You are on page 1of 18

1

INPUT
BUILDING OF RCC SEGMENTAL BOX OF SIZE 1x1.2 m x1.8 m
2 m cushionAT BR.NO. …….
ASSUMPTIONS AND CONDITIONS
1) Loading 25 TonLoading
2)Grade of concrete of MIX 35 N/mm^2
3)Grade of steel ( Fy) 500 N/mm^3
4)Number of Track 1
5)Centre to Centre distamce of Track(if more than one track) 5.300 M.
6)Box is continuous along the barrel length YES
7)Angle of internal friction 30
8)Density of soil 18 KN/m^3
9)Leg of stirrup=1. if Main bar spacing,s<151,4xs
2. if Main bar spacing,s>151,2xs
REFERENCES
1) Bridge Rule 1989
2) Concrete Bridge Code(2nd Revised) 1997
3) Reiforced Concrete Designer's Handbook 1988
By Charles E. Reynolds & James C. Steedman
BASIC INPUT DATA
Whether the box is skew No
If skew then mention the skew angle, else angle=0 0.000 RADIAN
Barrel Length 6.850 M.
Whether the box is segmental YES
Whether the box is cast-in-situ No
Thickness of slab 0.350 M.
Thickness of wall 0.350 M.
Clear span of slab 1.200 M.
Clear height of wall 1.800 M.
Overall span of slab 1.900 M
Effective span of the slab 1.550 M
Overall depth of the RCC Box 2.500 M
Effective height of the wall 2.150 M
Live load for B.M.(Characteristic load) 403.000 KN.
Live load for S.F.(Characteristic load) 405.000 KN.
Rail level 100.000 M.
Bed level 97.280 M
Top of top slab level 97.280 M.
Formation level 99.280 M.
Bottom of top slab level 96.930 M.
Top of bottom slab level 95.130 M.
Bottom of bottom slab level 94.780 M.
Cover to steel 50.000 mm. 20.000 MM
CHECK FOR THICKNESS OF SLAB/WALL
Thickness provided 0.350 m
Minimum Thickness required 0.163 m
O.K.
NOTE-
MIN. DEPTH REQUIRED BY 2 M CUSHION IS LESS THAN 0 M CUSHION
SO THAT WE CAN SAY THAT 0 M CUSHION IS MORE CRITICAL THAN
2 M CUSHION.

638725595.xls
2

638725595.xls
3

CALCULATION OF CDA

CALCULATION OF CDA (IMPACT FACTOR)

Effective span of slab = Clear span + thickness of wall


1.20 0.35
1.55 m
Effective of Height of wall= Clear height + Thickness of wall
1.80 0.35
2.15 m
Bottom of sleeper level Rail level -0.4M.
99.60 m
Ballast cushion Bottom of sleeper - Formation level

0.32 m
Earth cushion Formation level - Top of top slab level

2.00 m

C.D.A.AT THE BOTTOM OF SLEEPER LEVEL


0.15+8/(6+L)
= 1.21
Since CDA is more than 1 , Hence CD 1.00

Total Cushion 2.32 m


CDA st top of box
Formula one (For Total Cushion<0.9) 0.5x (2- Depth of fill/0.9)x CDAs
Not Applicable

Formula two (For Total Cushion>0.9) 0.5x (3-(Depth of fill-0.9))x CDAs/3


0.26

DISPERSION LENGTH

I) Length of Sleeper + Total cushion + 5.84 m


+ Eff. Span/2
II) Segment length or Barrel Length 6.85 m
III) Centre to Centre of Track 5.30 m
IV) Length of sleeper+ Total cushion 5.07 m
Whichever is less
Hence Dispersion length = 5.07 m

Effective span = 1.55 m

NOTE-
DESPERSION LENGTH IN 2 M CUSHION IS MORE THAN 0 M CUSHION
SO THAT WE CAN SAY THAT 0 M CUSHION IS MORE CRITICAL THAN
2 M CUSHION.

REQUIRED AREA OF STEEL IN 2 M CUSHION IS LESS THAN 0 M CUSHION


SO THAT WE CAN SAY THAT 0 M CUSHION IS MORE CRITICAL THAN
2 M CUSHION.

638725595.xls
4

Check for Crack Width

ACR = 50
CNOM = 50
H = 350.000
ES = 200000
EC = 29580.398915
M = 6.7612340378
AST = 4018
d = 290
DC = 101.26496402
Ixx = 1313844145.2

TOTMOM = 27233966.285
STRESS = 26.45120996
STRAINST = 0.000132256
STRAINOUT1 = 0.000174301
MOMLIVE = 5439061.606
MOMPERM = 7240833.6391
bt = 1000
em -0.0004484829
=

-0.0004484829
Des.Crack width= -0.067272441

638725595.xls
5

LOAD CALCULATION
CALCULATION OF LOADS

Characteristic Live Load


Characteristic Live load for B.M. from Bridge rule 403.000 KN
Characteristic Live load for B.M. with CDA 509.123 KN
Design Live Load for B.M. with CDA per m. width(ULS) 129.701 KN/sq. m.

Characteristic Live load for S.F. from Bridge rule 405.000 KN


Characteristic Live load for S.F. with CDA 511.650 KN
Design Live Load for S.F. with CDA per m. width(ULS) 130.344 KN/sq. m.

Dead load
i)Slab weight = 8.750 KN/metre width
ii)Ballast weight= 6.080 KN/metre width
iii)Earth fill= 36.000 KN/metre width
iv)Track weight= 3.554 KN/metre width

Design Total dead wt on top slab/metre width= 76.137 KN/metre width

Design Wt of wall 26.338 KN/metre width


(effective ht. of wall x thikness of wall x 25 x factor 1.4)

Earth Pressure Calculation


137.000
Equilant ht of surcharge due to live load= -------------------- 1.431 m
(3+ total cushion)*18

28.800
Equilant ht of surcharge due to dead load= -------------------- 0.301 m
(3+ total cushion)*18

Tractive effort = 103.01 Kn

Tractive effort per m run 20.338 Kn/m

B.M. at the centre of top slab of the box 50.742339585 kn-m/m


B.M. at the centre of bottom slab of the box 94.468203356 kn-m/m

638725595.xls
6

CALCUALATION OF EARTH PRESSURE

Cha.Earth pressure at mid thickness of top slab 2x1/3x18x(eq.ht.of.surcharge(dead+live)+


due to (dead +live) Surcharge taking twice depth of fill+thk. of slab/2)
Design pressure (ULS) (*1.7) 86.219 KN/sq.m.

Cha.Earth pres. at mid thickness of bottom slab 2x1/3x18x(eq.ht.of.surcharge(dead+live)+


due to (dead +live) Surcharge taking twice depth of fill+thk. of slab/2+eff.Ht. Of wall)
Design pressure (ULS) (*1.7) 130.079 KN/sq.m.

earth pressure at top without live load 2x1/3x18x(eq.ht.of.surcharge(dead)+


surcharge depth of fill+thk. of slab/2)
Design pressure (ULS) (*1.7) 57.033 KN/sq.m.

earth pressure at bottom without live load 2x1/3x18x(eq.ht.of.surcharge(dead)+


surcharge depth of fill+thk. of slab/2 +eff.ht.of wall)

Design pressure (ULS) (*1.7) 100.893 KN/sq.m.

DESIGN FIXED END MOMENTS OF BOX CULVERT(ULS)

From Reiforced Concrete Designer's Handbook


By Charles E. Reynolds & James C.Steedman

constant(k) Eff.ht.of wall X (thk.slab)^3


Eff.span of slab X (thk.wall)^3

= 1.387
Moment from dead load

Mad=Mbd=Mcd=Mdd= UDLX(Eff.Span Slab)^2


12(K+1)

= -6.386 KN-M/Metre width

638725595.xls
7

FINAL END MOMENTS(ULS)

Moment from live load

Mal=Mbl=Mcl=Mdl= UDLX(Eff.Span Slab)^2


12(K+1)

= -10.878 KN-M/Metre width

Moment from Wt. of Wall

Maw=Mbw= Wt. of WallX(Eff.span of slab)K


6(K+1)(K+3)
Where K= constant

= 0.901 KN-M/Metre width

Mcw=Mdw= Wt. of WallX(Eff.span of slab)X(2XK+3)


6(K+1)(K+3)

= -3.751 KN-M/Metre width

Moment from Earth pressure with live load surcharge

Mael=Mbel= -P1xH^2xK(2xK+7) - P2xH^2 xK


60(K+1)(K+3) 12(K+1)

= -23.674 KN-M/Metre width

Mcel=Mdel= -P1H^2(3K+8)K _ P2H^2xK


60(K+1)(K+3) 12(K+1)

= -24.742 KN-M/Metre width

Where P1=Difference of EP with LL between


mid thickness of bottom and top slab
P2=EP with live load surcharge at mid
thickness of top slab
H = Effective Height of wall
K = Constant

638725595.xls
8

DESIGN LOAD COMBINATION(ULS)


Moment for Earth pr. without live load surcharge
Mae=Mbe= -P1xH^2xK(2xK+7) - P2xH^2 xK
60(K+1)(K+3) 12(K+1)

= -17.141 KN-M/Metre width

where P1=EP without live load surcharge at mid


thickness of top slab
P2=Difference of EP without LL between
mid thickness of bottom and top slab
H = Effective Height of wall
K = Constant

Mce=Mde= -P1H^2(3XK+8)K _ P2H^2xK


60(K+1)(K+3) 12(K+1)

= -18.209 KN-M/Metre width

DESIGN MOMENT FOR VARIOUS LOADING CONDITIONS(ULS)

Dead load Wall load Live load EP with L EP W/O


Surcharge Surch.

Condtion 1 DL+LL+EP(With LL surcharge) -6.386 0.901 -10.878 -23.674


Ma=Mb= -40.036 KN-M/Metre width
-6.386 -3.751 -10.878 -24.742
Mc=Md= -45.757 KN-M/Metre width

Condition 2 DL+LL+EP(Without LL surcharge) -6.386 0.901 -10.878 -17.141


Ma=Mb= -33.503 KN-M/Metre width
-6.386 -3.751 -10.878 -18.209
Mc=Md= -39.224 KN-M/Metre width

Condition 3 DL+EP(With live load surcharge) -6.386 0.901 -23.674


Ma=Mb= -29.158 KN-M/Metre width
-6.386 -3.751 -24.742
Mc=Md= -34.879 KN-M/Metre width

Condition 4 DL+EP(Without LL surcharge) -6.386 0.901 -17.141


Ma=Mb= -22.625 KN-M/Metre width
-6.386 -3.751 -18.209
Mc=Md= -28.346 KN-M/Metre width

Condition 5 DL+LL -6.386 0.901 -10.878


Ma=Mb= -16.363 KN-M/Metre width
-6.386 -3.751 -10.878
Mc=Md= -21.015 KN-M/Metre width

total moment (working) -45.757

638725595.xls
9

SAGGING BENDING MOMENTS


ABSUOLUTE MAXIMUM DESIGN HOGGING MOMENT(ULS)

Max. B.M. for Ma=Mb = 40.036 KN-M/Metre width

Max. B.M. for Mc=Md = 45.757 KN-M/Metre width

ANALYSIS FOR ABSOLUTE MAXIMUM DESIGN SAGGING B.Ms.(ULS)

I) FOR TOP SLAB

Condition 1 DL+LL+EP(With LL Surcharge)

Mab= (DL+LL)X(Eff.Span of slab)^2 FEM


8.000

= 21.779 KN-M/Metre width


Condition 2 DL+LL+EP(Without LL Surcharge)

Mab= (DL+LL)X(Eff.Span of slab)^2 FEM


8.000

= 28.312 KN-M/Metre width


Condition 3 DL+LL
Mab= (DL+LL)X(Eff.Span of slab)^2 FEM
8.000

= 45.453 KN-M/Metre width

ABSOLUTE MAXIMUM DESIGN SAGGING B.M. IN TOP SLAB(ULS)

Mab= 45.453 KN-M/Metre width

II) FOR BOTTOM SLAB

Condition 1 LL+Wall+DL+EP with live load surcharge

Mcd= (DL+WL+LL)X(Eff.Span of slab)^2 FEM


8.000

= 26.264 KN-M/Metre width

638725595.xls
10

CALCULATION OF SAGGING BENDING MOMENT


Condition 2 DL+LL+EP without live load surcharge

Mcd= (DL+WL+LL)X(Eff.Span of slab)^2 FEM


8.000
= 32.797 KN-M/Metre width

Condition 3 DL+LL
Mcd= (DL+WL+LL)X(Eff.Span of slab)^2 FEM
8.000
= 51.006 KN-M/Metre width

ABS. MAX. DESIGN SAGGING B.M. AT BOTTOM SLAB Mcd= 51.006 KN-M/Metre width

III) FOR WALL

Condition 1 DL+EP with LL Surcharge

Calculation of critical section for maximum B.M. (Y))


Where Y= Distance from the top of wall to be calculated
from the quardatic equation given below
AxY^2+BxY+C=0
Where A= 10.200
B= 86.219
C= -105.741
Y= 1.087

Macy= Reaction at top due EP With LL Surcharge x Y-


EP at top x Y^2/2- EP x Y^3/3 - FEM
Macy= 30.479 KN-M/Metre width

Condition 2 DL+ EP without LL Surcharge

Calculation of critical section for maximum B.M. (Y))


Where Y= Distance from the top of wall to be calculated
from the quardatic equation given below

AxY^2+BxY+C=0

Where A= 10.200
B= 57.033
C= -74.366
Y= 1.091
Macy= Reaction at top due EP With LL Surcharge x Y-
EP at top x Y^2/2- EP x Y^3/3 - FEM
Macy= 20.150 KN-M/Metre width

ABSOLUTE MAXIMUM DESIGN SAGGING B.M. ON WALL(ULS)


Macy= 30.479 KN-M/Metre width

638725595.xls
11

SHEAR FORCE CALCULATION

ANALYSIS FOR ABSOLUTE MAXIMUM DESIGN SHEAR FORCE(ULS)

I) 'FOR TOP SLAB


S.F.= (DL+LL)x(Eff.span of slab) + Net F.E.M.
2.000 Eff. Span

= 160.023 KN/metre width


II) FOR BOTTOM SLAB
S.F.= (DL+LL)x(Eff.span of slab) + Net FEM
2.000 Eff.Span

= 186.361 KN/metre width


III) FOR WALL AT TOP

Condition 1 DL+ EP with LL surcharge


S.F.= EP Rect.LoadxEff. ht. of wall/2 + EP Trian.load/3+
Net F.E.M/Eff.Span
= 105.741 KN/metre width

Condition 2 DL+EP without LL surcharge

S.F.= EP Rect.LoadxEff. ht. of wall/2 + EP Trian.load/3+


Net F.E.M./Eff.Span
= 74.366 KN/metre width

ABSOLUTE MAXIMUM DESIGN S.F. AT TOP OF WALL(ULS) 126.078

IV) FOR WALL AT BOTTOM

Condition 1 DL+ EP with LL surcharge

S.F.= EP Rect.LoadxEff. ht. of wall/2 + EP Trian.load/3+


Net F.E.M./Eff.Span
= 126.779 KN/metre width

Condition 2 DL+EP without LL wurcharge

S.F.= EP Rect.LoadxEff. ht. of wall/2 + EP Trian.load/3+


Net F.E.M./Eff.Span
= 95.405 KN/metre width

ABS. MAX. DESIGN S.F.AT BOTTOM OF WALL(ULS) 147.117 KN/metre width

638725595.xls
12

DEPTH

DESIGN OF SINGLE BOX

DESIGN CONSTANT

Grade of concrete - fck 35.000 N/Sq.mm


Grade of steel -fy 500.000 N/Sq.mm
Permissible Stress in steel fy= Type of steel ? N/Sq.mm
Permissible bending comp.stress fck= 35.000 N/Sq.mm

ABS. ABS.DESIGN MAXIMUM B.M.(ULS) 51.006 KN-M/metre width

DESIGN FOR BENDING MOMENT

Minimum effective depth required

deff. = ( Mulim/.138* b*fck ) ^ 0.5


103 mm
TOTAL DEPTH REQUIRED deff.+Cover+Half dia. of bar
163 mm
Assuming dia of bar =20 mms
Assuming clear cover =50 mms

TOTAL DEPTH ASSUMED 350 mm


TOTAL DEPTH TO BE PROVIDED 350 O.K.

Effective depth available 290 290 mm

638725595.xls
13

AREA OF STEEL REQUIRED


MAIN STEEL

Minimum area of steel required in slab 0.2% 700.0 sq.mm


Minimum area of steel in wall 0.2% 700.0 sq.mm

FOR HOGGING BENDING MOMENT

TOP SLAB AND WALL AT SUPPORT


Fck*b*d(1-sqrt(1-(5.06Mumax/Fck*b*d*d)))
2.2*Fy
35*1000*290*(1-sqrt(1-((5.06*40.04*10^6)/(35*1000*290^2))))/(2.2*500)
Minimum area of steel required = 323.2 sq.mm
Absolute minimum area of steel required = 700.0 sq.mm

Reinforcement provided are as follows

Bar type Diameter of bars Spacing of bars Area of r/f per m run
a-1 10.0 mm dia 200.0 mm c/c 392.7
a-2 10.0 mm dia 200.0 mm c/c 392.7
Total area of r/f per m run in mm2 785.4

For bottom slab and wall


Fck*b*d(1-sqrt(1-(5.06Mumax/Fck*b*d*d)))
2.2*Fy
35*1000*290*(1-sqrt(1-((5.06*45.76*10^6)/(35*1000*290^2))))/(2.2*500)
Minimum area of steel required = 370.3 sq.mm
Absolute minimum area of steel required = 700.0 sq.mm

Reinforcement provided are as follows

Bar type Diameter of bars Spacing of bars Area of r/f per m run
a-1 10.0 mm dia 200.0 mm c/c 392.7
c 10.0 mm dia 200.0 mm c/c 392.7
Total area of r/f per m run in mm2 785.4

FOR SAGGING BENDING MOMENT


For Top Slab
Fck*b*d(1-sqrt(1-(5.06Mumax/Fck*b*d*d)))
2.2*Fy
35*1000*290*(1-sqrt(1-((5.06*45.45*10^6)/(35*1000*290^2))))/(2.2*500)
Minimum area of steel required = 367.8 sq.mm
Absolute minimum area of steel required = 700.0 sq.mm

Reinforcement provided are as follows

Bar type Diameter of bars Spacing of bars Area of r/f per m run
b 12.0 mm dia 100.0 mm c/c 1131.0
0.0 mm dia 200.0 mm c/c 0.0
Total area of r/f per m run in mm2 1131.0

For bottom slab


35*1000*290*(1-sqrt(1-((5.06*51.01*10^6)/(35*1000*290^2))))/(2.2*500)
Fck*b*d(1-sqrt(1-(5.06Mumax/Fck*b*d*d)))
2.2*Fy

638725595.xls
14

Minimum area of steel required = 413.8 sq.mm


Absolute minimum area of steel required = 700.0 sq.mm

Reinforcement provided are as follows

Bar type Diameter of bars Spacing of bars Area of r/f per m run
d 12.0 mm dia 100.0 mm c/c 1131.0
0.0 mm dia 200.0 mm c/c 0.0
Total area of r/f per m run in mm2 1131.0

For Wall
35*1000*290*(1-sqrt(1-((5.06*30.48*10^6)/(35*1000*290^2))))/(2.2*500)
Fck*b*d(1-sqrt(1-(5.06Mumax/Fck*b*d*d)))
2.2*Fy
Minimum area of steel required = 245.0 sq.mm
Absolute minimum area of steel required = 700.0 sq.mm

Reinforcement provided are as follows

Bar type Diameter of bars Spacing of bars Area of r/f per m run
e 12.0 mm dia 100.0 mm c/c 1131.0
0.0 mm dia 200.0 mm c/c 0.0
Total area of r/f per m run in mm2 1131.0

Distribution steel

Minimum area of steel required in slab 0.12% 420.0 sq.mm


Minimum area of steel in wall 0.12% 420.0 sq.mm

Diameter of bars Spacing of bars required Spacing of bar provided


10 mm dia 186.99956271 mm c/c 150.0

638725595.xls
15

CALCULATION OF SHEAR REINFORCEMENT


Calculation of shear Reinforcement
Table from Concrete Bridge Code (As per Cl.6.17.1.1)

% of Steel = 0.20 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75
Per.shear stress(.25) 0.21 0.23 0.31 0.36 0.40 0.44 0.46 0.49 0.51 0.53 0.55 0.56
% of Steel = 0.20 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75
.Per shear stress(.30) 0.21 0.23 0.31 0.37 0.41 0.45 0.48 0.50 0.53 0.55 0.57 0.58
% of Steel = 0.20 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75
Per shear stress(35)= 0.21 0.23 0.31 0.37 0.42 0.40 0.49 0.52 0.54 0.56 0.58 0.60
% of Steel = 0.20 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75
Per. shear stress(40) 0.21 0.23 0.32 0.38 0.42 0.46 0.49 0.52 0.55 0.57 0.60 0.62

I) For Top slab


Max. Design Shear Force(ULS)= 160.02 KN
% steel(Ast.Supp.X100/100)= 0.27

For % steel 0.25 0.50 0.27


Permissible Shear Stress= 0.23 0.31 0.24
Hence Final Per. S. S.= 0.24 N/sq.mm
Unbalanced Shear Force= 91.39 KN

Spacing of Shear Reinforcement

Permissible shear stress vc Depth factor s svc


0.24 1.15 0.271191672133

Bar type Spacing of bars provided diameter diameter


Ast required
bothway required provided
g-1 200.00 183.91 7.72 10

For Bottom Slab


Max. Design Shear Force(ULS)= 186 KN
% steel (Ast. supx 100/dx100) = 0.27
% steel = 0.25 0.50 0.27
Permissible Shear Stress= 0.23 0.31 0.24
Hence Final Per. S. S.= 0.24 N/sq.mm
Unbalanced Shear Force= 117.73 KN

Spacing of Shear Reinforcement

Permissible shear stress vc Depth factor s svc


0.24 1.15 0.271191672133

Bar type Spacing of bars provided diameter diameter


Ast required
bothway required provided
g-2 200.00 183.91 7.72 10

For Wall Top

Max. Design Shear Force(ULS)= 126.08 KN


% steel (Ast. supportx 100/dx100) = 0.39
% steel = 0.25 0.50 0.39
638725595.xls
16

Hence Final Per. S.S.= 0.23 0.31 0.27


Hence Final Per. S. S.= 0.27 N/sq.mm
Unbalanced Shear Force= 46.39 KN

Spacing of Shear Reinforcement

Permissible shear stress vc Depth factor s svc


0.27 1.15 0.314887255301

Bar type Spacing of bars provided diameter diameter


Ast required
bothway required provided
g-3 200.00 183.91 7.72 10

For Wall Bottom

Max. Design Shear Force(ULS)= 147.12 KN


% steel (Ast. supportx 100/dx100) = 0.39
% steel = 0.25 0.50 0.39
Permissible Shear Stress= 0.23 0.31 0.27
Hence Final Per. S. S.= 0.27 N/sq.mm
Unbalanced Shear Force= 67.44 KN

Spacing of Shear Reinforcement

Permissible shear stress vc Depth factor s svc


0.27 1.15 0.314814758506

Bar type Spacing of bars provided diameter diameter


Ast required
bothway required provided
g-3 200.00 183.91 7.72 10

Haunch bars

Bar type Ast required diameter required spacing provided diameter provided Ast provided
f-1 & f-2 350 10.6526863128236 200 12 565.486677646

638725595.xls
17

3.00
0.57
3.00
0.60
3.00
0.62
3.00
0.63

638725595.xls
18

Ast provided
565.486677646

638725595.xls