You are on page 1of 3

OTDR

Test Result
Test Information
Filename DCD0655_Brownbuffer_f25.pdf
Model AE3100A S/N 3007463001
Date 2022.08.22(16:42:23) Calibration Date 2021.03.02
Firm. Version 1.04.32 Hard. Version 5.03
Corporation NOKIA Operator RDB

Cable Information
Cable ID 48c Fiber Number 25
Origin Loc. End Loc.
Direction A->B

Test Conditions
Wavelength 1550nm Distance Range 100m
Acq. Time 00:10 (mm::ss) Index 1.467000
Scatter Coefficient -81.87 Helix Factor 0.00%

Measurement
Fiber Length 0.09707km Total Loss 0.017dB
Average Loss 0.180dB/km Injection Level 22.69dB
Section ORL 54.793

Signature:___________ Date:________________
OTDR Test Result

Curve View
L
(dB) Fiber Length 0.09707km
R
Total Loss 0.017dB
66.7 Average Loss 0.180dB/km

53.3 0.000m
22.812dB

40.0 0.000m
22.812dB

26.7
1 2
13.3

0.00 85.15 170.30 << 100m

L Cursor 0.000m 22.812dB R Cursor 0.000m 22.812dB


L-R Distance 0.000m 0.000 L-R ORL. 0.000dB

Signature:___________ Date:________________
OTDR Test Result

Event List

Event Type Dis.(km) Loss(dB) Refl.(dB) Slp.(dB/km) T.Loss(dB)
001 0.00000 -.--- 0.000
0.09707 0.017 0.180 0.017
002 0.09707 0.017

Signature:___________ Date:________________