You are on page 1of 9

PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)
NDEC
Doc. No.: 13-98-DSH-ME-122

Contract No.: Owner Doc. No.: Rev.:D02 Page: 1 of 9

Datasheet for
Wax Mix Surge Tank (TK-1304)

D02 04.Jun.2020 Final Issue S.Rafie M.Sharif M.Karimi

D01 10.Apr.2020 Issued for Review and Comment K.V. M.Sharif M.Karimi

D00 04.Feb.2020 Issued for Review and Comment K.V. M.Sharif M.Karimi

REV. DATE DESCRIPTION PREPARED CHECKED APPROVED


PMC: Project: Owner:
Fully Refined Wax Project
Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)
NDEC
Doc. No.: 13-98-DSH-ME-122

Contract No.: Owner Doc. No.: Rev.:D02 Page: 2 of 9

REVISION INDEX

REV. REV. REV. REV.


0 1 2 3 4 0 1 2 3 4 5 6 7 8 9 5 6 7 8 9
PAGE PAGE PAGE PAGE
1 X X X
2 X X X
3 X X
4 X X
5 X
6 X X
7 X X
8 X X
9 X X
PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)

Doc. No.: 13-98-DSH-ME-122


NDEC
Contract No.: Owner Doc. No.: Rev.:D02 Page: 3 of 9
* For boxes marked with *, if blank, Mfr. Shall determine and submit as per Appendix L. For all lines, see Appendix L for line-by-line instructions.
GENERAL Special Documentation Package Requirements:

Measurement Units to be used in API Std 650: SI US Customary

1. Manufacturer* Contract No.*

Address*

Mfg. Serial No.* Year Built* Edition & Addendum to API 650 *12th Edition-Latest

2. Purchaser Sepahan Oil Company Contract No.

Address

Tank Designation TK-1304

3. Owner/Operator Sepahan Oil Cmpany Location Iran-Isfahan

4. Size Limitations* Tank Diameter* ID: 7.0m Shell Height* 4.3m (4)
3 3
Capacity: Maximum* 165m Net Working* 95m Criteria*

5. Products Stored:

Liquid Wax Mix Max. S.G.: 0.9 at 70 ° C

Blanketing Gas Yes (Pressure: 2.3 kPag) Vapor Pressure 7.4 PSIA at Max. Operating Temp.

% Aromatic Suppl. Spec. H2S Service? Yes No Suppl. Spec.

Other Special Service Conditions? Yes No Suppl. Spec.

DESIGN AND TESTING Purchaser to Review Design Prior to Ordering Material? Yes No

6. Applicable API Standard 650 Appendices:* A B C F G H I J L M O P S U V W

7. Max. Design. Temp. 100 ° C Design Metal Temp.* -15 ° C Design Liquid Level* 3.81m

Design Pressure 6 kPag External Pressure - 6 kPag (15) Maximum Fill Rate 75 m3/h Maximum Emptying Rate 75 m3/h

Floatation Considerations? Yes No Flot. Suppl. Spec:* Applied Supplemental Load Spec.

8. Seismic Design? Yes No Appendix E Alternate Seismic Criteria Seismic Use Group I

MBE Site Class D (Hold) Vertical Seismic Design? Yes No Vertical Ground Motion Accelerator AV: 0.47 SDS

Basis of Lateral Acceleration (Select one): Mapped Seismic Parameters? Ss S1 S0 ; Site-Specific Procedures: MCE

Design Required? Yes No ; Other (Non-ASCE) Methods Sp = 0.3

Freeboard Required for SUG I Design Roof Tie Rods @ Outer Ring?* Yes No

9. Wind Velocity for non-U.S. sites, 50-yr. wind speed (3-sec. Gust)* 78 km/h

Top Wind Girder Style* (1) Dimensions* (1) Use Top Wind Girder as Walkway? Yes No

Intermediate Wind Girders?* Yes No Intermediate Wind Girder Style* (1) Dimensions* (1)

Check Buckling in Corroded Cond.? Yes No

10. Shell Design: 1-Ft Mthd?* Yes No ; Variable-Des-Pt Mthd?* Yes No Alternate ; Elastic Anal. Mthd?* Yes No Alternate

Plate Stacking Criteria* Centerline-Stacked? Yes No Flush-Stacked? Yes No Inside Outside

Plate Widths (Shell course heights) and Thicknesses * Numbers below Indicate Course Number.
1. 1500 x 8 mm (2,3) 2. 1500 x 6 mm (2) 3. 1300 x 6 mm (2) 4. 5.
6. 7. 8. 9. 10.
11. 12. 13. 14. 15.
Joint Efficiency* 85% % Shell-to-Bottom Weld Type* As per API 650 Shell-to-Bottom Weld Insp. Mthd* As per API 650
PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)

Doc. No.: 13-98-DSH-ME-122


NDEC
Contract No.: Owner Doc. No.: Rev.:D02 Page: 4 of 9
* If box is blank, Manufacturer shall determine and submit as per Appendix L.

11. Open-Top and Fixed Roofs: Open Top?* Yes No

Fixed Roof Type* Supported Cone Roof Support Columns*: Pipe Or Structural Shape VTA

Cone Slope* 1 : 16(min.) Dome or Umbrella Radius* Weld Joints* Lap


(Lap, Butt, Other)
Seal Weld Underside of: Lap Joints? Yes No ; Seal Weld Underside of Wind Girder Joints? Yes No

Gas-tight? Yes No Joint Efficiency* %


2
Thickness* 8 mm (2) In. Snow Load* 1.47 kN/m App. Suppl. Load Spec.* Column Lateral Load

Normal Venting Devices* one Breat Valeve (8) Emergency Venting Devices*
For Non-Frangible Roofs: Seal Weld Roof Plates to Top Angle on the Inside? Yes No ; Weld Rafters to Roof Plates? Yes No
Roof-to-Shell Detail* (1) As per Annex -F - Fig F-2 Radial Projection of Horizontal Component of Top Angle* Inward Outward

12. Bottom: Thickness* 9 mm (2) Style* Cone up to center Slope* 1:120 Weld Joint Type* Lap
Provide Drip Ring? Yes No Alternate Spec.
Annular Ring? Yes No Annular Ring: Minimum Radial Width* Thickness*

13. Foundation: Furnished by* other Type* Concrete Ring Wall


Soil Allow: Bearing Pressure* Per Spec.* Anchors: Size* (1) Qty.* (1)
Foundation Design Loads: Base Shear Force: Wind* (1) Seismic* (1) Overturning Moment: Wind* (1) Seismic* (1)
Ring Forces: Weight of Shell + Roof New* (1) Corroded* (1) Roof Live Load* 1.5 kPa Internal Pressure* 6 kPag
Partial Vacuum* Wind* Seismic*
Bottom Forces: Floor Wt. New* Corroded* Product Wt.* Water Wt.* Internal Pressure*
Partial Vacuum* Other Foundation Loads* Min. Projection of Fdn. Above Grade:
14. Responsibility for Heating Water, if Required: Purchaser Manufacturer
Hydro-Test Fill Height* 4.3 m Settlement Measurements Required? Yes No Extended Duration of Hydro-Test:
Predicted Settlement Profile is Attached
Responsibility for Setting Water Quality: Purchaser Manufacturer Supplemental Test Water Quality Spec.
Test Water Source & Disposal Tie-In Locations Hydro-Test Appendix J Tank? Yes No
Post-Pressure-Test Activities Required of the Manufacturer: Broom Clean Potable Water Rinse Dry Interior
Other
15. Inspection by in Shop; in Field
Supplemental NDE Responsibility Supplemental NDE Spec.
(Purch., Mfg., Other)
Positive Material Identification? Yes No PMI Requirements:
Max. Plate Thickness for Shearing
Must Welds not exceeding 6 mm (1/4 in.) Be Multi-Pass? Yes No Must Welds greater than 6 mm (1/4 in.) Be Multi-Pass? Yes No
Leak Test Mthd: Roof* As per API 650 Shell* As per API 650 Shell Noz./Manhole Reinf. Plt*
Bottom* As per API 650 Floating Roof Components*
Modify or Waive API Dimensional Tolerances (see 7.5)? No Yes Specify:
Specify Additional Tolerances, if any, and Circumferential and Vertical Measurement Locations:
- Allowable Plumbness: Measure and Record at a Minimum of Locations or Every m (ft) around the Tank, at
1 2
the Following Shell Heights: (select one box): /3 H, /3 H and H Top of Each Shell Course Other:
- Allowable Roundness:** Measure Radius and Record at a Minimum of Locations or Every m (ft)
around the Tank, at the Following Shell Heights (select one box):
1
Top of Tank, H /3 H, 2/3 H and H Top of Each Shell Course Other:
**See Data Sheet Instructions for the Maximum Allowable Additional Radial Tolerance.
PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)

Doc. No.: 13-98-DSH-ME-122


NDEC
Contract No.: Owner Doc. No.: Rev.:D02 Page: 5 of 9
* If box is blank, Manufacturer shall determine and submit as per Appendix L.

16. Coatings:
Internal Coatings by: Per Spec.* 13-98-ESS-PI-111, Specification for Painting
(Not Req'd., Others, Tank Mfg.)
External Coating by: Per Spec.* 13-98-ESS-PI-111, Specification for Painting
(Not Req'd., Others, Tank Mfg.)
Under-Bottom Coating by: Per Spec.* Not Req'd.
(Not Req'd., Others, Tank Mfg.)

17. Cathodic Protection System? Yes No Per Spec.*

18. Leak Detection System? Yes No Per Spec.*

19. Release Prevention Barrier? Yes No Per Spec.*

20. Tank Measurement System: Required? Yes No Remote Capability Required? Yes No

By:* Per Spec.*

21. Weight of Tank: Full of Water* (1) Empty* (1) Shipping* (1) Brace/Lift Spec.*

22. References:* API Std 650, Appendix L

23. Remarks:*
PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)

Doc. No.: 13-98-DSH-ME-122


NDEC
Contract No.: Owner Doc. No.: Rev.:D02 Page: 6 of 9
* If box is blank, Manufacturer shall determine and submit as per Appendix L.

Table 1 MATERIALS OF CONSTRUCTION


Component Material*/Thickness* C.A. Component Material* C.A.
Shell, Course _1__ to _1__ A 283 Gr C - 8 mm 1.5 Reinforcing Pads A 283 Gr C 1.5
Shell, Course _2__ to _3__ A 283 Gr C - 6 mm 1.5 Manhole/Nozzle Necks A 283 Gr C / A 106 Gr B 1.5
Shell, Course ___ to ___ Manhole/Nozzle Flanges A 283 Gr C / A 105
Shell, Course ___ to ___ Flange Covers A 283 Gr C
Shell, Course ___ to ___ Anchor Attachments A 283 Gr C 1.5
Roof A 283 Gr C 1.5 Submerged Piping A 106 Gr B 1.5
Bottom A 283 Gr C 1.5 Wetted Structurals A 36 1.5
Annular Ring A 283 Gr C 1.5 Non-wetted Structurals A 36 / S275 JR 1.5
Gasket Non-mettalic with steel-wire reinforced
+ Check here if C.A. is to apply to each exposed surface

Table 2 BOLTS and ANCHORS

Component Head Type* Bolt or Anchor Material* Nut Material* Thread Series* C.A.
Flange Bolting HEX A 193 Gr B7 A 194 Gr 2H UN ++
Structural Bolting HEX A 327 A 563 UN ++
Anchor Bolts HEX A 307 A 563 UN ++

++ Total C.A., on the nominal diameter.


Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Size, Flange Proj. to FF or


QTY Neck Sch. or Reinf. Plate Flange
Mark Service NPS, or Class or CL or from Remaks
. Wall Thick. Dimensions Type
Dia. (in.) Thick. Datum Lines

Shell Nozzles
As per As per
10NA Steam in 1 2" As per API 650 WNFF 150#
API 650 API 650
As per As per
10NB Steam out 1 2" As per API 650 WNFF 150#
API 650 API 650
11NA/B Gauge glass 2 3/4" 300#

12NA/B Gauge glass 2 3/4" 300#


As per As per
13N Drain 1 2" As per API 650 WNRF 150# With draw off sump as per API 650
API 650 API 650
As per As per API As per API As per
1M Manhole 1 24" As per API 650 With Cover Flange, Davit, Gasket, Bolt & Nuts
API 650 650 650 API 650
As per As per
1N Inlet 1 8" As per API 650 WNFF 150#
API 650 API 650
As per As per
2N Outlet 1 6" As per API 650 WNRF 150#
API 650 API 650
Level As per As per
3NA/B 2 2" As per API 650 WNRF 150#
transmitter API 650 API 650
Temperature As per As per
4N 1 1 1/2" As per API 650 WNRF 150#
indicator (TI) API 650 API 650
Water As per As per
8N 1 2" As per API 650 WNRF 150#
draw off API 650 API 650
As per As per
9N Overflow 1 10" As per API 650 WNFF 150#
API 650 API 650
PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)

Doc. No.: 13-98-DSH-ME-122


NDEC
Contract No.: Owner Doc. No.: Rev.:D02 Page: 7 of 9
* If box is blank, Manufacturer shall determine and submit as per Appendix L.

Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Size, Flange Proj. to FF or


Neck Sch. Or Reinf. Plate Flange
Mark Service QTY. NPS, or Class or CL or from Remaks
Wall Thick. Dimensions Type
Dia. (in.) Thick. Datum Lines

ROOF Nozzles
As per As per API
2M Manhole 1 20" As per API 650 As per API 650 As per API 650 With Cover Flange, Davit, Gasket, Bolt & Nuts
API 650 650
5N Gauge Hatch 1 8" As per API 650 As per API 650 WNFF 150# As per API 650
6N Inert Gas 1 4" As per API 650 As per API 650 WNRF 150# As per API 650
With pressure/vacuum relief valve & flame
7N 1 3" As per API 650
Breat. Valve As per API 650 WNFF 150# As per API 650 arrestor (8)
PMC: Project: Owner:

Fully Refined Wax Project


Doc. Title:
Datasheet for
Wax Mix Surge Tank (TK-1304)

Doc. No.: 13-98-DSH-ME-122


NDEC
Contract No.: Owner Doc. No.: Rev.:D02 Page: 8 of 9
* If box is blank, Manufacturer shall determine and submit as per Appendix L.

OTHER TANK APPURTENANCES

24. Platform, Stairway, and Railing: Galvanizing Req'd?* Yes No Stairway Style* Straight (1) Walk Surf. Type* Grating
(Straight or Helical)

Stair and Walkway Clear Width* 800 mm (min.) (1)

Architectural/Structural Specification*

Gauger's Platform Req'd? Yes No Qty. Req'd* Per Spec.*

25. Jacket Required?* Yes No Other Heaters/Coolers Required?* Yes No

Supplemental Jacket, Heater, or Cooler Specifications* Type: Heat Transfer Fluid (LP -Steam), Construction Type: Bottom Coil (12)

26. Mixer/Agitator: Quantity Size* Per Spec.*

27. Insulation: Required? Yes (13) No Thickness* Material*

Per Specs* Responsibility for Insulation and Installation


(Purchaser, Manufacturer, Others)

28. Structural Attachments: Lift Lugs?* Yes No Desc.*

Shell Anchorage?* Yes No Type* Anchor Chair (10) Scaffold Cable Support? Yes No

29. Various Other Items: Welded Flush-Type: Shell Connection Cleanout Fitting Waive Application of Appendix P? Yes No

Miscellany #1 Earth Lug Miscellany #2 Handrail

Miscellany #3 Name Plate Miscellany #4 Insulation Support

Miscellany #5 Miscellany #6

30. Remark
1) To be advised & finalized by Vendor
2) Thickness indicated are minimum. Vendor shall be responsible for mechanical design and compliance to codes and standards.
3) Thickness of first shell course shall be checked for local stresses due to anchor chair loads.
4) Tank height shall be checked by Vendor due to freeboard space.
5) Storage Tank shall be desiged and supplied as per specification for Storage Tank Doc. No.: 13-98-ESS-ME-104
6) Grating stairs treads and fastening clips to be galvanised in accordance with ASTM A 123
7) Manufacturere drawings shall be submitted by Vendor for purchasr's approval.
8) All venting requirement such as size, quantity & type shall be rechecked & finalized by vendor according to API -2000
9) All flange connections shall be according to ASME B16.5 up to 24" & as per B16.47 series "A" for 26" and over
10) Anchore chairs & anchore bolts shall be calculated by Vendor based API 650
11) Bolt holes shall be straddle to vertical / horizontal centerline.
12) Heating coil (E-1371) shall be designed & supplied by Vendor based on the following:
Heat Transfer fluid: LP-Steam, Operating Temprature: 151 °C(max.), Operating Pressure: 4 barg (max.), Design Temprature: 265 °C(max.),
Design Pressure: 6.1 barg, U= ~100 W/m 2K, Total surface required: 37m2
13) Insulation type is Heat Conservation. Refer to Specification for Insulation 13-98-ESS-PI-104 for more detail.
14) All welded attachments such as insulation support. Pipe clipe & etc. are in vendor's scope of work/supply.
15) Stiffening ring requirement for external pressure loading shall be checked & calculated according to API 650 annex V.