DRAWINGS.
THE SAME.
ACCESSIBILITY CODE = FLORIDA BUILDING CODE 6th EDITION (2017) ACCESSIBILITY X B D
ENERGY CODE = FLORIDA BUILDING CODE 6th EDITION (2017) ENERGY CONSERVATION
WINDBORNE DEBRIS REGION:
METHOD OF DESIGN: N/A
DESIGNED PURSUANT TO RESIDENTIAL FLORIDA BUILDING CODES 2017 NO
CHAPTER 10, CHAPTER 3, ALTERATION LEVEL 2 AND CORRESPONDING
X YES
CHAPTERS 5,6,7 AND SECTION 1609 OF THE 2017 FBC.
Associates, Inc.
IMPACT RESISTANT GLAZING
J.R. ROST
RISK CATEGORY: N/A
I III 0.00 (OPEN)
X II IV X +0.18, -0.18 (ENCLOSED)
+0.55, -0.55, (PARTIALLY ENCLOSED)
BUILDING OCCUPANCY CLASSIFICATION:
GROUP A - ASSEMBLY GROUP H - HAZARDOUS
CLASSIFICATION OF WORK:
GROUP B - BUSINESS GROUP I - INSTITUTIONAL
ALTERATION
GROUP D - DAY CARE CENTER GROUP M - MERCANTILE
LEVEL 1
GROUP E - EDUCATIONAL X GROUP R - RESIDENTIAL
LEVEL 2
GROUP F - FACTORY INDUSTRIAL GROUP S - STORAGE
LEVEL 3
NOTE: X NEW CONSTRUCTION
.
CHANGE OF OCCUPANCY
.
ADDITION / REMODEL
Threshold Inspections
HISTORIC BUILDING
Design Loads:
email: devieseng@daystar.net
The structural system for this building has been designed in accordance with the Florida
Florida PE # 36486
Wind: Method of Design, per Section 1609 Florida Building Code 6th Edition (2017)
Brian L DeVries
Section 1609.6, Florida Building Code 6th Edition (2017);
Structural Design
f: 239-332-5322
p: 239-332-5022
Enclosed Design
Basic Wind Speed 160 MPH
RISK CATEGORY: II
Wind Exposure Category "B"
Internal Pressure Coefficient +/- 0.18 (for Enclosed)
Components and Cladding Design Pressures: Section 1609.6.3, Section 1609.6.4, &
Figure 1609.6.2 Florida Building Code 6th Edition (2017)
3D Front
1 Zone 1: 17.5 /-27.8 p.s.f. Zone 2: 17.5 /-58.7 p.s.f.
Zone 2(Overhang): -56.7 p.s.f. Zone 3: 17.5 /-58.7 p.s.f.
Zone 3(Overhang): -95.3 p.s.f. Zone 4: 30.4 /-33.0 p.s.f.
Zone 5: 30.4 /-40.7 p.s.f.
Structural Forces: Section 1606 & 1607 Florida Building Code 6th Edition (2017)
1341 Model
Gravity Roof Design:
Live load 20 PSF
Dead load 20 PSF
.
.
Live load 40 PSF
Dead load 10 PSF
NOTE: Structural Calculations using Gravity and Wind Loads have been performed in
the design of this structure.
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
Spec Home
# Revision Date
Drawn By jrr
Checked By ajq
8/9/2019 11:06:56 AM
A100
Cover Sheet
DRAWINGS.
THE SAME.
2
46' - 4"
Associates, Inc.
PH:(239)368-5900 * FAX:(239) 368-5125
5451 Lee Street Unit #2, Lehigh Acres, FL 33971
11' - 8" 11' - 8" 23' - 0"
J.R. ROST
(2) 2x12 GLUED & SCREWED
1' - 4"
1' - 4"
Covered Lanai
& SCREWED
6' - 0"
6' - 0"
FLAT CEILING
& SCREWED
8'-8" A.F.F.
4' - 8"
4' - 8"
6' - 3" 11' - 3" 12' - 0" 11' - 4" 5' - 6"
25 SH C D3 6068 SGD A
(2) 25 SH
A
(2) 25 SH
4' - 6"
2' - 0" 8' - 4" 2' - 8" 10' - 6" 10' - 10"
email: devieseng@daystar.net
2077 First Street, Suite 205
2' - 0" 6' - 8" 2' - 0"
7' - 0"
11' - 4"
Bedroom 2
Florida PE # 36486
Brian L DeVries
FLAT CEILING
Great Room Kitchen Master Suite
Structural Design
9'-4" A.F.F.
10' - 0"
f: 239-332-5322
p: 239-332-5022
COFFERED CEILING FLAT CEILING COFFERED CEILING
16' - 7"
10'-4" A.F.F. 9'-4" A.F.F. 9'-10" A.F.F.
7' - 8" 3' - 6"
19' - 4"
2' - 0"
24' - 3"
5068 1-CWS 1-CWS
2868
WBF
2' - 4"
A102 4
1-CWS 3' - 4" 4' - 10" 2' - 4" 3' - 8" 3' - 8" 3' - 6"
5' - 8"
5' - 8"
1-CWS
REF.
6' - 8"
2668
1-CWS
B 2868
WBF
2668
Dining Room
6' - 10"
1341 Model
Bath WBF
33' - 0"
1 A102
32 SH
5' - 4"
3068 OPENING
2868 PKT
5-CWS
1-CWS
3' - 2"
5-CWS
2' - 4"
1868
NOTE: 2668
WBF WBF M.Bath
PROVIDE 2"x4" BLOCKING AT 4'-0" O.C. AT THE DUCTS IN THE GARAGE AND DUCTS PENETRATING BE PROTECTED BY NOT LESS THAN 1/2 INCH (12.7MM) MIRROR FLAT CEILING
BOTTOM CHORD OF ALL TRUSSES IN LANAI AND THE WALLS OR CEILINGS SEPARATING THE GYPSUM BOARD OR EQUIVALENT. PER FBC 2017 6th EDITION 9'-4" A.F.F.
.
.
SECTION R309.2
53' - 0"
53' - 0"
ENTRY (AREAS EXPOSED TO WIND). CEILING DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED
2' - 4"
1-CWS 2' - 4" 5' - 0" 3' - 6"
SHEATHING IN THESE AREAS TO BE 5/8" EXTERIOR OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL PER SEC. R302.1 OF THE 2017 6th EDITION FLORIDA RESIDENTIAL 2868
2868
4' - 4"
8' - 10"
5-CWS
GRADE DRYWALL OR 1/2" EXTERIOR GRADE OR OTHER APPROVED MATERIAL AND SHALL HAVE BUILDING CODE, EXTERIOR WALLS SEPARATED BY LESS
W
5068
PLYWOOD. NO OPENINGS INTO THE GARAGE. THAN 6 FT., SHALL HAVE NOT LESS THAN 1 HR. FIRE 4068
WBF
MIRROR
RESISTIVE RATING WITH EXPOSURE ON BOTH SIDES. WBF
2868
6' - 8"
6' - 6"
OPENING FROM A PRIVATE GARAGE DIRECTLY INTO THE GARAGE SHALL BE SEPARATED FROM THE
A ROOM USED FOR SLEEPING PURPOSES SHALL NOT RESIDENCE AND ITS ATTIC AREA BY NOT LESS PER TABLE R702.3.5 (FOOTNOTE D) 7' - 8" 3' - 6" 5' - 4" 9' - 9" 6' - 3" 2' - 4" 10' - 10"
ON CEILING APPLICATIONS TO RECEIVE A WATER BASED
BE PERMITTED. OTHER OPENINGS BETWEEN THE THAN 1/2 INCH (12.7 MM) GYPSUM BOARD APPLIED Utility
23 SH
3' - 8"
TEXTURE MATERIAL, EITHER HAND OR SPRAY APPLIED, Den / Study
D
10' - 0"
16' - 5"
GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH TO THE GARAGE SIDE. GARAGE BENEATH HABITABLE
THE GYPSUM BOARD SHALL BE APPLIED PERPENDICULAR FLAT CEILING
SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES ROOMS SHALL BE SEPARATED FROM ALL HABITABLE FLAT CEILING 9'-4" A.F.F.
(35 MM) IN THICKNESS, SOLID OR HONEYCOMB CORE ROOMS ABOVE BY NOT LESS THAN 5/8 INCH (15.9 MM)
TO FRAMING. THE MINIMUM GYPSUM BOARD THICKNESS 9'-4" A.F.F. D
AUTO CLOSER
TYPE "X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SHALL BE 5/8 INCH FOR 24 INCH ON CENTER FRAMING
STEEL DOORS NOT LESS THAN 1 3/8 INCHES (35MM)
4"
OR 1/2 INCH SAG RESISTANT GYPSUM CEILING BOARD.
2668 SC W/
3068 SC
THICK, OR 20 MINUTE FIRE RATED DOORS. PER FBC SEPARATION IS A FLOOR CEILING ASSEMBLY, THE
Bedroom 3
11' - 0"
2017 6th EDITION SEC. R302.5.1 STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO THE DESIGN OF THIS PROJECT IS BASED ON ALL FLOORS ARE
ABOVE THE FEMA FLOOD EVEVATION, INCLUDING GARAGE. IF FLAT CEILING WH
3' - 0"
THIS PROJECT IS IN A FEMA FLOOD ELEVATION ALL LIVING 9'-4" A.F.F. D2
AREA FLOORS ARE 1 FOOT ABOVE BASE FLOOD ELEVATION. RECESSED A/H A/C
ALSO ALL ELECTRICAL, PLUMBING FIXTURES, MECHANICAL
EQUIPMENT & PADS SHALL BE 1 FOOT ABOVE BASE FLOOD Entry
ELEVATION FLAT CEILING
6' - 0"
12'-0" A.F.F.
& SCREWED
2868 x 1 3/4 SOLID CORE DOOR
3' - 8 1/2"
2' - 6" 2' - 6"
20 MINUTE FIRE RATING 1 3/8"
4' - 4"
4' - 10" 4' - 10"
160 MPH (3-SECOND GUST) MINIMUM THICKNESS
WINDOW SCHEDULE ENCLOSED STRUCTURE, WINDBORNE DEBRIS REGION
ACTUAL MANUF. MAX. (2) 2x12 GLUED
1' - 4"
APPLIED C 25 SH
7 1/2"
DESIGN INSTALLATION & SCREWED
WIND PRESSURES NOTES PRODUCT APPROVAL NOTES
PRESSURES (LIST BELOW) MASTER NUMBERS
MODEL OR
_ _ (WHERE APPLICABLE)
22' - 9"
KEY SIZE TYPE MANUFACTURER SERIES + +
5' - 11" 5' - 9" 5' - 0" 9' - 8"
20' - 6"
A (2) 25 SH PGT SH-200 26.40 -28.74 55.0 -58.2 1 FL239.1-R26, NOA# 17-0630.02 .
B 32 SH
Garage
PGT SH-200 26.40 -28.74 55.0 -90.0 . FL239.1-R26, NOA# 17-0630.02 . FLAT CEILING
8"x8" PT POST 9'-4" A.F.F.
C 25 SH PGT SH-200 27.66 -30.00 55.0 -58.2 1 FL239.1-R26, NOA# 17-0630.02 .
17' - 0"
19' - 4"
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
D 23 SH PGT SH-200 27.66 -30.00 55.0 -74.5 . FL239.1-R26, NOA# 17-0630.02 .
14' - 0"
12' - 8"
F
Spec Home
DOOR SCHEDULE
ACTUAL
D1 16070 GD RAYNOR
BuildMark / D1
TradeMark 23.52 -28.74 29.7 -33.1 3 FL14529.2-R8 .
D3 6068 SGD PGT SGD-670 24.72 -27.06 87.3 -87.3 . FL251.1-R31, NOA# 17-0420.09 .
10' - 0" 10' - 0"
D4
11' - 4" 5' - 8" 9' - 4" 20' - 0"
D5
46' - 4" 3
SHUTTERS Alum. storm panel Removable cold rolled sheet metal aluminum corrugated panels
RELIABLE
. SHUTTER CO. . FL10905-R3
retained by tracks or direct mounted to provide hurricane protection
SOFFIT SHALL COMPLY W/R703.1 OF THE 2017 FLORIDA BUILDING CODE 6th EDITION
ABBREVIATIONS
INSTALLATION NOTES: LEGEND: SIZE DESIGNATIONS
Strap# 11-45-26-06-00064.0080
1. MEANS OF EGRESS Dx = DOOR DESIGNATION W = WIDTH 3068 3'0" x 6'8" DOOR SIZE
SLx = SKYLITE DESIGNATION H = HEIGHT AFF ABOVE FINISH FLOOR Start Date August 6, 2019
2. TEMPERED WINDOW
AWN AWNING
3. O.H. GARAGE DOOR Wx = WINDOW DESIGNATION
CL CLEAR GLASS Drawn By jrr
4. EGRESS PER FBC 2017 6th EDITION CWS COATED WIRE SHELF
NOTE:SHGC COMPLIANCE ON WINDOWS - LESS THAN or EQUAL TO 0.25 U FACTOR COMPLIANCE FOR WINDOWS FD FRENCH DOOR Checked By ajq
NON-IMPACT - LESS THAN or EQUAL TO 0.65 FO FRAME OPENING SQUARE FOOTAGE ALLOWABLE SOIL LOAD:
IMPACT - LESS THAN or EQUAL TO 0.75 GL GLIDER
8/9/2019 11:06:59 AM
HDR HEADER Living Area 1338 SF THIS PROJECT IS DESIGNED ASSUMING AN ALLOWABLE
A101
OBS OBSCURE GLASS Garage Area 412 SF SOIL LOAD OF 2,000 PSF. THE CONTRACTOR SHALL
WBF WOOD BI-FOLD DOOR VERIFY AND OBTAIN A SOILS REPORT. IF CONDITIONS ARE
SGD SLIDING GLASS DOOR Covered Lanai Area 70 SF
FOUND TO BE DIFFERENT, CONTRACTOR SHALL NOTIFY
Entry Area 39 SF ENGINEER PRIOR TO ANY CONSTRUCTION.
TOTAL AREA 1859 SF
Floor Plan
-1' - 4"
1' - 4"
12' - 0"
Right Side
1/4" = 1'-0"
Top of Foundation
12' - 0"
1' - 4"
Entry Beam
Entry Beam
3
1' - 4"
Front Side
1/4" = 1'-0"
1' - 4"
5" / 1'-0"
1' - 4"
5" / 1'-0"
-1' - 4"
5" / 1'-0"
Top of Foundation
1' - 4"
4
2
1' - 4"
Left Side
Rear Side
0' - 0"
9' - 4"
1/4" = 1'-0"
1/4" = 1'-0"
1' - 4"
1' - 4"
Finished FL
Top of Beam
1' - 4"
5" / 1'-0"
1' - 4"
Finished FL
Top of Beam
0' - 0"
9' - 4"
5" / 1'-0"
1' - 4"
5" / 1'-0"
5" / 1'-0"
NOTE:
1' - 4"
SOFFIT SYSTEM.
VENTED AREA = 1859 SF
5" / 1'-0"
UPPER ROOF VENTS 40% TO 50% MAX, THE
1859 sf x .0033333 = 6.2 sf OF VENTS REQUIRED
1' - 4"
1' - 4"
Finished FL
Top of Beam
0' - 0"
9' - 4"
5" / 1'-0"
1' - 4"
Finished FL
Top of Beam
0' - 0"
9' - 4"
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
#
Spec Home
Start Date
Print Date:
Structural Design Threshold Inspections NOT ASSUME ANY RESPONSIBILITY FOR SUPERVISION OF CONSTRUCTION
OR REVIEW OF SHOP DRAWINGS. THE CONTRACTOR AND
Associates, Inc. SUB-CONTRACTORS SHALL STRICTLY ADHERE TO ALL BUILDING CODES
2077 First Street, Suite 205 AND AMENDMENTS BY LOCAL BUILDING DEPARTMENTS.
Building Elevations
. Fort Myers, Florida 33901 5451 Lee Street Unit #2, Lehigh Acres, FL 33971 THE MAXIMUM LIABILITY TO QUATTRONE & ASSOCIATES, INC. and J. R.
3405 41st Street SW p: 239-332-5022 PH:(239)368-5900 * FAX:(239) 368-5125 ROST ASSOCIATES, INC. SHALL NOT EXCEED THE FEE PAID TO QUATTRONE
& ASSOCIATES, INC. and J. R. ROST ASSOCIATES, INC., FOR THESE
jrr
DRAWINGS.
ajq
A102
f: 239-332-5322
Date
8/9/2019 11:07:11 AM
DRAWINGS.
THE SAME.
Associates, Inc.
PH:(239)368-5900 * FAX:(239) 368-5125
5451 Lee Street Unit #2, Lehigh Acres, FL 33971
SYMBOLS LEGEND
J.R. ROST
SYMBOL DESCRIPTION
110 VOLT OUTLET
G.F.I 110 VOLT GROUND FAULT INTERRUPTER
110 VOLT SPLIT WIRE OUTLET
220 VOLT OUTLET
WP
110 VOLT GROUND FAULT INTERRUPTER
@ 42" OFF FINISH FLOOR
3
SURFACE MOUNTED FIXTURE
email: devieseng@daystar.net
TV
Florida PE # 36486
TV
P
TV
CTR
Brian L DeVries
RECESSED MOUNTED FIXTURE
Structural Design
f: 239-332-5322
p: 239-332-5022
J JUNCTION BOX
S SMOKE DETECTOR & CO CENSOR
2
220v
P
TELEVISION OUTLET
TV
S
TELEPHONE JACK
CTR
PUSH BUTTON DOOR CHIME
DUEL HEAD FLOODLIGHT
REF.
S
EXHAUST FAN / LIGHT COMBO U.N.O.
1341 Model
S SINGLE POLE SWITCH
3
S THREE WAY SWITCH
3
GFI
CEILING FAN PREWIRE ONLY GFI
.
.
3
W
S
220v
CEILING FAN PREWIRE AND INSTALLED
D
(FAN FURNISHED BY OWNER)
GFI
3
220v
TV
WH
WP
WP
ELECTRIC
METER
NOTE: 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE 200 AMP
PANEL INDICATING TO THE HOMEOWNER THAT THE PANEL
ALL ROOMS WITH BRANCH CIRCUITS THAT
SUPPLY 125-VOLT, SINGLE PHASE, 15 AND 20 AIR HANDLER IS LOCATED IN THE ATTIC. SAID
AMPERE RECEPTACLE OUTLETS SHALL BE NOTICE SHALL BE IN ALL CAPITALS, IN 16 POINT
PROTECTED BY AND ARC-FAULT CIRCUIT TYPE, WITH THE TITLE AND FIRST PARAGRAPH IN
INTERRUPTER. BOLD:
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
EFFICIENT AND ECONOMIC OPERATION OF THE AIR
AREA AND INSTALLED IN ACCORDANCE WITH
CONDITIONING SYSTEM, YOU MUST ENSURE THAT REGULAR
CHAPTER 33 OF THE 2017 6th EDITION FLORIDA MECHANICAL
MAINTENANCE IS PERFORMED. YOUR AIR CONDITIONING
CODE.
SYSTEM IS EQUIPPED WITH ONE OR BOTH OF THE
AIR HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOLLOWING:
IF THE FOLLOWING CONDITIONS ARE MET: 1) A DEVICE THAT WILL ALERT YOU WHEN THE
Spec Home
CONDENSATION DRAIN IS NOT WORKING PROPERLY OR
# Revision Date
Drawn By jrr
Checked By ajq
8/9/2019 11:07:14 AM
E100
Electrical Plan
DRAWINGS.
THE SAME.
Termite protection shall be provided by registered termiticides or other approved 11' - 8" 11' - 8" 23' - 0"
methods of termite protection labeled for use as a preventative treatment to new
1' - 4" 9' - 0" 1' - 4"
construction. If soil treatment is used for subterranean termite prevention, in initial
chemical soil treatment inside the foundation perimeter shall be done after all 8" THKN'D EDGE W/(1)
excavation, backfilling and compaction is complete. Soil area disturbed after
Associates, Inc.
#5 CONTINUOUS
1' - 4"
including space boxes or formed. Space in concrete floors boxed out or formed for
subsequent installation of plumbing traps, drains or any other purpose shall be
created by using plastic or metal permanently placed forms of sufficient depth to
J.R. ROST
1" SLOPE O/A
eliminate any planned soil disturbance after initial chemical soil treatment.
6' - 0"
Chemically treated soil shall be protected with a minimum 6 mil vapor retarded to
4' - 8"
protect against rainfall dilution. If rainfall occurs before vapor retarder placement, 27' - 11" 18' - 5"
retreatment is required. Any work, including placement of reinforcing steel, done -0' - 4"
after chemical treatment until the concrete floor is poured, shall be done in such a
manner as to avoid penetrating or disturbing treated soil. Concrete over pour or
RECESS FOR TRACK
mortar accumulated along the exterior foundation perimeter, shall be removed prior
to exterior chemical soil treatment, to enhance vertical penetration of the chemical.
Chemical soil treatments shall also be applied under all exterior concrete or grade
within one foot (305mm) of the primary structure sidewalls. Also a vertical
6' - 11 1/2"
chemical barrier shall be applied promptly after construction is completed.
15' - 1"
pre construction soil treatment for protection against subterranean termites. A
email: devieseng@daystar.net
16' - 7"
certificate of compliance shall be issued to the building department by a licensed
Florida PE # 36486
20' - 4"
Brian L DeVries
termites. 26' - 4"
Structural Design
Treatment is in accordance with rules and laws established by the Florida
f: 239-332-5322
p: 239-332-5022
Department of Agriculture and consumer services.
24' - 3"
4" CONC. SLAB W/6x6 #10/10 W.W.M. or FIBERMESH
OVER 6 MILL VAPOR BARRIER ON WELL COMPACTED
Protective sleeves around metallic piping penetrating concrete slab-on-grade floors FILL (IN ACCORDANCE WITH FBC 2017, WHICH SAYS
shall not be of cellulose containing materials and shall receive application of a SOILS COMPACTED TO A MINIMUM OF 95% OF MODIFIED
PROCTOR IN ACCORDANCE WITH ASTM D 1557)
termiticide in annular space between sleeve and pipe. TREATED FOR TERMITES BEFORE POURING, BUT
REF.
AFTER PLUMBING ROUGH USING LIQUID PRETREAT
CONT74.
8' - 7" 11' - 2"
33' - 0"
3' - 4"
0' - 0"
1341 Model
NOTE TO MASON CONTRACTOR:
4' - 0"
1' - 7"
THE MASON CONTRACTOR IS RESPONSIBLE FOR
W
4' - 6"
VERIFYING ALL MASONRY OPENINGS WITH PROPER
MANUFACTURE'S SPEC. PRIOR TO CONSTRUCTION. 6' - 9"
47' - 0"
47' - 0"
.
.
16' - 5"
13' - 8"
-0' - 4" WH
16"x20" MONOLITHIC FT'G W/
3' - 0"
1" SLOPE O/A
(2) #5's CONTINUOUS
6' - 0"
16"x20" CONC. MONOLITHIC FT'G
2' - 6" 2' - 6" W/(2) #5 CONT. (TYPICAL FOR ALL
WALLS)
4' - 4"
4' - 10" 4' - 10" NOTE: UP TO 5 COURSE
STEMWALL MAY BE SUBSTITUTED
-0' - 4"
25' - 7 1/2"
26' - 2"
8" WOOD COL. W/ABU88 @
BASE
22' - 9"
22' - 8"
22' - 2"
5' - 11" 5' - 9" 5' - 0" 9' - 8"
8" THKN'D EDGE W/(1) 3'x3'x1'4" CONCRETE PAD
#5 CONTINUOUS FT'G W/(4) #5's E.W.
17' - 0"
14' - 0"
14' - 0"
FLOOR SURFACE SHALL BE OF APPROVED
NON-COMBUSTIBLE MATERIAL AND SHALL
BE SLOPED TO FACILITATE THE MOVEMENT
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
OF LIQUIDS TO DRAIN OR TOWARDS THE
MAIN VEHICLE DOORWAY IN ACCORDANCE
WITH FBC R 309.3
Spec Home
RECESS 3/4" FOR WATER STOP
46' - 4"
Foundation
1
1/4" = 1'-0"
Z:\Cadd file\Residential Files\2019 Jobs\NG5\Frame House\1341 Frame Model-rt.rvt
# Revision Date
Drawn By jrr
Checked By ajq
8/9/2019 11:07:15 AM
S100
THIS PROJECT IS DESIGNED ASSUMING AN ALLOWABLE
SOIL LOAD OF 2,000 PSF. THE CONTRACTOR SHALL
VERIFY AND OBTAIN A SOILS REPORT. IF CONDITIONS ARE
FOUND TO BE DIFFERENT, CONTRACTOR SHALL NOTIFY
ENGINEER PRIOR TO ANY CONSTRUCTION.
Foundation Plan
A
as the reinforcement, minus 2 times the 3" minimum cover. B. Studs Size 2" to 4" Thick x 2" to 6" wide; #2 dense or better. 6"O.C. @ EDGES & INTERMEDIATE FIELD
C. Structural Joist and Planks size 2" to 4" thick x 5" to 8" wide; #2 or better: 9" AREA.
TYPICAL GABLE
3. All details and sections shown on the drawings are intended to be typical and shall be
DRAWINGS.
THE SAME.
TYPICAL HIP
to 12" wide: #1 or better. 3 2
A
constructed to apply to any similar situation elsewhere in the work except where a different 5. All horizontal reinforcement bars shall be evenly spaced within the pad minus the 3" cover SHEAR CAPACITY 240 PLF.
detail is shown. on each side. D. Light Framing Size 2" to 4" thick x 3" to 4" wide; #2 non-dense or better. A
E. Alternate partition wall framing construction; SPF or Hem-Fir Stud, Non-bearing. 2 1 ZONE 3 = PROVIDE 8D RING SHANK NAILS @
4. Subsurface soil condition information is not available. Foundations are designed for a soil 6. All horizontal reinforcement bars shall be located at the depth specified in plan. 4"O.C. @ EDGES & INTERMEDIATE FIELD
4. Structural Wood Panels (Sheathing) shall be specified by thickness, grade, APA Span 3 2
A
bearing capacity of 2,000 PSF. The contractor shall report any differing conditions to the AREA.
designer prior to commencing work. 7. All vertical bars that terminate within the pad perimeter shall have (1) 90-degree hook of Rating, and Exposure Durability Classification as shown on the drawings. Nail as specified
A
SHEAR CAPACITY 240 PLF. PROVIDE 2"X 4"
Associates, Inc.
equal bar size as the vertical from above for each vertical reinforcing bar. per detail or note.
A
depressions, and other details not shown on Structural Drawings. to the vertical steel. be pressure treated. Clearance between wood siding and earth on the exterior of a building EDGES OF SHEATHING. ATTACH BLOCKING TO
shall be not less than 6 inches except where siding, sheathing and wall framing are of 2 1 2 TRUSSES W/ MIN. (3) 12d TOENAILED @
6. All bolts, nuts, washers, straps, and fasteners including nails, shall be Hot-dip Galvanized 9. All lap splices shall be a minimum of 30 (18.75" for # 5 bar) bar diameters in concrete approved pressure treated wood. A EACH END.
J.R. ROST
or Stainless Steel. Continuous anchorage shall be provided between all trusses, wall sections, and 48 (30" for # 5 bar) bar diameters in masonry or 12" whichever is greater.
beams, posts, and footings with the use of straps and connectors as specified herein, except 6. Contractor shall provide all fastening devices as shown on the drawings and as necessary
for interior framing. 10. All 90 degree hooks shall have a minimum of a 12 bar diameters (8" for # 5 bar) and suited for each application. Fastening subject to moisture shall be Hot-Dip Galvanized
extension. to ASTM A-153-80, or Stainless Steel.
3 2 3
A
7. All specified fasteners may be substituted with equivalent fasteners. The
installation of the fasteners shall be in accordance with the manufacturer's specifications. 11. All hook extensions shall be located in the horizontal plane at 3" plus 1/2" bar diameter 7. All metal connections and fabrications shall comply with AISC Specifications.
from the center of the extension to the bottom edge of the concrete pad to the centerline
8. Wind bracing (1st and 2nd floors) with 18 gauge X 1-1/4" galvanized straps 10'-0" long of the reinforcement. 8. Solid block all joists and rafters at interior points of support.
placed diagonally, all bearing walls at corners or with 4'-0" X 10'-0" or 8'-0" X 5/8"
exterior grade plywood siding. 12. All hook extensions shall be run in the horizontal plane away from the center of the pad 9. Prefabricated structural trusses shall comply with NFPA, National Specifications for Wood
ROOF SHEATHING NAILING SPECIFICATIONS
when the center of the vertical of the hook extension is within 5" from the center of the Construction, TPI Design Specifications for Metal-Plated Wood Trusses and AITC 100. SCALE N.T.S.
9. The structure is designed to be self-supporting and stable after the building is complete. pad.
It is the contractor's sole responsibility to determine erection procedures and sequence to 10. All trusses shall be designed and certified by the Truss Manufacturer's State of Florida 2x4 SPF CONST. @ 24" O.C.
ensure safety of the building and its components during erection. This includes the addition 13. All hook extensions shall be run in the horizontal plane toward the center of the pad Registered Engineer. CONT. OVER (4) TRUSSES ON
of necessary shoring, sheeting, temporary bracing, guys or tie downs. when the center of the vertical of the hook extension is not within 5" from the center of TOP OF BOTTOM CHORD NAILED
email: devieseng@daystar.net
14. Brace trusses during erection and after permanent installation to comply with TPI BWT-76 BOTTOM CHORD OF TRUSS
Florida PE # 36486
plans and installed in accordance with Manufacturer's recommendations. Any edges or ends IS 2x6 OR GREATER, MATCH FRAME WALL
Brian L DeVries
the 3" cover on each side. BLOCKING.
4. Footings shall bear upon undisturbed treated soil or upon soil compacted to at least 95% exposed to the weather shall be protected by the installation of 26 Ga. Minimum, Galvanized
Structural Design
Steel Flashing.
f: 239-332-5322
p: 239-332-5022
of Standard Proctor Maximum Dry Density (ASTM D1557) for a depth of at least three (3) 6. All horizontal reinforcement bars shall have a minimum horizontal spacing within the footer
feet below the bottom of the footing. of (1) horizontal bar diameter or 1" whichever is greater.
16. Splices in multi-board continuous beams shall be allowed for one board only per span
5. Reinforcing steel shall be ASTM A-615 Grade 60 Deformed Steel. All continuous vertical and only at the quarter point of the span, unless shown otherwise.
7. All horizontal reinforcement bars shall be located at the depth specified in plan.
and horizontal reinforcing steel in footings, beams, and columns shall be lap spliced a
minimum of 30 Bar Diameter or 12", whichever is greater. 17. Double top plates shall be overlapped at corners and secured with 4-10d nails.
8. All vertical reinforcement that terminates within the footer shall have (1) 90-degree hook
Mid-wall splices shall be 48" minimum w/ (2) rows of 10d nails at 4" O.C., staggered.
6. All 90 degree hooks with side cover (perpendicular to plane of hook) not less than 2.5
of equal bar size as the vertical from above for each vertical reinforcing bar.
Masonry Notes: FRAME WALL PARALLEL TO TRUSS
inches, and cover on bar extension beyond hook (also called end cover) not less than 2 9. All 90-degree hooks shall either be bent into the end of the vertical steel or lap spliced SCALE N.T.S.
inches: shall be embedded in support member a minimum of 15.5 Bar Diameters: and the to the vertical steel. 1. Concrete masonry units shall be ASTM C90-75, Hollow Load Bearing concrete masonry
hook shall be extended at least 12 Bar Diameters at the free end of the bar within the units, Type I, Grade N-1, normal weight, with a minimum net area compressive strength =
support member. 10. All lap splices shall be a minimum of 30 (18.75" for # 5 bar) bar diameters in 1900 psi.
*All 90 degree hooks with side cover (perpendicular to plane of hook) less than 2.5 concrete and 48 (30" for # 5 bar) bar diameters in masonry or 12" whichever is greater.
inches, and cover on bar extension beyond hook (also called end cover) less than 2 inches: 2. Concrete masonry units shall be laid in running bond pattern with minimum of face shell
shall be embedded in support member a minimum of 22 Bar Diameters: and the hook shall 11. All 90 degree hooks shall have a minimum of a 12 bar diameters (8" for # 5 bar) bedding.
be extended at least 12 Bar Diameters at the free end of the bar within the support extension.
member. 3. Mortar shall conform to ASTM C270 and be Type M or S. ASPHALT SHINGLES ON 30# FELT, OVER 15/32"
PLYWOOD ATTACHED TO TRUSSES W/8d RING
1341 Model
12. All hook extensions shall be located in the horizontal plane at 3" plus 1/2" bar diameter
7. Concrete cover and spacing of reinforcing steel shall be as follows from the center of the extension to the bottom edge of the concrete footer to the centerline 4. Unless noted otherwise, the following minimum horizontal masonry joint reinforcement shall SHANK NAILS @ 4" O/C PANEL EDGES AND 6" O/C
A. Footings: 3" Bottoms and Sides, 2" Top of the reinforcement. be provided (Use Truss-type with 6" lap at all splices): PANEL INTERIOR. 12
B. Beams: 1-1/2" Bottom, Sides and Top
C. Columns: 1-1/2" 13. All hook extensions shall be run parallel to the horizontal steel in the footer. A. No horizontal masonry joint reinforcement shall be provided above the finished 5 ROOF PITCH
D. Slabs on Grade: 2" Bottom, 1" Top floor, if the masonry wall has a bearing height less than 10' A. F. F.
E. Rebar C. to C.: 1 Bar Diameter or 1", whichever is greater ASPHALT SHINGLES ON 30# FELT, OVER 15/32"
14. All stem walls shall have a #5 bar vertical in a grout filled cell @ 48" o.c., @ both PLYWOOD ATTACHED TO TRUSSES W/8d RING
(Center to Center spacing of rebar within concrete.) sides of every opening, @ every corner, and @ every reinforced vertical cell extending up to B. Horizontal masonry joint reinforcement shall be provided above the finished floor INSTALL (1) SIMPSON MTS16, or USP MTW16 @
F. Others: Per ACI at 24" o.c., starting and ending 8" above the finished floor and below the SHANK NAILS @ 4" O/C PANEL EDGES AND 6" O/C EACH TRUSS TYPICAL - REFER TO TRUSS
the tie beam. PANEL INTERIOR. 12
tie-beam, if the masonry wall has a bearing height equal to or greater than 10'
.
.
CONNECTOR SCHEDULE ON SHEET S102 FOR
8. Welded wire fabric shall conform to ASTM A-185, free from oil, scale, and rust and 15. All stem walls shall have horizontal masonry joint reinforcement provided above the footer and less than 12' A. F. F. ADDITIONAL REQUIREMENTS
5 ROOF PITCH
placed in accordance with the typical place details of ACI Standards and Specifications. at 16" o.c., starting and ending 8" above the footer and below the finished floor. Use
Minimum lap shall be one space plus two (2) inches. Truss-type with 6" lap at all splices. C. Horizontal masonry joint reinforcement shall be provided above the finished floor
at 16" o.c., starting and ending 8" above the finished floor and below the
Concrete Mono Footer Notes: tie-beam, if the masonry wall has a bearing height equal to or greater than 12' INSTALL (1) SIMPSON MTS16, or USP MTW16 @
16. When specified by footing detail, slabs under vertical reinforced masonry walls shall have EACH TRUSS TYPICAL - REFER TO TRUSS
a #4 bar with a 90 degree hook, extending 30" into slab @ a depth of 2" below slab and less than 16' A. F. F.
1. These notes and specifications apply to all concrete mono footers unless noted otherwise CONNECTOR SCHEDULE ON SHEET S102 FOR
surface & extending 6" vertically down the stem wall @ 3" clear distance from exterior edge ADDITIONAL REQUIREMENTS R-30 INSULATION
of stemwall or @ the center line of an interior stem wall. Provide these hooks @ every D. Horizontal masonry joint reinforcement shall be provided above the finished floor
2. See Concrete Notes for the concrete, and steel strengths and specifications. at 8" o.c., starting and ending 8" above the finished floor and below the METAL DRIP EDGE
reinforced vertical cell extending up to the tie beam (except where noted otherwise) and
within wall opening @ 48" o.c. from vertical at each end of wall opening. tie-beam, if the masonry wall has a bearing height equal to or greater than 16
3. All reinforcement shall have a minimum of 3" cover on all sides A. F. F.
5/8" DRYWALL CEILING or
4. All horizontal reinforcement shall be continuous. 17. When specified by footing detail slabs under bearing frame walls shall have a #4 bar
5. Masonry: Minimum compressive strength F'm=1,500 psi 1/2" SAG RESISTANT
with a 90 degree hook extending 30" into slab @ a depth of 2" below slab surface, 2x6 SUB-FASCIA
5. All horizontal reinforcement bars shall be evenly spaced horizontally within the footer minus extending 6" vertically down the stem wall @ 3" clear distance from exterior edge of stem W/ALUMINUM COVERING
wall or @ the center line of an interior stem wall. Provide these hooks @ 48" o.c under 6. Grout shall be Pea Rock (3/8" Maximum Diameter Aggregate) Concrete mix with F'c=3000
the 3" cover on each side. METAL DRIP EDGE R-30 INSULATION
frame, @ every post location, and within wall opening @ 48" o.c. from post hook at each psi and having a slump between 8" and 11" at the time of placement.
6. All horizontal reinforcement bars shall have a minimum horizontal spacing within the footer end of wall opening. DOUBLE 2x_ TOP PLATE -
7. Reinforcing steel shall be ASTM A-615 Grade 60 Deformed Steel. 5/8" DRYWALL CEILING or
of (1) horizontal bar diameter or 1" whichever is greater. Grout Filled Masonry Column Notes: REFER TO TYPICAL BEARING
1/2" SAG RESISTANT ALUMINUM SOFFIT - TO
8. Minimum lap splice shall be 48 Bar Diameter or 12" whichever is greater. WALL FRAMING DETAIL ON
1. These notes and specifications apply to all Grout Filled Masonry Columns unless noted 2x6 SUB-FASCIA COMPLY WITH SECTION
7. All horizontal reinforcement bars shall be located at the depth specified in plan STRUCTURAL DETAIL SHEET.
otherwise: W/ALUMINUM COVERING R703.1 OF 2017 FBC 6th
Exposed Ceiling Notes:
EDITION
8. All vertical reinforcement that terminates within the footer shall have (1) 90-degree hook
of equal bar size as the vertical from above for each vertical reinforcing bar 2. See the Masonry Notes for the masonry, grout, and steel strengths and specifications. All exposed ceilings in Entry's, Porches and Lanais shall be of one of the following types:
DOUBLE 2x_ TOP PLATE -
Substitution ceiling type is allowed.
3. All reinforcement shall have a minimum cover of 1/2" between the interior surface of the REFER TO TYPICAL BEARING
9. All 90-degree hooks shall either be bent into the end of the vertical steel or lap spliced ALUMINUM SOFFIT - TO
C.M.U. cell and all sides of the reinforcement. WALL FRAMING DETAIL ON
to the vertical steel. 1. 1/2" plywood or OSB sheathing fastened directly to trusses or framing. COMPLY WITH SECTION
STRUCTURAL DETAIL SHEET. REFER TO HEADER
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
top of the footing or slab in any story, and shall be located vertically not more than ¢ a DRYWALL AND TEXTURED
INSTALL WINDOW AS PER
14. When specified by footing detail, slabs under vertical reinforced masonry walls shall have lateral tie spacing below the lowest horizontal reinforcement in the beam, girder, slab, or AS PER CONTRACT
FLOOR PLAN & SCHEDULE
a #4 bar with a 90 degree hook, extending 30" into slab @ a depth of 2" below slab drop panel.
surface & extending 6" vertically down the mono footer @ 3" clear distance from exterior
edge of mono footer or @ the center line of an interior footing. Provide these hooks @ 8. All vertical bars shall terminate at both ends with (1) 90-degree hook of equal bar size R-13 MIN. INSULATION
every reinforced vertical cell extending up to the tie beam (except where noted otherwise) as the vertical. COVERED WITH 1/2"
and within wall opening @ 48" o.c. from vertical at each end of wall opening DRYWALL AND TEXTURED
9. All 90-degree hooks shall either be bent into the end of the vertical steel or lap spliced INSTALL WINDOW AS PER
AS PER CONTRACT
Spec Home
15. When specified by footing detail slabs under bearing frame walls shall have a #4 bar to the vertical steel. FLOOR PLAN & SCHEDULE
with a 90 degree hook extending 30" into slab @ a depth of 2" below slab surface, 2x_ STUDS @ 16" O/C AND
PANEL INTERIOR COVERED WOOD BASE AS PER (1) VERTICAL #5 @ 4'-0" O/C
beam without violating the cover requirements.
W/TYVEK or FELT. OWNER'S CONTRACT MAX. AND @ ALL CORNERS &
7. Horizontal steel over masonry walls shall be spliced in a vertical plane OPENINGS.
4" CONCRETE SLAB - REFER TO
SHEET S100 FOR SPECIFICATIONS
8. Horizontal steel over openings shall be spliced in a horizontal plane within 1/3 of the FINISHED GRADE # Revision Date
beams span from the supports.
Typical Monolithic Wood Wall Section Typical Wood Wall on Stem Wall
8/9/2019 11:07:15 AM
1 2
3/4" = 1'-0" 3/4" = 1'-0"
S101
Structural Notes & Details
DRAWINGS.
THE SAME.
OPENING SIZE KING STUDS HEADER STUDS
O TO 3'-4" (2)-2X6 S.P.F. W/ 1/2" PLYWOOD (1) EA. SIDE (1) EA. SIDE
HEADER BEAM @ TOP OF
3'-4" TO 8'-0" (2)-2X8 S.P.F. W/ 1/2" PLYWOOD (1) EA. SIDE (1) EA. SIDE WALL BELOW DBL. TOP PLATE. CONTINUOUS DBL. 2X- TOP PLATE. NAIL
8'-0" TO 10'-0" (2)-2X10 S.Y.P. NO. 2 W/ 1/2" PLYWOOD (1) EA. SIDE (2) EA. SIDE LOWER PLATE TO STUDS W/2-16d FOR
10'-0" TO 12'-0" (2)-2X12 S.Y.P. NO. 2 W/ 1/2" PLYWOOD (1) EA. SIDE (2) EA. SIDE 2X4 FRAMING & 3-16d FOR 2X6 &
Associates, Inc.
LARGER. NAIL UPPER PLATE TO LOWER
J.R. ROST
2. ALL HEADER BEAMS SHALL BE BUILT UP WITH 1/2" PLYWOOD FILLER. NAILING SHALL BE NAIL TO KING
STUDS W/16d @ TYP. 2X- STUDS @ 16" O.C.
12d NAILS @ 16" O.C. ALONG EACH EDGE. SPLICES, IF NECESSARY, SHALL BE LOCATED @
1/4 THE LENGTH OF THE BEAM BETWEEN SUPPORTS. 16" O.C.
5" / 1'-0"
16" MAX. FOR 2X6 & LARGER FRAMING.
"T" BRACE SCHEDULE
MAX. HGT.
2X- "T" BRACE CONNECTION "B" 5/8" J-BOLT OR REDHEADS (TYP.)
COMMON WOOD ROOF GABLE HEIGHT BRACE
DROP GABLE END SPH- EA. STUD @ 18" W/ 3" X 3" X 1/8" WASHER
TRUSSES @ 24" O/C O TO 6'-0" NOT REQUIRED MIN. END & SPLICE DISTANCE = 6"
MTS 18 @ 24" O/C
email: devieseng@daystar.net
6'-0" TO 9'-0" 2X4
2x6 PT ATTACHED TO
Florida PE # 36486
GYPSUM WALL BOARD 1. BEARING WALL DESIGNED FOR A GRAVITY LOAD OF 1500#/TRUSS SPANS UP TO 7'-6" (2)LSTA 18 EA. SIDE
Brian L DeVries
END NAIL BOTT. CHORD AND AN UPLIFT LOAD OF 1000"/TRUSS. SPANS UP TO 10'-6" (2)LSTA 24 EA. SIDE
NOTE:
Structural Design
W/ 16d @ 8" O/C
f: 239-332-5322
p: 239-332-5022
1. ATTACH ROOF SHEATHING @ 2. REFER TO FLOOR PLAN FOR FRAMING MATERIAL, SIZE & SPACING. SPANS UP TO 12'-6" (2)LSTA 30 EA. SIDE
DROP GABLE W/ 8d RING SHANK @ 4" O/C
2. ALL OTHER TYPICAL FRAMING 3. FASTEN 2X- BEAMS & STUDS W/ 16d AT 16" O.C. CONNECTION " B " (BASE OF COLUMN)
SPECS. APPLY. USE SPF #2 MIN.
5" / 1'-0"
SPANS UP TO 7'-6" LTT20B EA. SIDE
3. REFER TO TRUSS MFG. FOR 4. SPACE FRAMING FROM HEADER TO TOP OF WINDOW/DOOR OPENING
IF NECESSARY. SPANS UP TO 10'-6" HTT16 EA. SIDE
ADDITIONAL BRACING REQUIREMENTS. SPANS UP TO 12'-6" HTT22 EA. SIDE
5. EQUIVALENT FASTENERS OF OTHER MANUFACTURES MAY BE
SUBSTITUTED FOR THE LISTED FASTENERS.
Drop Gable Endwall Detail Concrete T.B.
2
1/2" = 1'-0" TYPICAL BRG. FRAME WALL DETAIL (ALL WALL HEIGHTS)
INTERIOR, EXTERIOR & EXTERIOR NON BRG. SCALE NTS
5" / 1'-0" 5" / 1'-0"
1341 Model
DBL. 2X4 SPF #2 TOP PLATE. ON 2X4 SPF #2 STUDS @ 16"
O.C.. USE SIMPSON H-5 @ TOP & SIMPSON H-2 @ BOTT.
.
.
5" / 1'-0"
5" / 1'-0"
5" / 1'-0"
TRUSS
5" / 1'-0"
DO NOT SCALE DRAWINGS DIMENSIONS GOVERN VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ENGINEER IN WRITING OF ANY VARIATIONS BEFORE STARTING CONSTRUCTION
MTS16 TRUSS TO TOP PLATE
H6 @ EA STUD
Spec Home
1/2" CDX PLYWOOD
Roof Plan
NOTE:
TYPE SIMPSON USP ALL FRAMING IS MIN. SPF NO. 2
TYPICAL TRUSS WOOD UP TO 1195 (1) MTS16 MTW16 ALL UNMARKED ATTACHMENTS 1. EQUIVALENT FASTENERS OF OTHER MANUFACTURES ABOVE MASONRY
1 WOOD 1100 (1) MTS16 MTW16 GT-3 - use (2) 2x4's ANCHORED W/ MAY BE SUBSTITUTED PER APPROVAL OF THE
HTT4 @ BASE PERMITTING BUILDING DEPARTMENT. # Revision Date
TYPICAL KNEEWALL W/ TRUSS
Strap# 11-45-26-06-00064.0080
Drawn By jrr
Checked By ajq
8/9/2019 11:07:21 AM
S102
Structural Details & Roof Plan