Term Contract for Condition Based Monitoring (CBM) Services (Mechanical) for Revision 1 PCFSSB Date 11/20/2020
M-39-01-B2 – Bearing Defects
1. Finding and analysis
Last Measurement POINT name POINT description Date/Time Last value Units Alarm status M1H Motor NDE Horizontal 11/20/2020 10:14 2.09 mm/s --- M1H ENV Motor NDE Envelope Acceleration 11/20/2020 10:18 3.641 gE Overall - Alert M1V Motor NDE Vertical 11/20/2020 10:15 1.353 mm/s --- M2H Motor DE Horizontal 11/20/2020 10:16 0.64 mm/s --- M2H ENV Motor DE Envelope Acceleration 11/20/2020 10:19 2.648 gE --- M2V Motor DE Vertical 11/20/2020 10:17 0.707 mm/s ---
- Velocity vibration level found to be acceptable according to ISO 10816-3 Group 2.
- Acceleration envelope level at the motor NDE bearing is within alert level based on the bearing bore size, with the appearance of non-synchronous frequency which is bearing fault frequency. - Although velocity vibration level is low, bearing fault frequency also present which based on rule thumb these bearing in the stage 3 from 4 stages of bearing defect.
2. Recommendation
- No immediate danger of failure is indicated but corrective action is recommended with 3
months.
3. Vibration Data.
Low level bearing frequency
appeared in the velocity spectrum ` VIBRATION MONITORING REPORT Page 2 of 4
Report No. M-39-01-B2
Term Contract for Condition Based Monitoring (CBM) Services (Mechanical) for Revision 1 PCFSSB Date 11/20/2020
Peaks of bearing fault frequency with
harmonics in the acceleration envelope reading
Low level bearing frequency
appeared in the velocity spectrum ` VIBRATION MONITORING REPORT Page 3 of 4
Report No. M-39-01-B2
Term Contract for Condition Based Monitoring (CBM) Services (Mechanical) for Revision 1 PCFSSB Date 11/20/2020
Low level bearing frequency
appeared in the velocity spectrum
Peaks of bearing fault frequency with
harmonics in the acceleration envelope reading ` VIBRATION MONITORING REPORT Page 4 of 4
Report No. M-39-01-B2
Term Contract for Condition Based Monitoring (CBM) Services (Mechanical) for Revision 1 PCFSSB Date 11/20/2020
Mikota J. (2000): Frequency tuning of a chain structure multi-body oscillator to place the natural frequencies at Omega1 and N-1 integer multiples Omega2 ... Omega N. GAMM 2000, Technical University of Göttingen, Germany.