and gear.
parameter is incorrect. Check the parameter 'Sys Inert' (M-3-1-goon) PAR
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 32/ 43
BERLIN Date: Nov. 8, 02
Motor current exceeds 200% of nominal current for more then 3 seconds. The
DRV : OverLd >Time
message is displayed when the error is occurring four times
Possible reason What to do
acceleration rate is too high decrease acceleration rate ”DEC” (M-3-3-goon) PAR
power of inverter is too small check power of inverter and motor OPE
fly wheel inertia is too big reduce fly wheel COM
Sub-code for further information (Press <Down> or <Shift-3>)
t = 3 3 sec general overload
The current of one motor phase is zero. The message is displayed when the error is
DRV: Phase Down
occurring four times
Possible reason What to do
the motor wiring is disconnected check motor wiring, connectors and SW contacts
WIR
(between inverter and motor)
power of inverter is too high check power of inverter and motor
OPE
(current <10%)
Sub-code for further information: Press <Down> or <Shift-3>
p=1 Phase-check failed: no current in motor phase 1
p=2 Phase-check failed: no current in motor phase 2
p=3 Phase-check failed: no current in motor phase 3
p = 10 Phase-check failed: no current in all motor phases
p = 20 invalid combination during current phase-check: current in single-phase only (possible leakage current)
Speed controller output (motor torque & current) has reached the internal limit see er-
DRV: I Overload
ror "INV: >CURR MOTOR"
Possible reason What to do
power of inverter is too low check inverter power reduction of acceleration rate may
OPE
help (<M> <3> <2> <GOON> ACC)
short circuit in the motor or earth leak- check motor and motor cable
WIR
age
faulty encoder signals check encoder, encoder cable WIR
7.8 Learn run (LRN) and encoder adjustment (ADJ) related messages
LRN : Learn abort Learn run was aborted because of an error
Possible reason What to do
Learn run was aborted see Error Logging (<M> <2> <1>) OPE
LRN : < Mag Len Length of magnet is too short (minimum 170 mm)
Possible reason What to do
faulty floor will displayed in Error use magnet with the right length
DEF
Logging
LRN : > Mag Len Length of magnet is too long (maximum 450 mm)
Possible reason What to do
faulty floor will displayed in Error use magnet with the right length
DEF
Logging
LRN : < Floor Dist Distance between 2 door zones is too short (minimum 170 mm)
Possible reason What to do
faulty floor will displayed in Error check distance
MEA
Logging
LRN : > Floor Dist The run time at contract speed between 2 landings is more then 52 seconds.
Possible reason What to do
Floor distance is too large. Check floor distance, install intermediate landing if
MEA
necessary
The positive edges of LV were not
see error 'MLS: LV trig err' MEA
read correctly.
LRN : Too many LV It will be count more floors at learn run then adjusted by SVT (Top Floor).
Possible reason What to do
parameter TOP FLOOR is incorrect Check parameter 'TOP FLOOR' (M-3-1-goon). PAR
Drive performs automatic encoder adjustment (e.g. after manual rescue operation
ADJ: Auto-Encadj
(MRO) during power-OFF)
For information only
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 35/ 43
BERLIN Date: Nov. 8, 02
Motor current was for 10 sec higher than setup limit. If this event occurs 3 times within
Motor Protect
120 sec, the DCSS switches to lock mode.
Possible reason What to do
Wrong motor selected Check the parameter setup for motor type: 3-2-5 PAR
Check the motor windings (about 60 … 70 /winding for
Motor is defect DEF
a motor with 100 W)
Reduced pulses from encoder are measured. DCSS switches into INI mode.
This error does not mean, that the error comes from the encoder itself. Please
Encoder Err
follow the steps explained below. If the door does not work correctly then re-
place the encoder
Possible reason What to do
The door mechanic is shortly When occurring many times:
blocked, e. g. disturbance caused by Start open/close door command and check the position OPE
a passenger Monitor the door status: 3-1-1 (Position: …. mm)
When occurring occasionally:
Start the continuous run: 3-4-2 and check the position OPE
Monitor the door status: 3-1-1 (Position: …. mm)
Encoder wiring or connection Check the wiring and the connection WIR
Bad fixation of the encoder Check the fixation OPE
One or two tracks of the encoder are Replace the encoder
DEF
damaged
Indicates that the check sequence for the discrete interface failed three times. DCSS
3wireComFail
is set into locked mode
Possible reason What to do
the communication failed Start the check sequence : 3-2-4 COM
DCSS out of order, serious event occurred. DCSS is de-energized and does not react
System Locked
on commands
Possible reason What to do
Motor Protect event, or Unlock DCSS performimg power down – power up se-
InverterProt event, or quence or SVTOOL key-sequence ‘shift 5’ OPE
(see the above given detailed information)
3wireComFail event
A problem could occur if the memory is full during a maintenance cycle. After each
Logging Full
maintenance cycle time the event logging is to be deleted.
Possible reason What to do
Event logging memory full delete logging to free memory MEA
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 36/ 43
BERLIN Date: Nov. 8, 02
9 GLOSSARY
1LS = Normal Terminal Slowdown Limit Switch for the bottom floor
1LV = Door zone recognition for down run
1TH = Thermal contact 1
2LS = Normal Terminal Slowdown Limit Switch for the top floor
2LV = Door zone recognition for up run
2TH = Thermal contact 2
ACC = Acceleration
ADC = Analog to Digital converter
ADJ = Adjustment
ALB = Alarm button
ATT = ATTendend service
BAT = Battery
BOT FL = Bottom floor
BRA = Brake
BRB = Brake release button
BS = Brake switch
BS1 = Brake switch 1
BS2 = Brake switch 2
BY = BY-Relay
CAL = Calibration
CAN = Controller Area Network
CB = Car button
CCBL = Car Call to Bottom Landing
CCTL = Car Call to Top Landing
CDL = Car Link
CHC = Cancel hall calls
CHCS = Cancel hall call switch
CHK = Check
CLR = Car Light Relay
COM = Communication
CON SPE = Contract speed
CRE SPE = Creep speed
CRP = Creep
CSP-2 = Car sill protection (light beam gate)
DBD = Drive brake disconect
DBP = Door bypass
DCL = Door close limit signal
DCP = Delayed car protection
DCS = Door check sequence
DCSS5 = Door Control Subsystem 5
DDO = Disable door operation
DDP = Delayed drive protection (run timer)
DDSR = Disable door switch relay
DEC = Deceleration
DEF = Defective
DEMERC = Disable Emergency Exit Contact Relay
DFC = Door fully closed contact
DIR = direction
DIS = Indicator for start/stop relevelling up
DIST = Distance
DLY = Delay
DOB = Door open button
DOL = Door open limit
DRV = Drive
DS = Door switch
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 37/ 43
BERLIN Date: Nov. 8, 02
PAR = Parameter
PCB = Printed Circuit Board
PDB = Power drive board
PDD = Partition door device
PDS = Partition door switch
PES = Pit emergency stop switch
POW = Power
PROF = Profile
PROT = Protection
PRS = Position Reference System
PSI = Power supply interface
RDY = ready
REB = Remote enabling button
REL SPE = Relevelling speed
REM = Remote Elevator Monitoring
RMP DWN = Ramp down
RRB = Remote resetting button
RS = Remote Station
RSL = Remote Serial link
RTB = Remote tripping button
SAF = safety
SDI = Speed direction indicator
SIG = signal
SKL = Car light disconnecting switch
SPBC = Service panel board with Can
SPE = Speed
SR = Slow run
SVT = Service tool
SW = Switch
SYS = System
TCBC = Traction Control Board
TCI = Top of car inspection
TES = Top of car emergency stop switch
THB = Thermo contact
TOC = Top of car
TOCI = Top of car inspection
TOP FL = Top floor
UDLS = Up Down final Limit Switch
UIS = Indicator for start/stop relevelling down
VDC = Voltage DC
WIR = Wiring
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 39/ 43
BERLIN Date: Nov. 8, 02
TCBC
Date: ______________
Software version and release date
Version: G_____________
MCBIII
Date: ______________
Software version and release date
Version: G_____________
SPBC
Date: ______________
Software version and release date
Version: G_____________
DCSS5
Date: ______________
Software version and release date
Version: G_____________
OTIS FIELD COMPONENT MANUAL
Part:
No.: GAA21000CJ_TS1
Worldwide Engineering Vintage: 01 / 1
ENGINEERING CENTER Trouble shooting Guide (Draft) Page: 40/ 43
BERLIN Date: Nov. 8, 02