You are on page 1of 8

API Std 650 Storage Tank

KDDB Data Sheet PAGE 1 OF 7


* For boxes marked with *, if blank, Mfr. Shall determine and submit as per Appendix L. For all lines, see Appendix L for line-by-line instructions.
GENERAL Special Documentation Package Requirements:

Measurement Units to be used in API Std 650: SI US Customary

1. Manufacturer* Contract No.*

Address*

Mfg. Serial No Year Built* Edition & Addendum to API 650* 12th Edition-Latest

2. Purchaser Contract No.

Address

Tank Designatio

3. Owner/Operator Location Kuwait

4. Size Limitations Tank Diameter* 15m hell Height* 8.4m

Capacity: Maximum et Working* 1193 m 3


Criteria*

5. Products Stored:

Liquid Crude Oil Max. S.G.: 1.02 at 15.56 ° C

Blanketing Ga Vapor Pressure 13 PSIA at Max. Operating Temp.

% Aromatic Suppl. Spec. H2S Service?Yes No Suppl. Spec.

Other Special Service Conditions? Yes No Suppl. Spec.

DESIGN AND TESTING Purchaser to Review Design Prior to Ordering Material? Yes No

6. Applicable API Standard 650 Appendices


A B C F G H I J L M O P S U V W

7. Max. Design. Temp ° Design Metal Temp.* ° Design Liquid Level* 8.4 m

Design Pressur 6.89 kPa xternal Pressure -3.44 kPa ximum Fill Rate 120 m /Hr3
aximum Emptying Rate 120 m3/Hr

Floatation Considerations?
Yes No Flot. Suppl. Spec:* Applied Supplemental Load Spec.

8. Seismic Design? Yes No Appendix E Alternate Seismic Criteria Seismic Use Group 1

MBE Site Class D Vertical Seismic Design?Yes No Vertical Ground Motion Accelerator AV:

Basis of Lateral Acceleration (Select one) Mapped Seismic Parameters?Ss S1 S0 ; Site-Specific Procedures: MCE

Design Required? Yes No ; Other (Non-ASCE) Metho Sp = 0.075

Yes
Freeboard Required for SUG I Design Roof Tie Rods @ Outer Ring No

9. Wind Velocity for non-U.S. sites, 50-yr. wind speed (3-sec. Gu 162 km/Hr

Top Wind Girder Styl Detail - 'I' Dimensions* e Top Wind Girder as Walkway? Yes No

Intermediate Wind Girders?*Yes No Intermediate Wind Girder Style* Dimensions*

Check Buckling in Corroded Cond.?Yes No

10. Shell Design:


1-Ft Mthd?* Yes No ; ariable-Des-Pt Mthd?* Yes No Alternate ;Elastic Anal. Mthd?* Yes No Alternate

Plate Stacking Criteria*


Centerline-Stacked? Yes No Flush-Stacked? Yes No Inside Outside

Plate Widths (Shell course heights) and Thicknesses * Numbers below Indicate Course Number.
1. 2400 x 8 2. 2000 x 8 3. 2000 x 8 4. 2000 x 8 5.
6. 7. 8. 9. 10.
11. 12. 13. 14. 15.

Joint Efficiency* % Shell-to-Bottom Weld Type Shell-to-Bottom Weld Insp. Mt

Approvals: Revisions: Title:


By: Ck'd: Date:
Drawing No.: Sheet of
API Std 650 Storage Tank
AMETANK Data Sheet PAGE 2 OF 7
* If box is blank, Manufacturer shall determine and submit as per Appendix L.

11. Open-Top and Fixed Roofs: (See Sheet 6 for Floating Roofs) Open Top?* Yes No

Fixed Roof Type* Cone Roof Support Columns*:Pipe Or Structural Shape

Cone Slope* 1 : 6 ome or Umbrella Radius* Weld Joints* Lap


(Lap, Butt, Other)
Seal Weld Underside of: Lap Joints? Yes No ; Seal Weld Underside of Wind Girder Joints? Yes No

Gas-tight? Yes No Joint Efficiency* %


Thickness* 7 mm In. Snow Load App. Suppl. Load Spec Column Lateral Loa

Normal Venting Device Emergency Venting Devices*

For Non-Frangible Roofs: Seal Weld Roof Plates to Top Angle on the Inside? Yes No ; Weld Rafters to Roof Plates? Yes No

Roof-to-Shell DetaiDetai 'I' of Annex -F - Fig F-2 Radial Projection of Horizontal Component of Top Angle*
Inward Outward

12. Bottom: Thickness* 10 Style* Cone - Up Slope* 1 : 35 Weld Joint Type* Lap

Provide Drip Ring?Yes No Alternate Spec.

Annular Ring? Yes No Annular Ring: Minimum Radial Wid 750 (min) Thickness* 10 mm

13. Foundation: Furnished b Type* Ring Wall


Soil Allow: Bearing Pressu Per Spec.* Anchors: Size* VTC Qty.* VTC
Foundation Design Loads: Base Shear Force: eismic* erturning Moment: Wind* VTC Seismic* VTC
Ring Forces: Weight of Shell + Roof Corroded* Roof Live Load* 1.2 kPa nternal Pressure* 6.89 kPa
Partial Vacuum Wind* Seismic*
Bottom Forces: Floor Wt. N Corroded* Product Wt.* Water Wt.* nternal Pressure*
Partial Vacuu ther Foundation Loads* . Projection of Fdn. Above Grade:

14. Responsibility for Heating Water, if Required:Purchaser Manufacturer

Hydro-Test Fill Heigh8.4 m Settlement Measurements Required?Yes No Extended Duration of Hydro-Test:

Predicted Settlement Profile is Attached

Responsibility for Setting Water Quality: Purchaser Manufacturer Supplemental Test Water Quality Spec.

Test Water Source & Disposal Tie-In Locat ydro-Test Appendix J Tank? Yes No

Post-Pressure-Test Activities Required of the Manufacturer:


Broom Clean Potable Water Rinse Dry Interior

Other
15. Inspection b in Shop; in Field
Supplemental NDE Responsibilit upplemental NDE Spec.
(Purch., Mfg., Other)
Positive Material Identification?Yes No PMI Requirements:

Max. Plate Thickness for Sheari

Must Welds not exceeding 6 mm (1/4 in.) Be Multi-Pass?


Yes No Must Welds greater than 6 mm (1/4 in.) Be Multi-Pass?
Yes No

Leak Test Mthd: Roo Shell* As per API 650 Shell Noz./Manhole Reinf. P
Bottom* As per API 650 oating Roof Components*

Modify or Waive API Dimensional Tolerances (see 7.5)?


No Yes Specify:

Specify Additional Tolerances, if any, and Circumferential and Vertical Measurement Locations:
- Allowable Plumbness: sure and Record at a Minimum of cations or Every m (ft) around the Tank, at
the Following Shell Heights: (select one box): 1
/3 H, 2/3 H and H Top of Each Shell Course Other:
- Allowable Roundness: easure Radius and Record at a Minimum of cations or Every m (ft)
around the Tank, at the Following Shell Heights (select one box):
Top of Tank, H 1
/3 H, 2/3 H and H Top of Each Shell Course Other:
**See Data Sheet Instructions for the Maximum Allowable Additional Radial Tolerance.
Approvals: Revisions: Title:
By: Ck'd: Date:
Drawing No.: Sheet of
API Std 650 Storage Tank
AMETANK Data Sheet PAGE 3 OF 7

16. Coatings:
Internal Coatings by Per Spec.* As Per Spec
(Not Req'd., Others, Tank Mfg.)
External Coating by: Per Spec.* As Per Spec
(Not Req'd., Others, Tank Mfg.)
Under-Bottom Coating by Per Spec.* As per Spec
(Not Req'd., Others, Tank Mfg.)

17. Cathodic Protection System? Yes No Per Spec.*

18. Leak Detection System? Yes No Per Spec.*

19. Release Prevention Barrier? Yes No Per Spec.*

20. Tank Measurement System: Required? Yes No Remote Capability Required? Yes No

By:* Per Spec.*

21. Weight of Tank: Full of Water Empty* Shipping* Brace/Lift Spec.*

22. References:* API Std 650, Appendix L

23. Remarks:*
1. Nozzle Elevation and Orientation to be confirmed after site visit on contract award
2. the T

Approvals: Revisions: Title:


By: Ck'd: Date:
Drawing No.: Sheet of
API Std 650 Storage Tank
AMETANK Data Sheet PAGE 4 OF 7

* If box is blank, Manufacturer shall determine and submit as per Appendix L.


Table 1 MATERIALS OF CONSTRUCTION

Component Material*/Thickness* C.A. Component Material* C.A.


Shell, Course _1__ to _4__ A 283 Gr C - 8 mm 1.6 Reinforcing Pads A 283 Gr C 1.6
Shell, Course ___ to ___ Manhole/Nozzle Necks A 283 Gr C / A 106 Gr B 1.6
Shell, Course ___ to ___ Manhole/Nozzle Flanges A 283 Gr C / A 105
Shell, Course ___ to ___ Flange Covers A 283 Gr C
Shell, Course ___ to ___ Anchor Attachments A 283 Gr C 1.6
Roof A 283 Gr C 1.6 Submerged Piping A 106 Gr B 1.6
Bottom A 283 Gr C 3.2 Wetted Structurals A 36 / S275 JR 1.6 +
Annular Ring A 283 Gr C 3.2 Non-wetted Structurals A 36 / S275 JR 1.6 +
+ Check here if C.A. is to apply to each exposed surface

Table 2 BOLTS and ANCHORS

Component Head Type* Bolt or Anchor Material* Nut Material* Thread Series* C.A.
Flange Bolting HEX A 193 Gr B7 A 194 Gr 2H UN ++

Structural Bolting HEX A 327 A563 UN ++

Anchor Bolts HEX A 307 / BS4190 A 563 UN ++

UN
++ Total C.A., on the nominal diameter.

Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Full
Neck Pen.
Size, Sch or On Flange Proj. to FF or Remaks
NPS, or Wall Reinf. Plate Open. Flange Class or CL or from Gasket Thick.
Mark Service Dia. (in.) Thick. Dimensions (Y/N) Type Thick. Datum Lines and Dimen.
Shell Nozzles

N1 Inlet 8" WNRF 150# Note-4

N2 Outlet 8" WNRF 150# Note -5

N3 Level 3" WNRF 150#

N4 Level 3" WNRF 150#

N5 Level 3" WNRF 150#

N6 Level 3" WNRF 150#

N7 Spare 4" WNRF 150# W/ Blind

N8 Drain 3" WNRF 150#

N9 Sample
Foam 4" WNRF 150# VTC
Connecti
N10 on. 1" WNRF 150#
Recircula
N11 tion Line 3" WNRF 150#

Heating
N12 Coil 3" WNRF 150#
Heating
N13 Coil 3" WNRF 150#

N14 Spare 3" WNRF 150# W/ Blind

N15 Spare 3" WNRF 150# W/ Blind

N16 Spare 3" WNRF 150# W/ Blind


Clean
M1 Out 24" As per API 650 W/ Cover+Davit
Approvals: Revisions: Title:
By: Ckd: Date:
Drawing No.: Sheet of
API Std 650 Storage Tank
AMETANK Data Sheet PAGE 5 OF 7

* If box is blank, Manufacturer shall determine and submit as per Appendix L.

Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Full
Neck Pen.
Size, Sch or On Flange Proj. to FF or Remaks
NPS, or Wall Reinf. Plate Open. Flange Class or CL or from Gasket Thick.
Mark Service Dia. (in.) Thick. Dimensions (Y/N) Type Thick. Datum Lines and Dimen.
ROOF Nozzles

N17 BLANK
VENT 2" WNRF 150# GAS
ET
N18 Emerge
GAAS 4" WNRF 150# Note -5
ncy
N19 Vent 24" WNRF 150# W/ Emergency Vent

N20 PVSV 6" WNRF 150#


Manhol
M2 e 24" As per API 650 W / Cover + Davit
MTG
N21 LVL 2" WNRF 150#

N22 Spare 2" WNRF 150# W/ Blind

N23 Spare 2" WNRF 150# W/ Blind

Clean
Out 24" As per API 650 W/ Cover+Davit
Approvals: Revisions: Title:
By: Ckd: Date:
Drawing No.: Sheet of
API Std 650 Storage Tank
AMETANK Data Sheet PAGE 6 OF 7

* If box is blank, Manufacturer shall determine and submit as per Appendix L.

OTHER TANK APPURTENANCES

24. Platform, Stairway, and Railing: Galvanizing Req'd?*Yes No Stairway Style* Spiral Walk Surf. Type* Greating
(Straight or Helical)

Stair and Walkway Clear Widt 1000 mm National Safety Standards*

Architectural/Structural Specification

Gauger's Platform Req'd? Yes No Qty. Req'd* 1 Per Spec.*

25. Jacket Required?* Yes No Other Heaters/Coolers Required?* Yes No

Supplemental Jacket, Heater, or Cooler Specification

26. Mixer/Agitator: Quantity Size* Per Spec.*

27. Insulation: Required? Yes No Thickness* Material*

Per Specs* Responsibility for Insulation and Installation


(Purchaser, Manufacturer, Others)

28. Structural Attachments: Lift Lugs?* Yes No Desc.*

Shell Anchorage?* Yes No Type* Scaffold Cable Support? Yes No

29. Various Other Items: Welded Flush-Type: Shell Connection Cleanout Fitting Waive Application of Appendix P? Yes No

Miscellany # Heating Coil Miscellany #2

Miscellany # Miscellany #4

Miscellany # Miscellany #6

Table 4 OTHER TANK APPURTENANCES*

Service or Height from


Mark Quantity Description Size Orientation Datum Material Remarks

Approvals: Revisions: Title:


By: Ck'd: Date:
Drawing No.: Sheet of
API Std 650 Storage Tank
AMETANK Data Sheet PAGE 7 OF 7

* If box is blank, Manufacturer shall determine and submit as per Appendix L.

Tank Plan and Sketches:

Notes:

Approvals: Revisions: Title:


By: Ck'd: Date:
Drawing No.: Sheet of

You might also like