ACD3 CONTROLLER
Testing & Commissioning
MSK Operation (Start-up)
1. Controller Installation
Install the controller, LCRD(Regen Drive), ARO & EIP according to a shop drawing.
Controller UD/LCRD* ARO E&I Panel
Model
Standard Standard Option Standard
Muse Top floor
Overhead
landing
*) ”Regen” logo is indicated at the box of LCRD & UD.
1.1. Controller
Install controller as following figures.
EIP
Fixing
bracket
[Shop drawing]
[EIP]
R – S – T, N(Neutral) & Earth (EIP to Controller)
TB2
4E
R S T N
4E of controller Hoistway
(Car fan & light) & pit light
TB1
TB2
TB2
TB1
TB1
TB7
PIN
TB7
U,V,W
Field panel
SPBC-2
AP-I/O
-.OVFR3B-401/402 UD
Field panel
DCPB
AP-I/O
-.OVFR2B-403/404 LCRD
-.OVFR2A-406 60CR
P8:2 B M
BRK_DC- P1:3 BV U
B1 BRK
power
P1:2 PE
P8:3
B
Machine
P7:2 P2 1
Machine
BS1 1/BN BS1
P2 3 4/BK
P2 2 3/BU
P7:3 BS2 BRK S/W
P2 4 1/BN BS2
P2 6 4/BK
P7:1 24V P2 5 3/BU
P7:4
Return
Machine W/ BS
Machine W/O BS
-.OVFR3B-401/402 UD + BOMCO-W
4D 1
P2:5
BRK_DC+
B
BV B M BRK
4D 3 B1
P2:6
U power
BRK_DC-
4D 2 PE
P2:9
B
BRK_PE
Machine
COM1 P2:1 7D 3
BS1 BSR*30VDC
NO1
7D 4 BS2
NC2 P2:4 7D 2
BRK S/W
COM2 P2:3
BS2
NO2
Machine Brake
4D 1 P1:1 P5:1
BS1
Machine W/O BS
BRK
Machine W/ BS
power
4D 1 P1:1
BRK_DC+ B
B M
4D 3 U
B1 BRK
P1:3 BV
power
BRK_DC-
4D 2 P1:2 PE
B
Machine
COM1 P2:1 7D 3
BS1 BSR*30VDC
NO1
7D 4 BS2
COM2 P2:3
BS2
NO2
Machine Brake
4D 1
P2:5
BRK_DC+
B
BV B M BRK
B1
4D 3
P2:6
U power
BRK_DC-
4D 2 PE
P2:9
B
BRK_PE
Machine
COM1 P2:1 7D 3
BS1 BSR*30VDC
NO1
7D 4 BS2
7D 2
BRK S/W
NC2 P2:4
COM2 P2:3
BS2
NO2
Machine Brake
4D 1
P2:5
BRK_DC+
B
BV B M BRK
B1
4D 3
P2:6
U power
BRK_DC-
4D 2 PE
P2:9
B
BRK_PE
Machine
8D 1 P2:2 NC1
BS1
BS1
8D 3 P2:1 COM1
BSR*30VDC
8D 4 P2:4 NC2
8D 2 BS2
BRK S/W
P2:3 COM2
BS2 8D 5
P2:6 NC3
BS3 8D 6
BS3
P2:5 COM3
Machine Brake
*)MRL
START CONN. Function END CONN.
(EIP) (ARO)
EA1 10P UPS_24V, ARO_ST C1 9P
EA2 4P Drive*110V, MRO*BAT+, C3 2P
EA3 9P BAT*VF, BAT*SPB C2 2P
P3A 2P
P3(BCB) 6P
EA4 10P BAT P4(BCB) 10P
*)MRL/MR
START CONN. Function END CONN.
(HIVB) (ARO)
TB9 TERM MRO+, MRO- C5 3P
*)MRL/MR
START CONN. Function END CONN.
(Field panel) (ARO)
1A 5P CAN_24V, SPB+ C4 5
2A 3P ARO*OUT TB3 TERM
3.2. Check the Motor Cable and make sure the shield layer properly connected on both
ends of the cable.
Attention: Must put the shield layer out of cable skin and use clamps to fasten
shield layer of the cable.
Attention: The cable of rotary encoder must be separated with motor 3 phases
cable and the each wire of the encoder cable must be twisted.
4. MSK connection
Adapter cable #2
(Field tool)
LSD Cable
(Factory supply)
Note) LSD cable will be
used for interphone after
MSK operation.
Procedure Location
Remove P102C, P4M, & P104C from factory GECB AP-IO
Connect P102C & P4M to LSD cable after checking
cable number (Type: Wago connector)
Connect P102C, P4M, connectors to controller GECB AP-IO
Connect P104C (jumper connector) GECB AP-IO
Connect 2H (jumper connector) Field panel
(2H)
Field panel
MSK kit
Put the jumper bridge so that Inspection (or INS) is right position as following
drawing (DW LED of GECB will be on)
[Door bypassed]
[Normal condition]
P102C #4 #5
4.3. Install safety box and connect as following table for the safety chain.
5. Start-up (MSK)
Measure 3 phases voltage & neutral at the line side of OCB after switching on
building power.
Measure 3 phases voltage & neutral at the line side of OCB after switching on OCB.
PS1
110Vac
PS2
PS3
54Vac
PS4
220Vac 27Vdc
Check the volt after removing P1H & P101C, connect back after measurement.
Type Check points Standard
Hall Link P1H:4 & HL2 27Vdc±10%
Car Link P101C:4 & HL2 27Vdc±10%
Check LED condition of SPBC board (After convert to ERO mode and switching
on OCB.
Off
On
Flickering
Note:
The battery is charged by SPBC. For full charging, at least 8 hours shoul be
charged.
In case of power failure, battery will be discharged by the command of
SPBC_III.
If the power supply is cut for long period (>6hours), disconnect the battery
temporarily.
1PES (1st Pit Emergency Switch), 2PES (1st Pit Emergency Switch),
GTC(Governor Tension Check Switch)
-. Check if the signal of car & landing door is correct by LED of SPBC.
Press
“DDO”
Service Tool
port
6. Parameter setup
6.1. Parameter of GECB & GDCB will be set by the factory. However setting values are
required to check before real operation.
M-GECB-1-3-1-7-GOON(Service)
SPB Type 255 w/o ARO
0 w/ ARO
M-GECB-1-3-1-4-GOON(Drive)
DRV-TYP 1
M-GECB-1-3-1-1-GOON(System)
TOP Top floor Start from 0
(Bottom floor = 0)
M-GECB-1-3-1-5-GOON(Doors)
Door 13 To be same each
Rear 13 other
[Parameter display]
Encoder PPR
3600> XXXXX
During LRT operation, noise will come out from the motor,
but it is normal. And it won’t be conducted in normal operation.
If error is detected (Brake drop), it will be conducted.
The system is normal but a car is not moved even with up/down signal:
7.2. After RE calibration, the car direction should be checked by pressing pendant
switch whether the direction is correct.
M 2 3 2
☞ MODULE DRIVE SETUP ADJUSTMENT
8. Test running
Controller
Adapter cable
#1
LSD Cable
Cross head
300mm or bigger
400m
m