Selection guide
SUNSYS B15
SUNSYS B20
SUNSYS B30
Field boxes
FJB ENCLOSURE
20
SUNSYS P33TR-P66TR ........................................... p.30
SUNSYS P
SUNSYS P100TR .................................................... p.32
PARK applications
SUNSYS P66TL-P100TL .......................................... p.34
SUNSYS IFB ........................................................... p.36
26
FJB ENCLOSURE .................................................... p.36
SUNSYS IFB
Sunguard ................................................................ p.46
Monitoring
Communication interfaces ...................................... p.46
Power supply, switchboard with surge protection device ....p.49
Environmental sensors ............................................ p.50
42
DIRIS Router/modem ....................................................... p.51
LCD/LED Display .................................................... p.52
DIRIS ..................................................................... p.54
SUNSYS SHELTER 56
Load-break switches, fuses, surge protection device .....p.66
Equipment
SIRCO PV
SIRCO MOT PV
64
SIRCOVER PV Service ................................................................... p.72
Service, training
Training ................................................................... p.78
70
Technical guide ....................................................... p.86
RM, PV, PV, gPV FUSES
Technology
SURGYS G51-PV, D40, PV BASES
84
General catalogue 2013 1
An independent manufacturer
the benefit of a specialist
CORPO 308 A
The culture of independence A flexible manufacturing Responsible growth
The independence of the SOCOMEC Group structure As a Group which is open to all cultures
ensures it retains control of the decision- Backed by two European centres of and firmly committed to human values,
making process, respecting the values excellence (France and Italy), the Group also SOCOMEC promotes employee initiative
advocated by its own family shareholders and benefits from competitive production sites, and commitment. Working relationships are
shared by its employees. such as in Tunisia, and locations in the major based on the idea of partnerships and respect
With around 30 subsidiaries located on all emerging markets (India and China). for shared ethics. Through the company’s
five continents, SOCOMEC has developed All sites have implemented a policy of commitment to achieving harmonious, lasting
internationally by targeting industrial and continuing development based on ’Lean development, SOCOMEC fully embraces
service applications where the quality of its management’ principles; this ensures they are its responsibilities not only towards its
expertise makes all the difference. in a position to offer the quality, lead times and shareholders, employees, customers and
cost expected by our customers. partners, but also towards society as a whole
The spirit of innovation and its environment.
The focus on service SOCOMEC has been a signatory to the Global
As undisputed specialists in UPS systems, Compact since 2003.
source supply changeover, power conversion Our manufacturing expertise naturally extends
and measurement, SOCOMEC dedicates to a complete range of services designed
nearly 10% of its turnover to R&D. This means to facilitate the research, implementation
the group devotes the resources required and operation of our solutions. Our teams
to achieve its ambition: to always be at the of engineers have built their reputation on
cutting-edge of technology. reassuring closeness, specialist expertise and
a focus on customer needs.
The vision of a specialist
As a manufacturer with complete control
over its technological processes, SOCOMEC
is quite unlike the more general providers.
The Group is constantly building on its fields
of expertise in order to offer its customers
increasingly customised, better adapted
solutions.
Power Control & Safety SOCOMEC’s expertise in this domain SOCOMEC guarantees solutions and services
is unquestionable ; the company is an which are both relevant and efficient.
Managing power and protecting
undisputed leader in power switching and
individuals and property.
changeover functions, and has been a
specialist manufacturer of electrical equipment
since 1922. The company has long defended
the benefits of fuse protection for individuals
and property, and has become a major player
in cutting-edge technology such as the
monitoring and detection of insulation defects.
Solar Power As experts in the solar energy equipment field, • control of very high-efficiency energy
SOCOMEC has all the specialist know-how conversion, via PV inverters that transform
Guaranteeing the safety and durability of
for implementing key strategic functions in PV all energy generated by the solar panels into
photovoltaic (PV) facilities.
facilities, including: power to be consumed locally or re-injected
• safety, through specially designed switch into the national grid.
disconnectors that cut the DC current
generated by solar panels regardless of
the facility configuration and operating
conditions,
• the reliability of DC facilities thanks to
solutions that prevent the degradation of
insulation and electric arc failure in the DC
current,
Energy Efficiency SOCOMEC solutions, ranging from sensors • limit reactive energy and prevent associated
to the wide choice of innovative, modular tariff penalties,
Improving building and facility energy
software packages, are driven by experts in • use the best tariffs, check supplier invoicing
efficiency
energy efficiency. They meet the essential and accurately distribute energy bills
requirements of managers or operators of amongst consumer entities.
tertiary, industrial or local authority buildings,
and make it possible to:
• measure power consumption, identify
sources of excess consumption, and raise
occupant awareness,
SOCOMEC solutions for For systems of any size The expert touch
photovoltaic applications cover any The different panel and conversion Certified quality products, continuous dialogue
technologies available today allow you to to understand customer requirements,
requirement for low-voltage energy
choose the most suitable solutions for any maximum flexibility and dedication right by
conversion, control and safety. application. SOCOMEC has the right solution your side. Our experience at your service.
Our inverters, monitoring, regardless of the application – residential,
building, solar park – and power.
supervision, disconnection and
protection systems, not forgetting Certified efficiency and reliability
the innovative storage and SOCOMEC has two testing laboratories
container solutions, provide for testing and validating the technology
developed and the solutions offered: one in
maximum quality and energy France, accredited by Cofrac for tests on the
efficiency for all types of equipment, and a 220 kW photovoltaic power
station in Italy.
photovoltaic systems.
Essential know-how
Photovoltaic systems are a long-term
investment. Different from each other in type
and electrical parameters, each installation
requires a detailed, complete analysis for
proper sizing of the components necessary
for conversion, distribution and management
of photovoltaic energy.
The integration of photovoltaic solar energy
production into an electrical energy system
therefore requires specific expertise for
maximum efficiency, safety and durability of
the system.
BODY 383 A
favourable.
A complete range
SOCOMEC SOLAR provides all the electrical
PV system equipment downstream of the
photovoltaic panels:
• DC panels,
• Smart string controllers,
• Inverters for photovoltaic systems,
• AC panels,
• Supervision solutions,
•S torage solutions,
• Container solutions.
BODY 336 A
SITE 408 A
Wider range of applications Building applications
Solar power has always been a natural and Photovoltaic systems for commercial use
renewable alternative energy source. It just can produce maximum peak power levels of
needs to be captured and then converted. hundreds of kWp.
The principles of PV have been known and The photovoltaic panels are usually installed
utilised for some time in space applications on roofs, terraces and the fronts of industrial
and solar powered calculators. However, it buildings, shopping centres or public
is only recently that the industry has made buildings, occupying a surface consisting of
real, rapid technological progress, making it between tens and hundreds of square metres.
possible for this energy source to become a
SUNSYS H inverters
Crucial for photovoltaic system performance, SUNSYS H (HOME) inverters are specific to residential
photovoltaic applications. Compatible with multiple configurations of solar modules, they have increased
conversion efficiency for maximum energy output.
Optimised ventilation
Dust and humidity have always been a problem for a system's electronic components.
In order to guarantee long life and stability of the inverter's function, the air required for cooling the
SUNSYS H inverters is channelled and pumped through a radiator located at the back of the inverter that
is completely isolated from other components.
Highly flexible
The wide range of input voltages, protection against polarity inversion of the photovoltaic strings and
monitoring of earth leakage guarantees extreme flexibility for planning and management of the system.
new
The solution for
Single-phase
Certifications
Advantages
5
installations with a power of 3 kW. YEARS
Efficiency in %
Level of efficiency 97
96
Maximum efficiency 97,10 % 95
EU efficiency 96,70 % 94
93
Consumption at night 1W 92
Maximum dissipated power 100 W 91
SUNSY 027 B GB
90
Maximum dissipated power 340 BTU/h 10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 86 kCal/h
Rated AC power (%)
General data
Protection class (according to EN 62109) Class I
Overvoltage category (according to EN 62109) Class III
Environmental category (according to EN 62109) External
Environmental degree of protection (according to EN 62109) IP 65
Type of DC connectors Sunclix (included)
Type of AC connector Bayonet connector (included)
Operating temperature -20 to +60 °C
Rated temperature -20 to +40 °C
Storage temperature -25 to +85 °C
Relative humidity 5% to 95% without condensation
Cooling system Natural convection
Sound emission < 36 dB 1 m from inverter
Altitude 0 to 2,000 m
Dimensions (L x D x H) 350 x 205 x 1,130 mm
Weight 34.5 kg
Certification and applicable standards CEI 0-21, VDE AR-N 4105, VDE 0126-1-1, UTE C15-712-1
Warranty 5 years (standard), 10/15/20 years (optional extension)
(1) The accepted tolerance depends on the country of installation and the regulations in force.
(2) Setup according to the requirements of the electricity supplier.
SELECT ENTER
SUNSY 059 A
SUNSY 058 A
4
3 5
1. LED
2. LCD Display
3. ENTER/SET button
2 4. Selection buttons
SUNSY 062 A
4. EXIT button
1. LCD Control panel
2. AC Output
3. DC Input
(1) Option.
DC AC
+ -
Q1 Q3 Type A differential
25 A 16 A C curve
600 V 500 V 30 mA
F2 Surgys F1 Surgys
F11
SUNSY 089 A GB
F1 F2
+ - N L
Output to AC network
5
6
7
Communication
Web
portal
B
S
U
USB firmware
update
ADSL Wireless
modem
REMOTE
Email notification MONITORING
service
LOCAL MONITORING
Advantages
SUNSY 084 A
WARRANTY
5
YEARS
Related products
Efficiency in %
LEVEL OF EFFICIENCY 97
96
Maximum efficiency 97,80 % 95
EU efficiency 97,20 % 94
93
Consumption at night 1W 92
Maximum dissipated power 140 W 91
SUNSY 027 B GB
90
Maximum dissipated power 470 BTU/h 10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 120 kCal/h
Rated AC power (%)
GENERAL DATA
Protection class (according to EN 62109) Class I
Overvoltage category (according to EN 62109) Class III
Environmental category (according to EN 62109) External Connections
Environmental degree of protection (according to EN 62109) IP 65
Type of DC connectors MC4 1
Type of AC connector Bayonet connector (included) 2
Operating temperature -20 to +60 °C
Rated temperature -20 to +40 °C
Storage temperature -25 to +60 °C
Relative humidity 5% to 95% without condensation
Cooling system Natural convection
Sound emission < 36 dB 1 m from inverter
Altitude 0 to 2,000 m
Dimensions (L x D x H) 470 x 167 x 482 mm
SUNSY 072 A
Weight 24 kg
Certification and applicable standards CEI 0-21, VDE AR-N 4105, VDE 0126-1-1, UTE C15-712-1
Warranty 5 years (standard), 10/15/20 years (optional extension)
(1) The accepted tolerance depends on the country of installation and the regulations in force. 3
(2) Setup according to the requirements of the electricity supplier. 4
5
Control panel 1. DC connectors
2. Display, buttons, LED
1 1. Green LED
3. Earth connection (PE)
2 2. Red LED
4. Communication connection
3. LCD Display
5. AC connector
4. ENTER: menu or enter selection
5. SELECT: page selection
SUNSY 071 A
3
4
5
new
The solution for
and solutions
Main advantages
BJB enclosure
4 Strings/1 MPPT
Conformity to standards(1)
COFF-PV_070
Specific requests
Functional diagram
RJB & BJB DC enclosures
RM PV - DC FUSE
Inverters
SIRCO MC PV
Electrical
network
From 1 to 6 PV strings
SURGYS G51-PV
coff-pv_085_b_1_gb_cat
* The 1 and 2-string RJB enclosures do not include any protection fuses in accordance with the UTE C 15-712-1 Guide.
SURGYS G51-PV
SIRCO MC PV
SURGYS G51-PV
coff-pv_086_c_1_it_cat
AC
Electrical
network
References
coff-pv_065
coff-pv_066
DC RJB
Number of strings MPPT number Voltage DC current AC current enclosure
Reference
1 1 600 VDC 25 A 34PV 6211
2 1 600 VDC 25 A 34PV 6221
2 2 600 VDC 25 A 34PV 6222
1 1 1,000 VDC 25 A 34PV 1211
2 1 1,000 VDC 25 A 34PV 1221
2 2 1,000 VDC 25 A 34PV 1222
coff-pv_069
AC-DC RJB
Number of strings MPPT number Voltage DC current AC current enclosure
Reference
2 1 600 VDC 25 A 16 A 35PV 6221
2 2 600 VDC 25 A 16 A 35PV 6222
2 1 600 VDC 25 A 25 A 35PV 6321
2 2 600 VDC 25 A 25 A 35PV 6322
2 1 1,000 VDC 25 A 16 A 35PV 1221
2 2 1,000 VDC 25 A 16 A 35PV 1222
2 1 1,000 VDC 25 A 25 A 35PV 1321
2 2 1,000 VDC 25 A 25 A 35PV 1322
coff-pv_068
DC BJB
Number of strings MPPT number Voltage DC current AC current enclosure
Reference
3 1 600 VDC 40 A 36PV 6431
4 1 600 VDC 40 A 36PV 6441
4 2 600 VDC 25 A 36PV 6242
3 1 1,000 VDC 40 A 36PV 1431
4 1 1,000 VDC 40 A 36PV 1441
4 2 1,000 VDC 25 A 36PV 1242
6 1 1,000 VDC 80 A 36PV 1661
6 2 1,000 VDC 40 A 36PV 1462
Configurations
Type of Type of
enclosure Configuration Diagram enclosure Configuration Diagram
DC
BJB
RJB
DC BJB DC 4 PV strings - 2 MPPT DC
DC
BJB DC
New configuration 3 x 4 strings/3 MPPT available (please contact SOCOMEC for information).
Crucial for photovoltaic system performance, SUNSYS B (BUILDING) inverters are specific to commercial
photovoltaic applications. The systems on roofs with large surfaces require additional functions, and
provide greater power compared to residential systems. In particular, the photovoltaic inverters must be
connected to a centralised management system for optimum output from the system.
The inverter is used in different ways, depending on the size of the installation and the choice of
architecture:
• The PV strings are connected in parallel to a single centralised inverter,
• Each PV string is connected to its own inverter,
• Different groups of strings are managed by a single inverter with modular architecture.
Control panel
The graphic display present on the inverter provides a maximum of system data, supplying detailed status
messages and daily production graphs for quick and accurate analysis of the system.
RS485 interface
The RS485 connection allows for monitoring of the system with local or remote supervision systems and
ensures a complete overview of system data from any workstation.
Signalling contacts
Buzzers and visual signalling contacts notify any changes in the system and inverter status.
Advantages
SUNSY 047 B
WARRANTY
5
YEARS
Related products
The best, high-efficiency Benefits of the SUNSYS B10 > BJB photovoltaic enclosures,
performance solution page 16
• The SUNSYS B10 inverter is the ideal • MPPT's extensive voltage tolerance allows
solution for photovoltaic applications on for excellent flexibility in combination with
buildings with a power of 10 kW. photovoltaic modules.
• The transformerless design offers a • The IP65 degree of protection makes it
conversion efficiency which is amongst the suitable for installation in both indoor and
best on the market. outdoor environments.
• The double tracker series input provides:
- optimisation of the system's energy Communication and supervision
production,
• Equipped with LCD control panel with a
- maximisation of the output of extended roof
multilingual menu: English, French, German,
systems with several layers, systems with
Spanish and Italian (for other languages,
different orientations, systems with areas of
contact SOCOMEC).
shade,
• Optional RS485 connection for simple and
- management of a system divided into
immediate monitoring of the system.
sections with different photovoltaic module
technologies with a single inverter. • User-friendly.
Topology No transformer 99
Efficiency in %
LEVEL OF EFFICIENCY 98
97
Maximum efficiency 97.90%
96
EU efficiency 97.10%
95
Consumption at night 1W
94
Maximum air demand 100 m3/h
SUNSY 028 B GB
93
Maximum dissipated power 290 W 10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 990 BTU/h
Rated AC power (%)
Maximum dissipated power 250 kCal/h
GENERAL DATA
Protection class (according to EN 62109) Class I
Overvoltage category (according to EN 62109) Class III Connections
Environmental category (according to EN 62109 External
Environmental degree of protection (according to EN 62109) IP 65 1
Type of DC connectors MC4 2
Type of AC connectors Screw terminals
Operating temperature -20 to +60 °C
SUNSY 070 A
Advantages
SUNSY 083 A
WARRANTY
5
YEARS
SUNSY 082 A
Related products
Benefits of the SUNSYS B12, Communication and supervision > BJB photovoltaic enclosures,
B15, B20, B30 solution page 16
• High-resolution LCD display with a
• MPPT's broad voltage tolerance provides multilingual menu: English, French, German,
excellent flexibility in combination with Spanish and Italian (for other languages,
photovoltaic modules. contact SOCOMEC).
• The IP65 degree of protection makes it • Equipped with graphic LCD control panel
suitable for installation in both indoor and with a datalogger and RS485 connection
outdoor environments. for simple and immediate monitoring of the
system.
The best, high-efficiency
performance
• The SUNSYS B12, B15, B20 and
B30 inverters are the ideal solution for
photovoltaic applications on buildings with a
power between 12 and 30 kW.
• The transformerless design offers a
conversion efficiency which is amongst the
best on the market.
• The double tracker series input provides:
- optimisation of the system's energy
production,
- maximisation of the output of extended
roof systems with several layers, systems
with different orientations, systems with
areas of shade,
- management of a system divided into
sections with different photovoltaic module
technologies with a single inverter.
Efficiency in %
Topology No transformer 98
97
LEVEL OF EFFICIENCY
96
Maximum efficiency 98.10 %
95
EU efficiency 97.5 % 97.60 %
94
Consumption at night 2W
SUNSY 028 B GB
93
Maximum air demand 80 m /h3
320 m /h
3
10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 300 W 360 W 480 W 720 W
Rated AC power (%)
Maximum dissipated power 1,025 BTU/h 1,230 BTU/h 1,620 BTU/h 2,460 BTU/h
Maximum dissipated power 260 kCal/h 310 kCal/h 410 kCal/h 620 kCal/h
GENERAL DATA
Protection class (according to EN 62109) Class I Connections
Overvoltage category (according to EN 62109) Class III
Environmental category (according to EN 62109) External 1
Environmental degree of protection (according to EN 62109) IP 65 2
3
Type of DC connectors MC4
4
Type of AC connector Bayonet connector (included) 5
Operating temperature -20 to +60 °C
Rated temperature -20 to +40 °C
Storage temperature -25 to +60 °C
Relative humidity 5% to 95% without condensation
Cooling system Smart cooling
< 50 dB 1 m from < 61 dB 1 m
Sound emission < 55 dB 1 m from inverter
inverter from inverter
Altitude 0 to 2,000 m
SUNSY 075 A
weather conditions.
100
99
98
Efficiency as %
97
96
% load % load
SUNSY 078 A GB
SUNSY 079 A GB
95
94
93
92 % load % load
91
90
10 20 30 40 50 60 70 80 90 100
% load % load
efficiency.
SUNSY 051 A
Rack 33 kW
SUNSY 077 A
Certifications
Advantages
5
ranging between 33 and 66 kW. The inverter starts to produce electricity at YEARS
LEVEL OF EFFICIENCY 98
Efficiency in %
Maximum efficiency 97 % 96
94
EU efficiency 96 %
92
Consumption at night 10 W
90
Maximum air demand 480 m /h3
1,280 m /h
3
88
SUNSY 029 C GB
Maximum dissipated power 1,750 W 3,500 W 86
10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 5,980 BTU/h 11,950 BTU/h
Maximum dissipated power 1,500 kCal/h 3,000 kCal/h Rated AC power (%)
GENERAL DATA
Protection class (according to EN 62109) Class I
Overvoltage category (according to EN 62109) Class III
Environmental category (according to EN 62109) Non-air-conditioned internal environments
Connections
Environmental degree of protection (according to EN 62109) IP 20
Copper bars for cables Copper bars for cables 1
Type of DC connectors
from 25 mm2 to 120 mm2 (M8) from 50 mm2 to 120 mm2 (M8) Module A
Copper bars for cables Copper bars for cables
Type of AC connectors
from 16 mm2 to 120 mm2 (M8) from 35 mm2 to 120 mm2 (M8) 2
Operating temperature -5 to +60 °C
Rated temperature -5 to +45 °C 3 Module B
Storage temperature -5 to +60 °C
Relative humidity 5% to 95% without condensation
Cooling system Smart cooling
Sound emission < 60 dB 1 m from inverter < 64 dB 1 m from inverter 4
5
Altitude 0 to 1,000 m 6
Dimensions (L x D x H) 600 x 795 x 1,400 mm
Weight 330 kg 525 kg 7
Certification and applicable standards CEI 0-21, CEI 0-16, VDE AR-N 4105, VDE 0126-1-1, UTE C15-712-1
8
Warranty 5 years (standard), 10/15/20 years (optional extension) 9
SUNSY 091 A
(1) The tolerance accepted depends on the country of installation and the regulations in force.
(2) Setup according to the requirements of the electricity supplier.
Control panel
1. LCD graphic display
2. Navigation buttons 1. Communication slot
3. Inverter status light bar 2. Module A output isolator
1 3. Module B output isolator
4. Isolators with fuse
5. IEC320 AUX output for assistance
6. IEC320 AUX power supply input
7. Inverter output isolator
8. Module B input isolator
SUNSY 088 A
2
3 9. Module A input isolator
Certifications
SUNSY 056 A
Advantages
5
100 kW power. The inverter starts to produce electricity at YEARS
Efficiency in %
96
Maximum efficiency 97 % 94
EU efficiency 96 % 92
Consumption at night 10 W 90
SUNSY 029 B IT
86
Maximum dissipated power 5,250 W 10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 17,900 BTU/h
Rated AC power (%)
Maximum dissipated power 4,500 kCal/h
GENERAL DATA
Protection class (according to EN 62109) Class I
Overvoltage category (according to EN 62109) Class III Connections
Environmental category (according to EN 62109) Non-air-conditioned internal environments
Environmental degree of protection (according to EN 62109) IP 20
Type of DC connectors Copper bars for cables from 95 mm2 to 120 mm2 (M8) 1 Module A
Type of AC connectors Copper bars for cables from 70 mm2 to 120 mm2 (M8)
Operating temperature -5 to +60 °C
2
Rated temperature -5 to +45 °C
5
Storage temperature -5 to +60 °C 3 Module B
Relative humidity 5% to 95% without condensation
Cooling system Smart cooling 4
Sound emission < 64 dB 1 m from inverter
6 Module C
Altitude 0 to 1,000 m
7
Dimensions (L x D x H) 1,200 x 795 x 1,400 mm
8
Weight 770 kg 9
Certification and applicable standards CEI 0-21, CEI 0-16, VDE AR-N 4105, VDE 0126-1-1, UTE C15-712-1 10
Warranty 5 years (standard), 10/15/20 years (optional extension) 11
(1) The accepted tolerance depends on the country of installation and the regulations in force.
SUNSY 092 A
Control panel
1. Communication slot
1. LCD graphic display 2. Module A output isolator
2. Navigation buttons 3. Module B output isolator
3. Inverter status light bar 4. Module C output isolator
1 5. Inverter output isolator
6. Isolators with fuse
7. IEC320 AUX power supply input
8. IEC320 AUX output for assistance
9. Module C input isolator
10. Module B input isolator
SUNSY 088 A
2
3 11. Module A input isolator
installations
Certifications
Advantages
5
greater than 66 kW. The inverter starts to produce electricity at YEARS
Efficiency as %
97
Maximum efficiency 98 % 96
95
EU efficiency 97.6 % 94
Consumption at night 10 W 93
92
Maximum air demand 960 m3/h 1,440 m3/h 91
90
Maximum dissipated power 2,470 W 3,650 W 10 20 30 40 50 60 70 80 90 100
Maximum dissipated power 8,420 BTU/h 12,450 BTU/h AC power rating (%)
SUNSY 030 B GB
Maximum dissipated power 2,130 kCal/h 3,150 kCal/h
Efficiency without DPC
GENERAL DATA Efficiency with DPC
Protection class (according to EN 62109) Class I
Overvoltage category (according to EN 62109) Class III
Environmental category (according to EN 62109) Non-air-conditioned internal environments
Environmental degree of protection (according to EN 62109) IP 20 Connections
Copper bars for cables Copper bars for cables
Type of DC connectors
from 50 mm2 to 120 mm2 (M8) from 95 mm2 to 120 mm2 (M8) 1
Module A
Copper bars for cables Copper bars for cables
Type of AC connectors
from 35 mm2 to 120 mm2 (M8) from 70 mm2 to 120 mm2 (M8) 2
Operating temperature -5 to +60 °C
Rated temperature -5 to +45 °C 3 Module B
Storage temperature -5 to +60 °C
4
Relative humidity 5% to 95% without condensation
Cooling system smart cooling 5 Module C
Sound emission < 64 dB 1 m from inverter 6
7
Altitude 0 to 1,000 m
8
Dimensions (L x D x H) 600 x 795 x 1,400 mm
9
Weight 155 kg 190 kg
SUNSY 093 A
10
Certification and applicable standards CEI 0-21, CEI 0-16, VDE AR-N 4105, VDE 0126-1-1, UTE C15-712-1
Warranty 5 years (standard), 10/15/20 years (optional extension)
(1) The accepted tolerance depends on the country of installation and the regulations in force.
(2) Setup according to the requirements of the electricity supplier.
1. Communication slot
Control panel 2. Module A output isolator
3. Module B output isolator
1. LCD graphic display
4. Module C output isolator
2. Navigation buttons
5. Isolators with fuse
3. Inverter status light bar
1 5. IEC320 AUX power supply input
7. IEC320 AUX output for assistance
8. Module C input isolator
9. Module B input isolator
10. Module A input isolator
SUNSY 088 A
2
3
new
installations (large buildings,
fields, solar parks ranging
from a few hundred kW to
many MW)
Main advantages
COFF-PV_023_B
Conformity to standards
16-string enclosure
General description
The FJB/IFB range was designed with a modular architecture consisting of:
coff-pv_057_a_cat
coff-pv_059_a_cat
coff-pv_061_a_cat
coff-pv_063_a_cat
coff-pv_078_a_cat
8 strings 12 strings 16 strings 24 strings 32 strings
2 (consult us).
3 - Connection of the strings 3
on the PV RM fuse
isolator. 7 - Polyester enclosure IP65,
- gPV protection fuse 5 7 IK09
(10 x 38) for the - Colour RAL 7035
photovoltaic string. - Mounting support
on wall bracket
- Safety stickers
Functional diagram
FJB/IFB Box
Photovoltaic modules
RM PV - DC FUSE
Inverter
SIRCO PV
Electrical
network
coff-pv_077_b_1_gb_cat
From 8 to 32 strings
SURGYS G51-PV
References
Accessories
gPV fuse 10 x 38
Size Reference
Size from 2 to 16 A Contact SOCOMEC
fusib_168_a
Release coils
Description Reference
No-volt release coil 208-240 V/50-60 Hz SUN-OP-UV230VAC
Shunt release coil 208-250 VAC/DC SUN-OP-ST230VAC
Dimensions
8 strings
540
540
coff-pv_079_a_1_cat
12 strings
720 198
540
coff-pv_080_a_1_cat
16 strings
540 270
540
coff-pv_081_a_1_cat
Dimensions
24 strings
540 540
540
coff-pv_082_a_1_cat
32 strings
198
Large photovoltaic installations require constant monitoring of the energy production and operational
parameters.
The SUNGUARD monitoring system is compatible with all SUNSYS inverters and allows:
• Monitoring of the photovoltaic plant with a PC or mobile device (tablet, smartphone, etc.)
with an Internet connection and browser,
• Checking of the daily production, the profitability of the plant and the contribution to environmental
protection,
• Reduction of production downtime.
Photovoltaic
SUN
SYS
panels
SUNSYS IFB
SUNSYS
Inverter
DIRIS
SUNGUARD
Data Logger
ADSL modem
(not supplied)
Notification
SUPVI 006 A IT
(email/SMS)
portal via the ADSL router/modem (Ethernet • 24 VDC power supply not included.
port) or UMTS/3G SUNGUARD router/ • 4 Gb CompactFlash with pre-installed
modem. The Reserved Area of the portal software to manage the monitoring system.
can be accessed with any Web Browser • Aluminium enclosure.
and an Internet connection, to monitor and
• Installation on DIN rail or on wall.
analyse all the photovoltaic installations fitted
with the SUNGUARD datalogger. • Dimensions (L x D x H): 71 x 139 x 152 mm.
• Weight: 1.0 kg.
• Operating temperature:
-20 to +75 °C.
Switchboard IP65 8 modules: power supply, data line overvoltage discharge, magnetothermal switch
Switchboard specifications Data line surge protection device
• Switchboard 8 modules. specifications
• Protection IP65. • Network rated voltage: 6 V.
• Dissipated power: 16 W. • Maximum network voltage: 8 V.
• Colour: grey RAL 7035. • Level of Protection: 25 V.
• Dimensions (L x D x H) • Rated discharge current: 5 kA.
215 x 100 x 210 mm. • Maximum discharge current: 20 kA.
• Current impulse: 5 kA.
Power supply specifications
• Installation on DIN rail.
• Input voltage: 230 VAC. • Dimensions (L x D x H) 18 x 68 x 90 mm.
• Frequency range: 50-60 Hz. • Earth connection: clamps and DIN rail.
• Output voltage: 24 V. • Clamp section: 0.4-1.5 mm2.
• Rated output current: 2.5 A.
SUNSY 019 A
• Degree of protection of the sensors: IP65. automatic comparison with the power
• Dimensions (L x D x H): 220 x 140 x generated by the photovoltaic installation.
140 mm. • Two or more SUNGUARD SENSOR BOXES
• Connectable sensors: can be connected to the same Bus line.
- sunlight sensor,
- module temperature sensor,
- ambient temperature sensor,
- wind gauge.
• Inputs:
- mV input (range 0-10) for radiation sensor,
- 2-wire or 3-wire PT1 and PT2 inputs for
module temperature sensor and ambient
temperature sensor,
- wind gauge input.
Sunlight sensor
Specifications Operation
• Range of measurement: 0 to 1,500 W/m². • The sunlight sensor, fitted with a
• Type of sensor: monocrystalline cell (20- monocrystalline cell (13 x 33 mm), measures
24 mm). sun exposure on the basis of the angle and
• Precision of the sensor: ±5% on a yearly orientation of the photovoltaic modules. It
basis. can be used in all weather conditions.
• Electrical output: 75 mV to 1,000 W/m². • It should be connected to the Sensor Box
SUNGUARD at a maximum distance of
• Sensor: Novaflon laminate and EVA foil.
SUPVI 017 A
2.5 m.
• Enclosure: Z-profile aluminium corner,
sealed connection head.
• Degree of protection: IP65.
• Type of connection: cable 3 m, 2 x 1.0 mm².
• Assembly: 6 mm perforation for screw
mounting.
• Dimensions (L x D x H): 55 x 55 x 10 mm.
• Weight: 200 g (cable included).
SUPVI 014 A
• Degree of protection: IP65.
• Type of connection: 2.5m cable,
connection for two conductors.
• Dimensions (L x D x H): 52 x 50 x 32 mm.
• Weight 120 g.
Wind gauge
Specifications • Dimensions (Ø x h) 123.6 x 138.5 mm.
• Power supply voltage: 5 to 24 VDC. • Weight: 154 g (wind gauge only), 1.25 kg
• Maximum current: 15 mA. (wind gauge + 20 m cable).
• Speed range: 2 to 200 km/h. • Aluminium mounting bracket included.
• Speed resolution: > 1 km/h.
Operation
• Precision: ±2%.
• The wind gauge is required in installations
• Repeatability: 0.5%.
based in windy areas in order to monitor
• Linearity: ±2%. rapid reductions in energy production
• Degree of protection: IP65. caused by strong gusts of wind.
SUPVI 013 A
• Operating temperature:
-20 °C to +80 °C.
Router/modem
ROUTER 3G-PRO
Specifications - SPI Firewall, IP/Service Filter, URL Blocking,
• WAN Wireless: MAC control,
- Integrated 3G UMTS module; - DoS (Denial of Service) detection and
- HSUPA speed (7.2 M Down, 5.76 M Up); protection,
- supporting EDGE/GPSR Class 12. - static and dynamic routing, DynDNS,
• WAN Ethernet: - supporting VPN Passthrough for IPSEC,
PPTP and L2TP,
- RJ45, 10-100 Mbps, auto MDI/MIDX,
- sending and receiving SMS from WEB
- Static IP, PPPoE, Client DHCP, PPPTP,
interface,
L2TP.
- local and remote configuration from WEB
SUPVI 0115 A
SUN-WM-DY-EXT
Specifications • Number of colours: 1 (amber).
• External dimensions (L x D x H): • Mounting the display: brackets for wall
1,500 x 75 x 700 mm. installation, screws and steel mounting.
• Weight: 15 kg. • Brightness adjustment: automatic by means
• Display structure: aluminium. of a twilight sensor.
• Power supply voltage: 220 V 50 Hz.
SUNSY 021 A
• Anti-glare screen.
• For outdoor mounting. • Communication: via RS485, Modbus/LAN
• Pixels: High-brightness LED. Ethernet connection.
• Character size: 65 x 91 mm, size 13 mm. Operation
• Number of lines: 2.
• SUNGUARD LED DISPLAY is an external
• Number of characters on display: Total 32. monitor that is directly connected to the
• Number of characters on first alphanumeric network through the Ethernet port, allowing
line: 16. operating data of the monitored photovoltaic
• Number of characters on second installation to be viewed in real time. Up
alphanumeric line: 16. to 15 variables can be viewed (e.g. total
• LED writing height: 91 mm. energy, instantaneous power, number of
• Type of display: scrolling pages or trees saved, CO2, equivalent number barrels
characters (512 max). of oil, etc.)
• Visibility: from 1 to 40 m.
• Number of pixels: 1 344.
SUNSY 022 A
• For indoor mounting.
• Contrast: 3500:1.
• Colour: black.
• Viewing angle: 178° max.
• Weight: 11.95 kg.
• Interface: DVI-D, HDMI, S-Video, VGA.
• Communication data: LAN, WLAN, UMTS, Operation
GPRS.
• SUNGUARD INFO DISPLAY is an internal
• Datalogger: included (SG-VIDEO-DISPLAY). monitor that is directly connected to the
• PV installation data display: total energy network through the Ethernet port, allowing
produced, equivalent number of barrels of the operating data of one or more monitored
oil, number of trees saved, CO2 emissions photovoltaic installations to be viewed in real
avoided, daily energy (numerical value and time.
progress graph), activation data, maximum
power and total energy produced.
256 A RANGE
DIRIS 743 A
Check that the slots are of the correct size and are operating advanced metering.
• • • • •
correctly
Check energy distribution • • • • •
• Individual harmonics up
Check and ensure the distribution of energy is correct - - • • •
to level 63.
Check and control any disturbance - - • • • • RS485 communication
Detect and store any hazardous events for the installations - - - • • (Jbus/Modbus and Profibus-
Monitor the differential currents and earth fault currents DP) and Ethernet (Modbus
- - - - • TCP and Jbus/Modbus over
depending on the load
96 x 96 96 x 96 96 x 96 96 x 96 TCP).
Dimensions 4 modules
built-in built-in built-in built-in • Additional module options.
• Alert management.
• Indication of power
Functions forecasting.
• 96 x 96 mm casing.
DIRIS DIRIS DIRIS DIRIS DIRIS
• Conforms to UL 61010-1.
A10 A20 A40/A41 A60 A80
MEASUREMENTS DIRIS A60
Currents, Voltages, Frequency, Active, reactive and apparent • Same functions as
• • • • •
power, Power factors
DIRIS 824 A
DIRIS A40.
Power forecasting - - • • •
Voltage/current imbalance; Tangent - - - • •
• Average power load
curves (P, Q, S).
Temperature • - 1 to 4 option 1 to 4 option • Detection of overvoltage,
Currents, voltages and average frequency - - • • • voltage dips and
Average power - - • • • interruptions.
I∆N and IPE currents - - - - • • Overcurrent detection.
SOLUTIONS FOR ENERGY MANAGEMENT • History of RMS 1/2 period
Energy meters (cl. 0.5S IEC 62053-22; curves associated with
• • • • •
cl. 2 IEC 62053-22)
events.
Impulse meters 1* - 2 to 6 option 2 to 6 option - • Tangent .
Load curve - - • • • • Voltage and current
QUALITY ANALYSIS AND EVENT DETECTION imbalance.
DIRIS 876 A
Up to level Up to level Up to level Up to level Up to level
THD 3U, 3V, 3 I/In
51 51 63 63 63
DIRIS A80
Individual harmonic components up to level 63 - - • • • • Same functions as
Overvoltage, voltage dips, interruptions - - - • • DIRIS A60.
Storing of the RMS 1/2 period curve - - - • • • Permanent monitoring of
differential currents and earth
Alarm output 1* 1* optional 2 to 6 option 2 to 6 option 1 to 2 option
leakage.
HISTORY LOG OF MEASUREMENTS AND EVENTS • Dynamic alarm threshold as a
Load curve - - Optional • • function of the load.
Events/Alarm - - - /• •/• •/•
Average maximum power kW kW • • •
Average maximum current • • • • •
* 1 configurable
Standard functions
DIRIS A10 DIRIS A20
• Multi-function • Multi-function
measurement and measurement and
DIRIS 744 A
metering. metering.
DIRIS 791 B
SOCOMEC uses its know-how to design and develop customised solutions for the management of
energy production and storage when standard solutions do not meet the individual needs of customers,
requiring projects that are tailor-made for each facility.
SUNSYS SHELTER is a tailor-made integrated solution that is installed between the photovoltaic park and
MV (medium voltage) network for the conversion of solar energy.
SUNSYS STORAGE is an innovative energy storage solution that maximises the output of photovoltaic
facilities and integrates them into the electricity grid.
SHELT 003 A
MV protection
Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter units
1 2 3 4 5 6 7 8 9
LV protection
enclosures
Transformer
SHELT 005 A GB
APPLI 560 A
APPLI 561 A
APPLI 562 A
new
Customised
Advantages
WARRANTY
5
YEARS
SUNSY 056 A
SUNSY 054 A
Output rated frequency 50 Hz(1)
Output frequency range 47.5 to 51.5 Hz(1)
Rated output current 48 Arms 96 Arms 144 Arms
Maximum output current 53 Arms 106 Arms 160 Arms
Total harmonic distortion of current < 3%
Single conversion
Topology
Output transformer 50 Hz
Level of efficiency
Maximum efficiency 97%
EU efficiency 96%
General data
Environmental category Non-air-conditioned internal environments
Environmental degree of protection IP 20
Operating temperature range -5 °C to +60 °C
Rated temperature range -5 °C to +45 °C
Storage temperature range -5 °C to +60 °C
Relative humidity range 5% to 95% without condensation
Cooling system Smart cooling
Sound emission < 60 dB 1 m from inverter < 64 dB 1 m from inverter
SUNSY 056 A
SUNSYS LITHIUM
• High rapid discharge performance (peak shaving applications).
• High energy density.
• Highly compact.
• Easy scalability.
• Easy to maintain (hot-swap plug-in).
• Long life cycle.
• Maintenance-free.
• Zero environmental impact.
SUNSYS-LT-33 SUNSYS-LT-42
Technology Lithium-ion
Rated capacity 33 kWh 42 kWh
Rated voltage 616 V 784 V
SUNSY 055 A
Rated load time: 4h
Environmental degree of protection IP 20
Load temperature range -0 °C to +40 °C
Discharge temperature range -20 °C to +60 °C
Recommended operating temperature 25 °C
Dimensions (L x D x H) 600 x 795 x 1,400 mm 600 x 795 x 1,925 mm
SUNSYS LEAD
• High performance (e.g. maintaining battery charge, high number of charge/discharge cycles, etc.)
• High energy density.
•S olution suitable for fast charge systems.
• Suitable for installations in harsh environments.
• Highly compact.
• Easy to service.
• No maintenance contract.
SUNSYS-LA-22
Technology Lead
Rated capacity 22 kWh
Rated voltage 528 V
Rated charging time 4h
Environmental degree of protection IP 20
Charging temperature range -0 °C to +40 °C
Discharge temperature range -20 °C - +60 °C
Recommended operating temperature 25 °C
Dimensions (L x D x H) 600 x 795 x 1,400 mm
A photovoltaic installation is composed of photovoltaic modules, one or more inverters, and isolation and
protection devices.
Depending on the photovoltaic module technology and the size of the installation, the isolation and
protection devices can be integrated into cabinets or photovoltaic string control enclosures.
electric shock. inverter, only SIRCO PV devices are capable currents that vary according to daily solar
of: radiation.
SIRCO MC PV 25 and 40 A
Function General characteristics
SIRCO MC PV devices are manually • Modular and flexible device.
operated multipolar load break switches. • AC/DC device for complete isolation of
They ensure opening/closing under load the inverter thanks to the simultaneous
and safely disconnect any low voltage cut-off of the DC current input and AC
electrical circuit for PV systems. current output.
SIRCO MC 002 A
SIRCO MV PV 63 to 160 A
Function General characteristics
SIRCO MV PV devices are manually • Modular device.
operated multipolar load break switches. • Fully visible opening.
They ensure opening/closing under load • Rail mounting, panel or modular panel
and safely disconnect any low voltage with 45 mm front cut-out.
SIRCM-PV 010 A
SIRCO-PV 016 A
• Padlocking in position 0 (I optional).
circuit for PV systems. • Up to 1,000 V DC.
Compliance with standards • IP20 devices and accessories.
• SIRCO MOT PV have up to 3 and 4 poles
• IEC 60947-3.
from 200 to 630 A.
• SIRCO MOT PV have a manual emergency
command.
RM PV 20 to 50 A
Function General characteristics
RM PV are disconnectors with unipolar • Rated voltage 1,000 VDC.
or bipolar modular fuses for 10 x 38 and • Multipolar and simultaneous disconnection.
14 x 51 cylindrical fuses. They ensure • High dielectric withstand.
safe disconnection and protection against • Modular DIN 45 mm cut-out.
overcurrents in all PV electrical circuits on the
• Self-extinguishing thermoplastic material.
DC current side.
• High-capacity connection.
RM: fuse bases without signalling for fuses
RM PV 005 A
without striker.
• DIN 43620.
SURGYS G51-PV
Function General characteristics
The SURGYS G51-PV surge protective device • Type 2 Surge Protective Device.
is designed to protect your photovoltaic • Available with protection from 500 VDC to
against atmospheric voltage surges. 1,500 VDC.
It complies with the UTE 61-740-51 test • Maximum discharge current 40 kA.
guidelines and the UTE 15-712 installation • Monobloc base.
guidelines of July 2010. • Common mode/differential mode protection.
SGYS 076 A
SURGYS D40
Function General characteristics
The SURGYS D40 surge protective device • Type 2 Surge Protective Device.
is designed to ensure the protection of LV • Maximum discharge current 40 kA.
distribution circuits and equipment against • Common mode/differential mode protection.
transient overvoltages. • Monobloc base.
It acts against the overvoltages produced by • Extractable remote signalling contact.
industrial processes or lightning.
• End of service life indicator.
SGYS 069 A
> Service sector
> Industry
Services
> Telecommunications
> Medical
> Etc.
appli 143 a
Availability of parts
CARTE 021 A
Readily available genuine spare parts and
components guarantee that any faulty
equipment can be rapidly and efficiently
retrieved, while maintaining performance and
reliability.
CIM Thermo(1)
Thermal technology for precise monitoring
of the electrical installation.
Our CIM Thermo service consists of checking • transformers, • terminals,
the components of your electrical facility • electrical switchboards, • protection devices, isolators, fuses, circuit
with specialist equipment (Thermal Imaging • rephasing systems breakers,
Camera). It is therefore possible to perform • distribution cables, • UPS, photovoltaic inverters and converters,
a preventative diagnosis of the risk of faults • batteries,
• joints,
by analysing the temperature (thermographic
• connections, • loads (motors and actuators, lighting).
control) of the components including:
• clamps,
defys 114 a
APPLI 193 a
APPLI 195 a
Transformer inspection Inspection of UPS, photovoltaic inverters and converters Switchboard inspection
Infrared thermography
Thermography, also known as thermal
imaging, is a technique that allows detection
of infrared radiation produced by hot objects.
Infrared cameras are used to detect and
photograph this radiation, enabling non-
invasive analysis of the temperature of an
object with a high level of precision (up to
1/10th of a degree).
cim 008 a
cim 009 a
CIM Thermo(1)
Infrared thermographic camera Key benefits that make the difference
The particular model of thermal camera used The CIM Thermo thermography service offers SOCOMEC proposes a complete end-to-end
by our technicians to inspect components the following benefits: diagnostic service:
stores images and sequences for comparison • Preventative: • Analysis: visual check of the environment,
with future checks. - fault prevention, installation and equipment,
The thermal camera identifies the - highly effective diagnostics thanks to • fault identification: readings taken from the
critical components requiring immediate the checking of cable connections and equipment using thermographic cameras to
maintenance or simple verification. terminals, which is impossible using identify and quantify faults,
conventional visual checks, • Solutions: identification of defective
- maximum diagnostic reliability thanks to total components and improvement solutions,
system control, from the main distribution • Repairs: implementation of proposed
panel to the smallest functional details, solutions,
- greater safety for personnel, users and • Measurement of results: effectiveness of
customers. applied solutions checked by comparing
• Reduction of costs: them with measurements taken before
maintenance using dedicated software
- reduction of costs caused by faults and
programme.
power loss, which are prevented by
ensuring the efficiency and effectiveness of • Report: definitive technical reports indicating
installations, the list of identified critical points, the state
of the installation and the recommended
- reduction of costs caused during installation
APPLI 197 a
frequency of monitoring.
downtime.
• Uninterrupted power supply: Contract options
- scheduled stop times and targeted SOCOMEC proposes a variety of contract
Application software for the thermographic maintenance interventions, options to suit your needs:
analyser - uninterrupted power thanks to checks • general: for the detection of faults and
The thermal images are displayed using carried out with the facility during operation, critical points,
thermographic software. without cutting off the power supply. • monitoring: for checking the effectiveness of
By comparing the various images, customised
maintenance procedures,
reports can be created for further analysis.
• periodic: for the monitoring of critical areas.
Temperature gradients, displayed as graphs
and tables, facilitate future checks and the
creation of reports identifying each critical
component.
Couv 142 a
CIM leasing(1)
Inverter leasing: your temporary solution Specific needs
for high-quality power supply To activate the lease, simply specify:
Need high-quality, uninterrupted electrical • the required power,
energy for a limited period of time (weeks or • the number of inverters,
months)? Then leasing is the most economical • the lease period,
solution for your short-term needs.
• the site/address of installation,
Leasing enables you to draw on the global
• any additional options,
expertise of SOCOMEC, not only ensuring
inverter availability, but also providing you with • related services.
an all-inclusive service to guarantee a clean,
Standard services included in the lease
uninterrupted energy supply.
• Environmental consultancy: ventilation,
The user chooses the required power and
positioning, electrical distribution and
lease term, which can be extended as
appli_135_a
protection ratings,
needed.
• Transport,
You no longer need to spend time and
resources on inverter management: the • Commissioning,
Advantages
CIM service (Consulting, Inspection and • Call centre (freephone),
• Reduced investment: solution supplied
Maintenance) will take care of everything, from • Next-day repair service, with a reduced operating budget, with no
activation to maintenance, including removal • Inverter dismantling and removal. obligation to purchase,
at the end of the contract.
• Quick: rapid delivery and commissioning,
Additional services
Applications • Simple: leasing, transport, commissioning
• On-site maintenance,
• Data processing, and return of materials included,
• Installation and cabling,
• Event-based technical platforms. • Ready: priority response from the
• Maintenance response within 6 hours or the SOCOMEC after-sales service in the event
• Sound and lighting consoles, next working day, of faults,
• Industrial processes. • 24-hour on-call maintenance, • Compliance with legislation: guaranteed by
• Training for operational personnel. SOCOMEC,
Events
• Temporary work phases, • Tax benefits: leasing fees can be allocated
to an operating budget.
• Unforeseen damage, accidents, etc.,
• Exhibitions and shows,
• When investment is not possible.
• related services.
SERVICE course
Operations necessary for the commissioning of inverters and related
accessories.
ADVANCED course
Technical-commercial update on the Sunsys inverter range.
Suitable for those who have completed the Service course.
sydiv 010 a
Training specifically for sales reps
SALES course
Advantages and special features of the SOCOMEC offer, decision criteria
and comparison of the different architectures, benefits for contractors.
Specifically for those who have completed the Basic course.
SYDIV 037 a
Content
• Solar radiation, characteristics and photovoltaic module technology.
• Inverter architecture and technology.
• Architectures: string, centralised and modular.
• Presentation of the SUNSYS H, SUNSYS B and SUNSYS P ranges.
• Presentation of the SUNSYS IFB field boxes.
• Sizing (e.g. for residential and industrial installations).
• PV CAD.
• Local and remote monitoring: specifications and choice of components.
• Communication: SUNSYS H and SUNSYS P supervision.
• SOCOMEC references.
Aimed at
• Designers and contractors.
• Architects, surveyors and energy managers.
• Retailers/Wholesalers interested in photovoltaics.
• SOCOMEC's commercial partners.
Level required
• Basics of electronics and electrical systems.
Note
• Maximum number of participants: 15 people.
• Includes end-of-test course and certificate of attendance.
• Participants are asked to fill out a satisfaction questionnaire.
• The course includes a visit to the SOCOMEC company site and photovoltaic installation.
SYDIV 011 a
Content
• Correct installation of the inverters and interconnection to the PV field and AC enclosure,
auxiliary service power supply.
• Installation, positioning of the technical compartment and inverter area.
• AC system component choice.
• Communication with the inverters: PV monitoring software.
• SUNGUARD supervision system (specifications, performance, options and modes of use).
Aimed at
• Designers, contractors and maintenance staff.
• Project leaders and managers.
Level required
• Basics of electronics and electrical systems.
• Participation in the Basic course.
Note
• Maximum number of participants: 6 people.
• Includes end-of-test course and certificate of attendance.
• Participants are asked to fill out a satisfaction questionnaire.
SYDIV 011 a
Content
• Presentation of latest updates of the SUNSYS H, SUNSYS B and SUNSYS P ranges.
• Sizing (e.g. related to product updates).
• Local and remote monitoring: specifications and choice of components.
• Product supervision.
• Correct installation of the inverters and interconnection to the PV field and AC enclosure,
auxiliary service power supply.
• Installation, positioning of the technical compartment and inverter area.
• Start-up of a demo inverter.
• Inverter maintenance.
Aimed at
• Designers, contractors and maintenance staff.
• Project leaders and managers.
Level required
• Basics of electronics and electrical systems.
• Participation in the Basic and Service course.
Note
• Maximum number of participants: 6 people.
• Includes end-of-test course and certificate of attendance.
• Participants are asked to fill out a satisfaction questionnaire.
SYDIV 014 a
Content
• Presentation of the SOCOMEC group.
• Presentation of the SUNSYS H, SUNSYS B and SUNSYS P ranges.
• Advantages of the SOCOMEC products and services offering.
• Product offers: ease of installation and flexible sizing.
• Competitive advantages: company structure, network proximity of customer service network.
• Reasons for choosing SOCOMEC:
- technical reasons,
- commercial reasons.
• SOCOMEC references.
Level required
• Basics of electronics and electrical systems.
• Participation in the Basic course.
Aimed at
• Area managers, sales reps, agents, pre-sales technical staff and general sales force.
Note
• Maximum number of participants: 15 people.
• Includes end-of-test course and certificate of attendance.
•P articipants are asked to fill out a satisfaction questionnaire.
• The course includes a visit to the SOCOMEC company site and photovoltaic installation.
Photovoltaic installations
General photovoltaic principles Photovoltaic generator protection
p. 86 Protection of a photovoltaic generator against
Photovoltaic architecture electrical discharges
p. 87 p. 93
Basics Protection of a photovoltaic generator against
p. 88 overvoltages
AC/DC galvanic isolation p. 93
p. 91 Overcurrents of a photovoltaic generator
p. 95
Photovoltaic generator isolation Protection of a photovoltaic generator against
Isolation overcurrents
p. 92 p. 97
Emergency opening Prevention against degradation of
photovoltaic systems
p. 92
p. 100
Fire-fighter isolation
p. 92
Photons
direct voltage'. Cell in low light
Q3 => I > Isc: in this case, the direct Cell in bright sunlight
“Forward” voltage
current (I) sent to the module is greater
Reverse voltage
N-doped
semiconducting
than the Isc current that it can generate, in
regions short circuit and according to the sunlight it
300 µm
is exposed to, as with a diode polarised 'in U OC
reverse voltage'. I SC
catec-pv 001 b gb
catec-pv 002 b gb
P-doped receiver generator
Q3 Q4
semiconducting regions
(silicon strip)
“Forward” current
Fig. 1.
600Wm² MPP
(Maximum
Power Point) 50 °C
400Wm² 25 °C
catec-pv 003 b gb
catec-pv 004 b gb
200Wm² 0 °C
Voltage Voltage
Photovoltaic architecture
Module and PV Chain (or PV string)
Placing the cells in series enables a module’s
available voltage to be increased, whereas 1 2 3
placing the cells in parallel increases its 3 x ISC
available current. 3I SC
UC
2I SC
UC 3 x UC
2
I SC
catec-pv 005 B
catec-pv 006 B
1 UC
I SC I SC I SC
Photovoltaic generator
A chain’s voltage is created when the modules
are placed in series. The coupling of chains of
catec-pv 007 B
catec-pv 009 B
Example: generator and a group of three 3-chain Example: generator and three groups of 3-chain
modules. modules.
catec-pv 012 a GB
catec-pv 014 a GB
• DC energy generation, with • DC/AC conversion, • Connection to the mains with:
photovoltaic panels, with inverters, - a metering device,
- and depending on power:
Connection
Production Conversion to mains interface systems
network with the mains,
• DC protection, with • AC protection, with transformation of low
catec-pv 013 a GB
catec-pv 011 a GB
Basics
Overall efficiency of the inverter
The inverter converts energy from the
modules into alternating energy.
Overall efficiency is caculated by multiplying MPP-Tracker Inverter
MPPT (Maximum Power Point Tracker)
P
efficiency and conversion efficiency. PMMP PDC DC PAC AC
network
AC
V
catec-pv 045 a GB
MPPT
1st function Calculation of inverter efficiency
The inverter ensures maximum power point Efficiency is one of the parameters that is electronics are around 2%.
tracking (MPPT). usually taken more into consideration in the Inverters with two-level technology and with
choice of an inverter. It is calculated by making conversion bridges derived from continuous
Punto di massima potenza the ratio between incoming power (DC) and power systems can also have losses of 6-7%.
PMPP= VMPP. IMPP
I (A)
outgoing power (AC).
P (W)
1.00 There are two main types of losses in
IMPP 0.40 an inverter: losses of changeover in the
0.75
0.30 conversion bridge and losses due to
0.50 dissipation in the electro-mechanical
0.20
components.
DC
0.25 0.10 Even though the losses in the copper, power AC
catec-pv 046 a iT
Basics (continued)
MPPT (continued)
2nd function EU efficiency
The inverter ensures maximum conversion One of the parameters that is mainly used to
100
efficiency. evaluate an inverter's validity is EU efficiency.
99
This is one of the few values that each
98
98.00 constructor is obliged to declare and is a
97
96.00 weighted average calculated by taking only 6
96
94.00 points of the efficiency curve: 5%, 10%, 20%,
92.00 95
30%, 50% and 90% of the nominal power.
catec-pv 051 a it
90.00 94
88.00 Each of these points is weighted in a different
93
86.00 way in this calculation: for example at 5% 10 20 30 40 50 60 70 80 90 100
catec-pv 047 a it
catec-pv 052 a it
92
Modular inverters are therefore penalised 91
90
by EU efficiency since equivalents with 10 20 30 40 50 60 70 80 90 100
centralised inverters have a lower annual
output for the same declared efficiency.
Euro
0.03 x 5% + 0.06 x 10% + 0.13 x 20% + 0.10 x 30% + 0.48 x 50% + 0.20 x 100%
Operation % Efficiency Efficiency Efficiency
5 90.28 0.03 2.708
10 94.40 0.06 5.664
20 96.27 0.13 12.515
30 96.77 0.10 9.677
50 96.87 0.48 46.497
100 96.04 0.20 19.208
96.270
Topology of converters
Three-level conversion bridge.
This innovative technology uses 6 IGBTs 500
(power breakers) per phase. 400
+ 400 V + 400 V
Instead of switching between the positive and 300
negative, as occurs in the more traditional 200
architecture, a virtual zero is generated with this 100
new conversion bridge: the positive half-wave 0
is generated by switching between zero and -100
higher whilst the negative half-wave is generated -200
by switching between zero and lower. + 400 V + 400 V 0V 0V
-300
Halving the voltage at the IGBT heads reduces -400
SUNSY 061 A
Basics (continued)
Type of inverters
Inverter with transformer
Inverter stage
Specifications
• Galvanic isolation
• Earth connection of the +/- poles
• Safety and immunity to interference 400 Vac 3ph
•C ompatibility with all types of modules
Specifications
• Efficiency
• Footprint
• Extended DC field
Adaptation stage DC/DC Inverter stage
Types of inverters
Systems with a centralised inverter Individual multi-inverter management Centralised multi-inverter management
These systems are characterised by the fact This type of architecture has the advantage This type of architecture allows greater
that a fault risks stopping all of production. of simplicity, thanks to the use of smaller flexibility in maintenance and management
This type of architecture is used for residential inverters compared to those that it would have of usage time of the machines by only using
applications with single-phase connection. been necessary to install by regrouping the the necessary number of inverters. This
From one to three strings in parallel, this generators in parallel. arrangement also ensures the use of inverters
configuration allows for the limitation of the at their optimum power depending on sunlight
DC protection function to the isolation system levels.
upstream of the inverter.
DC protection AC protection
catec-pv 015 B GB
Network
AC Connection to
protection mains network
catec-pv 016 B GB
AC Connection to
protection mains network
Production DC Conversion
protection
catec-pv 017 B GB
Conversion
Production DC
Multi-inverter systems protection
DC / AC galvanic separation
The choice of whether or not to implement The table hereafter shows all the possibilities: • AC side:
galvanic separation will determine the • DC side: - the selection of TT, TN or IT neutral systems
selection of protection and monitoring devices - the voltage class (VLV or LV),
on both the DC and AC circuits. - the installation, 'floating or insulated',
- direct functional polarisation or through a
resistor.
Direct current side (DC) Single unit diagram Alternate current side (AC)
Udc Protection against indirect contact Protection against indirect contact IT, TN or TT
120 V SELV Galvanic separation required to ensure SELV or PELV
catec-pv 018 a GB
TBTS
AC
section
protection.
Class II
AC
section
catec-pv 021 a gb
Class II
AC
section
Class II
AC
Galvanic separation compulsory because of DC polarisation.
section
catec-pv 022 a gb
Class II
AC
section
catec-pv 023 a gb
Disconnection
The purpose of disconnection is to ensure the This disconnection must fulfil the three
safety of operators by guaranteeing effective following functions:
separation from the source. This function
Function Characteristic Value
must be provided for both connections of the
Ensure air circuit breaking Impulse voltage (Uimp) 5 x Uoc
inverter(s) on the DC and AC circuits. If the distance
generator has several groups of chains, this
Guarantee the creepage Isolation voltage (Ui) 1.2 Uoc
function should also be provided so that each distance values
group can be individually operated. Provide foolproof indication Fully visualised breaking 3 F or
of the open position and visible breaking
ensure decommissioning
Inverter
length to consider is the sum of all the lengths.
AC
catec-pv 044 B gb
UTE C 15-712-1 guide, the installation - or when the keraunic level is > 25.
conditions for lightning arresters on DC and AC A second lightning arrester is necessary to L D
circuits depend on the following different criteria: protect the inverter if the distance between PV panels DC - AC LVSB
• On the DC circuit, a lightning arrester is the LV master panel (or the general control
compulsory for the inverter: and protection device) and the inverter
- either when there is a lightning conductor, D > 10 m.
- or when the length L between the PV
panels and the inverter is > crit. L. DC AC
A second lightning arrester is recommended PV panels - DC inverter AC inverter - LV master panel
to protect the PV panels if L > 10 m.
L < 10 m L > 10 m D < 10 m D > 10 m
• On the AC circuit a lightning arrester is
Installation with lightning conductor Non isolated - T1 T1 - T1 - T1 T2 - T1
compulsory for the LV master panel (or the
insulated - T2 T2 - T2 - T1 T2 - T1
general control and protection device):
Installation with no lightning conductor - T2 T2 - T2 - T2 T2 - T2
Note: T1 = type 1 or class 1 lightning arrester, T2 = type 2 or class 2 lightning arrester.
SITe 524 A
of an reverse voltage in the affected cell and
not to a significant increase in Isc current.
“Direct” voltage
“Partial shading”
operation
CATeC-PV 026 b Gb
receiver generator
Q3 Q4
Inverted voltage
CATeC-PV 027 b Gb
A Normal operation
Fig. 1.
B Shading present: overheating of the cell
C Protection by installing a Bypass diode
Inverted voltage
“Direct” voltage
“Inverted current”
Under normal conditions, the operating operation
CATeC-PV 029 A
receiver generator
Q3 Q4
dangerous overload for the module and the
UC0 ≈ UC1 -> IR ≈ ISC
DC installation. Inverted voltage
CATeC-PV 032 b Gb
Fig. 2.: double earth fault Fig. 3.: single earth fault on an installation with functional
polarisation
2
based on the following equation: 1 manufacturers of photovoltaic modules
1 2 3 4 5 6 7 8
(Ncmax - 1) IscSTC ≤ IRM < Ncmax IscSTC Number of photovoltaic chains in parallel
Certain manufacturers specify a max inverted
current more or less equal to the nominal short
Fig. 1.
circuit current and a significantly higher fuse
Protection devices against inverted current Note: generally, in an installation with no storage batte- rating.
ries, the IRM values of PV modules in crystalline silicon are
should be used for PV generators with a presumed to be between 2 and 3 IscSTC. Apparently, this low inverted current is
number of Nc chains above Ncmax. supposed to define defrosting currents or
currents to remove a fine layer of snow, the
fuse value therefore providing protection in fault
conditions.
When the manufacturer defines a max fuse
rating, this information must be taken into
consideration. However, should there be any
doubt over the exact fuse type, this should
be clarified with the manufacturer‘s customer
services department.
zone between the nominal current and the in order to avoid operating losses. Modules PV modules IRM
non-fusing current (Inf). In order to meet this requirement, a fuse with
This is particularly important for fuses a nominal current that is 40% higher than the
catec-pv 034 B gb
IRM; therefore, protection is ensured if the available should be checked against these Modules Iscr 2h performance
selected fuse operates correctly with the value coordination rules:
of 1.35 IRM. In ≤ 0.85 IRM for gR, gS or gG fuses ≥ 16 A
catec-pv 035 B gb
If ≤ 1.35 IRM or
etc.
Selection of the fuse for the ducting of the group of chains
(N: no. of chains)
DC circuit
catec-pv 037 a gb
Summary
Permissible currents of PV chain cables and selection of the associated protection devices.
Nc Number of chains Maximum inverted current Obligation of In Assigned current of the chain Iz Permissible current of the PV
on the generator of a chain Protection protection devices chain cables
1 - Iz ≥ 1.25 IscSTC
2 1.25 IscSTC No Iz ≥ 1.25 IscSTC
Nc ≤ Ncmax (Nc -1) 1.25 IscSTC Iz ≥ (Nc -1) 1.25 IscSTC
Nc > Ncmax In ≥ 1.4 IscSTC
(Nc -1) 1.25 IscSTC Iz ≥ I2
and In ≤IRM
Yes
Nc > Ncmax In ≥ 1.4 IscSTC Iz ≥ I2
(Nc -1) 1.25 IscSTC
and In ≤IRM – (Np -1) IscSTC
Double-pole protection
Regardless of the DC network, polarised or load from the upstream PV and safety
floating, protection against inverted currents disconnection (isolation distance, guaranteed
should be provided for both "+" and "-" creepage distances, certain or visible
poles. With functional polarisation that can disconnection, etc.).
be disconnected, the faulty currents can be In an installation that is accessible to persons
looped back by one or the other of the poles. other than authorised or experienced
Furthermore, it is strongly recommended to personnel, access to the fuse breaker,
pair these fuses with adapted fuse breakers lightning arrester and other devices that do
to ensure complete safety for the replacement not disconnect the installation should be
of fuses (IPxxb). connected to a switch that gives access to
This operation should be carried out off-load this equipment.
COFF 380 A
catec-pv 039 B gb
In the case of an extended generator IMD
to the network.
It is necessary to add to this device equipment
catec-pv 040 B gb
catec-pv 041 B gb
IMD DDR
that provides for daily measurement of the class B
isolation of the entire installation (generator
and inverter). This measurement is taken
when the inverter disconnection system on
the AC circuit is in the open position.
Note:
These provisions are provided in particular by the RCMU
device of the inverters in compliance with draft standard
VDE 0126-1.
catec-pv 043 B gb
the isolation for voltages Uoc x 1.2. R IMD
Glossary of common
photovoltaic terms
PV cell PV generator Maximum inverted current IRM
Fundamental PV device able to generate Assembly of PV generators, also called PV Maximum value of inverted current which a
electricity when it is exposed to light such as field. module can withstand without any damage.
sunlight. This value is supplied by the manufacturer.
PV conversion equipment Note 1: This value does not concern the current
PV module Device that transforms DC voltage into AC withstood by the diverting diodes, but the current going
through the PV cells in the inverted direction of the
The smallest component of interconnected voltage, also called an inverter. normal current.
solar cells completely protected against the Note 2: The typical value for crystalline silicon is
environment. Standard test conditions (STC) between 2 and 2.6 IscSTC of the module.
Test conditions prescribed in NF EN 60904-3
PV chain (C 57-323) for PV cells and modules. Maximum Power Point (MPP or MPPT)
Circuit where the PV modules are connected This principle, as indicated by its name
in series to form assemblies, in order to Open circuit voltage UocSTC (Maximum Power Point Tracker), makes it
generate the specified output voltage. Voltage in standardised test conditions, possible to track the maximum power point
at the terminals of a PV module, a PV of a non-linear electrical generator such as a
PV group chain, a non-charged PV group (open) or photovoltaic generator.
Integrated mechanical and electrical at the terminals of the DC circuit of the PV The MPPT or MPPTs also generally
assembly of chains and other components conversion equipment. represent a component of the inverter
to make up a DC electrical current allowing optimised use of solar radiation,
production unit. Short circuit current IscSTC by adapting its load to the characteristics
Short circuit current of a module, a chain, of the PV generator according to the actual
PV group junction box a PV group or a PV generator under sunlight.
Enclosure inside which all the PV chains of standardised test conditions.
all the PV groups are electrically connected
and where any protection devices can be
placed.
Regardless of the architecture of the photovoltaic installation, the type of modules used or the amount of
energy produced, SOCOMEC's innovative solutions are synonymous with high levels of efficiency and
reliability.
Below is a selection of customers who have chosen SOCOMEC for their photovoltaic projects.
Every company's environmental policy has resources and biodiversity, but also our the environment, especially in the reduction
an impact on the area in which it is located. human environment, and the health and of CO2 emissions and the optimisation
Every production process has an effect on safety of people. of energy consumption, having installed
applications
people, not only employees, but also those SOCOMEC supports the ethos of three different photovoltaic systems for the
who live in the surrounding area. eco-sustainability. production of most of the energy used in
Outdoor
Having a "Green Attitude" means From the outset, the company has been the Isola Vicentina factory.
respecting our environment, protecting involved in research into solutions which
what is most precious: air, water, natural minimise the impact of its own activities on
Roof installation:
• Power: 175 kWp.
• Inverters: 3x SUNSYS P33TR,
1x SUNSYS P66TR.
• Field boxes: 4x SUNSYS IFB.
• Remote monitoring system: SUNSYS
SUNGUARD.
•P anel technology:
- microamorphous,
- high-efficiency monocrystalline
back-contact,
BODY 283 B
- HIT monocrystalline,
- polycrystalline.
•P roduction: 195,500 kWh/year.
• CO2 emissions avoided: 110,000 kg/year.
Roof installation:
• Power: 30 kWp.
• Inverter with field box: 10x SUNSYS H30i.
• Remote monitoring system: SUNSYS
H30i wireless communication.
• Panel technology: polycrystalline.
•P roduction: 31,000 kWh/year.
• CO2 emissions avoided: 17,500 kg/year.
Installation on two-axle
BODY 382 A
trackers with two-axle
astronomical control
• Power: 14.5 kWp.
• Inverters: 1x SUNSYS B15.
• Field boxes: 1x SUNSYS IFB.
• Remote monitoring system: SUNSYS
SUNGUARD.
•P anel technology: HIT monocrystalline.
• Production: 17,000 kWh/year.
• CO2 emissions avoided: 9,500 kg/year.
BODY 336 A
Taglio di Po - Italy
Installation: solar park.
Power: 300 kWp.
Inverters: 3x SUNSYS P100TL.
Field boxes: 6x SUNSYS IFB.
Panel technology: polycrystalline.
Appli 436 a
site 583 A
Adria - Italy
Installation: on the roof.
Power: 240 kWp.
Inverters: 2x SUNSYS P100TL.
Field boxes: 4x SUNSYS IFB.
Panel technology: polycrystalline.
Appli 440 a
site 584 A
Ferrara - Italy
Installation: photovoltaic shelters.
Power: 2 MWp.
Inverters: 18x SUNSYS P100TL.
Panel technology: polycrystalline.
appli 441 A
Appli 437 a
Berlin - Germany
Installation: on the roof.
Power: 418 kWp.
Inverters: 1x SUNSYS P66TR,
3x SUNSYS P100TR.
Field boxes: 22x SUNSYS IFB.
Panel technology: CIS.
site 578 A
SITE 579 a
Strasbourg - France
Installation: on the roof.
Power: 900 kWp.
Inverters: 8x SUNSYS P100TL.
Field boxes: 16x SUNSYS IFB.
Panel technology: semi-transparent
monocrystalline.
appli 438a
site 580 A
Cornedo - Italy
Installation: on the roof.
Power: 5 kWp.
Inverter with field box:
2x SUNSYS H30i.
Panel technology: HIT monocrystalline.
appli 551 a
appli 552 a
Brescello - Italy
Installation: on the roof.
Power: 920 kWp.
Inverters: 8x SUNSYS P100TL.
Field boxes: 19x SUNSYS IFB.
Panel technology: polycrystalline.
APPLI 452 A
appli 444 a
appli 438a
site 580 A
Foggia - Italy
Installation: on the roof.
Power: 100 kWp.
Inverters: 2x SUNSYS P66TR.
Field boxes: 2x SUNSYS IFB.
Panel technology: polycrystalline.
APPLI 553 A
appli 554 a
Cernay - France
Installation: on the roof.
Power: 235 kWp.
Inverters: 3x SUNSYS P66TR,
1x SUNSYS P33TR.
Field boxes: 7x SUNSYS IFB.
Panel technology: polycrystalline.
APPLI 549 A
APPLI 550 A
SUNSYS P33TR
SUNSYS P66TR
SUNSYS P66TL
SUNSYS P100TR
SUNSYS P100TL
FJB ENCLOSURE
SUNSYS IFB
DIRIS
SUNSYS STORAGE
SUNSYS SHELTER
SIRCO PV
SIRCO MOT PV
SIRCOVER PV
To h e l p t o p r o t e c t t h e
environment, this document has
been printed on PEFC paper
(Programme for Endorsement of
Forest Certification).
www.socomec.com
DCG 126013 - 04 / 13