COVER SHEET

PREPARED BY CHECKED BY APPROVED BY


REV.
DATE DESCRIPTION
NO.
INTLS. SIGN. INTLS. SIGN. INTLS. SIGN.

R0 15.01.19 Issued for Approval AB SAP MCM

R1 04.03.19 Reissued for Approval AB SAP MCM

R2 11.06.19 Issued for Approval AB SAP MCM

OWNER:
OIL INDIA LIMITED
DULIAJAN, DIBRUGARH, ASSAM
OWNER'S CONSULTANT:
RICHARD DESIGN SERVICES INDIA
KOLKATA
PREPARED EPC CONTRACTOR:
AB
BY: HAL OFFSHORE LTD.
CHECKED
SAP MUMBAI
BY:
APPROVED PROJECT:
MCM
BY:
WATER INJECTION SYSTEM (WIS) AT DIKOM
DATE: 11.06.19

THIS DOCUMENT IS PROPERTY OF OIL DOC. TITLE: DATA SHEET FOR DP TYPE LEVEL TRANSMITTER
AND MUST NOT BE USED EXCEPT IN
CONNECTION WITH WORK OF OIL,
REPRODUCTION, USE OR DISCLOSURE OF
THE CONTENTS OF THIS DRAWING TO OIL EPC JOB
NO. OF
THIRD PARTY/IES WITHOUT EXPRESS /
CONTRACT NO. 6208734 NO. 1118 3
WRITTEN PERMISSION OF OIL IS STRICTLY
PROHIBITTED.
SHEETS

OWNER’S / OWNER'S CONSULTANT'S


6208734-I-DSH-005
DOCUMENT NO. REV. NO. R2
EPC DOCUMENT NO. 6208734-I-IOL-005
OWNER LSTK CONTRACTOR : OIL PMC :

Document Title : DATA SHEET FOR DP TYPE LEVEL TRANSMITTER REVISION R2

Dco No. : 6208734-I-DSH-005 REVISION DATE : 11.06.19


1 Tag No. RFS 41 Ambient Temperature deg C min max -

CONDITIONS
AMBIENT
2 P&ID No. RFS 42 Humidity Range -
3 Tank No. / Vessel No. RFS 43 Altitude -
GENERAL

4 Tank Height C/C Dist. RFS - 44 Corrosivity Cat(ISO 12944-2) -


5 Service RFS 45
6 Elevation Suppresion - - 46 Enclosure Material Al Epoxy coated

ENCLOSURE
7 - 47 Ingress Protection IP 67
8 - 48 Cable Gland Entry 2 x 1/2" NPT (F)
9 Pressure kg / cm2 Min/Max /Nor RFS 49 Compartmentalization -
PROCESS CONDITION

10 Temperature 0C Min/Max /Nor RFS 50


11 Design Pressure kg / cm2 316 kg/cm2g 51 Seal Type

L-Press.Side
12 Design Temperature 0C (-) 40 to 1100 C 52 Seal Mounting
-
13 Fluid / Phase RFS 53 Diaphragm Extension Length
14 Fluid Contains soild /Abrasiveness - 54 Seal Wetted Part Material
15 Fluid Specific Gravity at T&P RFS 55 seal Model No. -
16 56 Seal Type

H-Press.Side
-
17 Element Type DIAPHRAGM 57 Seal Mounting
SENSOR/ELEMENT

18 Type of Pressure DIFFERNTIAL 58 Diaphragm Extension Length -


19 Burst Pressure 4500 PSI CHEMICAL SEAL 59 Seal Wetted Part Material -
BODY

20 Process Connection 1/2" NPT 60 seal Model No. -


21 Isolating Diaphragm Material SS316 61 Seal Upper Material Flange Material - -
22 Flange Material SS316 62 Manifold Block -
23 63 Capillary Type.
24 Calibrated Range RFS 64 Capillary Length
25 Instrument Range RFS 65 Capillary Inner Diameter -
26 Reference Accuracy(% of Span) 0.075% OR BETTER 66 Capillary Material
27 Output Load Resistance 600 Ohm 67 Capillary Armor Material
TRANSMITTER

28 Long Term Stability - 68 Fill Fluid -


29 Power Supply 24 VDC 69 Process Connection -
30 Output Signal/Communication 4 - 20 mA HART 70 -
31 Integral Indicator REQUIRED 71 Vendor Artee Flow Controls
SUPPLIER

32 Mounting Configuration SIDE MOUNTING 72 Manufacture Honeywell


33 Hazordous area class.+Protection SAFE 73 Pressure Transmitter Model RFS
34 Zero and Span Adjustment Needed 74
35 Mounting Bracket 2" Pipe 75 Fail Safe Undetected (FIT) -
RELIABILITY DATA
ACCESSORIES

36 Manifold Type/Material RFS 76 Fail Safe Detected (FIT) -


37 Maniflold instrument Connection 1/2" NPT 77 Fail Dangerous Undetected (FIT) -
38 Other Options - 78 Fail Dangerous Detected (FIT) -
39 Approval 79 Safe Failure Fraction (sff)% -
40 80

NOTE: 1) VTS- VENDOR TO SUPPLY


2) RFS- REFER FOLLOW SHEET

Page 2 of 3
OWNER: LSTK CONTRACTOR : OIL PMC :

Document Title : DATA SHEET FOR DP TYPE LT REVISION R2


Doc No.: 6208734-I-DSH-005
DP TYPE LEVEL TRANSMITTER FOLLOW SHEET REVISION DATE : 11.06.19
TANK NO. / TANK PROCESS DATA L-PRESSURE SIDE SEAL H-PRESSURE SIDE SEAL MANIFOLD / OPERATING CONDITION
SR. INSTRUMENT HEIGHT DISTANCE CALIBRATION INST. DI- TYPE / MOUNTING / TRANSMITTER PRESSURE TEMP
P&ID No. VESSEL SERVICE FLUID PHASE SPECIFIC TYPE / MOUNTING / MATERIAL / REMARK
NO. TAG NOS. NO.
RANGE (MM) RANGE () ELECTRIC EXTENSION MATERIAL MATERIAL MODEL NO.
TL.-TL. C/C GRAVITY LENGTH
EXTENSION LENGTH CONNECTION MIN MAX MIN MAX
CONST.
STD725-
Level of Raw
6208734-P- (-)10000 E1AC4AS-1-D- SIL a,
Water Storage 3-Way / SS316
1 25-LIT-101 PID-002 25-T-101 5100 - 5000 to 10000 Water Liquid - 1 - - - - AHT-11C-B- - Atm. 5 50 Target
Tank 25-T-101 /1/2"NPT (F)
MMWC 11A0-F1- RRF 2.1
0000+3VM
STD725-
Level of Service
6208734-P- (-)10000 E1AC4AS-1-D-
Water Storage 3-Way / SS316
2 25-LIT-201 PID-005 25-T-204 4300 - 3450 to 10000 Water Liquid - 1 - - - - AHT-11C-B- - Atm. 5 50
Tank 25-T-204 /1/2"NPT (F)
MMWC 11A0-F1-
0000+3VM
STD735-
Level of Filtered
6208734-P- E1AC4AS-1-D-
Water Storage (-) 7 BAR 3-Way / SS316
3 25-LIT-202 PID-005 25-T-102 13600 - 12000 Water Liquid - 1 - - - - AHT-11C-B- - Atm. 5 50
Tank 25-T-102 to 7 BAR /1/2"NPT (F)
11A0-F1-
T-1105
0000+3VM
STD725-
Level of
6208734-P- (-)10000 E1AC4AS-1-D- SIL a,
Overhead Tank 1 3-Way / SS316
4 25-LIT-204 PID-005 25-T-202 1500 - 1500 to 10000 Water Liquid - 1 - - - - AHT-11C-B- - Atm. 5 50 Target
25-T-202 /1/2"NPT (F)
MMWC 11A0-F1- RRF 8
0000+3VM
STD725-
Level of
6208734-P- (-)10000 E1AC4AS-1-D- SIL a,
Overhead Tank 2 3-Way / SS316
5 25-LIT-205 PID-002 25-T-203 1500 - 1500 to 10000 Water Liquid - 1 - - - - AHT-11C-B- - Atm. 5 50 Target
25-T-203 /1/2"NPT (F)
MMWC 11A0-F1- RRF 8
0000+3VM
STD735-
6208734-P- Level of Treated E1AC4AS-1-D-
(-) 7 BAR 3-Way / SS316
6 25-LIT-203 PID-005 25-T-201 Water Storage 13600 - 12000 Water Liquid - 1 - - - - AHT-11C-B- - Atm. 5 50
to 7 BAR /1/2"NPT (F)
Tank 25-T-201 11A0-F1-
0000+3VM

Page 3 of 3