You are on page 1of 1

STAIRS MINIMUM OF TWO SETS MASONRY:

(21.2KN/m3) X (THICKNESS OF WALLS) X


(HEIGHT OF WALLS)

2nD AND 3RD FLOOR


1.8
(21.2KN/m3) X (0.20) X (3.5m) = 14.81KN/m
2
ROOF DECK
LANDING GIRDER
(21.2KN/m3) X (0.20) X (2m) = 8.48KN/m
350mm X 300mm
TILES: 0.77KPA
DIMENSION FOR GIRDERS AND FLOOR BEAMS.
2ND AND 3RD FLOOR
2ND - 3RD GIRDERS
CEILING ALLOWABLE: 1.2KPA
WIDTH- 300 mm
FLUID LOAD:
DEPTH- 450 mm
WATER TANK
FLOOR BEAMS
(9.81KN/m3) X (2m)
WIDTH- 300mm

DEPTH- 350mm
LIVE LOAD:
ROOF DECK GIRDERS
OFFICE: 2.4KPA
WIDTH- 350 mm
HALLWAY: 3.8KPA
DEPTH- 400 mm
ROOFDECK: 3.8 KPA
FLOOR BEAMS

WIDTH- 300 mm

DEPTH- 350 mm

THICKNESS OF SLAB - 200 mm

COLUMN: 300 x 300

THICKNESS OF STAIRS -150

COMPUTATION OF LOAD

DEAD LOAD

SELF -WEIGHT:

APPLY SELF-WEIGHT OF MEMBER AS PER STAAD