You are on page 1of 1

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Angle Steel Member Capacity Based on AISC 360-05

INPUT DATA & DESIGN SUMMARY


ANGLE SIZE L8X6X1
STEEL YIELD STRESS Fy = 36 ksi

AXIAL COMPRESSION FORCE P= 10 kips, ASD


STRONG GEOMETRIC AXIS EFFECTIVE LENGTH KLx = 20 ft
WEAK GEOMETRIC AXIS EFFECTIVE LENGTH KLy = 10 ft

STRONG GEOMETRIC AXIS BENDING MOMENT Mrx = 5 ft-kips, ASD


STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH Lbx = 20 ft, (AISC 360-05 F2.2.c)
STRONG DIRECTION SHEAR LOAD, ASD Vstrong = 77 kips

WEAK GEOMETRIC AXIS BENDING MOMENT Mry = 6 ft-kips, ASD


WEAK GEOMETRIC AXIS BENDING UNBRACED LENGTH Lby = 10 ft
WEAK DIRECTION SHEAR LOAD, ASD Vweak = 60 kips

THE DESIGN IS ADEQUATE.

ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

 P r 8  M r ,max M r ,min  P r  0.2


     , for
 Pc 9  M c,max M c ,min  Pc
  0.91 < 1.0 [Satisfactory]
 P r  M r ,max M r ,min  P r  0.2
    , for
2 P M M Pc
 c  c ,max c ,min 

Where Pc = Pn / Wc = 136 / 1.67 = 81.28 kips, (AISC 360-05 Chapter E5)


> Pr [Satisfactory]
Mr,max = 7.78 ft-kips or 0.71 ft-kips ,(major principal axis bending)
Mr,min = 0.71 ft-kips or 7.78 ft-kips ,(minor principal axis bending)
Mc,max = Mn / Wb = 42.24 / 1.67 = 25.29 ft-kips, (smaller equal-leg section used, AISC 360-05 Chapter F10-2)
> Mr,max [Satisfactory]
Mc,min = Mn / Wb = 15.89 / 1.67 = 9.51 ft-kips
> Mr,min [Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


Vn,strong / Wv = 172.8 / 1.67 = 103.5 kips > Vstrong = 77.0 kips [Satisfactory]

Vn,weak / Wv = 129.6 / 1.67 = 77.6 kips > Vweak = 60.0 kips [Satisfactory]